- Видео 57
- Просмотров 99 410
MHK Building Solutions
Добавлен 5 ноя 2022
MHK Building Solutions provide a wide range of gas and electrical services for your domestic and commercial premises. From boiler replacements to full property rewires, MHK Building Solutions provide a friendly, hassle free and most important of all, professional service in the Yorkshire region UK.
How to Replace a Worcester Bosch Left Side Flow Manifold | Step-by-Step Guide
DISCLAIMER:
This video is only intended for use by qualified Gas Safe Registered engineers. You must not attempt any work on your boiler if you are not qualified. You must always carry out 26.9 checks upon completion of works on a boiler.
⚠️ Always ensure proper safety measures are taken when working with gas appliances. If in doubt, consult a professional.
📌 Don't forget to like, comment, and subscribe for more boiler repair and maintenance tips!
If anyone has any tips or different ways to do it, drop a comment below so we can help each other out!
Thanks for watching!
This video is only intended for use by qualified Gas Safe Registered engineers. You must not attempt any work on your boiler if you are not qualified. You must always carry out 26.9 checks upon completion of works on a boiler.
⚠️ Always ensure proper safety measures are taken when working with gas appliances. If in doubt, consult a professional.
📌 Don't forget to like, comment, and subscribe for more boiler repair and maintenance tips!
If anyone has any tips or different ways to do it, drop a comment below so we can help each other out!
Thanks for watching!
Просмотров: 111
Видео
How to Replace a Vaillant Boiler Auto Air Vent | Guide for Gas Engineers
Просмотров 1074 часа назад
In this video, we demonstrate the step-by-step process of replacing the auto air vent on a Vaillant boiler. Designed for gas engineers and trainees, this tutorial provides all the tips and techniques you need to perform this task effectively and safely. 🔧 What You'll Learn: Identifying the location and function of the auto air vent. Tools required for the job. Detailed walkthrough of removing a...
How to Service a Vokera Combi Boiler & Replace the Auto Air Vent | Gas Engineer's Guide
Просмотров 66312 часов назад
In this video, we walk you through the complete servicing of a Vokera combi boiler, including replacing the auto air vent. Perfect for gas engineers and trainees, this guide highlights key steps to maintain boiler efficiency and ensure safe operation. 🔧 What You'll Learn: Comprehensive Vokera combi boiler servicing. How to identify, remove, and replace a faulty auto air vent. Essential tools an...
How to TEST A GAS VALVE/ STEPPER MOTOR! (Quick and easy tutorial)
Просмотров 41921 час назад
In this video, we demonstrate how to test a stepper motor using two gas valves from a Vaillant EcoTEC Plus boiler. The video covers: - Identifying a working vs. faulty gas valve. - Understanding fault code F26 related to the stepper motor. - Step-by-step resistance testing using manufacturer-provided readings. - This guide is perfect for engineers, technicians, or boiler technicians who want to...
Underfloor Heating Pressure Testing- How to
Просмотров 10521 день назад
My son enjoyes spending time on site and learning new things. www.mhkbuildingsolutions.co.uk www.mhkbuildingsolutions@gmail.com #ufh #plumbing #howto #pressuretesting #plumbinginstallation #plumbingknowhow
Vaillant Ecotec Plus 838 F28 & F29 intermittent Fault Error Repair - Easy Step-by-Step DIY Guide!
Просмотров 1,4 тыс.3 месяца назад
Are you dealing with the frustrating F.28 and F.29 intermittent fault codes on a Vaillant Ecotec Plus 838 combi boiler? In this video, I’ll walk you through an easy, step-by-step repair that will help you fix these common issues and get the boiler running smoothly again. Don’t forget to like, comment, and subscribe for more repair guides. If this video helped you, share it with others who might...
