This video is about single phase submersible motor starter working in details.
This video is having more details of following main topics,
1)Starter Input & Output Connections
2)Starter working
3)Fault Finding & Servicing
4)Maintenance Tips
Price Details:
Single Phase Stsrter Upto 2HP=2500 INR
Digital DOL Starter upto 5 HP motor capacity=12000 INR
Digital DOL Starter upto 7.5 HP motor capacity=13000 INR
GSM Mobile Controller Price=8500 INR
GSM Mobile Control Digital DOL Starter upto 5 HP motor capacity=16000 INR
GSM Mobile Control Digital DOL Starter upto 7.5 HP motor capacity=17000 INR
(Courier or Parcel Charges Extra)
(Based on quantity & material availability price will vary)
எங்களது பொருட்களின் விற்பனை விலை விபரம் தெரிந்து கொள்ள கீழே உள்ள வாட்ஸ் ஆப் லிங்கை கிளிக் செய்யவும்...
What's App Products Catalogue Link with Price Details:
wa.me/c/919655...
Shop Address:
JJ Tech Solution,
Opposite SPA Weighing Scale Building,
Karur Main Road,
Palayam-624620,
Dindigul District,
Tamil Nadu/India.
Mobile/Whatsapp: +91 9655622352
(Contact us on Working Hours by Monday to Saturday 10.00AM to 6.00PM Only)
வேலை நாள்: திங்கள் - சனி, காலை 10.00 - மாலை 6.00 (வேலை நேரத்தில் மட்டும் ஃபோன் அல்லது வாட்ஸ்ஆப் மெசேஜ் செய்யவும்)
(Sunday Holiday - ஞாயிறு விடுமுறை)
(Shop will be closed on all Sundays & Government Holidays)
Order, Payment & Shipping Mode:
Click above what's app product catalogue link and select & add the products which you want to buy with your required quantity and send the order cart to us and also send your full address with pincode to us to calculate shipping charges.
We will calculate total material cost with shipping charges to your delivery location and message you the total cost of your order including shipping charges.
After making payment for your order, please send the payment receipt screenshot to us to our what's app number.
We will dispatch your order material to your address within maximum 2 working days and we will send your order shipping online tracking details by what's app message to you to track and receive your order materials.
Note:
Prepaid payment & material delivery by Indian Speed POST, courier service, lorry or bus parcel transport Service to all over India.
"Cash On Delivery" not available (NO COD). (Please don't ask for COD).
Shipping charges will be added extra based on the product weight and customer delivery address.
Bank Account Details for Payment:
Google Pay Number: 9655622352
Account Name: JJ Tech Solution
and
Name: J.Edwin Jayaraj
Bank Name: ICICI Bank
ACC No- 218401501956.
IFSC Code- ICIC0006072.
ICICI Bank , Karur Main Branch,
Karur - Tamil Nadu - India.
UPI ID: jedwinjayaraj@icici
CONTENT DISCLAIMER:
"Village Tech Tree" channel videos are only for knowledge and educational purposes. Our videos will be useful for service technicians only. For beginners or hobby peoples our videos will give basic outline idea only. So this RUclips channel will not be responsible for any cause of accidents of faults due to improper knowledge & handling of the products shown in these channel videos. So please be aware and get knowledge of the products before its experimental use.
There is no copyright contents are used in this channel videos. Please contact channel broadcaster before take any legal action.
அருமையான விளக்கம்
நன்றி நற்பவி
Clean and neatly explained
Thank you so much
நல்ல விளக்கம் சார் வாழ்த்துகள்..
Good explanation ,super.one issue 500' depth,1phase 2 hp submersal .starter box heating issue.i opened and checked the condencer,it was over heated.what to do.my starte is also same like this in the video.loose connection in the starter is corrected .again heating when closed. So iuse to open the cover to disipate the heat.pls tell me a remady
சூப்பர் 👌👌👌👌👌👌👌👌👌👌👌👌👌👌👌👌 வீடியோ
Nice தமிழ் Vedio super விளக்கம்
நன்றி
Useful tips and thank you
Thank You
நல்ல தெளிவான விளக்கம் அருமை நன்றி நண்பரே அது போலவே அதிக விலையுள்ள கம்பெனி control'benel. மீடியம் விலை control penel இதற்கான பதிவிடவும் நன்றி
Very useful information thankyou sir
Thank You Brother
Super good.....
