Gas Valve malfunction, get rid of flame cuts, Ariston gas boiler
Просмотров 16114 дней назад
Recently, my Ariston Genus One gas boiler started showing the 5p3 error code -flame cuts. I have an almost new PCB main board, so I was sure there was no problem. The suspect was the gas valve. The deformed membrane caused the flame cuts. Piston was no perfectly coaxial to selenoid coile. I have no idea what cause twisting membrane. Fix was simple, carefully get membrane to normal position. Sin...
Ariston Genus One - Gas valve malfunction, error code 5P3, flame cuts
Просмотров 9 тыс.11 месяцев назад
I found solution to solve problems with flame cuts...
Cleaning the heating element on the washing machine Electrolux
Просмотров 1,2 тыс.Год назад
While cleaning the drain hose on the washing machine, I also checked the heating element...
Nice RBA4 control unit , Nice RD400, electronic repaire
Просмотров 644Год назад
Try this to fix your Nice RBA4 unit
Ariston Genus One System 309, 303(also 5P3,5P6) error, PCB fix, read description!
Просмотров 31 тыс.2 года назад
Cap is soldered to pin 1 and 3, 1 and 2 is not shorted- it looks so, but is not!!! Use capacitor 1nF !!! not 22nF , is much stable and no more error codes. It will work also with 22nF capacitor, but sometimes will appear 5P3 error code. 309 error code mean "Gas relays check failed", I found that the cause of this error is a bad smd capacitor on pcb connected in parallel with gas valve selenoid....
Electrolux tumble dryer error code EH0- How to fix it.
Просмотров 43 тыс.2 года назад
EH0 code on Electrolux dryer means power supply problem, in my case fix was really easy as you can see, this was the first problem with this dryer after 5 years. Take out PCB, clean it and search for a cold joints....resolder, get PCB back in place, done.
Gas valve test SGV100
Просмотров 5 тыс.2 года назад
This is vid about how you can test your gas valve from Ariston and Baxi gas boilers and how it looks inside the valve. you need 12V DC power supply, some wiring to connect to valve pins, this gas valve has two selenoids, one controls the main gas inlet, the second modulates the outlet pressure - thats what you can see on video, this is electromechanical test only
Ariston Genus One System flame lifts 5P3, 501, 504, 309, 303 error code. To fix it read description
Просмотров 36 тыс.2 года назад
Some tips to fix this errors collected from my and other users experience : - clean ionizating electrode (more often when boiler is in laundry room) - clean condensate drain - check grounding and power supply (grounding resistance up to 13ohm is ok) - check gas valve selenoid resistance - ( Type SGV100: pin 1-3 : 25ohm, pin 2-4: 67ohm) !!!! UPDATE: my gas valve was getting stuck, not opening fu...

Комментарии

  • @gulagamikaylov2779
    @gulagamikaylov2779 22 дня назад

    Can i have your whatsapp, i want ask about it from photo?🙏

  • @MrFiguradaniel
    @MrFiguradaniel 3 месяца назад

    Hi can anyone what is the voltage ouput on 24V pin (pin 1) I measure 36 V there so not sure if my unit is faulty or not. Manual says 24 V (+50%, - 30%) which seems like in spec, but it burned a TX photocell - power BJT and 35 V cap. I am afraid that if I replace only the photocells it will happen again. Thanks.

  • @shadurskysergey
    @shadurskysergey 4 месяца назад

    EH0 реально - у меня та же причина... я не понял, у них что брак штампуют и никто не указывает им на этот недостаток пайки??? Michal Aron - ты красавчик!!! спасибо что поделился👍

  • @luk5827
    @luk5827 4 месяца назад

    PCB board it's the problem for all Ariston Alteas / Genus One gas boilers .

  • @twinsrule9527
    @twinsrule9527 4 месяца назад

    PROBLEMS SOLVED. THANK YOU SO MUCH.

  • @alexsupport2858
    @alexsupport2858 4 месяца назад

    Have same overheat and dont work same . Will try change campacitors thx for video much ...❤❤❤

  • @matiaspitu
    @matiaspitu 4 месяца назад

    What product do you use to clean parts?

  • @maciejmajcher5493
    @maciejmajcher5493 5 месяцев назад

    Hello. My Electrolux dryer heats but does not cool. The problem is that the laundry is hot and the water tank is empty. The compressor gets very hot. I would be grateful for any advice

    • @michalaron4784
      @michalaron4784 5 месяцев назад

      not sure, your dryer works, no errors pops up? but no water in tank, clogged pipe from water pump ?

    • @maciejmajcher5493
      @maciejmajcher5493 5 месяцев назад

      @@michalaron4784 I disassembled the entire dryer and cleaned it. Unfortunately, I suspect the lack of R134a refrigerant. What is disturbing is that there was some dried oil under the compressor.

