  • #Calibrator : fixed value, matrix is same as sample, available in liquid or lyophilized form
    #Standard : fixed value, matrix is not same as sample
    #Control : value in range, matrix is same as sample, available in liquid or lyophilized form
    #calibration curve
    #Quality control

Комментарии • 20

  • @zohmingthangi3884
    @zohmingthangi3884 8 дней назад

    Best explanation so far

  • @Xarakreshi
    @Xarakreshi 2 года назад +4

    Nice way to make students understand......keep it up....👍🏻

  • @worldfootballz3416
    @worldfootballz3416 Месяц назад

    Last example is awesome ❤

  • @fraabebe1431
    @fraabebe1431 8 дней назад

    😊😊😊

  • @miriamt7094
    @miriamt7094 2 года назад +1

    Thank you,
    Question: What are parameters as mentioned at 4:00?

  • @kevindasilva4595
    @kevindasilva4595 2 года назад +1

    Thank you for the explanation !!

  • @emadissawy7811
    @emadissawy7811 2 года назад +1

    please
    I hope you can explain the difference between standard and calibration
    And can you also explain what a blank is?
    But I hope you write the explanation in an easy and simple way
    Sorry to bother you

    • @SarojJungKunwar
      @SarojJungKunwar  2 года назад +1

      Blank is actually used to set the zero absorbance in the machine.
      For blank we can use Distill water or Reagent blank i.e reagent without sample
      For a particular test, reagent blank will be best to use.
      Thank You

    • @SitiSarah-n8b
      @SitiSarah-n8b 2 месяца назад

      @@SarojJungKunwar What does it means if the blank failed?

  • @Thanhdien6896
    @Thanhdien6896 Год назад

    Thank you very muchhhhh🎉🎉🎉

  • @yannickkamta2719
    @yannickkamta2719 Год назад

    Thanks

  • @pradeepkumardas4048
    @pradeepkumardas4048 3 года назад +1

    very nice dai

  • @malikzadafaisal6358
    @malikzadafaisal6358 2 года назад

    beautiful explanation

  • @user-ds4rm6tp9r
    @user-ds4rm6tp9r 2 года назад

    Does the result using calibrator is more accurate than standard because it has the same matrix as the sample?
    For example why in urea test (berthelot) calibrator is used instead of standard ?
    It would be awesome if you help me with my question
    Thank you for your useful video

    • @SarojJungKunwar
      @SarojJungKunwar  2 года назад +4

      It is better to use calibrator instead of standard, but at the same time test such as urea which has wide reference value in which small fluctuation in result doesn't matter can use any of either std or calibrator

    • @user-ds4rm6tp9r
      @user-ds4rm6tp9r 2 года назад

      @@SarojJungKunwar thank you for answering ! It meant a lot!
      I have another question about the urea test (berthelot)
      Why in kits of the test there are 2 different reagents and we have to mix it to make a working reagent? Why they don't make a prepared working reagent? Does NADH reaction with something and makes the reagent unusable?
      I'd be so happy if you could help me with this
      I'm sorry if I'm bothering you with my questions

    • @SarojJungKunwar
      @SarojJungKunwar  2 года назад +5

      @@user-ds4rm6tp9r It is to increase the stability of reagent, they should be stored isolated