Cascade Solar & Electric
Cascade Solar & Electric
  • Видео 14
  • Просмотров 29 327

Видео

Tesla Powerwall 2
Просмотров 2396 месяцев назад
Installation of a Tesla Powerwall 2 system.
Sol-Ark 15KW Fortress Lithium Battery Off Grid Solar Power System
Просмотров 4,3 тыс.6 месяцев назад
Sol Ark 15KW Inverter installed with a E-Vault Max Fortress Power Battery. Off grid solar power system.
Enphase IQ8 Battery Backup Solar System
Просмотров 5707 месяцев назад
7.5KW Silfab Solar System with IQ Batteries and System Controller
RV Solar Battery System
Просмотров 60Год назад
Solar and battery system upgrade to an RV. 400ah storage, 800 watts Solar, 2000 watt inverter
Full River Schneider Off Grid Battery Solar System Generator Support
Просмотров 100Год назад
Full River Schneider Off Grid Battery Solar System Generator Support
Outback Flex Power One Renogy Battery Bank 24 Volt Container Power
Просмотров 114Год назад
Off Grid System at a community garden at a school in Denver. 24V DC 120V AC output.
NOCO Genius Battery Charger Full River 12V DC-105 Test Charge From 100% Dead
Просмотров 223Год назад
Using a NOCO Genius Battery charger we are going to see if we can bring these Full River DC105-12 batteries back to life from 100% dead.
Enphase IQ8 Solar System Battery Backup Whole Home Smart Switch
Просмотров 9 тыс.Год назад
Enphase IQ8 Solar System Battery Backup Whole Home Smart Switch
Enphase IQ8 Solar Only with Smart Switch - Set up for future battery
Просмотров 9 тыс.Год назад
Enphase IQ8 Solar Only with Smart Switch - Set up for future battery
SolArk Compatibility with Tigo Rapid Shutdown Transmitter Part 2
Просмотров 2,3 тыс.Год назад
SolArk Compatibility with Tigo Rapid Shutdown Transmitter Part 2
SolArk Compatibility with Tigo Rapid Shutdown Transmitter Part 1
Просмотров 641Год назад
SolArk Compatibility with Tigo Rapid Shutdown Transmitter Part 1

Комментарии

  • @olaade2109
    @olaade2109 10 дней назад

    Hello, after connecting the battery output into the storage terminals below, where does the wires of the storage breaker comes? Thank you.

  • @franciscobanda6090
    @franciscobanda6090 14 дней назад

    Great video. Do you know if a Generac home standby remote start kit will work to integrate generator to a mango power inverter?

  • @milusosandmore7506
    @milusosandmore7506 17 дней назад

    You just wasted your money for no reason, and created more trouble than necessary. What is the purpose of that smart if you don’t need it or if there’s not use for it? By the time you buy your batteries that divece it’s gonna be obsolete.

  • @Doc02864
    @Doc02864 22 дня назад

    I have an electric only boat for X 12 V off grid trying to charge the batteries with four solar panels once a week. I thought I could run the iq8 off grid but still not sure. Anyone know of a good way to charge my boat batteries?

  • @johntorrey8589
    @johntorrey8589 Месяц назад

    That is the benefit of Pure Lead Premium AGM Fullriver Batteries ! They will recover from deep discharge, it is built into the DNA of the battery.

  • @ssoffshore5111
    @ssoffshore5111 Месяц назад

    One of the few installs where I dont see a raceway under the 15k, looks better without the big raceway IMO. Seems like almost all professional installers use them though... Any reason for going this route?

  • @JoeAndolina
    @JoeAndolina 2 месяца назад

    You are killing me, I wish I saw this video when I started. My battery is planned for phase two. I scanned my smart switch and had to go through ALL the hoops to finally get it running without the battery.

  • @pinktacotuesday4573
    @pinktacotuesday4573 3 месяца назад

    Whens the new iq5p with the new 3g smart switch and combiner box 5 video dropping?

  • @ryanlonghurst-solar3467
    @ryanlonghurst-solar3467 4 месяца назад

    Great idea! Do you prefer conduit over a gutter box, or was an outdoor one just not available?

  • @teemum.9023
    @teemum.9023 4 месяца назад

    Price 30000. Six panels will not charge that battery full

    • @CascadeSolarAndElectric
      @CascadeSolarAndElectric 4 месяца назад

      This system has 18 modules and charges the battery full in less than half of the day.

