Window AC Gas Charging Refilling | Gas Leak Check | Refilling at Home | Procedure | AC Not Cooling
HTML-код
- Опубликовано: 18 окт 2024
- Window AC Gas Charging Refilling, Gas Leak check, ac gas refilling at home, ac gas charging procedure, window ac gas, ac gas filling, window ac ki gas kaise check kare, ac mein gas kitni honi chahiye, ac mein gas charging, gas charging in ac, window ac not cooling problem hindi, window ac not working, window ac not blowing cold air, ac compressor running but not cooling
******Buy VOLTAS, HITACHI, DAIKIN AC from Amazon at Best Rates******
******VOLTAS WINDOW AC's******
Voltas 1.5 Ton 3 Star Window AC (Copper, 183 DZA, White)
amzn.to/2UzW0dP
Voltas 1 Ton 3 Star Window AC (123 Lyi/123 LZF, White)
amzn.to/2UENEBG
Voltas 1.5 Ton 5 Star Window AC (Copper,185 DZA/185 DZA R32, White)
amzn.to/2D02Y1L
Voltas 0.75 Ton, 2 Star Window AC (Copper, 102 LZF, White)
amzn.to/2IrpF3s
*******HITACHI WINDOW AC's*******
Hitachi 1.5 Ton 3 Star Window AC (RAW318KUD Kaze Plus, White)
amzn.to/2KR2mlw
Hitachi 1.5 Ton 5 Star Window AC (RAW518KUD Kaze Plus, White)
amzn.to/2IoyU4t
Hitachi 1 Ton 5 Star Window AC (RAW511KUD Kaze Plus, White)
amzn.to/2XnyCOq
Hitachi 1.5 Ton 5 Star Window AC (RAV518HUD Summer QC, White)
amzn.to/2Iribxi
*******VOLTAS SPLIT AC's*******
Voltas 1.5 Ton 3 Star Split AC (Copper, 183 JZJ/183 JZJ5, White)
amzn.to/2uQxWoM
Voltas 1.5 Ton 3 Star Split AC (Copper, 183DZZ, White)
amzn.to/2TVz4Bu
Voltas 1.5 Ton 3 Star Split AC (185JY/183JZJ1, White)
amzn.to/2KdYNFP
Voltas 1 Ton 3 Star Split AC (Copper, 123 CZA, White)
amzn.to/2I01uIY
******VOLTAS SPLIT INVERTER AC's******
Voltas 1.5 Ton 3 Star Inverter Split AC (Copper, 183V DZU/183 VDZU2, White)
amzn.to/2I49lWe
Voltas 1.5 Ton 4 Star Inverter Split AC (Copper, 184V SZS, White)
amzn.to/2uMSyOB
Voltas 1.5 Ton 5 Star Inverter Split AC (Copper, SAC_185V_JZJ, White)
amzn.to/2Vsxzwi
Voltas 1.5 Ton 5 Star Inverter split AC (Copper, 185VCrown, White)
amzn.to/2VYMdeL
Voltas 1.4 Ton 3 Star Inverter Split AC (Copper, 173V JZJ (R32), White)
amzn.to/2uR79IJ
Voltas 1 Ton 3 Star Inverter Split AC (Copper, 123V DZU/123 VDZU2, White)
amzn.to/2uRUndg
*******HITACHI SPLIT AC's*******
Hitachi 1.5 Ton 3 Star Split AC (Copper,RIDAA 3100f RSC318HBD White)
amzn.to/2KIoYVc
*******HITACHI INVERTER SPLIT AC's*******
Hitachi 1.5 Ton 3 Star Inverter Split AC (Copper, RSD317HCEA, White)
amzn.to/2XlGtMs
Hitachi 1.5 Ton 3 Star Inverter Split AC (Copper,MERAI 3100x RSD318HBEA White)
amzn.to/2PeSK2F
Hitachi 1.0 Ton 3 Star Inverter Split AC (Copper,MERAI 3100s RSF312HBEA White)
amzn.to/2XmPB3G
Hitachi 1.5 Ton 5 Star Inverter Split AC (Copper,KASHIKOI 5100x RSB518HBEA White)
amzn.to/2PjFYQu
******LLYOD Window AC's******
Lloyd 1.5 Ton 5 Star Window AC (Copper, LW19B52EW, White)
amzn.to/2I0YSdV
Lloyd 1.5 Ton 3 Star Window AC (Copper, LW19B32EW, White)
amzn.to/2KrLKRl
