Traffic Light Control System Program INPUTS: 2 Digital Inputs OUTPUTS: 9 Digital Outputs APPLICATION: In This Application There are two Digital Inputs working as a START Push Button and STOP Push Button to START and STOP the Control System. 8 Outputs are there, working as GREEN Light and RED Light for Each side of four roads. 1 Output is working as Yellow Light when System Traffic Light Control System is in STOP Mode. CONDITIONS: SYSTEM START: By Pressing START Button GREEN Light for First side should be ON for 10 seconds, after 10 seconds GREEN Light for First side will be OFF. As First GREEN goes OFF Second GREEN will be ON for 10 seconds, after 10 seconds second GREEN will be OFF. As Second GREEN goes OFF Third GREEN will be ON for 10 seconds, after 10 seconds third GREEN will be OFF and same for GREEN four. When GREEN of any side is ON, rest of the sides should be in RED ON Condition. SYSTEM STOP: By Pressing STOP Button all the GREEN and RED Lights Should be turn OFF and Yellow Light Should be turn ON continue.
1. Draw ladder logic for traffic light signal of two lanes. Pressing start push button red light of lane 1 is energized for 15 sec and green light of lane 2 is energized for 10 sec. when green light goes off then yellow light of lane 2 is on for 5sec. vise versa. Sir above question ke liye draw kijiye ladder logic pls
Last me reset krane ke Liye Input Me T4:2/DN bit lena padega aur output me 3 reset parallel me lagega aur use hum T4:0,T4:1 aur T4:2 addressing denge. Tab ja kar program shi hoga.....
Hi, Nice video, Thanks a lot. I have a doubt - how timer going to reset, is there any control wiring to the timer for reset, we have seen that some push buttons are used for reset, Kindly can you explain.
Thankyou so much for the comment dear. 1.) Agar apko pure process ko off karna hn to fir hume binary (Memory bit) ko off karna hoga uske liye hum ek NC use karenge in first rung. 2. Dear second wala question clear nhi ho paa rha hn apka.
Sorry for the late reply dear. Lec no 34:-ruclips.net/video/rrwDtH_Y4rk/видео.html Lec no 35:-ruclips.net/video/fo5LFruWTNM/видео.html Lec no 36 :-ruclips.net/video/GX5O78zNuIw/видео.html
Station Make a list of all Inputs and Outputs A printing station labels the object, as they travel along an assembly line. When object arrives on the line, sensor will detect an object and stop the assembly line. Then 'clamp' output will ON for 10 seconds to held object during the operation. For initial 6 seconds a 'spray' output will apply the thermoset ink. In the last 4 seconds a 'heat' output will dry the ink. (10 Marks) Then after object is released and allows to continue along the line. Stop the assembly line after finishing 5 objects for refilling thermoset ink. Safety consideration - Design an Emergency stop for undesired events. any body knows programming of this task?? if anybody knows please help me
Super bro , This is the best video ( traffic light 🚦) on RUclips & your explanation is so awesome 👍❤.
Thanks a lot for the feedback dear.
💐💐💐
besbri se intazar tha
Great explain sir .. muze dikkat aati thi isme ... Apne use dur Kiya .... Thanks 🙏🏻
Thank-you so much for the feedback dear.
💐💐💐
Aap ka video jabardast hai sir!
Thx you so much❤❤❤❤❤❤❤
Well explained
Thanks for the feedback dear.
💐💐💐
Very nice
I am getting all programs easily
Thank you so much for the feedback dear.
💐💐💐
Good job
Thank you sir video was too good and informative 👍🏻👍🏻
Traffic Light Control System Program
INPUTS: 2 Digital Inputs
OUTPUTS: 9 Digital Outputs
APPLICATION:
In This Application There are two Digital Inputs working as a START Push
Button and STOP Push Button to START and STOP the Control System. 8
Outputs are there, working as GREEN Light and RED Light for Each side of
four roads. 1 Output is working as Yellow Light when System Traffic Light
Control System is in STOP Mode.
CONDITIONS:
SYSTEM START:
By Pressing START Button GREEN Light for First side should be ON for 10
seconds, after 10 seconds GREEN Light for First side will be OFF.
As First GREEN goes OFF Second GREEN will be ON for 10 seconds, after 10
seconds second GREEN will be OFF.
As Second GREEN goes OFF Third GREEN will be ON for 10 seconds, after 10
seconds third GREEN will be OFF and same for GREEN four.
When GREEN of any side is ON, rest of the sides should be in RED ON
Condition.
