- Видео 306
- Просмотров 1 859 218
HVAC Tech Knowledgy
США
Добавлен 25 мар 2021
Welcome to the HVAC Tech Knowledgy RUclips channel. I post videos of HVAC service calls, HVAC troubleshooting and HVAC knowledge for beginner and seasoned technicians.
Be sure to subscribe for HVAC tips, tricks, tool/product reviews and discussions!
Be sure to subscribe for HVAC tips, tricks, tool/product reviews and discussions!
Sometimes you got to deal with sewage! How to clear main Plumbing line with Drain Snake
Hey gang, this is just a quick video covering my ordeal clearing a main sewage line with a drain snake definitely outside of the scope of HVAC but thought it could help someone out to share. Let me know if you think the comments below thanks! 
Просмотров: 281
Видео
Diagnosing Cracked Furnace Heat Exchanger Turbulent Flames with Blower Flame Rollout and Corrosion
Просмотров 25814 дней назад
Thanks for watching! Feel free to use the affiliate links below if you’d like to help support the channel. I make a very small commission if you purchase through the links - Thanks! TOOLS I USE Klein Tools 3-in-1 Impact Flip Socket - amzn.to/35xOLdH Fieldpiece SC680 - Wireless Power Clamp Meter - amzn.to/3FsPIjP Testo 770-3 Digital MultiMeter - amzn.to/3qxVA6V Fieldpiece JL3KM2 Job Link Dual Ma...
Toptes CT-580 Carbon Monoxide Detector for homeowners and HVAC techs alike!
Просмотров 16521 день назад
The CT-580 is a portable, handheld carbon monoxide detector designed to suit the needs homeowners and HVAC techs. This is one of the most versatile CO detectors in the market today,monitor CO levels in any environment with data logging and three separate alarm modes. I’m definitely super happy with this product so far. Let me know if you guys have any experience with this product in the co...
Winter Furnace Maintenance Service Found & Repaired Gas Leak day in the life HVAC tech service calls
Просмотров 22721 день назад
Thanks for watching! Feel free to use the affiliate links below if you’d like to help support the channel. I make a very small commission if you purchase through the links - Thanks! TOOLS I USE Klein Tools 3-in-1 Impact Flip Socket - amzn.to/35xOLdH Fieldpiece SC680 - Wireless Power Clamp Meter - amzn.to/3FsPIjP Testo 770-3 Digital MultiMeter - amzn.to/3qxVA6V Fieldpiece JL3KM2 Job Link Dual Ma...
Patching Leaking Vapor Line & Evaporator Coil Replacement on Lennox Rheem Heat Pumps Day In The Life
Просмотров 284Месяц назад
Thanks for watching! Feel free to use the affiliate links below if you’d like to help support the channel. I make a very small commission if you purchase through the links - Thanks! TOOLS I USE Klein Tools 3-in-1 Impact Flip Socket - amzn.to/35xOLdH Fieldpiece SC680 - Wireless Power Clamp Meter - amzn.to/3FsPIjP Testo 770-3 Digital MultiMeter - amzn.to/3qxVA6V Fieldpiece JL3KM2 Job Link Dual Ma...
Failed Relay on Apt Air Handler HVAC Tech Diagnostic Call Day in The Life no heat service call
Просмотров 679Месяц назад
Thanks for watching! Feel free to use the affiliate links below if you’d like to help support the channel. I make a very small commission if you purchase through the links - Thanks! TOOLS I USE Klein Tools 3-in-1 Impact Flip Socket - amzn.to/35xOLdH Fieldpiece SC680 - Wireless Power Clamp Meter - amzn.to/3FsPIjP Testo 770-3 Digital MultiMeter - amzn.to/3qxVA6V Fieldpiece JL3KM2 Job Link Dual Ma...
Check Failed Contactor w/Multimeter Resistance/Ohms Shorted vs Opened Coil
Просмотров 219Месяц назад
Thanks for watching! Feel free to use the affiliate links below if you’d like to help support the channel. I make a very small commission if you purchase through the links - Thanks! TOOLS I USE Klein Tools 3-in-1 Impact Flip Socket - amzn.to/35xOLdH Fieldpiece SC680 - Wireless Power Clamp Meter - amzn.to/3FsPIjP Testo 770-3 Digital MultiMeter - amzn.to/3qxVA6V Fieldpiece JL3KM2 Job Link Dual Ma...
