(Gpm × delta T) 24 आपको हमेसा gpm और delta T जो लेना है वो evaporator side का लेते है. आपको gpm कितना design है ये आपको पता होना chahiye. Oske बाद nikl लो asani se
AHU: It Is A MECHANICAL ASSEMBLY OF FANS,COILS,FILTERS AND HUMIDIFIER OR DEHUMIDIFIER INSTRUMENTS INCLUDED IN A CABINET HAS AN INLETS & OUTLETS. Treated Fresh Air Units (TFA) are also known as Fresh Air Handling Units (FAHU). Unlike Air Handling Units that are used to recirculate the air in an enclosed space, TFAs cater to large, fresh airflow and recovery needs by treating outdoor air using filters and condition it some degree using a cooling system.
Air scrubber एक cooler की तरह काम karta hai ये air ka Flow जो hota hai वो सीधा होता है( straight) जिसमें हम axiel fan use करते है जिसमें हम air का direction change nh होता है जैसे celling fan, cooler etc. Air washer same है but ये बड़ी Unit के लिए काम कराता है. जिसमें हम blower use करते जिसमें हम Centrifugal fan लगा होता है जिसे heavy pressure के लिए हम use krte hai और इसमे ham air का direction change कर सकते है.
Air scrubber same exhaust ki तरह काम krta hai फर्क़ इतना होता है कि air scrubber के नीचे पानी भरा होता है. और एक पानी का Pump laga hota hai circulation के लिए. इस pump me Nozzles lga होता जो पानी को spray karta hai और इसके बाहर से एक जाली लगी होती है जो इसके होके कुछ scrubber आता है तो वो पानी मे घुल जाता हों और एयर filter होकर fr blower supply karta hai
Good
Thank u so much Wasim Bhai
Thanks sir
Very good expalanation
Thanks for liking
Thanks
Thanks you sir
Carry on
1 number content he bro carry on
Very nyc explain waseem bhai very good information ❤❤❤❤
Thanks bhai
Sir 400cfm me 1ton hota ha=
1ton =3.16kw hota ha
Sir supervisor par ek question paper bana dijiye.
Tnx you sir ❤❤❤❤❤❤❤
Wasim Bhai 1ton=3.516 1ton=400cfm 1ton=12000 hota hi
very nice. and I want to ask you bro how to find out the capacity of a chiller unit if the Ton is not given in its name plate?
(Gpm × delta T) 24
आपको हमेसा gpm और delta T जो लेना है वो evaporator side का लेते है. आपको gpm कितना design है ये आपको पता होना chahiye. Oske बाद nikl लो asani se
Hello sir... Sir sare questions ka answer sir bs aise hi btaiye jitna Clint ko intrview m hm btaege.
इससे jyda nh पूछता बस 1 से 2alg हो सकता है
वसीम भाई 1 ton में 3.516 k.w होता है और 4.7 hp होता है क्या ये सही है
Yes
Right
Kon AC interview punch hai
Yes
Right
Many questions covers pls tell IKW, COP, of chiller and cooling tower
Chiller COP Calculation - Divide the cooling capacity of the chiller in kW by the power input of the chiller in kW.
Cooling tower efficiency check my cooling tower interview questions and
Bahut dhire aawaz h apka
Sir 3 way ,2 way valve pe ek vedio uplod kar dijiye please
Hai app playlist me check kijye
Ahu TFA fcu air washer scrubber mai difference btaye pls for interview purpose
AHU: It Is A MECHANICAL ASSEMBLY OF FANS,COILS,FILTERS AND HUMIDIFIER OR DEHUMIDIFIER INSTRUMENTS INCLUDED IN A CABINET HAS AN INLETS & OUTLETS.
Treated Fresh Air Units (TFA) are also known as Fresh Air Handling Units (FAHU). Unlike Air Handling Units that are used to recirculate the air in an enclosed space, TFAs cater to large, fresh airflow and recovery needs by treating outdoor air using filters and condition it some degree using a cooling system.
Air scrubber एक cooler की तरह काम karta hai ये air ka Flow जो hota hai वो सीधा होता है( straight) जिसमें हम axiel fan use करते है जिसमें हम air का direction change nh होता है जैसे celling fan, cooler etc.
Air washer same है but ये बड़ी Unit के लिए काम कराता है. जिसमें हम blower use करते जिसमें हम Centrifugal fan लगा होता है जिसे heavy pressure के लिए हम use krte hai और इसमे ham air का direction change कर सकते है.
Air scrubber same exhaust ki तरह काम krta hai फर्क़ इतना होता है कि air scrubber के नीचे पानी भरा होता है. और एक पानी का Pump laga hota hai circulation के लिए. इस pump me Nozzles lga होता जो पानी को spray karta hai और इसके बाहर से एक जाली लगी होती है जो इसके होके कुछ scrubber आता है तो वो पानी मे घुल जाता हों और एयर filter होकर fr blower supply karta hai
Sir humlogo par deyan rakhiye
Jarur q nh
R22 ka discharge pressure 120 to 150 hota h sir
250 to 300 psig
Standing pressure shyd ap ny dekha ho
Microphone q nhi use karten hajn
sare vedio me sound kam h.
CHILLER KA ( I K W) KESHE NIKAL TE HE
Kia niklna hai
@@wasimtechnical8904 technical compressor ka I K W NEKALNA HE
How much kw input you gave and how much kw output received from the chiller. It is called ikw. Lower the ration. Higher the porformenc .........cop
Challer operator or Chiller technician interview mein farq hota hai yah eik eik jisa interview hota hai?
एक ही होता है but chiller operator को थोड़ा chiller देखना padta hai
Aproch kaise nikalte h bataiye mujhr sir
Video play list me dekho
Phle thik se ek baar me bolna sikho
Assalam walekum aap apna phone number dijiye na