SYSTEM STOP:
By Pressing STOP Button all the GREEN and RED Lights Should be turn OFF
and Yellow Light Should be turn ON continue.
This is the theory part of above vedio.
Very good. Thanks 🙏🙏🙏🙏
Thanku so much for the feedback dear.
💐💐💐
1. Draw ladder logic for traffic light signal of two lanes. Pressing start push button red light of lane 1 is energized for 15 sec and green light of lane 2 is energized for 10 sec. when green light goes off then yellow light of lane 2 is on for 5sec. vise versa.
Sir above question ke liye draw kijiye ladder logic pls
You are the best
Thanks for the valuable feedback dear.
💐💐💐
Sir aapka video bahut acha laga ,, sir automation related question or ans ka video banavo na
Thankyou so much for the feedback dear.
💐💐💐
Last me reset krane ke Liye Input Me T4:2/DN bit lena padega aur output me 3 reset parallel me lagega aur use hum T4:0,T4:1 aur T4:2 addressing denge.
Tab ja kar program shi hoga.....
زبردست
Nice Exlanation sir, Sir i have one confusion jo aapne fisrt timer ke series me memory bit liya he na Wow NC rakhna he kya , final hone ke bad program
Thanks for the feedback dear.
Dear will once check then i will inform you.
💐💐💐
Digram me to samjh aa gaya . Software se kaise karna hai wo sikhna hai
Sir can we use off delay timer instead so no of rungs will be reduced and we can use just the DN bit ...what do u say about this ?
Excellent
How to get all videos at one place
Dear,
Please check my playlist learning PLC.
💐💐💐
Hi, Nice video, Thanks a lot. I have a doubt - how timer going to reset, is there any control wiring to the timer for reset, we have seen that some push buttons are used for reset, Kindly can you explain.
Sir ji aap video banate rahi sir plz 🙏🙏🙏🙏🙏🙏🙏 plc k upar!
Thank-you so much for the feedback dear.
💐💐💐
Thanxx sir....
Timer me TT and ACC me kya difference hai?
Dear in my nxt video I will cover this concept again.
💐💐💐
Hi sir, what kind of questions can interviewr ask on this topic?
Sir
counter se same logic n be skta kya instead of timer
Yes dear
You can try it in many other ways too.
💐💐💐
Sir aap software kon sa use karte hai plc programming ke liye
Plc kon see company ki hai
Dear,
Mai Allen Bradley and omron PLC prefer karta hn for my videos
Omron software name:- Sysmac Studio
Allen Bradley:- RSLogic 5000
sir plez make video on different truth tables
Thanks for the feedback dear.
Please suggest any question for that you want video.
💐💐💐
Sir Timer ON Delay liya hai ki
Off delay
Dear On delay timer ka use kiya hn.
Sir ,4 side traffic light ki example dijie
Last timer ka donebit ka NC, first timer pr v de skte h
Sir explain ladder . PUSH BUTTON 1 TURN OP1 ON .PUSH BUTTON OP2 ON .BUT OP1 ON THAT TIME OP2 OFF .AND OP2 ON OP1 OFF (VISE VERSA)
Dear thanks for the question.
Ok soon I will make this PLC logic.
💐💐💐
Thx sir
Sir, interview m programming se related jo v questions puchhe jaate h wo v aap krwao..🙏So that, students ko help mil jaye..🙏🙏🙏🙏🙏
Thank-you so much for the comment dear.
PLC MCQ questions for interview:-ruclips.net/video/XK5XtWfmlUg/видео.html
Thankyou.
💐💐💐
Thankyou so much for the comment dear.
1.) Agar apko pure process ko off karna hn to fir hume binary (Memory bit) ko off karna hoga uske liye hum ek NC use karenge in first rung.
2. Dear second wala question clear nhi ho paa rha hn apka.
Apki jo bhi queries hn plzz comment me
I will be very happy to clear ur doubts.
But sir next cycle start karne ke liye again & agin X0 input high karna padega
sir can you please explain about the logic circuit diagram for lift control system upto 3rd floor considering a suitable time for operation
Ok dear I will make the video on it.
💐💐💐
@@industrialsolutions8138 sir please make early…. I really want it please help sir and thank you sir for replying
sir i am getting assignment in my college but i am not able to do it ... sir please upload it early please
@@industrialsolutions8138 sir you are not replying
Sir is program ko computer m banye kaise ye bhi btaye,timer ko tt aur dn kis trh computer m laye
Dear ye program Allen Bradley PLC mai design kiya hua hn.