Customer had no Idea how Dangerous this was Major Gas Leak in Attic goes unnoticed for Years
Просмотров 3 тыс.Месяц назад
Thanks for watching! Feel free to use the affiliate links below if you’d like to help support the channel. I make a very small commission if you purchase through the links - Thanks! TOOLS I USE Klein Tools 3-in-1 Impact Flip Socket - amzn.to/35xOLdH Fieldpiece SC680 - Wireless Power Clamp Meter - amzn.to/3FsPIjP Testo 770-3 Digital MultiMeter - amzn.to/3qxVA6V Fieldpiece JL3KM2 Job Link Dual Ma...
Failed Attempt at Zone Damper Install HVAC Duct Work Attic Hack Job HVAC Day in the life
Просмотров 465Месяц назад
Thanks for watching! Feel free to use the affiliate links below if you’d like to help support the channel. I make a very small commission if you purchase through the links - Thanks! TOOLS I USE Klein Tools 3-in-1 Impact Flip Socket - amzn.to/35xOLdH Fieldpiece SC680 - Wireless Power Clamp Meter - amzn.to/3FsPIjP Testo 770-3 Digital MultiMeter - amzn.to/3qxVA6V Fieldpiece JL3KM2 Job Link Dual Ma...
Deadly Carbon Monoxide Levels caused by Misaligned Burner Assembly Over 1000ppm HVAC Training Videos
Просмотров 7962 месяца назад
Thanks for watching! Feel free to use the affiliate links below if you’d like to help support the channel. I make a very small commission if you purchase through the links - Thanks! TOOLS I USE Klein Tools 3-in-1 Impact Flip Socket - amzn.to/35xOLdH Fieldpiece SC680 - Wireless Power Clamp Meter - amzn.to/3FsPIjP Testo 770-3 Digital MultiMeter - amzn.to/3qxVA6V Fieldpiece JL3KM2 Job Link Dual Ma...
Hot Surface Ignitor and Control Board Replacement on 90% Gas Furnace HVAC Tech Service Calls
Просмотров 4462 месяца назад
Thanks for watching! Feel free to use the affiliate links below if you’d like to help support the channel. I make a very small commission if you purchase through the links - Thanks! TOOLS I USE Klein Tools 3-in-1 Impact Flip Socket - amzn.to/35xOLdH Fieldpiece SC680 - Wireless Power Clamp Meter - amzn.to/3FsPIjP Testo 770-3 Digital MultiMeter - amzn.to/3qxVA6V Fieldpiece JL3KM2 Job Link Dual Ma...
Inspect Furnace w/ KAIWEETS KBA01 Two-Way Articulating Borescope #havc #borescope #inspectioncamera
Просмотров 1792 месяца назад
15% off code: JAG56EZ3 (Combines with the coupon displayed on product page.) Date of expiry: 11-30-2024 Buy from Amazon: www.amazon.com/dp/B0D9M3Q7FK 15% off code: HTK15 (Available sitewide at Kaiweets.com and it never expires.) Buy from official webstore: kaiweets.com/products/kba01-two-way-articulating-borescope?sca_ref=5465332.UihvFeHq1G More offerings from Kaiweets: kaiweets.com/collections...
Hard to Find Low Voltage Short On Roof op Package Unit
Просмотров 3802 месяца назад
Thanks for watching! Feel free to use the affiliate links below if you’d like to help support the channel. I make a very small commission if you purchase through the links - Thanks! TOOLS I USE Klein Tools 3-in-1 Impact Flip Socket - amzn.to/35xOLdH Fieldpiece SC680 - Wireless Power Clamp Meter - amzn.to/3FsPIjP Testo 770-3 Digital MultiMeter - amzn.to/3qxVA6V Fieldpiece JL3KM2 Job Link Dual Ma...
How to Diagnose Bad Circuit Board on 80% Gas Furnace
Просмотров 3373 месяца назад
Thanks for watching! Feel free to use the affiliate links below if you’d like to help support the channel. I make a very small commission if you purchase through the links - Thanks! TOOLS I USE Klein Tools 3-in-1 Impact Flip Socket - amzn.to/35xOLdH Fieldpiece SC680 - Wireless Power Clamp Meter - amzn.to/3FsPIjP Testo 770-3 Digital MultiMeter - amzn.to/3qxVA6V Fieldpiece JL3KM2 Job Link Dual Ma...
