How to set up CJ1W-EIP21 (CJ1W-ETN21) routing table using CX Integrator
Просмотров 2,4 тыс.Год назад
Actually, the settings will be exactly the same for CJ1/CS1 EIP21 ( Ethernet/IP module) and ETN21 ( FINS Ethernet module), for NS HMI or Scada FINS communications, it is necessary to set up the network number using this method.
Omron CP2E Quick Start in 10 mintues
Просмотров 3,8 тыс.Год назад
Omron CP2E Quick Start in 10 minutes, just quickly shows up the following: 1. Procedures to make a basic program 2. Global/local symbol, assign local symbols for programming. 3. CIO starting address ( input) from 0.00, output address from 100.00. 4. Set/Reset PLC instruction 5. TIM( BCD type) on-delay timer 6. Writing comments for your ladder program 7. Compile the program 8. Simulation 9. PLC ...
NX1P2/CP2E PLCs talk to Raspberry PI Node-Red via FINS Ethernet Part1 ( CP2E)
Просмотров 1,4 тыс.Год назад
NX1P2/CP2E PLCs talk to Raspberry PI Node-Red via FINS Ethernet Part1 ( CP2E)
Omron ACE 4.0/i4L-350 Robot Pick & Place Wizard Walkthrough and De-stacking demo programming
Просмотров 1,8 тыс.Год назад
Omron ACE 4.0/i4L-350 Robot Pick & Place Wizard Walkthrough and De-stacking demo programming
Using SD Card to log the data from NJNX PLC, then go via FTP to transfer data to Microsoft Power BI
Просмотров 1,2 тыс.2 года назад
Using SD Card to log the data from NJNX PLC, then go via FTP to transfer data to Microsoft Power BI Example program download link ( Only for subscribers) drive.google.com/file/d/1FQJBAaKAAbnThRfzTn5xTa89MXKzOBCt/view?usp=sharing
How to log Omron 1S or G5 servo actual Torque/ Position/Speed
Просмотров 1,7 тыс.2 года назад
How to log Omron 1S or G5 servo actual Torque/ Position/Speed
Using Robot to polish my shoes
Просмотров 1652 года назад
Using Robot to polish my shoes
Set up CP2E to control 3G3MX2 via MODBUS RTU serial communications
Просмотров 8 тыс.2 года назад
Set up CP2E talks to 3G3MX2 via MODBUS RTU serial communications Example program download link ( Only for subscribers) drive.google.com/drive/folders/1JWRdIeGJjrFuHYu-Kw7DupH_dfWVq7ab?usp=sharing
How to set up Omron CP2E PLC to communicate to NB HMI via Ethernet
Просмотров 17 тыс.3 года назад
NB-Designer Ver1.53 Download link ( Only for subscribers): drive.google.com/file/d/1qi7SAtsj0QjuzMp7nf269e81e025ZW2K/view?usp=sharing
NX102 to Microsoft SQL Database Training Video Part2 ( SQL Software installation)
Просмотров 4463 года назад
This is supplementary information for NX102 to Microsoft SQL Database direct connection training video. This training video shows up the whole process of how to download & install Microsoft SQL Server 2019, of course, if you have installed the software already, you can definitely ignore this training video.
Omron NX102 SQL Client direct connection to Microsoft SQL Database server Part1
Просмотров 3 тыс.3 года назад
Omron NX102 SQL Client direct connection to Microsoft SQL Database server Part1
How to set up Ormon NJ501 PLC to communicate to CJ2 and CS1 PLC via Ethernet/IP for Data exchange
Просмотров 5513 года назад
How to set up Ormon NJ501 PLC to communicate to CJ2 and CS1 PLC via Ethernet/IP for Data exchange
How to set up NTP Client on NX102 PLC, and synchronize time to internet NTP server
Просмотров 1,2 тыс.3 года назад
How to set up NTP Client on NX102 PLC, and synchronize time to internet NTP server
Utilize RoboDK to simulate TM12 Robot movement
Просмотров 1853 года назад
Utilize RoboDK to simulate TM12 Robot movement
Omron Sysmac Studio vs Rockwell Studio 5000 (Part1)
Просмотров 1,3 тыс.3 года назад
Omron Sysmac Studio vs Rockwell Studio 5000 (Part1)
Set up NX1P2 to communicate to CP1L/CP2E via FINS Ethernet protocol
Просмотров 6 тыс.3 года назад
Set up NX1P2 to communicate to CP1L/CP2E via FINS Ethernet protocol
Omron HD1500 Autonomous Mobile Robot on-site trial
Просмотров 7353 года назад
Omron HD1500 Autonomous Mobile Robot on-site trial
CP2E new FINS Ethernet function block
Просмотров 3,7 тыс.3 года назад
CP2E new FINS Ethernet function block
Using CS1W-ENT21 Socket service to implement the Modbus TCP comms
Просмотров 1,7 тыс.3 года назад
Using CS1W-ENT21 Socket service to implement the Modbus TCP comms
Use Omron NX102 to communicate to Proface HMI via Ethernet/IP
Просмотров 4,1 тыс.3 года назад
Use Omron NX102 to communicate to Proface HMI via Ethernet/IP
How to use Omron NX102 PLC to communicate to FQ2 Camera via Ethernet/IP network.
Просмотров 3,7 тыс.3 года назад
How to use Omron NX102 PLC to communicate to FQ2 Camera via Ethernet/IP network.
Using voice to control Omron TM Robot
Просмотров 5383 года назад
Using voice to control Omron TM Robot
How to set up Datalink in between NX EIC202 EthernetIP coupler and PLC EIP master module
Просмотров 2 тыс.3 года назад
How to set up Datalink in between NX EIC202 EthernetIP coupler and PLC EIP master module
How to configure Ormon NX EIC202 EthernetIP coupler
Просмотров 4,1 тыс.3 года назад
How to configure Ormon NX EIC202 EthernetIP coupler
How to program Omron NS series HMI broken line graph
Просмотров 9623 года назад
How to program Omron NS series HMI broken line graph
How to find out the unknown IP address for Omron PLC
Просмотров 8 тыс.3 года назад
How to find out the unknown IP address for Omron PLC
Omron Zen programming plus Simulation
Просмотров 5764 года назад
Omron Zen programming plus Simulation
How to set up Omron LD Robot route for demonstration
Просмотров 4834 года назад
How to set up Omron LD Robot route for demonstration
How to share data in between CJ2M PLC and V430 Code Reader Using Ethernet/IP
Просмотров 8924 года назад
How to share data in between CJ2M PLC and V430 Code Reader Using Ethernet/IP

