DSE Programming in Urdu/Hindi Chapter -1 Video Link: ruclips.net/video/2CciDviyP-w/видео.html DSE Programming in Urdu/Hindi Chapter -2 Video Link: ruclips.net/video/mHiIu1KgCK0/видео.html DSE Programming in Urdu/Hindi Chapter -3 video Link: ruclips.net/video/Ef5wSAoIeLU/видео.html DSE Programming in Urdu/Hindi Chapter -4 ruclips.net/video/h1BU37gpFPY/видео.html
This video is very helpful for me. We will want to see these type videos on controllers EMCP, DIE NE, POWER WIZard, TURBURG CONTROLer etc. Thank you very much sir this is very informative video. JazakAllah
Your tutorials are excellent. I have a 1998 Kohler 35 kw natural gas industrial generator with a DEC (Decision Maker) 340 controller. It is set up for single phase 220v. Mice damaged the controller wiring. This controller is obsolete as well and used tested units are very expensive. This system has a speed controller that throttles the carburetor to maintain 1800 rpm. I have an ASCO series 300 automatic transfer switch. Which replacement controller would you recommend as a replacement that would provide the necessary system protection s and would work with the analog sensors of the present system. The ability to monitor it remotely would be a bonus.
Thank you for making the video it has been a big help. However I do have two questions. There is no preheat relay, unless I wire an additional relay to the fuel relay, Second question is does voltage build up in the generator stop crank when starting? As my engine does not have a magnetic pick up or CAN.
Hi there thanks for the video, if i want to start it only at night when the power is of and if the power comes on it must stop, where do i put in a timer so that it don't start in the day?
Dse 8610MKII synchronizing controller full training Part 1 video Link: ruclips.net/video/7SSpPzUazdA/видео.html Part 2 video link: ruclips.net/video/-NJ8BpXdrjs/видео.html Part 3 video Link: ruclips.net/video/ly_3RiZNg2w/видео.html DSE 8610 Part 4 VIDEO LINK configuration: ruclips.net/video/eNnEgmlzYuI/видео.html Practical training 8610 video Link: ruclips.net/video/zwLP5X9gGhc/видео.html
very nice explained . is the cranking continuing with the fuel solenoid valve open as shown in the diagram (both NC contacts) or any other control ckt is involved to disconnect cranking with the gen picked up speed ? pl reply.
Hi friend,,, Only one thing I want to ask. The terminals nr 6 and 7 they give positive (+) signal at the same time whish is not acceptable for ATS logical operation. So how to configure for normal operation of ATS in order to not send for example the close signal at same time to source A and B .
I have some questions sir what purpose of con 2 in main supply is it for sensing voltage fluctuations or if 3phse volt or current not properly is it activate the generator automatically? And if starter relay or fuel pump relay is open circuit or high resistance can we use multimeter to measure voltage drop test same as DC circuit (24volts). If mechanical pump what purpose fuel relay?
हमारे पास DSE 4522-01 हमारा DG LINE रहने पर भी AUTO मे करने पर START हो जाता है,, हमारा MAINE PANNEL मे भी AMF लगा है जो COMMAND तो देता है मगर मैन FAILURE का केबल कहा जोड़े DCE 4522-01 मे pls guide कीजिये कैसे होगा
Hi sir. Hope you can help me please. My problem is that I have a Diesel Generator "SmartGen" Digital controlled, Manual and Automatic but I want it to become fully automatic like it will automatically start if Main Supply from Utility is brownout and Stop the Generator if Main Supply is back. Please help me
And mechanical operated fuel pump how it is automatically stop the generator. I know automatically on is energising the starter relay and relay wil de energize after start it's continuely work by mechanical fuel pump than what about stopping how it's stop is it cut fuel system?
He'llo sir plz make a proper video mechanical engine and electronic engine with practical visualization.... So it is easy to understand what is the difference between these two types of engines...
Deep Sea Electronics videos: ruclips.net/p/PL6yN6XwyzoyEAZZjfI_slFZyaZNaSHIRm
whats about TJ509-T , the start remote,.. and stop remote
DSE Programming in Urdu/Hindi Chapter -1
Video Link: ruclips.net/video/2CciDviyP-w/видео.html
DSE Programming in Urdu/Hindi Chapter -2
Video Link: ruclips.net/video/mHiIu1KgCK0/видео.html
DSE Programming in Urdu/Hindi Chapter -3
video Link: ruclips.net/video/Ef5wSAoIeLU/видео.html
DSE Programming in Urdu/Hindi Chapter -4
ruclips.net/video/h1BU37gpFPY/видео.html
People will appreciate your effort including me. Thanks!
Ur welcome
This video is very helpful for me. We will want to see these type videos on controllers EMCP, DIE NE, POWER WIZard, TURBURG CONTROLer etc. Thank you very much sir this is very informative video. JazakAllah
EMCP and Power Wizard is more simple, the Caterpillar ones 😁
Thank you so much it helps a lot❤❤❤
Nice job sir, I apreciate it. Thanks from Brazil 🇧🇷👍
Ur welcome Franck
Good❤
Very nicely explained thank you
Ur welcome
Mind blowing sir thanks
Welcome
Very nice
Your tutorials are excellent. I have a 1998 Kohler 35 kw natural gas industrial generator with a DEC (Decision Maker) 340 controller. It is set up for single phase 220v. Mice damaged the controller wiring. This controller is obsolete as well and used tested units are very expensive. This system has a speed controller that throttles the carburetor to maintain 1800 rpm. I have an ASCO series 300 automatic transfer switch. Which replacement controller would you recommend as a replacement that would provide the necessary system protection s and would work with the analog sensors of the present system. The ability to monitor it remotely would be a bonus.