Air Handler Control Board Completely Fried HVAC Tech Bad Control Board Repair
Просмотров 4053 месяца назад
Air Handler Control Board Completely Fried HVAC Tech Bad Control Board Repair
How on Diagnose a Bad Suction Line Temp Gas Sensor Failure on Trane TAM9 Variable Speed System
Просмотров 3053 месяца назад
How on Diagnose a Bad Suction Line Temp Gas Sensor Failure on Trane TAM9 Variable Speed System
How to find a HVAC Refrigerant Leak using a Ultrasonic and Electrolyte Leak Detector
Просмотров 2614 месяца назад
How to find a HVAC Refrigerant Leak using a Ultrasonic and Electrolyte Leak Detector
90% Lennox Furnace Installed in Tight Crawlspace P Trap Solution for Condensate Trap install
Просмотров 2014 месяца назад
90% Lennox Furnace Installed in Tight Crawlspace P Trap Solution for Condensate Trap install
Using the CPS Easyflow Flow Hood Check Airflow on a Zone System HVAC Tech
Просмотров 2354 месяца назад
Using the CPS Easyflow Flow Hood Check Airflow on a Zone System HVAC Tech
My Honest Opinion on VETO Pro Pac Backpacks HVAC Tool Bag Demo Pt2
Просмотров 8974 месяца назад
My Honest Opinion on VETO Pro Pac Backpacks HVAC Tool Bag Demo Pt2
Veto MB5B Vs Veto Tech PAC Which Bag is Better for Service? HVAC Tool Bag Demo 
Просмотров 3,1 тыс.5 месяцев назад
Veto MB5B Vs Veto Tech PAC Which Bag is Better for Service? HVAC Tool Bag Demo 
Contactor NOT Contacting Heat Exchanger NOT Exchanging Heat HVAC Day in the Life No Cool Diagnostic
Просмотров 5975 месяцев назад
Contactor NOT Contacting Heat Exchanger NOT Exchanging Heat HVAC Day in the Life No Cool Diagnostic
Improper Capacitor Install Can Be Costly Mistake HVAC Tech Kills Compressor on Routine Maintenance
Просмотров 2,6 тыс.5 месяцев назад
Improper Capacitor Install Can Be Costly Mistake HVAC Tech Kills Compressor on Routine Maintenance
It Seems Every Rheem Heat Pump Leaks on this Spot!! Troubleshooting and Repairing Leaking Unit
Просмотров 9535 месяцев назад
It Seems Every Rheem Heat Pump Leaks on this Spot!! Troubleshooting and Repairing Leaking Unit
How Much Does an Undersized Filter Affect Air Flower Testing with TEC True Flow Grid
Просмотров 4955 месяцев назад
How Much Does an Undersized Filter Affect Air Flower Testing with TEC True Flow Grid
Cleaning Dirty Evaporator Coil on Trane Air Handlers with Supco Portablaster HVAC training videos
Просмотров 1,3 тыс.6 месяцев назад
Cleaning Dirty Evaporator Coil on Trane Air Handlers with Supco Portablaster HVAC training videos
Customer Wrongly Accuses Me of Stealing! Said I Stole Money During Service Call What Would You Do?
Просмотров 1,7 тыс.6 месяцев назад
Customer Wrongly Accuses Me of Stealing! Said I Stole Money During Service Call What Would You Do?
Ohming Out Shorted a Contactor with Multimeter HVAC Training Videos
Просмотров 4016 месяцев назад
Ohming Out Shorted a Contactor with Multimeter HVAC Training Videos
Watch Before Buying HVAC Tools I Regret Buying vs Best HVAC Tool Purchases HVAC Tech Tool Review
Просмотров 5 тыс.6 месяцев назад
Watch Before Buying HVAC Tools I Regret Buying vs Best HVAC Tool Purchases HVAC Tech Tool Review
Honest technician We need more like him out there Thank you. Keep up the great job
A pound?
This video really saved my family today. -18F outside and my furnace decided not to work. Your explanation of how to diagnose this gas valve was exactly what I needed as a basic handyman with no experience fixing Furnaces. Thank you
I got my associate degree in HVAC. A complete waste and didn't give me any edge in getting a job.
Ac guys watching other ac guys do plumbing. You’re a better man!
Excellent find, what I want to know is who's the mook that put the strainer behind drywall?
. HVAC system is 30 years old. The only time the condensate drain plugged was because of ice in the winter. Has a condsenate pump hooked to line for AC, furncace and humidifier, never has clogged. It drains to inside drain.
You are the king of Clamp Meters
my Lennox will just light up kicks the burners on for 5 sec then turns off. any help please? I cleaned burner box, and sensor and still no luck. thank you in advance!!
Very thorough. Question, how do you know the Ohms at which it should be at? Is there some sort of chart?
