The Carbone Academy
The Carbone Academy
  • Видео 5
  • Просмотров 98 491
What is a PREVAC System on a low pressure chiller and how does it work?
For information on the PREVAC System:
1mic1.com/
For PREVAC Orders and inquiries:
andrew@1mic1.com
For training:
thecarboneacademy.com/
For training or video inquires:
training@thecarboneacademy.com
For NationalAssociation of Power Engineers NYSA:
www.powerengineers.com/nysa/
#hvac #refrigeration #nationalassociationofpowerengineers #refrigerationschoolnyc #tradeschool #chillers #engineering #nyc #zoomclasses #boilers #thecarboneacademy #yorkchillers #firepump #firealarm #airconditioning #steamengine #highpressuresteam #highpressureboiler #tranechillers
Просмотров: 854

Видео

How a service valve ( 3 way Valve ) Works
Просмотров 1,1 тыс.2 года назад
How a refrigeration service 3 way valve works. #hvac #refrigeration #nationalassociationofpowerengineers #refrigerationschoolnyc #tradeschool #chillers #engineering #nyc #zoomclasses #boilers #thecarboneacademy #yorkchillers #firepump #firealarm #airconditioning #steamengine #highpressuresteam #highpressureboiler #tranechillers
How to punch tubes on a fire tube boiler
Просмотров 1,8 тыс.3 года назад
Manually Punching Tubes on an Easco Hot Water Fire Tube Boiler. National Association of Power Engineers NYSA Education at The Carbone Academy. www.thecarboneacademy.com #hvac #refrigeration #nationalassociationofpowerengineers #refrigerationschoolnyc #tradeschool #chillers #engineering #nyc #zoomclasses #boilers #thecarboneacademy #yorkchillers #firepump #firealarm #airconditioning #steamengine...
How to Punch Tubes on a Condenser.
Просмотров 12 тыс.3 года назад
Punching Condenser Tubes on a York Centrifugal Chiller With A Goodway Tube Punching Machine. #hvac #refrigeration #nationalassociationofpowerengineers #refrigerationschoolnyc #tradeschool #chillers #engineering #nyc #zoomclasses #boilers #thecarboneacademy #yorkchillers #firepump #firealarm #airconditioning #steamengine #highpressuresteam #highpressureboiler #tranechillers
Starting A York Centrifugal Chiller
Просмотров 82 тыс.3 года назад
Starting an electric York 800 ton Centrifugal Chiller . #hvac #refrigeration #nationalassociationofpowerengineers #refrigerationschoolnyc #tradeschool #chillers #engineering #nyc #zoomclasses #boilers #thecarboneacademy #yorkchillers #firepump #firealarm #airconditioning #steamengine #highpressuresteam #highpressureboiler #tranechillers #

Комментарии

  • @hvac1688
    @hvac1688 Месяц назад

    感兴趣的学员 可以联系我 27 年工作经验

    • @hvac1688
      @hvac1688 Месяц назад

      If you are interested, contact me. (27 years experience, Q-01 Licensed since 1997)

  • @edsalem6800
    @edsalem6800 2 месяца назад

    I did that as part of my summer job back in the 70s. H. B. Smith boilers. Dirty work but had to earn money for school.

  • @rafa_br34
    @rafa_br34 3 месяца назад

    Thank you, I would not have known otherwise

  • @natureboy1313
    @natureboy1313 3 месяца назад

    Dude, by the look from the video. You and your crew take pride in a clean and well labeled plant. Prior U.S. Navy?

  • @Marvinzock34
    @Marvinzock34 4 месяца назад

    Satisfactory pumps sounds

  • @BritishEngineer
    @BritishEngineer 8 месяцев назад

    Hey. Why do you have national grid

  • @sparklyncool734
    @sparklyncool734 8 месяцев назад

    really helpful 3 years later thanks👍

  • @bksalkrook8716
    @bksalkrook8716 8 месяцев назад

    800 tons is not really that big i ran 1500 ton steam turbines 3 at a time ....the old timers would call us young guys push button engineers with these NEW york chillers just saying ive been operating chillers over 35 years !! great HVAC trade ,,,but no side work !!

    • @thecarboneacademy2615
      @thecarboneacademy2615 8 месяцев назад

      There is plenty of perdiem work out there for engineers with all the big management companies.

  • @boomcity4942
    @boomcity4942 9 месяцев назад

    I worked around these types of machines for over 40 years. Retired now I miss those machines. The sound is music to my ears. I did use ear protection.

