Transmission Line Current Differential Protection | Example Using the SEL-411L Protective Relay
Online Courses: www.romeroengineering.co/courses
Check out our free resources at: www.romeroengineering.co/resources
Download our free 28-page power system protection fundamentals text-based course: www.romeroengineering.co/protection-and-control-fundamentals
In this video we go over how to set up a transmission line current differential scheme (87L) for transmission line protection using the SEL-411L protective relay.
Sign up to our online course subscription at:
www.romeroengineering.co/offers/FRPvBQDG/checkout
Book a one-on-one training session with Ricardo:
www.romeroengineering.co/offers/ZEo7VkVz/checkout
00:00 Intro
00:59 Intro to line current differential (87L) protection schemes
10:09 Line ...
Просмотров: 5 224

Видео

Directional Control in Protective Relays | How to Set Directional Elements in SEL Protective Relays
Просмотров 5 тыс.6 месяцев назад
Online Courses: www.romeroengineering.co/courses Check out our free resources at: www.romeroengineering.co/resources Download our free 28-page power system protection fundamentals text-based course: www.romeroengineering.co/protection-and-control-fundamentals In this video we go over how to set up a directional control element and use it to torque control a ground inverse-time overcurrent eleme...
Symmetrical Components Calculator | Phase to Sequence and Sequence to Phase Components Conversion
Просмотров 2,2 тыс.6 месяцев назад
Download the symmetrical components calculator: www.romeroengineering.co/symmetrical-components-calculator Online courses: www.romeroengineering.co/courses Symmetrical components online course: www.romeroengineering.co/courses-symmetrical-components-for-power-system-protection-engineers In this video we go over how to use our symmetrical components calculator for converting phase components to ...
ETAP Software Tutorial | Performing Load Flow (Power Flow) Studies Using the ETAP Software
Просмотров 7 тыс.Год назад
Download our free 28-page power system protection fundamentals text-based course: www.romeroengineering.co/protection-and-control-fundamentals Online Courses: www.romeroengineering.co/courses ETAP power system modeling video: ruclips.net/video/4QC9jvaGRyI/видео.html In this video we go over how to run a load flow (power flow) study using the ETAP software in an example 230kV/13.8kV substation, ...
Synchronism Check Elements in Protective Relays | Example Using the SEL-411L Protective Relay
Просмотров 7 тыс.Год назад
Online Courses: www.romeroengineering.co/courses Check out our free resources at: www.romeroengineering.co/resources Download our free 28-page power system protection fundamentals text-based course: www.romeroengineering.co/protection-and-control-fundamentals In this video we go over how to program a synchronism check element using the SEL-411L protective relay. Sign up to our online course sub...
Switch-Onto-Fault (SOTF) Scheme Basics | Example Using the SEL-411L Protective Relay
Просмотров 6 тыс.Год назад
Online Courses: www.romeroengineering.co/courses Check out our free resources at: www.romeroengineering.co/resources Download our free 28-page power system protection fundamentals text-based course: www.romeroengineering.co/protection-and-control-fundamentals In this video we go over how to program a switch-onto-fault scheme for transmission line protection using the SEL-411L protective relay. ...
ETAP Software Tutorial | How to Model Protective Relays Using the ETAP Software
Просмотров 9 тыс.Год назад
Download our free 28-page power system protection fundamentals text-based course: www.romeroengineering.co/protection-and-control-fundamentals Online Courses: www.romeroengineering.co/courses ETAP power system modeling video: ruclips.net/video/4QC9jvaGRyI/видео.html In this video we go over how to model protective relays using the ETAP software in an example 230kV/13.8kV substation and how to p...
Restricted Earth Fault (REF) Protection Basics | Example Using the SEL-487E Protective Relay
Просмотров 7 тыс.Год назад
Transformer Protection Online Course: www.romeroengineering.co/courses-power-system-protection-transformer-protection Online Courses: www.romeroengineering.co/courses Download our free 28-page power system protection fundamentals text-based course: www.romeroengineering.co/protection-and-control-fundamentals In this video we go over how restricted earth fault (REF) protection works using the SE...
Loss of Field Protection of Synchronous Generators | Example Using the SEL-300G Protection Relay
Просмотров 4,6 тыс.Год назад
