Actual Electrical Content
Actual Electrical Content
  • Видео 264
  • Просмотров 644 006
BIG solar farm BIG cables
back on a solar farm doing some BIG cables
I am a Freelance electrical engineer &, electrical trainer for hire and I work all across the UK.
Specializing in ..
industrial electrical installations,
process electrical engineering ,
motors and control systems
! if you can find me you can hire me . I am “ jamie blatant sparky” on both linked in and Instagram so drop me a message on there
Alternatively my company is Rt industria Ltd and our website website is actualelectricalcontent.co.uk/
Просмотров: 4 944

Видео

SELF EMPLOYED SPARKY BLOG #10 OCTOBER 24
Просмотров 1,3 тыс.14 дней назад
the carnage continues in month 10 of making a living on my own I am a Freelance electrical engineer &, electrical trainer for hire and I work all across the UK. Specializing in .. industrial electrical installations, process electrical engineering , motors and control systems ! if you can find me you can hire me . I am “ jamie blatant sparky” on both linked in and Instagram so drop me a message...
BIG CABLE CRIMPING AND TERNANATING - the equipment
Просмотров 1 тыс.21 день назад
i look at some of the equipment required to crimp big cables and ill show you how its used in future videos I am a Freelance electrical engineer &, electrical trainer for hire and I work all across the UK. Specializing in .. industrial electrical installations process electrical engineering motors and control systems if you can find me you can hire me . I am “ jamie blatant sparky” on both link...
3 PHASE MOTOR & CONTROLS part 2
Просмотров 1,5 тыс.Месяц назад
ALL MY MOTORS CONTENT IS IN THIS PLAYLIST ! ruclips.net/p/PLwWEIwGOrfFAEtAlu2HCSUMs6CdD2jv2v number 2 in a series on motors and there control I am a Freelance electrical engineer &, electrical trainer for hire and I work all across the UK. Specializing in .. industrial electrical installations process electrical engineering motors and control systems if you can find me you can hire me . I am “ ...
Only dirty fans tripping
Просмотров 705Месяц назад
A fan tripping the breaker what could it be ALL MY MOTORS CONTENT IS IN THIS PLAYLIST ! ruclips.net/p/PLwWEIwGOrfFAEtAlu2HCSUMs6CdD2jv2v I am a Freelance electrical engineer &, electrical trainer for hire and I work all across the UK. Specializing in .. industrial electrical installations process electrical engineering motors and control systems if you can find me you can hire me . I am “ jamie...
3 PHASE MOTOR & CONTROLS part 1
Просмотров 2,5 тыс.Месяц назад
number one in a series on motors and there control ALL MY MOTORS CONTENT IS IN THIS PLAYLIST ! ruclips.net/p/PLwWEIwGOrfFAEtAlu2HCSUMs6CdD2jv2v I am a Freelance electrical engineer &, electrical trainer for hire and I work all across the UK. Specializing in .. industrial electrical installations process electrical engineering motors and control systems if you can find me you can hire me . I am ...
failed spur wont isolate , but looks dead
Просмотров 980Месяц назад
why you should always check your isolation I am a Freelance electrical engineer &, electrical trainer for hire and I work all across the UK. Specializing in .. industrial electrical installations, process electrical engineering , motors and control systems ! if you can find me you can hire me . I am “ jamie blatant sparky” on both linked in and Instagram so drop me a message on there Alternativ...