How to Drill Through Steel Beams with a Cordless Drill
Просмотров 8673 месяца назад
Drilling holes in structural steel to facilitate a good fixing sounds daunting and / or expensive but it really isn't. Watch me as I drill 13mm holes in a 152x152UC23 beam (RSJ) with a cordless drill and standard HSS drill bit. Don't forget to like, comment, and subscribe for more maintenance and repair tutorials! www.mhkbuildingsolutions.co.uk mhkbuildingsolutions@gmail.com #diyprojects #const...
How to Replace the Diverter Cartridge and Actuator Motor on a Potterton Titanium Combi 40 ERP Boiler
Просмотров 7485 месяцев назад
Boiler Repair In this step-by-step guide, I demonstrate how to replace the diverter cartridge and actuator motor on a Potterton Titanium Combi 40 ERP gas boiler. Baxi, Main and and Potterton have a similar diverter system. Don't forget to like, comment, and subscribe for more maintenance and repair tutorials! www.mhkbuildingsolutions.co.uk mhkbuildingsolutions@gmail.com #BoilerRepair #Potterton...
How to Install a Hive Dual Channel Thermostat on an Unvented Heating System | Step-by-Step Guide
Просмотров 3,9 тыс.5 месяцев назад
Looking to upgrade your home heating system with a Hive Dual Channel Thermostat? In this comprehensive step-by-step guide, we'll show you how to install a Hive thermostat on an existing unvented heating system. From unboxing to wiring and setup, we cover it all. Plus, we include crucial safety tips on how to prove dead before starting any electrical work, ensuring a safe installation process. 🔧...
Power consumption of LED lights. How to calculate Amps.
Просмотров 9736 месяцев назад
This is just a quick video to jog your memory if you are interested in electricity and power consumption of lights and appliances etc. I would love to hear your method of working out the power consumption of these lights. www.mhkbuildingsolutions.co.uk Feel free to drop me a line and I will get back to you :). #Electrician #gas #trade #fun #share #followme
How to check- No Power to the Boiler. Continuity Testing. Fault finding.
Просмотров 9426 месяцев назад
If you have no power to the boiler PCB, you can check the incoming supply at the fused spur and if there is power present at the fused spur, check the load side of the fused spur. If you also have power on the load side of the the fused spur and no power coming to the PCB then your cable between the fused spur and PCB is faulty. #electric #heating #multimeter #trade #testing #gas #engineer If y...
Vaillant Eco Tec Plus Gas Boiler- Main Heat Exchanger and Burner Assembly 837, 637, 937, F28
Просмотров 1,2 тыс.7 месяцев назад
#GasEngineering #GasIndustry #Engineering #GasSafety #RenewableEnergy #EnergyEfficiency #NaturalGas #GasDistribution #GasSafetyTips #GasRegulations I was called out to repair a F28 fault on a Vaillant Eco Tec Plus 837 Combi Boiler. We found that the main heat exchanger HEX was badly leaking and ruined the burner assembly as well as the fan. We managed to source a green heat exchanger and burner...
How To Test A Boiler Pump Using Multimeter- Pump Testing
Просмотров 7 тыс.7 месяцев назад
#plumbing #boiler #heating #heatingrepair #electricscooter You can use your multimeter to test the heating pump. I like to use Fluke multimeters. www.mhkbuildingsolutions.co.uk Thank you for watching. If you enjoyed this one please don't forget to LIKE & SUBSCRIBE.
This Job Went From A Boiler Service To A Difficult Repair! Took Most Of The Morning.
Просмотров 1,3 тыс.8 месяцев назад
This Job Went From A Boiler Service To A Difficult Repair! Took Most Of The Morning.