  • @user-xc3ec8cm1k
    @user-xc3ec8cm1k 5 месяцев назад

    hola como estas como puedo contactarte

  • @wastenotwantnot5953
    @wastenotwantnot5953 5 месяцев назад

    Did the solar installers add the Smart Switch to the plan or did you have to request it? I'm wondering if it's included in setups by default or is it something extra... Also, if it's not "scanned in" does it still work or do you have to wait until you get the battery to get the benefit?

    • @CascadeSolarAndElectric
      @CascadeSolarAndElectric 5 месяцев назад

      Yes the smart switch was added into the overall plans. The switch essentially works in bypass mode until a battery is added. If the switch is scanned in without a battery the entire account locks you out and won’t let you finalize your system commissioning until a battery is added.

  • @shaynethomas3636
    @shaynethomas3636 6 месяцев назад

    I was thinking about setting up like this and waiting for bidirectional charging in lieu of batteries. Would this system support using the EV battery?

  • @clivebrown400
    @clivebrown400 6 месяцев назад

    Did you really need to connect to the inverter as a part of the shutdown, or would connecting only to the transmitter be enough to do the shutdown?

  • @hendersonsobers396
    @hendersonsobers396 6 месяцев назад

    Your setup looks really clean and tidy. Great job.

  • @adtreatment2892
    @adtreatment2892 6 месяцев назад

    Smash that like button

  • @torahislife
    @torahislife 6 месяцев назад

    Is this your business or residence? It sounds like an industrial plant!

    • @CascadeSolarAndElectric
      @CascadeSolarAndElectric 6 месяцев назад

      This system replaced an old 24V Outback system at a clients home. We rewired the solar modules from strings of 1 to strings of 6 and added this power station which can be expanded in any way they need.

  • @quickquote1568
    @quickquote1568 6 месяцев назад

    I would never install a high frequency, transfotmerless inverter in my off grid home. Transformerless, high frequency inverters offer a substantially lower surge capacity, a shorter life expectancy and run much hotter than heavy duty, low frequency, transformer based inverters. And their fans are louder because they run hotter.

    • @URackADisciprine
      @URackADisciprine 6 месяцев назад

      The majority of what you said USED to be true. Luxpower (manufacturer of EG4 inverters) has HF inverters that have generated over 100MWh (yes, 100,000kWh) of energy which are still operating optimally to this day. Surge capabilities and life span have dramatically increased in the last few years as well. Hence warranty period increases. Many inverters are still lousy with fan noise, I admit. LF inverters are still great for heavy inductive loads, but they are no longer the end all be all they used to be. Especially for the typical homeowner who only has one AC unit to contend with. No problem for more than one if they have inverter driven AC units or soft starts at the very least. Put two or three inexpensive HF 240V stand alone inverters on the wall sharing the loads and they can last a very long time generating a large amount of energy. This also gives you redundancy in case one fails till you can replace it which will be fast since most are AIO's now days. No reason to keep bashing systems that are now proven with many years of service like Sol-Ark, just makes you look bitter.

    • @hicapengrs
      @hicapengrs 6 месяцев назад

      I have had two HF inverters on my wall for 4 years now. They have produced many kilowatthours of energy and are still going strong. They have already paid for themselves at least twice. No problems running my 4-ton AC either.

    • @quickquote1568
      @quickquote1568 6 месяцев назад

      Two high frequency inverters in what sort of application? Grid Tie, off grid, emergency battery backup? What brand and what kW rating? Thanks.@@hicapengrs

    • @quickquote1568
      @quickquote1568 6 месяцев назад

      What I said still hold true today. High frequency, transformerless inverter offer a shorter life expectancy and they offer a lower surge capacity, when compare to low frequency, transformer based inverters. Both EG4 and the Sol-Ark have not been on the market long enough to prove their longevity. Signature Solar, importers of the EG4 inverter has only been in business for approximately 3 years and Portable Power LLC, the alleged manufacturers of the Solar-Ark line of inverters has only been in business for 7 years. Both relative newbies to the inverter industry when compared to major inverter manufacturers like Schneider Electric, Outback Power and Magnum Energy to name a few. I've been in this industry repairing both transformerless and transformer based inverters for the past 24 years and based on that experience, I can confirm that little has changed in the design of high frequency, transformerless inverters. I can also tell you that a mere 200% surge capacity is hardly an improvement from these inverter's original surge rating design, especially when you consider that most inductive loads require at least a 300% to 800% surge capability. Oh, and I'm not bashing anyone's product. I'm just educating the public on the true capabilities of these products. Besides, why would I intentionally bash anyone's high frequency inverter product? After all, the more of these light duty, high frequency inverters that are sold, and fail after a few years of use, the more customer's my inverter repair center acquires. @@URackADisciprine

    • @URackADisciprine
      @URackADisciprine 6 месяцев назад

      @@quickquote1568 LOL...bitter much? Must be if you have to twist someone's words to suit your agenda. Adios.