SELF EMPLOYED SPARKY BLOG #9 september 24
Просмотров 1,2 тыс.Месяц назад
the carnage continues in month 9 of making a living on my own I am a Freelance electrical engineer &, electrical trainer for hire and I work all across the UK. Specializing in .. industrial electrical installations, process electrical engineering , motors and control systems ! if you can find me you can hire me . I am “ jamie blatant sparky” on both linked in and Instagram so drop me a message ...
SOLAR 1 YEAR LATER & BLACKOUTS PREP
Просмотров 1,8 тыс.Месяц назад
my solar 1 year later and a bit of prep for power cuts I am a Freelance electrical engineer &, electrical trainer for hire and I work all across the UK Specializing in industrial electrical installations, process electrical engineering & motors and control systems ! if you can find me you can hire me . I am “ jamie blatant sparky” on both linked in and Instagram so drop me a message on there Al...
SAFE ISOLATION & UK GARAGE
Просмотров 1,4 тыс.2 месяца назад
SAFE ISOLATION & UK GARAGE
HOME UPS - INTERNET IN POWERCUTS
Просмотров 1 тыс.2 месяца назад
HOME UPS - INTERNET IN POWERCUTS
SELF EMPLOYED SPARKY BLOG #8 AUGUST
Просмотров 9702 месяца назад
SELF EMPLOYED SPARKY BLOG #8 AUGUST
MOTORS MASTERCLASS - mechanical motor inspections
Просмотров 1,6 тыс.2 месяца назад
MOTORS MASTERCLASS - mechanical motor inspections
RAF greenham common - cold war engineering tour
Просмотров 3,5 тыс.2 месяца назад
RAF greenham common - cold war engineering tour
HIGH VOLTAGE Protection devices
Просмотров 1,6 тыс.3 месяца назад
HIGH VOLTAGE Protection devices
CHEAPER RENEWABLES QUOTES wacth this
Просмотров 1,3 тыс.3 месяца назад
CHEAPER RENEWABLES QUOTES wacth this
SOLAR CABLE FIRES & FAULTS in ducts
Просмотров 7 тыс.3 месяца назад
SOLAR CABLE FIRES & FAULTS in ducts
ELECTRICANS EARNINGS self employed blog July #8
Просмотров 2,8 тыс.3 месяца назад
ELECTRICANS EARNINGS self employed blog July #8
EV nick telling electricians what we should earn FROM THE ESK (ELEITR SPARKY KREW)
Просмотров 2,3 тыс.3 месяца назад
EV nick telling electricians what we should earn FROM THE ESK (ELEITR SPARKY KREW)
Why are EV owners such bells to electricans FROM THE ESK (ELEITR SPARKY KREW)
Просмотров 1,1 тыс.3 месяца назад
Why are EV owners such bells to electricans FROM THE ESK (ELEITR SPARKY KREW)
HOW TO PASS C&G 2391 essential course preparation and guide #electrican #2391
Просмотров 1,6 тыс.3 месяца назад
HOW TO PASS C&G 2391 essential course preparation and guide #electrican #2391
TRAINING - LIVE LINE TAPPING TX FAULT
Просмотров 5903 месяца назад
TRAINING - LIVE LINE TAPPING TX FAULT
TRAINING - FAILED ISOLATION
Просмотров 7733 месяца назад
TRAINING - FAILED ISOLATION
LOST ELECTRICAN SKILLS - HOW TO Make a box spanner
Просмотров 2,9 тыс.4 месяца назад
LOST ELECTRICAN SKILLS - HOW TO Make a box spanner
TRAINING - HV EXPLOSIONS root cause analisis
Просмотров 3314 месяца назад
TRAINING - HV EXPLOSIONS root cause analisis
TRAINING - the packer moving carrousel Drawing challange
Просмотров 6554 месяца назад
TRAINING - the packer moving carrousel Drawing challange
Lathe Motor Repair - control gear
Просмотров 1,3 тыс.4 месяца назад
Lathe Motor Repair - control gear
BACK SELF EMPLOYED BLOG #7 june 24
Просмотров 1,2 тыс.4 месяца назад
BACK SELF EMPLOYED BLOG #7 june 24