******DAIKIN, CARRIER Split AC's******
Daikin 1.5 Ton 5 Star Inverter Split AC (Copper, FTKF50TV, White)
amzn.to/2YUwOOE
Daikin 1.5 Ton 4 Star Inverter Split AC (Copper, FTKP50TV, White)
amzn.to/2UzLRho
Carrier 1.5 Ton 5 Star Inverter Split AC (Copper, CAI18EK5R39F0+CI185R3CH90, White)
amzn.to/2UAqOep
Carrier 1.5 Ton 3 Star Split AC (Copper, CAS18EK3R39F0+CF183R3AC90, White)
amzn.to/2YVFtAc
***LG, WHIRLPOOL, MITASHI SPLIT AC's***
LG 1.5 Ton 5 Star Inverter Split AC (Copper, KS-Q18YNZA, White)
amzn.to/2uLWlf8
Whirlpool 1.5 Ton 3 Star Inverter Split AC (Copper, 1.5T MagiCool 3S COPR Inverter, White)
amzn.to/2KcWGC4
Whirlpool 1.5 Ton 5 Star Inverter Split AC (Copper, MAGICOOL PRO 5S COPR INV, White)
amzn.to/2uQSq0B
****V Guard Stabilizers****
V-Guard VG 400 Voltage Stabilizer Range 170V - 270V
amzn.to/2HP9qg8
V-Guard VG400 AE20 Stabilizer for 1.5 Ton AC (Working Range: 160V-280V)
amzn.to/2FLLtnQ
V-Guard ID4 Ace 5540 Stabilizer for Inverter AC Up to 1.5 Ton (Working Range: 140V - 280V)
amzn.to/2Ztb6ld
V-Guard VWR 400 Voltage Stabilizer for Ac Upto 1.5 Ton (130V-300V)
amzn.to/2CWMTdt
V-Guard ID4 Ace 5540 Stabilizer for Inverter AC Up to 1.5 Ton (Working Range: 140V - 280V)
amzn.to/2UsuYW1
V-Guard VND 400 Plus Voltage Stabilizer for Ac Upto 1.5 Ton, 150V - 285V
amzn.to/2HQwuLm
V-Guard VNS 400 Digital Voltage Stabilizer
amzn.to/2HPxBv2
V-Guard AD4 Volta 3030 Stabilizer for 1.5 Ton AC (Working Range: 150V-290V
amzn.to/2OBgJbU
V-Guard VG500 Stabilizer for 2 Ton AC (Working Range: 170V-270V)
amzn.to/2HPai4o
Monitor 5-KVA Wall Mountable Voltage Stabilizer For 2.0 Ton AC (100% Copper) With 5-Year Warranty 170-270 V
amzn.to/2I0sI1u
#windowacservice #acservice #windowac
After a long wait, AC gas charging video is here. Like Comment share and subscribe 😍👍
Sir my ac start but after 4min ac automatic off, and no cooling, what problems??
Leakage repairing cost
Thank you sir Aap Ki Jaise video koi nahin banata hai pahli bar Dekha aur aapko fan Ho Gaya mai
Very informative video . Thanks for such a wonderful video . I generally do not comment on you tube videos but this video was just amazing . I literally do not know about AC. Bcoz am also facing the same problem in my window AC . But now am confident about everything. Thanks once again and keep making videos.
Glad that my video helped you
badhiya.mera ac issue kar raha tha,ab confusion duur ho gaya,atleast ghar par check karlunga.thanks for your video sir
Bahut sunder video hai best knowledge
I really like your videos, just have a question I bought my ac last year in 21 march and just a week back got first ac service which was free as per warranty. Can you guide me do I need to call technician to check cooling and gas of my window ac as I only used once in last summer. And if not required right now so when should I check gas and cooling, after how much time of using my AC? It's daiken 1.5 window ac, Plz guide me on priority as today is last day of warranty 21 march.