  • @mocdas
    @mocdas 7 месяцев назад

    What is the meaning of "scan in", please?

    • @CascadeSolarAndElectric
      @CascadeSolarAndElectric 6 месяцев назад

      When you commission an Enphase system using the installer app you “scan in” all the devices into the app. Once the system controller is scanned in you can’t go back.

  • @user-nf5zt4kr6p
    @user-nf5zt4kr6p 8 месяцев назад

    how are the batteries doing now 6 months later?

  • @smithrb
    @smithrb 9 месяцев назад

    Can you provide the epo plus 2 contactor part numbers you used for this? thank you.

  • @rowdyroy3566
    @rowdyroy3566 10 месяцев назад

    Do we need to install separately Transmitter PLC for Sol ark 12k Inverter?

    • @CascadeSolarAndElectric
      @CascadeSolarAndElectric 6 месяцев назад

      Yes, the Sol Ark inverter pins do not support the higher energy requirements that the new tigo rsd uses.

  • @SUNofNY
    @SUNofNY 10 месяцев назад

    Thank You!! Small channels don't get promoted or paid what they are worth, but for all of us little people, this information is gold.

  • @jordansage9655
    @jordansage9655 10 месяцев назад

    Great video. Enphase is kind of dumb with the commissioning issue you mentioned...

  • @CascadeSolarAndElectric
    @CascadeSolarAndElectric 11 месяцев назад

    The disconnect is for the Utility. They require a knife handle visible open lockable disconnect.

  • @ElJomoL
    @ElJomoL 11 месяцев назад

    Why have the Manual AC Disconnect under the IQ Combiner, when you have the Rapid Shutdown Switch just to its left. It is redundant.

    • @CascadeSolarAndElectric
      @CascadeSolarAndElectric 10 месяцев назад

      Our utility requires an external knife handle lockable visible open disconnect.

  • @unionse7en
    @unionse7en 11 месяцев назад

    If you have your inverter & shutdown switches mounted on the detached garage... do you still need a shutdown switch on/at the house service entrance area?

    • @CascadeSolarAndElectric
      @CascadeSolarAndElectric 11 месяцев назад

      The service entrance is at the detached garage. The feed through goes over to the house.

  • @rickrude9523
    @rickrude9523 Год назад

    Excellent advice.Quite a bit of cash to spend only to find out it is irreversible and would render your system useless.Seems like Enphase gets you by the "orbs", I like Enphase stuff but as you said there are way too many add ons as compared to other hybrids.

  • @NasaRacer
    @NasaRacer Год назад

    With the Enphase Rapid Shutdown switch is the other "PV AC Disconnect" box still required? The design for our (California) Enphase IQ8 system with 2 IQ 10T batteries only has the Enphase Rapid Shutdown switch mounted near our original grid service entrance and main panel. All other Enphase equipment (Solar Combiner and Gateway) are inside our garage. Does my solar installer have the system design wrong? Thanks

  • @caitlyndisanto5367
    @caitlyndisanto5367 Год назад

    Looks great! Will reference this in the future for my system

  • @ericconner2745
    @ericconner2745 Год назад

    Nice system. I've been thinking about doing one of these.

  • @ericconner2745
    @ericconner2745 Год назад

    Looks like a good setup! Why are the batteries wired in series?

  • @eekedout
    @eekedout Год назад

    Why did you not use the 12v supply off the sol-ark or the control circuit to the RSS transmitter?

    • @CascadeSolarAndElectric
      @CascadeSolarAndElectric Год назад

      The 12V supply off the solark will not power the new tigo transmitter. The pins 15 and 16 are underpowered by around 500mA.

    • @eekedout
      @eekedout Год назад

      Even on a 15k?

    • @CascadeSolarAndElectric
      @CascadeSolarAndElectric Год назад

      ​@Robert Giudice Page 22 of the December 9th 2022 edition of the solark manual finally correctly states that the pins inside the user area of even the 15k are not compatible with the tigo transmitter.

    • @eekedout
      @eekedout Год назад

      They’ll fix it one day.