Комментарии

  • @ApplicationEngineering
    @ApplicationEngineering 19 дней назад

    Nice shoes, I can polish this for you too ;)

  • @jmbcrp1010
    @jmbcrp1010 Месяц назад

    Estáticamente generalmente da bien , en condiciones normales en movimiento y con banda transportadora ahí vienen los problemas

  • @galihwicaksono391
    @galihwicaksono391 Месяц назад

    Is it possible to simulate and check communication using only a cp2e plc and a leptop pc (nb designer) without using NB HMI hardware?

  • @florianhaas9822
    @florianhaas9822 Месяц назад

    Hi and thank you for the tutorial. My OPC UA client can connect when Security mode is none. However, whenever I am trying to connect via Basic256Sha256 (Sign&Encrypt) the server does not recognize my client certificate in the rejected folder. I tried uploading the client certificate manually but didn't work. What can be the root cause for this?

  • @mikecrawford6526
    @mikecrawford6526 2 месяца назад

    I subscribed and requested the download, but never received access to the library 😔

  • @hillaldody9470
    @hillaldody9470 2 месяца назад

    mang terima kasih ya mang, akhirnya saya bisa konek ke nx102 mokasih, kagek dibelike seblak 1 porsi

  • @NicoReig
    @NicoReig 2 месяца назад

    Hi, i'm trying a new project for my degree, i'm having some problems connecting the PLC (Omron CP2E) to the NB7 screen. Would you mind helping me?

  • @alextadeu8026
    @alextadeu8026 3 месяца назад

    Thank you !

  • @HelpmeHomeservices
    @HelpmeHomeservices 3 месяца назад

    Thanks so good. That's very useful.

  • @zzazayabrau1784
    @zzazayabrau1784 3 месяца назад

    I want to try the library, thanks :)

  • @amanatturk-yl8ud
    @amanatturk-yl8ud 3 месяца назад

    please make a video for CJ1M cpu11 ETN with NS series HMI

  • @sigit0155
    @sigit0155 3 месяца назад

    I use an Omron CQM1H plc. But when I want to connect between the CX integrator and the PLC device, why isn't there a CQM1H device option?

  • @alextadeu8026
    @alextadeu8026 4 месяца назад

    Thanks !!

  • @lucasbitelo3263
    @lucasbitelo3263 6 месяцев назад

    Hello Friend !!!! Here in my company's electrical workshop in Brazil we have an OMROM NX1P2 PLC. I'm using a network adapter because the notebook doesn't have an RJ 45 input, but USB. I can't find the CLP IP. My question? Does the USB/RJ 45 adapter "disrupt" IP identification? hugs and have a great week!!!!!