Aur Allen Bradley PLC software mai ye sabhi option hote hn.
👍
@@industrialsolutions8138 agr possible ho ske to Mitsubishi ka bna kr bhi daal dijiye
Ok dear
And soon I will start PLC programming on Mitsubishi PLC.
Sir please upload lecture 34 35 36 🙏🙏
How to operate Repeat this cycle ? Kaise sequentially operate kare?
Can u give the explanation in detail for this ladder lgic diagram in English.
Sir ake sathe country and res challu ho jayaga
Reverse counting meter ka logic batayo , Timer downside kesey chalata hai
Which switch we shoud draw ON in exam?
Sir ye plc konsi h AB , Siemens ya koi or plz kyo ki sabki ladder logic alag hoti h
Allen Bradley PLC.
Kaun sa timer hh sir
Dear
T-on timer ka use kiya hn programming mai.
💐💐💐
in the reset bit it is only T4:0 or T4:0/DN or T4:0/TT
Why we are not holding timer in this qn... Plz reply sir
Allen Bradley plc ki programming hai yeh..!
Yes dear.
💐💐💐
Sir two way traffic light plc programming ka video bana dijiye 🙏
Ok dear,
Soon I will make the video on it.
💐💐💐
Sir channel par 4th unit upload kardo SCADA
Thanks for the comment dear.
Ok I will work on it.
💐💐💐
Can you program for off delay timer
Thanks for the feedback dear.
Soon I will make the video for that.
💐💐💐
Sir can be add end at last of this question
hye
kya app pedrsian walk ka program bna skte hai f
Sir how to create calculator programming in ladder logic plz tell us
Thanks for the comment dear.
Soon I will make a video on cal PLC program.
💐💐💐
How to do for 4 way pls explain
Shar bhulat tarn sighnal parogharamingh
Sir isme apne TON timer liye h kya TOFF timer
Ton time dear.
💐💐💐
Please shere the plc ladder diagram for load shedding of transformer . Today only
Tresser ka progarming kaise karte hai
Hi sir good evening.
Sir, please upload lecture 34, 35, 36 I can't found can you give that lecture Link thanks sir🙏🙏
Sorry for the late reply dear.
Lec no 34:-ruclips.net/video/rrwDtH_Y4rk/видео.html
Lec no 35:-ruclips.net/video/fo5LFruWTNM/видео.html
Lec no 36 :-ruclips.net/video/GX5O78zNuIw/видео.html
Baki sab sahi Kiya Maine lekin reset nahi ho raha
Sir sppu university mark nahi deti yese solve karne par
I'm not getting the language 😢
Learn Hindi
Idhr puri engineering getting nhi ho rhi and tu langauge me ro rha😂
@@ss_2939It is easier to learn from someone else
Go to hell
I'm also 😢
sir reset kese kre ga
Station
Make
a
list of all
Inputs and
Outputs
A printing station labels the object, as they travel along an assembly line. When object arrives on the line, sensor will detect an object and stop the assembly line.
Then 'clamp' output will ON for 10 seconds to held object during the operation.
For initial 6 seconds a 'spray' output will apply the thermoset ink. In the last 4 seconds a 'heat' output will dry the ink.
(10 Marks)
Then after object is released and allows to continue along the line. Stop the assembly line after finishing 5 objects for refilling thermoset ink.
Safety consideration - Design an Emergency stop for undesired events.
any body knows programming of this task??
if anybody knows
please help me
Neya video kab Tak ayega
Thanks for the comment dear.
Any Topic for new video
@@industrialsolutions8138 laptop or PC me kese ladder logic programing karenge?
Ok I will work and make a video on it.
Dear uske liye hum NC use karenge first rung me.
All part lecture link send me
Reset kaise hoga pura batao adhura gyan ky
Ye to chala hi nhi sahi se
wrong connection
english please
Ok dear,
I will make the videos in english for you.
💐💐💐
Translate into English
Bakwas same program Mitsubishi me banaya work galt hota hai
Sɪʀ ʜᴜᴍ ᴛɪᴍᴇʀ ᴋᴏ ᴄʜᴏʀ ᴋᴀʏ ᴍᴇᴍᴏʀʏ ᴋᴏ ᴠ ʀsᴛ ᴋᴀʀ sᴀᴋ ᴛᴀʏ ʜᴀɪ ɴᴀ
Thankyou sir
Thank you so much dear.
💐💐💐
thankyou sir
Welcome dear.
💐💐💐