    • @TheChillerGuysHub
      @TheChillerGuysHub 7 месяцев назад

      They are pretty damn cool, we have one of the coolest jobs

  • @christopherbarrett6408
    @christopherbarrett6408 9 месяцев назад

    Great education and training video

  • @dgolovaSH
    @dgolovaSH 9 месяцев назад

    what is the inner diameter of the tube?

  • @ashgonza92
    @ashgonza92 10 месяцев назад

    Machine rooms are scary man

  • @thivakaran8256
    @thivakaran8256 11 месяцев назад

    Hi can u explain me ...causes of trip the chiller then high temperature.... cooling tower have water ...what solution of the problem

    • @thecarboneacademy2615
      @thecarboneacademy2615 11 месяцев назад

      What type of chiller is it and what did the chiller trip on? Any codes on the display panel?

  • @douglasrangel749
    @douglasrangel749 Год назад

    Oi tudo bem?! Onde encontro cursos ensinando a fazer manutenção nesses equipamentos

  • @MohammadAli-zx6bs
    @MohammadAli-zx6bs Год назад

    Please help me

  • @x-pipeclean2348
    @x-pipeclean2348 Год назад

    Good job

  • @6ixss
    @6ixss Год назад

    How much energy/electricity/power needs this to start up ?

    • @Bobherry
      @Bobherry Год назад

      Starting up the amps depending on the size can go from 800-1000 amps

    • @6ixss
      @6ixss Год назад

      @@Bobherry ty!

  • @PERFEKT_VARIO
    @PERFEKT_VARIO Год назад

    These things are literally chilling

  • @bellidoify
    @bellidoify Год назад

    Sound like a 737 engines

  • @NanjingRicom
    @NanjingRicom Год назад

    Hello, I am a Chinese industrial water cooler manufacturer. Are you interested in talking?

  • @BambangIrawan-vw6dw
    @BambangIrawan-vw6dw Год назад

    Chiller 1000 TR pake Preon R berapa ya,,,

  • @phs84
    @phs84 Год назад

    Magnetic drive every day of the week

  • @bunnyman6321
    @bunnyman6321 Год назад

    Thanks for sharing

  • @Big_Chungus935
    @Big_Chungus935 Год назад

    I feel like if i press something wrong whole tank will explode

  • @gregmercil3968
    @gregmercil3968 Год назад

    I finally had my first exposure to a chiller the other night on an emergency after hours service call. It was a Trane Centravac centrifugal chiller, about maybe half the size of this one. Don’t remember the tonnage but it took something like 560 lbs of R22. I had no idea just how ridiculously loud these machines were until it roared back to life. My head still feels weird from it. 😆

    • @thecarboneacademy2615
      @thecarboneacademy2615 Год назад

      A Trane Centravac is a low pressure chiller so It most likely would not use R22 it was probably R123. But they are nice machines and its definitely a sound you will remember.

    • @gregmercil3968
      @gregmercil3968 Год назад

      @@thecarboneacademy2615 the data tag itself on the unit stated it uses R22. This was a “Series R” manufactured in 1996, and was on a hospital building, if that helps.

    • @thecarboneacademy2615
      @thecarboneacademy2615 Год назад

      You're positive it was a centravac? R22 is a high pressure refrigerant and would not typically be used in a low pressure chiller. Would usually be R123 or R1233zd. I would love to see that data plate if possible. This is very interesting.

    • @ZRock7771
      @ZRock7771 Год назад

      ​@@thecarboneacademy2615I thought r22 was a medium pressure refrigerant?

    • @craigr6186
      @craigr6186 Год назад

      R22 is high pressure, Trane only uses 11,123,1233zd and the last one is like two to three years old. R22 wasn’t really popular in centrifugals. York and Carrier over the years have used 11,12.134a,22 ( screw machines) York used 123 carrier didn’t. I worked for York and carrier for a total of 23 years

  • @justinperry68
    @justinperry68 Год назад

    How much R134A would this thing take to operate?

    • @imeakdo7
      @imeakdo7 Год назад

      Hundreds of pounds

  • @technicalsupport7291
    @technicalsupport7291 Год назад

    air called the chiller vacuum process. चिल्लर का वैक्यूम कैसे करते है ....... carrier chiller vacuum process # 30x chiller vacuum process # 30X chiller #air colled chiller air air colled chiller complaint # Display reading # inlet outlet # split AC # oil filter change

  • @Nighthawke70
    @Nighthawke70 Год назад

    Gotta love soft starts. A little surging initially, then it started to smooth out in the end, good. Nice splits on the input/output of your chill waters. You got a nice system going on there. Just the surging might be something to keep an eye on.