    • @yangqiu472
      @yangqiu472 6 месяцев назад

      if you are using a USB adapter, which is different than using a PC in-built Network card if you can't find its IP address from Omron Comms utility, you can try using Wireshark software to do it, which will be similar to Omron's utility, but the advantage of Wireshark, you will be able to monitor the USB adapter network card specifically. Wireshark website:www.wireshark.org/

    • @BlueNachid
      @BlueNachid 25 дней назад

      @@yangqiu472 Wireshark didnt worked out for me.I'll test again with your hints from this video.

  • @rizkihermansyah895
    @rizkihermansyah895 6 месяцев назад

    sir.. i was subscribe.. give me permit to download sourcecode.. helpme please sir.. thankyou...

  • @rizkihermansyah895
    @rizkihermansyah895 6 месяцев назад

    sir.. i was subscribe.. give me permit to download sourcecode.. helpme please sir.. thankyou...

  • @febrisetiawan6510
    @febrisetiawan6510 7 месяцев назад

    Did you succeed in reading the holding register data from schneider power meter (PM2200)?

  • @user-ef9cd9sg6o
    @user-ef9cd9sg6o 7 месяцев назад

    Thanks boss

  • @sintumaintenancework4542
    @sintumaintenancework4542 8 месяцев назад

    Very nice performance sir

  • @kevinvaneykeren1
    @kevinvaneykeren1 8 месяцев назад

    Hi Yang, i am trying to output "RX350h" to controllogix 5000 PLC. does it output in ASCii. how do i get the characters to send to the PLC from the OCR. thanks!

  • @susclik
    @susclik 9 месяцев назад

    Thanks for sharing!

  • @igorsoldan4476
    @igorsoldan4476 9 месяцев назад

    Grazie mille i suoi video in generale sono piuttosto molto curati!!! Bravo veramente

  • @igorsoldan4476
    @igorsoldan4476 9 месяцев назад

    Come posso scaricare l'FB????

  • @ramchets
    @ramchets 9 месяцев назад

    Hi , can we use fins as a TCP IP? To communicate external device

  • @siangleng73
    @siangleng73 9 месяцев назад

    Thanks you very much but I cant download the sample due to dun have access

  • @AbdulazizShaheen
    @AbdulazizShaheen 10 месяцев назад

    Hi, is it possible to reset the password after forgetting it to unlock the password for PLC OMRON NX102-9000?

    • @artsphotographytomstudio1733
      @artsphotographytomstudio1733 10 месяцев назад

      You can rewrite the NX102 program, it is important to reset the password unless you knew the password and able to go online with NX102. Sysmac new PLC password encryption is much safer than C series PLCs.

    • @AbdulazizShaheen
      @AbdulazizShaheen 10 месяцев назад

      @@artsphotographytomstudio1733 There is no other solution than rewriting the program Even if I have the program license code

  • @aritzlopez8610
    @aritzlopez8610 10 месяцев назад

    Is this possible between a plc (Nj) and a data adquisition device software?

    • @yangqiu472
      @yangqiu472 10 месяцев назад

      I guess you want to use data link to acquire data from a PC to an NJ PLC? If that is your application, the answer is yes or no. If you have Omron Sysmac gateway or CX-compolet installed, it is okay to do it, otherwise you can’t use Ethernet/IP data link on a PC.

    • @aritzlopez8610
      @aritzlopez8610 10 месяцев назад

      @@yangqiu472 Yup thats the case I was afraid I cant directly. Thx

  • @habibgetoh2907
    @habibgetoh2907 11 месяцев назад

    Hi, this vide is really helpful. I have a problem, why is the communication time between CIF11 and Inverter takes 5 second each instruction to send from PLC to Inverter, I know this because the Indicator Blinking LED on the CIF11 only blinks once every 5 seconds. Do you know why is that ?

  • @marciordr8627
    @marciordr8627 11 месяцев назад

    Oi poderia me enviar o programa

  • @jfpatxo8707
    @jfpatxo8707 11 месяцев назад

    where is part2 for NX1P2 ?

  • @karnova100
    @karnova100 11 месяцев назад

    "Hi, I am Ankarnova, and I have subscribed to your RUclips channel. Can I request access to download the software from the link you shared?"