PFC- Electrical Testing Measuring Prospective Fault Current PFC (How to do a PSCC and PEFC Test)
Просмотров 1328 месяцев назад
PFC- Electrical Testing Measuring Prospective Fault Current PFC (How to do a PSCC and PEFC Test)
Ze Test- Electrical testing LIVE measuring external earth fault loop impedance Ze
Просмотров 3038 месяцев назад
Ze Test- Electrical testing LIVE measuring external earth fault loop impedance Ze
Worcester Greenstar - How To Change / Replace the Return Manifold / Block / Unit Right hand
Просмотров 4498 месяцев назад
Worcester Greenstar - How To Change / Replace the Return Manifold / Block / Unit Right hand
Noisy Ideal Boiler- Ideal Logic Noise Humming L2 F2 faults, Lack of service, Gas Valve, Burner
Просмотров 3979 месяцев назад
Noisy Ideal Boiler- Ideal Logic Noise Humming L2 F2 faults, Lack of service, Gas Valve, Burner
How to Diagnose- Unvented Cylinder Water Leaking From TRV/ PRV into Tundish
Просмотров 38810 месяцев назад
How to Diagnose- Unvented Cylinder Water Leaking From TRV/ PRV into Tundish
Vokera Evolve- How to put a Vokera Evolve into Service Mode High Low CO Readings & CO/CO2 Ratio
Просмотров 37710 месяцев назад
Vokera Evolve- How to put a Vokera Evolve into Service Mode High Low CO Readings & CO/CO2 Ratio
Worcester No Hot Water. Breakdown no hot water Worcester Bosch Greenstar Combi Boiler Heating fine.
Просмотров 48710 месяцев назад
Worcester No Hot Water. Breakdown no hot water Worcester Bosch Greenstar Combi Boiler Heating fine.
Vaillant Fault F28 29 54, Resistance gas valve readings. 22vdc 16vdc. How to diagnose Vaillant fault
Просмотров 1,5 тыс.10 месяцев назад
Vaillant Fault F28 29 54, Resistance gas valve readings. 22vdc 16vdc. How to diagnose Vaillant fault
How not to install a radiator bracket. Radiator installation disasters.
Просмотров 13411 месяцев назад
How not to install a radiator bracket. Radiator installation disasters.
No hot water on a combi boiler. Faulty flow sensor due to a water leak. Combi boiler repair.
Просмотров 2,5 тыс.11 месяцев назад
No hot water on a combi boiler. Faulty flow sensor due to a water leak. Combi boiler repair.
Hive mini full installation. How to install a smart thermostat programmer. Hive Nest Honeywell EPH
Просмотров 52711 месяцев назад
Hive mini full installation. How to install a smart thermostat programmer. Hive Nest Honeywell EPH
How to wire a boiler control, thermostat, programmer. Hive wired incorrectly.
Просмотров 83111 месяцев назад
How to wire a boiler control, thermostat, programmer. Hive wired incorrectly.
How to install Google Nest learning smart thermostat programmer. Nest Hive Smart. Boiler programmer.
Просмотров 15011 месяцев назад
How to install Google Nest learning smart thermostat programmer. Nest Hive Smart. Boiler programmer.
Interactive live session on Boiler wiring with fellow gas engineers. How to wire EPH Salus ESI HIVE
Просмотров 38011 месяцев назад
Interactive live session on Boiler wiring with fellow gas engineers. How to wire EPH Salus ESI HIVE
Live with MHK Building Solutions- Vaillant Q&A Ecotec Canoe Filter Heat exchanger PCB Replacement
Просмотров 3,2 тыс.11 месяцев назад
Live with MHK Building Solutions- Vaillant Q&A Ecotec Canoe Filter Heat exchanger PCB Replacement
How to test a wiring harness for continuity. Boiler continuity testing using a multimeter. Vaillant
Просмотров 2,7 тыс.Год назад
How to test a wiring harness for continuity. Boiler continuity testing using a multimeter. Vaillant
Excellent vid!
Thanks a lot.
Excellent explaination and presentation
@@cfgman1 Thanks for your support. I am glad you found it useful.
Informative video again thanks 🙏
@@lemonkeyconvertible848 Thanks for the support buddy!
@ Slaam brother can you do a video about wiring Y plan and S plan because I have seen your videos which you uploaded on RUclips which live on TikTok I believe . I am newly qualified and learning about this . Thanks
W sallam and yes I will make it insha'Allah. I have a WhatsApp group for gas engineers if you want to join. Drop me a WhatsApp message on 07876786286 and I will send you the invite.