Комментарии

  • @RobertWheeler-t4z
    @RobertWheeler-t4z День назад

    If you divide the volts by the resistance, that will give you the amps....Change the amps to KW and check against the motor plate... In this case 400 volts divided by 45 which is about 10amps .... then take 10amps * (400 volts divided by 1000watts) = 4 kw motor. Also, it is worth noting that one test that people don;t do is checking that you are not single phasing the motor. Make sure that you have all 3 phase's at the motor. It is common that a pole will fail across the contactor,. Test at the isolator incoming. Also, check that the motor is not seized.... Undo the fan shroud at the back of the motor and spin it by hand. Lastly, Check the motor plate, 3 phase motors have varied winding configurations like star delta, PWM, delta, delta..... etc

  • @peteb3365
    @peteb3365 День назад

    mmm all that lurrvly scrap copper 😜

  • @Tezza66
    @Tezza66 День назад

    wot a load of bollox, subscribed :p

  • @rhannahr1550
    @rhannahr1550 День назад

    Thanks, great video

  • @zaxmaxlax
    @zaxmaxlax День назад

    17:28 the definition of "do what I say, dont do what I do" 😂😂😂

    • @Actual_electrical_content
      @Actual_electrical_content День назад

      I’ve done it but I massive avoid it and I means I’ve done it twice maybe 3 times in emergencies

  • @stefanovanenio
    @stefanovanenio 2 дня назад

    I love fucking around with the big stuff. Great tips and love the honestly. I always get my apprentice to watch these types of videos

  • @penlam
    @penlam 2 дня назад

    Thanks for the video, helped knock off some of the cobwebs. Possibly a video looking at a bad motor in the future?

  • @gardenogauge
    @gardenogauge 3 дня назад

    Have you got the link to those clamps/brackets for the panels? Cheers

  • @ColinDH12345
    @ColinDH12345 3 дня назад

    Why didn't you start at the new cabinet and work backwards? Could have kept the lugs on. Could have saved cutting precious cable for any future changes. Would have left a 'nest' at the green cabinet but would that have been a real problem? Genuine question.

    • @Actual_electrical_content
      @Actual_electrical_content 3 дня назад

      Because the cable was existing and the lugs wouldn’t fit through the glands anyway , it would always need to be re terminated

    • @Actual_electrical_content
      @Actual_electrical_content 3 дня назад

      Yea none ferrous plate is for that very purpose

  • @gardenogauge
    @gardenogauge 3 дня назад

    With the phase conductors going through separate holes isn't this going to give you issues with eddy current heating? Or does the gland plate being ally mitigate that?

  • @erikslagter3231
    @erikslagter3231 4 дня назад

    serious work done here

  • @nevans8416
    @nevans8416 5 дней назад

    Great video, when we do heat shrinking for 33kv joints we always shrink tubes from centre out to work any moisture that may have accidentally got into the tube out to the edges. Just how we were taught thats all. 👍👍

  • @allanharris9074
    @allanharris9074 5 дней назад

    First time viewer and subscriber here. If only I knew about the tip of the constant pressure spring from the jointing kits years ago. Would have saved the copius amounts of insulting tape used and then binned. I like the trigger attachment for the crimper/cutter heads. Will be watching more of the videos and I like the technical term for the trefoil layout. Nice (real life) site work complete with the banter.

  • @hvsparky
    @hvsparky 5 дней назад

    i love the electricery bit @1:50 haha

  • @0dbm
    @0dbm 6 дней назад

    Respect the crimp Excellent video

  • @Whereswally606
    @Whereswally606 6 дней назад

    Shelly em are awesome. Also lots of esphome projects that can port data in realtime to home assistant if you do want data and control over your inverter. But truthfully its all a nice to have.