  • @sankaman11000
    @sankaman11000 6 месяцев назад

    Fisrt defaut for me with this pcb : the regulator 5V TA78L005AL replace by 7805 in TO220 case most perform in hot temp. But today one new problem, i have replace 3 capicitors around the regulator but don't work correctly again. Have you the value of this burn resistor? Maybe it's down for me?

  • @miklosvarga8670
    @miklosvarga8670 6 месяцев назад

    I did the same one, successful one. Thank you

  • @rozzi667
    @rozzi667 8 месяцев назад

    how you diagnose which parts need to change?

    • @michalaron4784
      @michalaron4784 8 месяцев назад

      most common fault is bad capacitor, focusing on overheated parts, using common sense and learned electronics skils🥸

  • @aurelionita4734
    @aurelionita4734 8 месяцев назад

    Pcb, ionization electrode

  • @ИгорьЯкунин-ъ3з
    @ИгорьЯкунин-ъ3з 8 месяцев назад

    Мне не помогло

  • @gerikuper6473
    @gerikuper6473 9 месяцев назад

    You silver problem or is still there and you need to fix the pcb part.

  • @trinjopj
    @trinjopj 10 месяцев назад

    I found solution here: ruclips.net/video/HxFCYD90YP8/видео.html&ab_channel=NikitaGushin

  • @rolandgal2877
    @rolandgal2877 10 месяцев назад

    This is total nonsense. Replacing the capacitor does not solve any problem, something else causes the error. These are manufacturing defective panels regardless of whether the PCB is 1 or 3 years old.

    • @luk5827
      @luk5827 4 месяца назад

      The problems are the SMD resistors , transistors , diodes and the Relay . Please look the thread in Elektroda forum with Genus One gas boiler : " Ariston Genus One System: Addressing Gas Boiler Errors 501,504,309,5p3 After Replacing Parts "

  • @istvanfejes7815
    @istvanfejes7815 10 месяцев назад

    I am currently struggling with an Ariston Genus One 5P3 error. I replaced the gas valve, which was clearly full of dirt and the filter was torn. But the 5P3 error is still present with the new gas valve.

  • @mihaicornea5922
    @mihaicornea5922 10 месяцев назад

    Hello! after all, you still put the Bumper Little black piece, or not?

  • @ryszardidkowiak8625
    @ryszardidkowiak8625 10 месяцев назад

    Witam, mam od miesiąca ten sam problem. Pytanie czy po likwidacji "zderzaka" błąd 5P3 powrócił po jakimś czasie?

    • @michalaron4784
      @michalaron4784 10 месяцев назад

      Since removing bumper no flame cuts

  • @octaviansorescu7427
    @octaviansorescu7427 10 месяцев назад

    Ok! Thank you very much!❤

  • @octaviansorescu7427
    @octaviansorescu7427 10 месяцев назад

    Did you put it back or not? Thank you!

    • @michalaron4784
      @michalaron4784 10 месяцев назад

      I didn't

    • @giuseppeavellina508
      @giuseppeavellina508 10 месяцев назад

      Grazie di vero cuore se per favore mi puoi dire se il paraurti lo devo mettere si oppure no grazie di vero cuore

  • @octaviansorescu7427
    @octaviansorescu7427 10 месяцев назад

    What do you call a bumper? That little black plastic piece in the piston head? It's like you chose not to wear it!!!! Or did I not understand correctly? I saw that the piston that regulates the pressure had a small plastic piece. In the end I understood that you didn't put it on the assembly anymore.

    • @michalaron4784
      @michalaron4784 10 месяцев назад

      Bumper=little black piece, it is kind of rubber material, it's supposed to avoid clicking noise when valve opening, therefore "bumper", I think due aging rubber get shrinking and do not hold in place-in piston.

  • @octaviansorescu7427
    @octaviansorescu7427 10 месяцев назад

    Hello! If you didn't put that small black plastic protection, didn't it give error 5P3? Was that little piece blocking the piston? Or don't let the piston open all the way?

    • @michalaron4784
      @michalaron4784 10 месяцев назад

      Because of loose little bumper, piston can't fully open gas valve, too much air, lack of gas in combustion chamber cause flame cuts

  • @serr78
    @serr78 11 месяцев назад

    👍

  • @magaliosn
    @magaliosn 11 месяцев назад

    Ευχαριστώ πολύ με βοηθήσατε πολύ να λύσω το πρόβλημα μου !!!

  • @GertBorremans
    @GertBorremans 11 месяцев назад

    I have a gas burner Chaffoteaux Alexia Green 29 of Ariston. There is an error code 303. How can I resoled the problem. Can you help me? Thanks.

    • @michalaron4784
      @michalaron4784 11 месяцев назад

      There is different mainboard, so i have not exact solution for you...sorry

  • @jamespoland3078
    @jamespoland3078 11 месяцев назад

    Do you know the fix for fault 503 flame sensed with gas valve closed

    • @kamen0s22
      @kamen0s22 5 месяцев назад

      hello James, have you found solution for error 503 Flame with gas valve closed ? Thanks

  • @PaulAntonescu
    @PaulAntonescu 11 месяцев назад

    did it ever cut flames again w/o the bumper?