Loss of Field Protection of Synchronous Generators | Example Using the SEL-300G Protection Relay
Automatic Reclosing in Power System Protection | Example Using the SEL-351S Protection Relay
Просмотров 5 тыс.Год назад
Automatic Reclosing in Power System Protection | Example Using the SEL-351S Protection Relay
Induction Motor Differential Protection Basics | Example Using the SEL-710 Protection Relay
Просмотров 3,5 тыс.Год назад
Induction Motor Differential Protection Basics | Example Using the SEL-710 Protection Relay
ETAP Software Tutorial | Performing Short Circuit and Protection Coordination Studies in ETAP
Просмотров 25 тыс.Год назад
ETAP Software Tutorial | Performing Short Circuit and Protection Coordination Studies in ETAP
ETAP Software Tutorial | Introduction to Modeling Power Systems Using the ETAP Software
Просмотров 38 тыс.Год назад
ETAP Software Tutorial | Introduction to Modeling Power Systems Using the ETAP Software
Calculating Trip Times of SEL and IEEE Inverse-Time Overcurrent Protection Curves
Просмотров 4,4 тыс.Год назад
Calculating Trip Times of SEL and IEEE Inverse-Time Overcurrent Protection Curves
Mho Ground Distance Protection | Example Using the SEL-411L Protection Relay
Просмотров 3,6 тыс.Год назад
Mho Ground Distance Protection | Example Using the SEL-411L Protection Relay
Breaker Failure Protection Basics | Example Using the SEL-751 Protection Relay
Просмотров 11 тыс.Год назад
Breaker Failure Protection Basics | Example Using the SEL-751 Protection Relay
Directional Comparison Blocking (DCB) Scheme Basics | Transmission Line Pilot Scheme Protection
Просмотров 4,4 тыс.Год назад
Directional Comparison Blocking (DCB) Scheme Basics | Transmission Line Pilot Scheme Protection
Permissive Overreaching Transfer Trip (POTT) Scheme Basics | Example Using the SEL-411L Relay
Просмотров 4,9 тыс.Год назад
Permissive Overreaching Transfer Trip (POTT) Scheme Basics | Example Using the SEL-411L Relay
Reverse Power Protection Basics | Example Using the SEL-751A Protection Relay
Просмотров 5 тыс.2 года назад
Reverse Power Protection Basics | Example Using the SEL-751A Protection Relay
Load Encroachment Function in Distance Protection | NERC PRC-023 Compliance of Distance Protection
Просмотров 4,4 тыс.2 года назад
Load Encroachment Function in Distance Protection | NERC PRC-023 Compliance of Distance Protection
Current Transformer Basics | Effects of CT Saturation on Protection Relays
Просмотров 13 тыс.2 года назад
Current Transformer Basics | Effects of CT Saturation on Protection Relays
Distance Protection of Transmission Lines | Example Using the SEL-421 Protection Relay
Просмотров 10 тыс.2 года назад
Distance Protection of Transmission Lines | Example Using the SEL-421 Protection Relay
Transformer Differential Protection | Calculating TAP Settings and Compensation Angles in SEL Relays
Просмотров 16 тыс.2 года назад
Transformer Differential Protection | Calculating TAP Settings and Compensation Angles in SEL Relays
Overcurrent Protection Basics | How to Set Overcurrent Elements in Protection Relays
Просмотров 16 тыс.2 года назад
Overcurrent Protection Basics | How to Set Overcurrent Elements in Protection Relays
How to Determine Protection Relay Logic Scheme Operation Using Truth Tables
Просмотров 3,8 тыс.2 года назад
How to Determine Protection Relay Logic Scheme Operation Using Truth Tables
Substation Bus Arrangements | Considerations for Protection Schemes in Substations
Просмотров 6 тыс.2 года назад
Substation Bus Arrangements | Considerations for Protection Schemes in Substations
Neutral Overcurrent (51N) Protection of Transformers | Ground Protection Coordination in Substations
Просмотров 5 тыс.2 года назад
Neutral Overcurrent (51N) Protection of Transformers | Ground Protection Coordination in Substations
Oneline and Threeline Drawings for Transformer Protection Relays - How to Design Protection Schemes
Просмотров 6 тыс.2 года назад
Oneline and Threeline Drawings for Transformer Protection Relays - How to Design Protection Schemes
Three-Phase Transformer Connections | Effects of Transformer Connections on Power System Analysis
Просмотров 2,4 тыс.2 года назад
Three-Phase Transformer Connections | Effects of Transformer Connections on Power System Analysis
Complex Power Flow in Power Systems - How to Calculate Apparent, Real, and Reactive Power
Просмотров 2,6 тыс.2 года назад
Complex Power Flow in Power Systems - How to Calculate Apparent, Real, and Reactive Power

Комментарии

  • @JJ18_M3
    @JJ18_M3 2 дня назад

    How would you create one for something that includes latches and PCTs?