Thank you for making the video it has been a big help. However I do have two questions. There is no preheat relay, unless I wire an additional relay to the fuel relay, Second question is does voltage build up in the generator stop crank when starting? As my engine does not have a magnetic pick up or CAN.
Thank you walekumassala
Hi there thanks for the video, if i want to start it only at night when the power is of and if the power comes on it must stop, where do i put in a timer so that it don't start in the day?
sir with regards the pin # 18, 19 20 can i connect the MPU or exciter. please advise
Thank you,please show and explain dse 8610 mkii wiring diagram completly.
Dse 8610MKII synchronizing controller full training
Part 1 video Link:
ruclips.net/video/7SSpPzUazdA/видео.html
Part 2 video link:
ruclips.net/video/-NJ8BpXdrjs/видео.html
Part 3 video Link:
ruclips.net/video/ly_3RiZNg2w/видео.html
DSE 8610 Part 4 VIDEO LINK configuration:
ruclips.net/video/eNnEgmlzYuI/видео.html
Practical training 8610 video Link:
ruclips.net/video/zwLP5X9gGhc/видео.html
very nice explained . is the cranking continuing with the fuel solenoid valve open as shown in the diagram (both NC contacts) or any other control ckt is involved to disconnect cranking with the gen picked up speed ? pl reply.
Thanks for Sharing and two questions:
What does GBR stands for?
Can't we synchronize The Three Phases instead of ATS?
Hi. Very interesting video. Is it possible to synchronise 2 or more DG with this type of panel?
Hi friend,,, Only one thing I want to ask. The terminals nr 6 and 7 they give positive (+) signal at the same time whish is not acceptable for ATS logical operation. So how to configure for normal operation of ATS in order to not send for example the close signal at same time to source A and B .
U need to correct ur wiring logic in ats panel make proper interlock and correct relay connections
I have some questions sir what purpose of con 2 in main supply is it for sensing voltage fluctuations or if 3phse volt or current not properly is it activate the generator automatically? And if starter relay or fuel pump relay is open circuit or high resistance can we use multimeter to measure voltage drop test same as DC circuit (24volts). If mechanical pump what purpose fuel relay?
I explain the function of mains supply in video you can watch again
Thank you.how about speed control circuit?
❤
😍
Please how do you take off 3 phase sensing of generators and also how do you connect the ats remote start signal wire to the control circuit?
Plz watch other videos and you will know all the answers of your questions
What's the use of magnetic pickup
How do you wire up/connect the preheat/glow plug?
dear i need know what are the voltage coming out from the controller for oil pressure and others also
हमारे पास DSE 4522-01 हमारा DG LINE रहने पर भी AUTO मे करने पर START हो जाता है,, हमारा MAINE PANNEL मे भी AMF लगा है जो COMMAND तो देता है मगर मैन FAILURE का केबल कहा जोड़े DCE 4522-01 मे pls guide कीजिये कैसे होगा
Hi
Can you run an ats with a 4610 ?
No
How can we reconfigure the dse7320 the generator voltage is 440 vac?
Hi sir. Hope you can help me please. My problem is that I have a Diesel Generator "SmartGen" Digital controlled, Manual and Automatic but I want it to become fully automatic like it will automatically start if Main Supply from Utility is brownout and Stop the Generator if Main Supply is back. Please help me
Join membership to one on one solution via WhatsApp
Buenas tardes, cómo hago para programar las inpust, manual en el módulo controlador
Sr I Wan wiring diagram of dg
How to start DG with other side fixng push buttons
dear sir, can you please provide me the complete wiring diagram of a MDEC engine control system with 4520 MK2 AMF engine generator control system.
Where is the battry changing point when generator on standby mode. How batrry charging
does anyone know what is AR and GFR in controller ?
And mechanical operated fuel pump how it is automatically stop the generator. I know automatically on is energising the starter relay and relay wil de energize after start it's continuely work by mechanical fuel pump than what about stopping how it's stop is it cut fuel system?
Via solenoid every pump have fuel solenoid
Sir,where should we connect charging alternator terminal D+
Pls reply
He'llo sir plz make a proper video mechanical engine and electronic engine with practical visualization.... So it is easy to understand what is the difference between these two types of engines...
Sure I'll try to make a video about that in the future.
🤔 to enter editor mode
Inshallah wo bhe bata dain gay koi away dou module samnay
always seems like no matter what language is being used. when they put a wire diagram down we can understand the person.
Bhi 7320 madol ki mokmal video and Kon Kon sa alarm at hai
Bhai ge urdu mn btaen ta k smjh ay kise ko ye kam krny wLa mA pas ni ho ga under matric hi hon gy zyada tr
Muzamil Bai any job for electrical genrater pleas tell me
Inshallah
Hi..
Sir plz this video PDF
Hi
.
Xie xie
bhi urdo man
ruclips.net/video/NyOvgzZo7Qc/видео.html
ruclips.net/video/chcZnpb6McM/видео.html
Dear Rashid Bhai urdu video k leye link open karain 😍
❤
Bhai ge urdu mn btaen ta k smjh ay kise ko ye kam krny wLa mA pas ni ho ga under matric hi hon gy zyada tr
ruclips.net/video/NyOvgzZo7Qc/видео.html
ruclips.net/video/chcZnpb6McM/видео.html
Dear Awais Bhai urdu video k leye link open karain