  • @mynameis1244
    @mynameis1244 11 месяцев назад

    Had the same problem. Zero support from Ariston. What I did and my advice to You is - consider buying something different than Ariston....

  • @slahbenchaabane9243
    @slahbenchaabane9243 11 месяцев назад

    It works!! Thanks a lot for this video

  • @ИгорьЯкунин-ъ3з
    @ИгорьЯкунин-ъ3з 11 месяцев назад

    Спасибо Мвйклу, хотел уже новую плату заказывать. Все работает.

  • @SergioIFC
    @SergioIFC 11 месяцев назад

    1nf 3kv or 2kv? Thanks

  • @cihan9118
    @cihan9118 Год назад

    Thanks Snr. Aron. I had the same problem. No flame and flame interrupt. By your guidance i have solved the problem. Replaced the cap with 1nf 300v plastic package from backside of the selenoid connector. Pin 1 and 3. All seems good. Also renewed some darkened solders because of heat. Thank you very much and greetings from Turkiye.

  • @antreasg4044
    @antreasg4044 Год назад

    Hello Michal, what is the value of overheated resistor? Thank you

  • @AndrejRebikov
    @AndrejRebikov Год назад

    Thanks! That works!

  • @SergeiBash
    @SergeiBash Год назад

    For 5P3 in my case i just restarted it a couple of times and it started working again...

  • @Елена-ц7ц7т
    @Елена-ц7ц7т Год назад

    Что за немое кино?

  • @savueugen3982
    @savueugen3982 Год назад

    Pe gpl tot da eroarea 5p3

    • @gerikuper6473
      @gerikuper6473 10 месяцев назад

      Electrovalva dacă ai sau presiune gas

  • @ana-mariachiper6223
    @ana-mariachiper6223 Год назад

    What value does the capacitor have?

    • @michalaron4784
      @michalaron4784 Год назад

      ii video is 22nF, but it should be 1nF capacitor

  • @savueugen3982
    @savueugen3982 Год назад

    Am făcut la fel și A-mi apare erore releu gaz

    • @saimon953
      @saimon953 4 месяца назад

      Salut, ai reușit/rezolvat până la urmă problema la tine? Aceasi eroare îmi da și mie! Eroare releu gaz.

  • @alanimaz4192
    @alanimaz4192 Год назад

    Hi, I'm speaking from Argentina, I have the same problem. I already tried and verified everything, gas pressures, clean the entire gas system, check grounding, measured voltages, everything is ok. I changed the capacitor for one of 1nf as indicated in the video and I still have the same problem. The boiler turns on and after a while it throws error 501, reset, turns on again and after a while error 501, recipes again and does not turn on, up to 6 recipes, turns on again. throws relay error also sometimes. what else could i try?

  • @rayjones3473
    @rayjones3473 Год назад

    Just fitted this boiler and 5p6 code straight from the box

  • @federfed9860
    @federfed9860 Год назад

    Hola saludos yo tengo problemas con la misma placa me marca error 304 Y mi dicen que tengo que cambiar micro

  • @Enginiklimlendirme59
    @Enginiklimlendirme59 Год назад

    but in video seems like pin 1 and 2 shorted

  • @JM-sh4no
    @JM-sh4no Год назад

    Hello! I have the same problem and I don't know if yours could be fixed because maybe it was brought from America itself, but in my case nobody gives me the solution because I brought it from Spain to Ecuador, you could tell me if that has nothing to do with it and you could give me hope?

  • @jakubkepski4276
    @jakubkepski4276 Год назад

    Hello! I have conduction between 1 and 3 pin. Is my Valve trash?

    • @michalaron4784
      @michalaron4784 Год назад

      no, there is selenoid = wire with resistance cca 20 ohm /60ohm

  • @bigt5699
    @bigt5699 Год назад

    What is E 52 and how to fix

    • @hakrihe
      @hakrihe 8 месяцев назад

      Google says: E52 indicates either a bad motor or motor controller. several articles say to access the motor and remove the power plug, and the ohms across pins 1 and 2, 1 and 3, 2 and 3 should be 4 to 6 ohms, and pins 4 and 5 should be between 105 and 130.

  • @PANCAKEPAP1
    @PANCAKEPAP1 Год назад

    Whats the solution for error 504?

  • @iandavidson99
    @iandavidson99 Год назад

    Do you know which one modulates the outlet pressure? Is it the motor collected across 1 and 3, or 2 and 4 ?

  • @lucretianita6904
    @lucretianita6904 Год назад

    Nu merge încălzirea la calorifere, numai apa caldă merge

    • @luk5827
      @luk5827 4 месяца назад

      Cauta pe net forumul Elektroda : " Ariston Genus One System: Addressing Gas Boiler Errors 501,504,309,5p3 After Replacing Parts "