  • @firenado4295
    @firenado4295 Год назад

    damn sounds like the inside of a spaceship or something, pretty neat

    • @liam3284
      @liam3284 11 месяцев назад

      the foley effects for "spaceship" often use startup sounds from large industrial machines.

    • @mr23347
      @mr23347 Месяц назад

      The old carrier centrifugals I used to watch my dad crank when I was a kid back in 88 were spooky they would hum and when yould least expect it a light would come on and she'd spool up and off to the races.. the initial hum is the oil pump presuming then the indescribable whaaaaaa followed by the thrill of surviving of this purring monstrosity..rake a look. m.ruclips.net/video/TCZMxz9px2k/видео.html

  • @AbdulMateen-zo9gg
    @AbdulMateen-zo9gg Год назад

    How to find chiller tons please tell me

  • @thetoasterisonfire2080
    @thetoasterisonfire2080 2 года назад

    Finally something to properly cool my computer

  • @nc2ab2
    @nc2ab2 2 года назад

    Hello sir, can you tell me what is the tube cleaner brand and where buy it?

  • @northface484
    @northface484 2 года назад

    Your Chiller Room is amazing...!!!

  • @anthonyjavon1690
    @anthonyjavon1690 2 года назад

    Nice demonstration

  • @mansourghadhban236
    @mansourghadhban236 2 года назад

    Am design electric control for chiller when. Electronic device fault

  • @mansourghadhban236
    @mansourghadhban236 2 года назад

    Thnxs more am from Iraq

  • @salvadorbernardino7558
    @salvadorbernardino7558 2 года назад

    Excellent

  • @booransanatdena1379
    @booransanatdena1379 2 года назад

    Wow, just wow😀👍

  • @adamwatts6011
    @adamwatts6011 2 года назад

    Working on one similar to this next week. How bad is changing the oil with a hand pump? It holds 20 gallons . 134a machine the sump is located below my condenser fortunately so it’s easy access.

    • @thecarboneacademy2615
      @thecarboneacademy2615 2 года назад

      Yes most of the oil sumps are underneath the condenser. Changing oil should not be too difficult.

  • @Clasped003
    @Clasped003 2 года назад

    Hey great video! How do you retract the tube back with that gun? Do you just press the same trigger and it does it automatically?

    • @thecarboneacademy2615
      @thecarboneacademy2615 2 года назад

      The trigger has two positions press it up for one direction and then down for reverse direction.

  • @texture6
    @texture6 2 года назад

    Thank you

  • @JosephJuliaNyc
    @JosephJuliaNyc 2 года назад

    👌 thank you for sharing.

  • @harrybeta
    @harrybeta 2 года назад

    Hi which camera did you use to record the video?

  • @pett-bongsanchez9292
    @pett-bongsanchez9292 2 года назад

    I do like the video that you share, I hope to see more of your blog.

  • @woodydawson982
    @woodydawson982 2 года назад

    do you have a video on adding freon to one of these chillers. I have 3 in the hospital I work in and I have been tasked to troubleshoot. Ant info would be greatly appreciated.

    • @thecarboneacademy2615
      @thecarboneacademy2615 2 года назад

      Unfortunately we currently don’t have any refrigerant recovery videos available. We will try to create one.

    • @TheChillerGuysHub
      @TheChillerGuysHub 7 месяцев назад

      For putting gas in from flat, add vapor until it’s about 35#, then push pull it in. If your topping it off, then just run a hose from the tank to the evaporator barrel, and let er fly Make sure you do the opposite when recovering to make sure you don’t freeze the tubes!!!!

  • @toyinorodare4072
    @toyinorodare4072 2 года назад

    Thank you for the video

  • @SlickManChoux
    @SlickManChoux 3 года назад

    The water comes clean from the bottom tubes ,it means no sludge .l've done the same job on wooden mega boiler by hand metal brush cos the auto one is broken,It was a misery with ,heat and ash.Good job

  • @davepenprase
    @davepenprase 3 года назад

    Hey thanks that was cool lol

  • @SlickManChoux
    @SlickManChoux 3 года назад

    This is my job I luv it

  • @markstanley3534
    @markstanley3534 3 года назад

    Is their any chillers coming out of your building?