  • @thedutchgamerguy8580
    @thedutchgamerguy8580 6 дней назад

    Hi Jamie, is there anything against using standard short shank lugs on fine stranded cable? ive always been taught that for fine stranded cable you need to use the longer lugs, like the klauke dynamic range. longer shank and more indentations. curious to see what your thoughts are on this

    • @Actual_electrical_content
      @Actual_electrical_content 6 дней назад

      I always take my specs out of the cembre catalog as per my previous video , in this case the lugs and the crimper were supplied as specked by others so I was just working with what was supplied , the lugs were by knauke and they aeemed to do the trick with 2 crimps

  • @sheffieldhoney
    @sheffieldhoney 6 дней назад

    Measure 20 times, cut once 😃 cool stuff

  • @simplestuff3895
    @simplestuff3895 6 дней назад

    That b’stard music is stuck in my head. Dick 😂

  • @picobyte
    @picobyte 6 дней назад

    At least the PV fields here in the Netherlands have all that mess inside environ-mental save concrete and steel boxes.

  • @raywelshman
    @raywelshman 7 дней назад

    Hi Jamie, I'm sure Tony from Jointech Cabling would be happy with your work, I don't know if you watch his videos at all? Nice hydraulic crimper matey. Regards from the old sod

    • @Actual_electrical_content
      @Actual_electrical_content 6 дней назад

      Yea tony is the pro at this , unfortunately the pump is on hire and not mine but all the cutting and crimp heads are mine that I use every so often

  • @MADSPARKS31
    @MADSPARKS31 7 дней назад

    Great electrical content, sir. 💪🫡

  • @MADSPARKS31
    @MADSPARKS31 7 дней назад

    "Never drill a lug, never drill a lug out" Why the fuck you lying...!! LMFAO 😂😂😂

  • @evchargingsolutionslimited5334
    @evchargingsolutionslimited5334 7 дней назад

    Think you will find those Mac ladders were the property of K star electrical services bought from the Mac man in Bingham a long time ago. Awesome ladders.

  • @UCCLdIk6R5ECGtaGm7oqO-TQ
    @UCCLdIk6R5ECGtaGm7oqO-TQ 7 дней назад

    So what current are those good for? Inverter must be mind blowing.

  • @calumclark1719
    @calumclark1719 7 дней назад

    This maybe a absolutely stupid question but to save the issue with the gland plate and individually why not use a Watertight gland block similar to that used aboard ship bulkheads as I assume you cant use large ducting due to heat build up, neat job but seems that part of the job is a design ballache that could be avoided at the early stage of the inverters manufacture

    • @Actual_electrical_content
      @Actual_electrical_content 7 дней назад

      The none ferrous plate is just the way it’s allways been done and is the de facto standard and it’s got a lot of strength and is cost effective

    • @calumclark1719
      @calumclark1719 7 дней назад

      @Actual_electrical_content fair enough, my thinking was it would save a lot of jigging around but it comes down to cost the reason it used aboard ship is as its a huge time and money saver

    • @Actual_electrical_content
      @Actual_electrical_content 7 дней назад

      Would probably get eaten by rats too

    • @calumclark1719
      @calumclark1719 7 дней назад

      @Actual_electrical_content possibly they do eat anything,

  • @zjzozn
    @zjzozn 7 дней назад

    So very interesting... Liking the hydraulic kit... Hope to see you use that on a house rewire soon

  • @zjzozn
    @zjzozn 7 дней назад

    I wondered how they grew so many Solar Panels. How long do they take to grow?

  • @MrDleete-mj9vt
    @MrDleete-mj9vt 7 дней назад

    This is exactly how I explain it to young engineers. Should do video on cascadence with similar method of explanation haha

  • @herrtomas6729
    @herrtomas6729 7 дней назад

    I wonder how many of our politicians realise what it takes to upgrade our infrastructure! They talk so glibly about upgrading....... They simply don't have a clue. Good video again Jamie.

    • @Actual_electrical_content
      @Actual_electrical_content 7 дней назад

      Yea people don’t realize the skill required to keep stuff running properly and upkeep it

  • @ARC_CONTROL
    @ARC_CONTROL 7 дней назад

    You shouldn't mark only the nut. You should always draw a STRAIGHT line down the thread and onto the nut, that way if it's working itself loose due to a fault, vibration, harmonics whatever you can diagnose it early.