  • @alan7609
    @alan7609 11 месяцев назад

    P R O M O S M 💥

  • @jvjayaraman2483
    @jvjayaraman2483 Год назад

    Sir possible to send link CX programmer 9.8 version

    • @yangqiu472
      @yangqiu472 Год назад

      industrial.omron.eu/en/products/cx-one#software

  • @jvjayaraman2483
    @jvjayaraman2483 Год назад

    Please same model PLC how to add additional IO Unit need one video please

    • @yangqiu472
      @yangqiu472 Год назад

      Adding more IO units is quite straightforward, it is Unlike CJ/CS PLC, no need to set up an IO table, you just simply add them on, which is OK, For CP2E, you can add up 3 expansion units in max, and For PLC addressing, just keep counting up. For example, CP2E input starts from 0, 1, and the expansion unit starting address for inputs will be 2.00, all the way up, CP2E outputs start from 100.00 and 101.00, so the expansion unit starting address for outputs will start from 102.00. hope the above information will help you.

    • @yangqiu472
      @yangqiu472 Год назад

      for info, please refer to ruclips.net/video/fU0LBV-2a3Q/видео.htmlsi=sZUjojUdovic5LTu

  • @rayaid8014
    @rayaid8014 Год назад

    why when I try to set connect on MQTT.fx it says "MqttSecurityException: Not authorized to connect" ? what step I do wrong?? can someone explain it?? \

  • @user-oy7ib3wb3r
    @user-oy7ib3wb3r Год назад

    Thank you very much for the video and sharing the library. It works!

  • @ers_goes
    @ers_goes Год назад

    Mr, i want try. that sample. thanks very much Mr YANG QIU

  • @tyyuiotyioop9633
    @tyyuiotyioop9633 Год назад

    Hello...I have requested access to your files on google drive...Can you accept my request ?..thanks

    • @yangqiu472
      @yangqiu472 Год назад

      Done, please check your email.

  • @TimMagang
    @TimMagang Год назад

    Good Day thank you for the tutorial. can i have access for the file ? , Thank You

  • @fuadwidiatmoko6803
    @fuadwidiatmoko6803 Год назад

    hey friend, very inspiring video. btw, how if I have 1 NX1P2 and 12 CP2E-N PLCs. all connected into 1 network, does this fins system still can be applied or it has maximum plcs that can be connected ?

    • @yangqiu472
      @yangqiu472 Год назад

      It depends on which protocol you are using, Normally it is FINS UDP, and it can be set up to 16 Devices, like you said, you have 12 CP2E PLCs, so it is fine for using FINS UDP to carry out the communications. Another way is to use MQTT, but for settings, quite complicated than FINS comms.

    • @fuadwidiatmoko6803
      @fuadwidiatmoko6803 Год назад

      @@yangqiu472 thanks a lot

  • @art12345ar
    @art12345ar Год назад

    Thank you very much

  • @daeyongkim2698
    @daeyongkim2698 Год назад

    감사합니다.....^^

  • @mohammadharba1920
    @mohammadharba1920 Год назад

    thanks for the vedio ,,very helpfull can you share the cx drive !!!!!! please

  • @mohammadharba1920
    @mohammadharba1920 Год назад

    i need cx-drvie to program my vfd , please provide to me

  • @mohammadharba1920
    @mohammadharba1920 Год назад

    supper supper

    • @yangqiu472
      @yangqiu472 Год назад

      CX-drive is part of CX-one software, Do you have CX-one software?

  • @BalaMurugan-he3jn
    @BalaMurugan-he3jn Год назад

    Hi sir! Thx for your support Fq2_camera 0 function block protect so please share password sir I need to study purpose

  • @selvinlopez9293
    @selvinlopez9293 Год назад

    Hi YANG QIU....Could you make a video explaining the procedure for connecting to Azure IoT Hub through MQTT?

    • @yangqiu472
      @yangqiu472 Год назад

      Good suggestion, I will make one when I am free. Honestly, connecting to the Azure IoT hub is a bit complicated, with quite many procedures.

  • @vanderlei10147
    @vanderlei10147 Год назад

    Is it possible to communicate the NX102 with the CP1H like the video?

    • @yangqiu472
      @yangqiu472 Год назад

      Yes, you can definitely do the same communications, but please be aware that NX102 only port2 supports FINS protocol, so you must use Port2 from NX102 CPU, also CP1H doesn't have an in-built Ethernet port, you need to add an Ethernet option board onto CP1H, for the rest of settings will be the same as my example. let me know if you come across a hassle.

  • @dongyingliu4947
    @dongyingliu4947 Год назад

    牛逼

  • @scottsteinhoff5151
    @scottsteinhoff5151 Год назад

    Thank You! This video cleared up a few problems I have been experiencing.