  • @MechanicForGMCCars
    @MechanicForGMCCars 4 дня назад

    Hello I'm new to electronics so can some one please tell my magnet type alternators in cars would an transformer reduction work to 220v ? I mean can the stator leads 3phase by used to connect to an transformer 3phase to 2phase transformer I'm worried about high frequency I wanted to use external indisti type bridge rectifiers so I'm worried about over loading the stator leads inside the alternator just to run small projects .Preciseli I'm just looking at independent ignition system for an 4 cilinder engine with out baterry problems Basicali. So Hoppe some one did similar project in the past. I also want to use that magnet type alternator for back up in case I need inverter to run small machines or light bulbs when power is cutt off. So Hoppe for some sugestions ? I heard an solar panel regulator could by used so I'm not Shure if that would work or not .I'm mostli concerned about stator leads,over drag Hoppe to not brake pulley to engine connection and would avoid engine lagg from over load .

  • @soulofcinder2351
    @soulofcinder2351 6 дней назад

    What is the difference between TD and TMS

  • @DmV
    @DmV 9 дней назад

    Thank you for the video! I just want to know why you calculate the pickup for 51 prot as 1.25 of FLA? Which document describes this?

  • @patakotisrinivas1918
    @patakotisrinivas1918 10 дней назад

    Thanks for an awesome explanation

  • @WRXSCAPEINC
    @WRXSCAPEINC 10 дней назад

    great video!!! I like to learn more about motor protection relay and power quality calculation

  • @fgonz007
    @fgonz007 10 дней назад

    Why do we take 180% of the fault current on the low-side and reflect it to the high-side for 50P? It seems like we're taking extra steps. Couldn't we just take 180% of the maximum high-side fault current based on the transformer size?

  • @yassineallouche9844
    @yassineallouche9844 18 дней назад

    Undervoltage setting for MV ?

  • @benv.j6908
    @benv.j6908 20 дней назад

    Phenomenal video. Great explanation.

  • @saifikhan5936
    @saifikhan5936 22 дня назад

    Where is this slop and settings O87p comes from? Please answer

  • @rafaelbejarano3422
    @rafaelbejarano3422 22 дня назад

    Friend need this new version etap 22 please. Its possible?

  • @rafaelbejarano3422
    @rafaelbejarano3422 22 дня назад

    Friend need this new version etap 22 please. Its possible?

  • @rafaelbejarano3422
    @rafaelbejarano3422 22 дня назад

    Friend need this new version etap 22 please. Its possible?

  • @motivationarena9207
    @motivationarena9207 24 дня назад

    Please Create a video for substation Cap control

  • @Hatanpaa140
    @Hatanpaa140 Месяц назад

    Could you explain or make a video on open phase faults and sequence components. I have a very hard time finding material on when a phase opens but isn't connected to ground or another phase. If this happens, I'm curious on the symmetrical components and what they look like.

  • @MrOptimusPrime.
    @MrOptimusPrime. Месяц назад

    Just now i noticed my ETAP 16 is malfunctioning. For protection coordination, whatever values i enter in the differential relay properties box, vanishes once i press OK button. This happens for CT ratings too. When i tried to disable overcurrent protection, the same happened. Unable to set breakers to open. Everything works first. When i reopen the properties box, nothing is there. Everything is in the default value. And so breakers are not opening. What goes wrong.?

  • @CretusBathoromeo
    @CretusBathoromeo Месяц назад

    Technically manual book of this please

  • @Whitetooth1030
    @Whitetooth1030 Месяц назад

    I’m a Distribution Engineer and wanted to advance my Protection Coordination skillsets and this video helped me out a lot with Relay programming ! Great video 🔥

  • @MrOptimusPrime.
    @MrOptimusPrime. Месяц назад

    can i have three single phase transformers in place of a single 3 phase transformer.?

  • @myenergyprojects
    @myenergyprojects Месяц назад

    youtube.com/@myenergyprojects?si=BVtbeFARuwtDCxn2 please refere for all basics and knowledge information . Hi sorry for posting my channel link

  • @myenergyprojects
    @myenergyprojects Месяц назад

    youtube.com/@myenergyprojects?si=BVtbeFARuwtDCxn2 please refere for all basics and knowledge information . Hi sorry for posting my channel link

  • @myenergyprojects
    @myenergyprojects Месяц назад

    youtube.com/@myenergyprojects?si=BVtbeFARuwtDCxn2 please refere for all basics and knowledge information . Hi sorry for posting my channel link

  • @DanielNunesdeSousa-y8t
    @DanielNunesdeSousa-y8t Месяц назад

    How to model relays that are not in the library?

  • @surendrakverma555
    @surendrakverma555 Месяц назад

    Thanks Sir

  • @davenandrew7292
    @davenandrew7292 Месяц назад

    Thank you so much. Your Video is Gold❤

  • @bigmikec9
    @bigmikec9 Месяц назад

    I have a three phase CT’d service. The meter is showing reverse current. I swapped the polarity and it still shows reverse current. All of my kWh are showing received. What could be my problem?