Good advice thx 😊
Glad it was helpful!
Very informative video and helpful for new gas engineers.hiw can I get a copy of that valiant book you mentioned in the video?
@@Royalgasyork thanks for your admiration. Please drop me a line on my WhatsApp and I will forward it on to you.
@@MHKBuildingSolutions What is your whats up?
hi just stated working on these please send link this should help thanks
Just search for "Go Through ratchet set" and you will find in online.
I’ve been out to a few of these. On a couple the sump had got blocked at the outlet, it was hard to clean the sump out , do you have any tips for doing this?
I normally put a black bin liner under the bent pipe before removing which collect all the water when I remove the bent plastic pipe. Once you have removed the pipe it's easier to clean it. I will try to make a video of it when I come across it next time.
Thank you mate for the explanation. Any chance for a copy please.
Yes sure buddy, find me on Google, send me a WhatsApp message and I will forward it on.
Best way to service a vokera is to gently take it off the wall then sling it out the front door and replace it with a baxi 👌🏻
Agreed, they did have a shitty rep for a good while when the old Lineas and that where around years ago. But the recent ones appear to be ok. Still, i wouldn't fit one on my of my own choice.
Even Vaillant, Viessman, Worcester or Ideal.
Please note; In the UK, under the Gas Safe regulations, it is illegal for anyone other than a Gas Safe Registered Engineer to remove the covers from any gas boiler or gas appliance. If an unauthorised person was to service the boiler / appliance and it resulted in a death caused by faulty work then the unauthorised person would be spending several years in prison.
@@elainejohnbarnard4147 Totally agreed and I would say the exact same. I should start to include a similar message in my videos.
That ratchet looks amazing. You got a link for it?
whats max min ment to be on
@@JoyOleary-j5q max and min settings are for engineers to ensure that the appliance is working correctly.
Best place for these boilers is in the skip. Do vokera actually have warranty engineers?
Yeah
Vokera & Viessmann are both owned by the same American company called Carrier. So their warranty engineers work on both makes of appliance
Why are my boiler lights flashing from radiator to water when I switch hot water on resulting in no hot water.
@@Chris-tn8zq can you make a video and send me it on WhatsApp.
I could if I have a number
@Chris-tn8zq just search "Mhk building solutions" on Google and you will find my number.
I think I've found the problem I think it's the flow switch with the magnet inside because when I put a magnet to the sensor the boiler fires up an produces hot water maybe it needs replacing.
Good stuff
Would this be on all boilers for example what would be the reading on a baxi boiler on ignition lead? Would it be same ohms 900?
@@Razz60 No readings could be different with each manufacturers and even different models at times. I will try to source some information about baxi and other manufacturers.
@MHKBuildingSolutions Thankyou and your videos are so helpful, do you run any training courses?
Thank you MHK for perfect explanation, hope to here more about different Gas valve . best wishes
@@cyrustayebi thanks for your support mate.
Very helpful.
@@lemonkeyconvertible848 I am glad you enjoyed it mate.
Yet another fantastic video. Thanks again, still loving the content. I'd love a copy aswel please when you get time. Thank you 💪💪👌👌🔧🔧
@@samdavid7414 Thanks for the support buddy. Just drop me a line on my Whatsapp and I will forward it on to you.
I am presently sitting in a cold house because my Worcester Bosch Greenstar 37cdi combi boiler has been wrongly labelled as needing lots of new parts by a HomeServe fitter. A new PCB is on the way even though there is zero evidence of a fault by looking at it. What is more easy to diagnose is the pump which runs perfectly and quietly ie. Good bearings. The original error code was for overheating but I believe this might be due to a faulty sensor. If you could do a video on testing them it would help me a lot. Please keep up the good work.
I am sorry to hear that. I hope your problem is now resolved.