அருமை அருமை ......
Thank you brother
Ammeter 10 la eruku sir motor podama normal ah erukum pothu. Prlm ethum erukumo
2 hp single phase motor enna ampere edukkum bro
12 to 13A....
6A per HP
Contactor connection konjam explain pannunga
வாழ்த்துக்கள்
Thank you power wiring diagram vedio sir
Good give more videos about starter . Valga tamilan.
Kandippa Panren Brother
Accidently Input phase nutral mathi conection kudtha motorku problem varuma bro ?
bro mottor oda RYB wire ra cut pannama kandu pidikka mudiyuma bro
Single phase motor 1.5hp ஆழ்துளை கிணற்றில் எத்தனை அடி வரை தண்ணீர் எடுக்கும்
Nice explanation, apdiyae wiring connections explain panna nalla irukum
Kandippa Wiring Explanation Video Pannalam Brother...
@@VillageTechTree mm
motor on pannuna ammeter la 15 kammikkuthu water varala ethu enna problem ah erukkum ethu varykkum ammeter 12 kamikkum water varum
ஆசிரியர் பாடம் நடத்துவார் அதே போல உள்ளது நன்றி அண்ணா சிங்கிள் phase மோட்டார் போர்வெல் கண்டன்சர் பற்றி ஒரு பதிவு இடுங்கள் பல்வேறு சமயங்களில் தண்ணீர் வருவது இல்லை மோட்டார் பிடித்து விடுகின்றது அதை சரி செய்ய எவ்வாறு மற்ற கண்டன்சர் களை மாற்றிப் பயன்படுத்துவது என்று பதிவு செய்யுங்கள் நன்றி அண்ணா வாழ்க வளமுடன்
தங்களின் வாழ்த்துக்களுக்கும், பதிவுக்கும் மிக்க நன்றி... Capacitor testing and adding pathi இன்னொரு வீடியோல சொல்றேன்.
Bro edtha starter ra automatic starter ra matha mudiyuma
Good information
Thank You
good video- i did not understand language but understood the theme. Anyway do try to give English sub titles so more viewers can watch
Sure brother... i will do it in future brother
@@VillageTechTree
Bro...
Oru help
Panel board la power supply pass aaguthu nu theriyala
ஒரு நீர் மொட்டர்ல ரெண்டு வீட்டுக்கு connection கொடுக்கணும் ஆனா ரெண்டு வீட்டுக்கு தனி தனி ஸ்விட்ச் வைகணும் ஒரே starter ku ரெண்டு ஸ்விட்ச் வைக்கணும் தனி தனி மீட்டர் ல ரெண்டு ஸ்விட்ச் வைக்கணும் connection எப்படி
Hi bro submersible motor rccb moolama kudutha trip aguthu.ana directa mainla kudutha motor run aguthu...please replay..why
power supply wiring la leakage irukkum... check panni parunga
Thank u bro.. nice explain... எங்கள் வீட்டில் 1 phase 3hp borewell ... On செய்தவுடன் மோட்டர் ரன் ஆகாமல் கேபில் சூடாகிறது... இதற்கு தீர்வு
Load amps Evlo Poguthu?
@@VillageTechTree 18 amps
Push button அழுத்தி பிடிக்கனுமா... நாங்கள் பிரஸ் செய்தவுடன் ரிலீஸ் செய்து விடுவோம்...
@@user-ud4or4zs3d 3 Second pidikkanum. Apparama Release Pannunga
@@VillageTechTree some time 28 and 22 and 20 amps eduththu bro
Bro starting switch starter capacitor burn ayuduche bro enna problem erukum sollunga brother please
Bro sup motor eppadi reverse la oti check panurathu please reply bro..
To interchange any two phase like R Y B
Yes brother.. Just change connection of R & Y phase output supply to motor
Brother, your explanation is really good. I appreciate your wonderful video.