  • @alexisriveracianchini3556
    @alexisriveracianchini3556 Месяц назад

    Great! do you know where i can find equation for IAC and CO electromechanical relays? please do a new video including electromechanical relays

  • @Arafat-u8l
    @Arafat-u8l Месяц назад

    Is 150% common for pick up current? I am used to seeing 125% on low voltage.

    • @Whitetooth1030
      @Whitetooth1030 Месяц назад

      125% is normal, 150% is more of this Engineers decision. Some Engineers add more percentage because they want to be 100% sure they don’t trip any operational load current.

  • @farosrohmangeloraramadan3897
    @farosrohmangeloraramadan3897 Месяц назад

    Please make another video and tell about differential relay program with FBD....!

  • @Rahmen_20
    @Rahmen_20 Месяц назад

    Nice video, its help me a lot to learn etap, thank you sir 😂

  • @maulinasavitri
    @maulinasavitri Месяц назад

    Incredible

  • @joshe5180
    @joshe5180 2 месяца назад

    A TRUE LEGEND. 10/10 INFO

  • @ImranKhan-nu6xw
    @ImranKhan-nu6xw 2 месяца назад

    Very nice

  • @ImranKhan-nu6xw
    @ImranKhan-nu6xw 2 месяца назад

    Appreciate you for this

  • @ImranKhan-nu6xw
    @ImranKhan-nu6xw 2 месяца назад

    Nice explaination dear

    • @myenergyprojects
      @myenergyprojects Месяц назад

      youtube.com/@myenergyprojects?si=BVtbeFARuwtDCxn2 please refere for all basics and knowledge information . Hi sorry for posting my channel link

  • @AliGh-u9k
    @AliGh-u9k 2 месяца назад

    I really appreciate your work. How can I simulate transformer REF protection in ETAP?

  • @jahangiralamkhan2236
    @jahangiralamkhan2236 2 месяца назад

    I am interested in your online courses. Please share the details.

    • @romeroengineering
      @romeroengineering 2 месяца назад

      Hi! You can sign up to our courses here: www.romeroengineering.co/offers/FRPvBQDG/checkout This subscription gives you access to all of our courses.

  • @jahangiralamkhan2236
    @jahangiralamkhan2236 2 месяца назад

    Thanks

  • @romanluis9908
    @romanluis9908 2 месяца назад

    Excellent and very helpful video, Thanks!

    • @myenergyprojects
      @myenergyprojects Месяц назад

      youtube.com/@myenergyprojects?si=BVtbeFARuwtDCxn2 please refere for all basics and knowledge information . Hi sorry for posting my channel link

  • @royblingas
    @royblingas 2 месяца назад

    Great video! It was very helpful.

  • @ВратарьРеспублики-д8х

    Hello mate, do you know any reason why SEL uses different algorithms of SLP1-SLP2 for 487E and 787 for example. In former, SLP2 begins from 0;0 origin, while for latter SLP2 is shifted to the right. Cheers

  • @nelsonnhavoto8060
    @nelsonnhavoto8060 2 месяца назад

    Like

  • @ugwaabraham6232
    @ugwaabraham6232 2 месяца назад

    Great presentation. Can you do a video on reliability analysis using eta?

  • @SaavaMark-i7w
    @SaavaMark-i7w 2 месяца назад

    thanks for the video if am to ask how, if am having a transformer which is connected in Delta at the primary winding and star at the secondary is it ok for me to connect the primary ct in star at the primary and Delta and the secondary to avoid the current phase shift thank you

  • @josephlaing5205
    @josephlaing5205 2 месяца назад

    JLAING WATCHING FROM WEST NASSAU

  • @AldoTorres-b4f
    @AldoTorres-b4f 2 месяца назад

    excelente

  • @normamando1479
    @normamando1479 2 месяца назад

    that was very helpful thanks!

  • @PokemonAseni
    @PokemonAseni 2 месяца назад

    why were current transformes used before CB. should not that used after circuit breaker

    • @romeroengineering
      @romeroengineering 2 месяца назад

      Hi. CTs should always look into the protected equipment and encompass the interrupting device. For example, the CTs for the transformer differential relay in this example should be on the top side of the high-side circuit breaker and bottom side of the low-side circuit breaker, both looking into the transformer. The CT on the main breaker for the bus differential relay should be on the top side of that breaker, therefore overlapping with the CT for the transformer differential relay. Hope this helps. -Ricardo.

  • @yosifrank842
    @yosifrank842 2 месяца назад

    Hi, is better to use 5A or 1A secondary core ? for 6CTs and 3 core balance CTs solution.

  • @vishveshpatel3932
    @vishveshpatel3932 3 месяца назад

    Excellent video on youtube about this topic. This channel seems underrated.