How much is the EST, To have this replaced P@L. I was told 900.00!
please what's the name of this app
Just get a Plumber out bro
He definitely not a plumber but he a bad ass hvac guy
You could film from further back so we can see where and what you are working on.
do you recommend going to trade school or college? imstuck in this situation where i dont know what to do but i know i want to get in a trade i just dont know where to start
If you don’t have an in or know anyone in the industry. Start applying to local companies. Walk in shake hands with the owners or manager whoever will see you applying online is for skilled tradesmen - guys who have been in for 5-10 years. You may have to start at a small business and climb up. I would ask them if they are looking for help. If that all fails go to trade school. Based on your individual circumstances You will have to take loans and pay to play or pay outright for trade school. If you feel you’re not college material don’t go. Trades are great once you get in and do what you have to do to climb.
Dude. This is not anything new. We all know how to put a nutdriver from a klein or other tool sets into the drill. It's not a mod either.
Really appreciate your clear explanation . Thank you
I had a carrier furnace that when I would run just the blower and use a barbecue lighter in the burner inlet on the far right it would push the flame back a bunch. But when the furnace would run it was fine. Come to find out the carrier furnace has an insulated gasket that just must of been letting air from the blower push pass.
At 0:36, you are missing a screw and thats what's causing that flame to dance. That is not a cracked heat exchanger
Crazy! are you talking about the screw that's missing where the heat exchanger Inlet connects to the burner assembly? This is a reupload it's probably a 3 or 4 year old video so I don't remember if I verified with a visual inspection or not. But I imagine that could have been the issue, I didn't even notice it. definitely appreciate you catching that!
@HVACTechKnowledgy i came across one and i put a screw in and the flame was perfectly fine. Give it a try, remove the screw from another furnace and let me know what you come across. I noticed the screw missing on a trane ane carrier.
The mp3 has a shoulder strap the sell
The camera 📷 man sucks🤨
Thanks for video. Ever run into a tam9 heat pump running fine in cooling but kicking off and on / short cycling due to suction running high pressure
Merci!
Thanks a lot really appreciate the support!🙂
Nice catch
Might be illegally
thanks for your video. Watched a dozen videos prior. They helped diagnose the overall system but this video helped me conclude my gas valve has an internal short. Thanks for the help. It's 6F out and 40F indoor. Hoping to swap it out and have it fixed tomorrow.
Who tf goes to copper for gas!?
Hey there! Probably about 99% of the newer homes built in the last 30 years or so that I've serviced here in the Carolinas use copper for gas. I always thought it was strange that the 2 PSI (newer) meters use copper but the quarter PSI meters use steel but that's the norm here. I imagine it would have to do with Copper's resistance to corrosion and malleability. Appreciate the feedback and thanks for watching
I think that was wonderful I am new at doing maintenance for a lot of things and I didn't put them white sleeves on their extenders and I got nothing but problems again and I had the same problem they did not give me a long enough bolt. They definitely didn't think that's through thank you for the video
I thought that was checking inducer motor
Love the ingenuity. :D
🔥
That prefabricated trap on the side is notorious for getting sediment & crud deep in it. Had me running round & round till I took it completely off & blew it out with compressed air twice. (I didn’t do a good job the first time) That crud in the trap backed up the condensate water into the system causing a pressure switch code.
That was a blockage for a plumber I reckon. Nice job finding it.
Thanks for the video, looking forward to a service call so I can a Hero..lol.
Kaiweets vs themisto which is better
what was the cost of repair like this ?
Bro, testo 310 is enough for residential right?
I just got my EPA certification
I have exactly the same issue, my valve has different resistance and it shorts when engaged... Your video confirmed my suspicions, thanks! BTW, can I just swap the coil (plastic) part w/o disconnecting gas pipes? EDIT: so there's no reason to replace that whole thing, in fact, no reason for new valve. Also, measuring it will not do any good since there's a bridge and a capacitor inside so results will vary. In my case, the problem was shorted diode in the bridge, so I replaced them all (4x 1N4007, <$1) Will post a video later on
What about the temp change across the strainer? You think there was a blockage there as well?
I did hvac before then I started driving truck now I’m thinking about going back to the hvac field
Use it everyday almost when condensers are slammed to the wall lol. Its a must have
Is this a testing method before cleaning or replacing a flame sensor.
Good video I think you would get more views if you said it was a comparison video though. That’s what I was looking for but I couldn’t find one so I tried yours out. Thanks for the info!
Thx for post this man i was on a unit and couldn't find the problem until watch this thanks God Bless You❤
Never seen one of those but I use thin pins and my meter is just inline with the FS while it still runs
What not to do when you smell gas and look for the leak. Open up any and all windows and doors to ventilate the area. Rookie was lucky he didn't end up on the street embedded in the roof.