    • @Actual_electrical_content
      @Actual_electrical_content 7 дней назад

      They were marked at the end with paint , this is a small window on your a big job

  • @ARC_CONTROL
    @ARC_CONTROL 7 дней назад

    You can also use hose clamps, a bit of wire twisted on. Also Alroc and the like also sell LV stripping tools and an exhaust cutter can help you strip your cable round.

    • @Actual_electrical_content
      @Actual_electrical_content 6 дней назад

      I would never put a hose clamp around a cable , I did use and exhaust cutter to do some of these too

  • @aidanmurphy5246
    @aidanmurphy5246 8 дней назад

    Great work mate,nothing wrong with throwing a few fucks around 😆

  • @MarcJWebbMusic
    @MarcJWebbMusic 9 дней назад

    Where are the plastic coloured tabs from ? All I am finding are the crappy paper ones

  • @TechmeistersLtd
    @TechmeistersLtd 9 дней назад

    What's your thoughts on voltage optimising for air con and heat pumps?

  • @TechmeistersLtd
    @TechmeistersLtd 9 дней назад

    This made me laugh. Brilliant. i might have to give you a follow!

  • @simplestuff3895
    @simplestuff3895 11 дней назад

    Even with no load, USB sockets show up like birds round a bag on a thermal camera

  • @ChristopherOwen-gi5wh
    @ChristopherOwen-gi5wh 11 дней назад

    Part 2 was absolutely fucking brilliant - I went and built a test rig after watching it haha. Great content 👍🏻

  • @peppigue
    @peppigue 11 дней назад

    the grass is always more colorful on the other side of the fence

  • @wilbertvandenberg3158
    @wilbertvandenberg3158 12 дней назад

    Super F*** instruction ! THANKS.

  •  12 дней назад

    😂😂😂 it was never in question

  • @simplestuff3895
    @simplestuff3895 12 дней назад

    Good vid. People ‘research’ ‘stuff’ on the internet, play top trumps and miss the bigger picture. The internet just makes stupid people stupider. This is why I haven’t done domestic jobs for years.

  • @NickyLong89
    @NickyLong89 13 дней назад

    You didn’t do your apprenticeship with Cannon Electrical by any chance did you? I had a similar path to you of working at Nottm University and then spent a bit of time over the road at QMC. Well, i say a bit, probably 18 months of my 4 year apprenticeship i spent there! Still have nightmares about those service voids 🤢 Nice video mate and very true what you say about taking chances and opportunities.

    • @Actual_electrical_content
      @Actual_electrical_content 12 дней назад

      Yea I was cannon 1997 - 2000 did most off my time there with tony long and harry parry, I’ve still got a set of void keys

  • @Jonesy551
    @Jonesy551 13 дней назад

    Awesome video mate, thanks for sharing this with us. Nearly had me crying like a little bitch at the end!!! It's true though, the main major push to do manly shit when I was younger was the fear of being called a p*ff if you didn't have the balls to do it!!!

  • @whitey4909
    @whitey4909 13 дней назад

    Proper tickled me

  • @willohagan4601
    @willohagan4601 13 дней назад

    Good video and great advice mate

  • @scottclark3588
    @scottclark3588 13 дней назад

    😂😂😂 love it, I wanna work with you!

  • @stephenhill6479
    @stephenhill6479 13 дней назад

    Good video. I enjoyed the pictures at the end.Your right , and sometimes you need reminding of this

  • @matthewtilly83
    @matthewtilly83 13 дней назад

    Thanks for clearing that up 😂😂😂

  • @raywelshman
    @raywelshman 14 дней назад

    Hi Jamie, this is one of your best videos ever, I have aways seen through your normal persona to see what a genuine nice guy you really are. Regards from the old sod.