I have 1hp CRI pump, bore is upto 200ft, recently i am getting sound like (Tak Tak) when i switch green button and it goes like off or reset.
But this is not happening all the time and after switch on motor runs without issue. Sometime no sound at all while starting it.
One thing i notice amps goes upto 12.5 or 13 but goes down in less than a second to 6.0 or 5.8 and motor runs. What is the reason for that sound.
This is due to low voltage or Main supply contact problem. Thank you for your feedback.
@@VillageTechTree Thanks for your reply. CRI service person came and checked and told nothing seems to be looking as issue. But he cleaned area burned little then now it's not occuring. But not sure what fix done.
Supper
Very nice brother. My house pump start take 15ams water not come, reviews connection take 5 sms, pump problem or. starter, please tell me.
May be Capacitor problem
Hi bro new switch change same model bro plz tell me bro very important
Nice explanation anna
Thank You Gokul Anna...
Good work super
Thank you
Bro capacitor multimeter vachi check pannalama
Panna Mudiyathu Brother. Capacitance Testing Meter than Use pannanum
Moter start batten press Panna stard agala bro ena pannanu
ஸ்டார்ட்டர் ஆன் செய்தாள் நிற்கவில்லை, காண்ட்ராக்டர் ஆண் செய்தால் ஆன் ஆகிறது, என்ன பிரச்சனை இருக்கும், சொல்லுங்க சார்
Wiring connection yeppadi pannanum nu sollamaleye video ve mudichitteengale bro....
Main Input and output connection only brother
Bro starter la mcb on pannitu voltmeter check panna...needle raise agalam supply varathamaaari iruku...start switch press pannalum start agala..what is the problem?
Low Voltage
Anna 3pes motor kanakrin
Sir stop swicth ade type switchly start panna agada
Bro 3hp 1phase starter A meter burn aagiduchu Atha mathunale ok aagiduma illa Vera ethum problem irukuma bro
Meter ah change panna pothum... Wire burn aagi iruntha athayum change pannidunga
how many times press start panaum sollunga please 🙏
3 Sec
Hii...sir..enga veetla voltage eponalum 200la kattuthu...motor on pnna amps 15mela kattuthu voltage same level la kattuthu ..water 5min dha varuthu...athuvum romba low va varuthu..enna problem
Ethana HP Motor?
Very useful details.... super sir 150 v supply mother running no ...Enna pannanum sollunga sir..unga number
Servo Stabilizer than use pannanum brother... Athu 19000 to 22000 varum
Indicator light veetu power fuse pudingina kooda erinjittae iruku brother. Enna reason?
Phase and Neutral rendayum of Panni cut Panni Check Pannunga
Anna epdi transformer power supply cut panrathu check pannuvatharkku
Athula oru lever Irukkum, Athu Rotate Panni open panna Transformer ku Vara Input Supply Cut aagidum. But proper Insulation Hand gloves Illama panna koodathu
Bro single phase auto starter wiring explain panduga plz
Kandippa Panren brother. Please wait
அன்புள்ளம் கொண்ட சகோதரருக்கு திருநங்கை சகோதரியின் முதல் வணக்கம் 1Hpநீர் மூழ்கி மோட்டார் பேனல் போர்டில் உர் என்ற சத்தம் வருகிறது அது என்ன கோளாறு என்பதற்கு தயவு செய்து விவரம் தெரிவிக்கவும் லாக்டவுன் ஆகையால் நேற்று எலக்ட்ரிசியனை சரி செய்ய சொன்னேன் அவர் பிசியாக வரமுடியாத சூழ்நிலை நன்றி வணக்கம்
ஆம்ப் 22 மேலே வருகிறது மோட்டார் ரன்னிங் ஆனால் 0 ஆமப் க்கு மேல் வரகூடாது என்கின்றனர் எனன பிரச்சினை
My ampere metre not working. Is it so motor is not getting started?
Maybe one of the reason brother
Start pannum bothu control box la noise loud ah create aguthu enna problem irukkum
Contact Problem
Analog voltmeter problem ayuduchu, digital voltmeter direct aa voltmeter line la fit panalama bro.