Could I get a copy please
@@adija12 yes buddy find me on Google, drop me a line on Whatsapp and I will forward it on. Have a fiver ready 😂
Thank you need more videos like this every week
@@madshepsreef282 I will try to keep it coming mate however I would support from all of of you watch, share and subscribe to the channel to keep me motivated 😁
Great content mate, any chance of a copy please mate
@@MC-ud3zz Yes drop me a line on Whatsapp and I will forward it on.
Can I get a copy too please
I've messaged you on WhatsApp mate 👍
@badger8186 it's been forwarded to you buddy.
@muhammadgreen9711 yes bro, drop me a line on Whatsapp and I will forward it on to you.
👍
Hey, I have a question, what is the part underneath the NTC thermistor, the black plug, I found a diagram and it said Part No: 248079 but the black plug (which has cracked) doesn't line up, any info on the wiring harness is appreciated
The black connector on the same pipe is an overheat/ high limit stat mate .
Excellent explanation
Glad it was helpful!
Which part of the cartridge needs silicone grease? The rubber o-rings definitely but is it worth greasing anywhere else?
Just grease the o rings.
@ Thank you
Mine won’t fill , the keys in position and I’ve fully turned the white bolt back but nothing’s happening. Can you strip the valve so I can see what’s happening please 🙏
did you insert the key in fully and turned it to the lock position?
37cdi pump always on?
@@vincentmatthews1662 do you have a GC number for the boiler mate?
Great video thank you
You didn't drain the expansion vessel?
@@oldguy8078 It was drained when the boiler drained mate.
E20 fault came back after the thermistor was changed. So what's next?
Have you made sure that the wiring harness is intact? Check the wires (continuity test) between the thermistor and PCB.
Had this today was open line 👍
You wouldn't expect this cable to be damaged as they have used a thick quality cable however I have come across it many times where it's faulty.
I know how to do it lol
@@Kaikaiblogs that's 👍
Was this on an LPG boiler? I ask as on the gas valve it seems as though it has a regulator which is only on LPG or am I mistaken? Thanks.
@@GasTraining No it's Natural gas.
No
@@tonybarnard-ri6bo ok lol
Have to watch more of your interesting videos mate
@@MohammedWahab-he1mt I am glad you liked the videos mate. Yes watch all the videos and share also as I could do with some watch time 😂
@@MohammedWahab-he1mt watch em all bro :)
Hi great video, do you have a link for the manual you use please
I believe it's been sent to you via WhatsApp 🙂
Are you in london at all? Mines needs a service
I am based in West Yorkshire :).
Please can you do a video on how to replace manifold . Thanks
Yes Usman I will make a video on that soon :).
Excellent tutorial
@@999smiley999 Thanks 👍
really good video would of been nice to see you doing the resistance readings on the harness though
@@Ed-fp9rx I will make another video showing the harness test.
Do you sell parts ?
@@richierich.1982 no buddy I don't
Would this also be the case for the newer modulating erp pumps
I will check a newer style pump and get back to you.
So if that cartridge snaps when removing? Can you open the the flow nut on the bottom to help take out the rest of old cartridge?
@@Razz60 Yes you can remove the whole block and try to remove the cartridge. Many engineers would just change the block instead of changing the cartridge.
@@MHKBuildingSolutions ok i see so its good to mention to customer theres a possibility could snap an whole block may need replacing
@@Razz60 Yes it's always good to leave a caveat as anything could happen.
Such a good video so well explained thank you
@@Razz60 I am glad you liked the video. Please don't forget to like and subscribe 😀
Great explanation. However I assume that if an existing system with a wireless thermostat was replaced with a Hive system then a simple replacement of the programmer is the only change required, ie no linking of brown and blue ch wires at the junction box.
Yes Dave you are correct.
Brilliant vid
Thanks buddy
How can I get in contact with you I want to learn breakdowns
Hi mate, just search for MHK Building Solutions on google and my contact details are there :).
Can you do video how to learn breakdown of sequence operation basic fundematals
I will try to make a video in the near future.