Very good presentation Syedraja bro.Many things i could understand well because you made easy to understand. Thank you.Enhancement of Audio volume will help a lot when many of us do not prefer to use Headphone.
This channel is pure gold, thank you very much. If may I, I would like to add that before executing any step described in this tutorial, double check the PLC model you're using to match the High-speed counter and the inputs it uses. Also, when it comes to using a two-phase encoder (which is my case), a bit (MXXXX) must be used to START the doble counter, instead the phisical input X. For further information you can check out the chapter 2, page 28 on the manual . Thank you!.
Hi, very good information, i have a dude about high speed counter, the HC202, how can reset the input without digital input? Im using the instruction DCNT
Hi there, I do not understand your question exactly. If you mean how can reset the counter, naturally you can use the reset instruction (for example see the time 10:00)
Sorry I do not have any practical experience in interfacing Delta PLC with a Stepper motor or an encoder right now BUT I am planning to create a related course in that subject in the future
Hi there, maybe the counter names of your PLC are different from mine. Also, pay attention that counters can be used in different methods (1 phase input, 1 Phase 2 input, ...) with different inputs (X0, X1,...). therefore read the counter section of your PLC user manual carefully
Very good presentation Syedraja bro.Many things i could understand well because you made easy to understand. Thank you.Enhancement of Audio volume will help a lot when many of us do not prefer to use Headphone.
Wow, thanks for your comment, I am glad you liked the video!
Thanks for compliments, if you have any suggestion to present the videos even better, I would be happy to hear!
This channel is pure gold, thank you very much.
If may I, I would like to add that before executing any step described in this tutorial, double check the PLC model you're using to match the High-speed counter and the inputs it uses. Also, when it comes to using a two-phase encoder (which is my case), a bit (MXXXX) must be used to START the doble counter, instead the phisical input X. For further information you can check out the chapter 2, page 28 on the manual .
Thank you!.
Thanks for your comment. Please, if you have any question about the lesson, be more specific and let me know what exactly the question is.
Hi, very good information, i have a dude about high speed counter, the HC202, how can reset the input without digital input? Im using the instruction DCNT
Hi there, I do not understand your question exactly. If you mean how can reset the counter, naturally you can use the reset instruction (for example see the time 10:00)
Hi, how was the result? did it work?
Hi, yes I tried reset the high speed counter with reset instruction but, don't working, finally i can reset with the instructions DRST
Thanks, I need your help, how can I synchronize a stepper motor with an encoder? Can you guide me a bit?
Sorry I do not have any practical experience in interfacing Delta PLC with a Stepper motor or an encoder right now BUT I am planning to create a related course in that subject in the future
thanks a lot
You are most welcome
tahank you good teycher
You welcome!
@@plcgoods Sir, we are waiting for the continuation, we are waiting for your trainings about full position mm with hsc
thanks bro, but i can't do same you C243,please help me
Hi there, maybe the counter names of your PLC are different from mine. Also, pay attention that counters can be used in different methods (1 phase input, 1 Phase 2 input, ...) with different inputs (X0, X1,...). therefore read the counter section of your PLC user manual carefully
Can I use another external input such as X20 instead to count C243 as highspeed counter ?