Pannalam
Wiring Connection solunga bro
மோட்டார் ஸ்டார்ட் ஆகி என்ன ஆகுது ஆனா ஆம்பு மீட்டர் வேலை செய்யல இதுக்கு காரணம் என்ன ஆம் மீட்டர் ரிப்பேரா
Sir...... Starting capacitor output kidaikkalana motor on agatha
ON Aagumbothe problem varum... Continue ah run aagathu
Bro.. Starter la single phase light indication off aayitu...enna problem nu solla mudiyumaa??
Indicator Fault. Indicator change panni parunga
Starting capacitor burn agiruthu so athu yathanala problem varuthunu sollunga bro
Continues usage or voltage fluctuation problem la burn aagum
Bore வாட்டர் வருகிறது sir but shock அடிக்குது தண்ணீரில் என்ன செய்வது
Use circuit diagram for explaination..
Ok next time
Sir how to pannal two controller
bro automatic level contactor setting so long bro
Kandippa Feature video la Solren
sir nanga bore pottu thanni varla eram man vanthuchu 360 adi potom water next day20 adila erunthu submoter matinom thanni konjsm vanthuchu aprom varla ena problem pls ans pannunga
Water Source romba Kammiya irukku... Athuthan problem
@@VillageTechTree thank u
stop button not working sir how to solve
Hi anna enakku intha stater முழு வரைபடம் வேண்டும்
Connection lam pirichitu 1st la erunthu connection potu katunga...
Try Panren Brother
வணக்கம் சார். கொஞ்ச நாட்களாக மோட்டார் 270 v இருந்தால் மட்டுமே தண்ணீர் வந்தது. தற்போது 270 v இருந்தாலுமே தண்ணீர் வரவில்லை. அதோடு சிறிது நாட்களாக தண்ணீர் கலங்கலாக வந்தது. என்ன காரணமாக இருக்கலாம்???
Bore water level keela poi irukkalam
Start switch work aagala na Enna panrathu sir sikiram sollunga plz😭
Stop switch & No Volt Coil nalla irukka nu check pannunga..
Sir motor pressure. Reduce. Agudhu adjust pannalum improvement illa. How to check. Capacitor
Capacitance Testing Meter la test Pannalam
Ams mtr not reduce 0 what problem sir
Meter problem
Starter shorting problem with certain no problem problem 2hp only
Bro motor switch on pannavea main power break LA vuluthuduthu enna problem ma irrukkum solluga
First motor winding continuity check pannunga, next capacitors la leakage od burst irukka nu check pannunga...
Bro oru doubt 1.5hp motor 10amps startingla eduthuchu aana ippo 13amps vara edukkuthu water speed koranchuruchu athavathu 10min la tank nerambum ippo 15min aaguthu .capacitor problem na amps kooda edukkuma.athoda oru capacitor thaan inga fix pannirukkanga.please explain
Athu capictor problem illa motor bush problem
Impeller or Pump shaft Bush Problem Irukkalam
Thank u
Over load nu kaatudhu motor panel la adha eppadi sari pannanu sir plzzz
Digital Controller Ah?
சார்.இந்த.சுச்சுக்குபதில்.வேற.மாடல்.சுச்சுமாத்தலாமா.சார்
மாற்றலாம்
Motor ON panathum ammeter la load above 10 katuthu like 15,20 udane OFF panitu ON panna correct ah irku then konja time aprm trip off ayidthu yen.?
Starting Capacitor Problem or Starting Capacitor Switch Problem Irukkalam. Motor pump la friction abnormal Ah Irukkalam. Step by Step Ah Check Pannunga
Starter totally burn achu sir..6 hours running.so burned.all are changing parts in starter.but motor not working sir.ena problem ah irukum sir?
Low voltage and Overload Current problem
Enga submersible motor run agumpothu (A ) ammeter reading 12.5 Amp kamikkithu. Is it danger.? Then what can I do..?
Motor HP?
Sir,,, today oru moto fault atten panna poi irudhen adhoda connection totally different ahh irudhuchu,,, off push botten la neutral control aagi condector coil ku derect ahh pogi irudhuchu, on push botten la phase control aagi irudhuchu and,, on botten kum off botten kum series connect illa sir,,, andha circuit wiring paathu fulla confuse aaiten,,, therija connection yum marathu poiruchu sir,,, plz help me sir, oru clear connection with diagram solli kudunga sir 🙏🙏🙏 plz....
Feature Videos la full Wiring Explain panren
Ammeter 15la nikkuthu sir moter work aagala sir ena panrathu
Starting and Running Capacitor nalla irukka nu check panunga...Input AC supply 210V to 230V irukka nu check pannunga
Eppo starting la 13 or 14 amps iruku sir 1 hours aparam 12 amps varuthu appo thanni problem ma or water illa nu problem ma sir plz reply tha text sir
12Amps load la Water Output Irukka? Illa Dry Ah run Aagutha?
On button on press pana home all light off aguthu
Bro
I have more doubt
Sir ok my 7 hp motor but not there capacitor sir please explain
Maximum Upto 3HP range only available in single phase operation... After that 5HP, 6HP, 7.5HPare in three phase only
Why 2 capacitor using for running? Explain ji
because (36uf+36uf=72uf or 50uf+36uf=86uf la standard ah market la capacitor kidaikkurathu illa... Based on motor HP rating running capacitor value change aagum
@@VillageTechTree
Thanks
Starter box fulla body aaguthu ena problem...??
Wiring la Insulation problem
அண்ணா எங்க வீட்டு 1.5HP மோட்டார் போட்டு 10 நிமிடம் தண்ணீர் ஊற்றி விட்டு பின் ஆம்ஸ் அதிகமாகி தண்ணீர் நின்று விடுகிறது
என்ன பிரச்சினை என்று சொல்லுங்கள்
Bore water dry aagi Pump struck aaguthu brother. Bore la water level epdi Irukku?
Bore water level epadi check panrathu bro motor veliya eduthu pakkanum
Same problem in my house
Starter Amos power 11 mela increase anale water stop aguthu 10 min tha water varuthu then amps power increase agi water stop aguthu edhu starter problem ah ella Electrical power issue va kindly tell me
Water ellana amps power below agumnu solranga athu correct da bro
kumar yes Correct than... water Output illana Load Amps konjam Reduce aaguma... Maximum 2 amps Reduce Aagum
Bro starter ON panna amps high yaa irruku, aparam trip agiduthu
OverLoad Problem ah Irukkalam. Pump rotation Problem ah Irukkalam
Stater on panum pothu full house lights off aguthu bro
Over load or Low Voltage Problem
2hp motor la அடிக்கடி panal ஃபோர்டு mcb போகுது yen prichanierukum Anna
Ethana amps MCB use panreenga?
@@VillageTechTree
25amps Anna
@@kumaresanajith9081 Normal load la Unga motor Enna amps consumption pannuthu?
@@VillageTechTree amps 10 Anna
Volt 210 anna
Ippo vara single phase panel board 3 capacitors varthu bro ...
Starting ku one Capacitor and Running ku 2 Capacitor. So total ah 3 Capacitors
Sir எங்க motor ஐ off பண்ணும்போது bore well போட்ட இடத்தில் இருந்து vibration sound வருகிறது சிலசமயம் sound கம்மியாகவும் சிலசமயம் அதிகமாகவும் வருகிறது. அது எதனால் sir
bore la water return porathunala than sound varuthu... Non Return Valve Use pannunga
Thank you sir
Connection for motor reverse running
Feature video la panren
1.5 Hp motorna 3 condenser irukuma anna....
Yes brother... Starting Capacitor-1 Nos and Running Capacitor-2 Nos
Enga veetula single capacitor thaan irukku bro
@@chelliahselvam Appo athu Capacitor Running Motor. Athula Single Capacitor than Irukkum
Stater on ஆன் ஆகமாட்டேங்குது சொல்லுங்கே
ON / OFF switch and wiring link ah check pannunga