Excellent vedio thsnks
Detailed, Excellent
Glad you liked it!
Mast video pura samaj mai aagaya
Nice information
Excellent... detailed information..
Sari gas nikalne k bad jb new gas dali jati hai to vacuum krna jaruri hai ya esy hi gas bhar skte hai plz rply
Vacuum hamesha karna padta hai
Supar video sir
Thank you
Thank you sir for update, Sir My hitachi window Ac 2 pipes evaporator are forming ice, which melts after 10 minutea, this happened after service from some local mechanic, Sir kindly advise, now should I get solution from Hitachi customer care/ service centre or any local expeienced mechanic/electrician in this field can do the job
Gas is low, ice should melt within 2 minutes
Good Details video sir 👍
Very nice information
Very nice information bro..
Aap bhi meri tarah bahut badhiya kaam kar rahe ho bhai dhanyvad 🌷🙏
sir window ac me cooling coil pe full ice jamti hai. reason leak ya ac chowk.
Video hai is topic par
@@TapanGupta sir link send kar do.
Self vecum kr sakte hai
Bro, 1.5 ton carrier window ac hai. Front coils pe ice aa rahi hai. Cooling sirf saamne khade hone pe feel hoti hai thodi si. Technician ne bina check kiye bola ke leakage hai. Leakage thik karenge, coils ki coating karenge aur gas refill karenge. 3k ka kharcha bataya hai
Gas leak hai, baki aap technician se bargain kar sakte hai
@@TapanGupta okay bro. Thanks 🙏
Lovely video loved it
Tapan when I start my window ac it works for a while then makes sound like a steam engine like whoosing sound from behind so wht might be the reason
Very nice info sir
Nice video 😊
Sir mera o general window AC hai use service karate hue 1 saal ho gaya hai aur aaj chalu kiya hai toh service karana hoga kya aur gas leak toh nhi ho jaye gi na
5 minute ke liye chalane se koi nuksaan nhi hoga, agar air flow Kam hai to service Kara lijiyega
Sir Split AC gass rifle ka video v banao
Okay
Sir me ne khud clump meter se check Kiya h usme read 5.5 ka ata h and max 6.0 gya h kya gas full h ya nhi? Mere ac ko aprrox 5-6 year hi gye h and abi tak 1 bar bi gas nhi dali isme.1.5T ka ac h Panasonic ka windows ac.
Aage ke coils me ice aa rhi hai ya nhi?? Aur agar aa rhi hai to kitni Der me ice melt ho rhi hai
@@TapanGupta ice aa rahi h and 2-3 min me melt ho rhi h but puri melt nhi ho rhi thodi si ice rhe jati h.jab new liya tha tab 27°C me bi thand lag jati thi ab 22°C pe rheta h ac.
Han to minor leak hai KHI, ice poori Tarah melt honi chahiye, leak check Kar ke fix Karna padega, ya abhi chalayen jab bilkul cooling band ho Jaye tab leak fix aur gas charging Karwa len
sir window ac me r410 ki gas charging ki video jaroor banaye.
Nice video sir
ISS Karigar ki kyaa fees hogi yehi sab hamarey kartey to??
👍👍👍👍👍 excellent work bro
Thank you so much 😀
Helpfull video
Good Detail Video
Sir mere window ac me water nahi nikal rha kya problem ho skti h
Sir gas fresher kitna rakhna rehta h
Excellent
Bhai ji pura kharcha kitna aata h iss process ka ? Humare AC m 3-4 front stick m ice aa rahi hai bs aur mujhe guide kr do kya krna chahiye 🙏 aur kaha se krau ise theek ye bhi btana 🙏
Bhaiya kab tak wait kru apke reply ka mujhe aaj kal m theek krana hai 🙏
Good effort
AC chalane seh bhi pani or ice nei nikala, agar cooling doh heh, doh yeh kya digat/problem heh?
Cooling is there but water is not coming out? So is there any problem with the AC?
IS THERE ANY SOLUTION FOR THIS??
No problem, if cooling is fine everything fine
1 ton bluestar window ac h samne se cooling aa rhi h room cool nhi ho rha h kya problem ho sakta h
Room bada hoga, room seal nhi hoga, Diwal aur chat heat ho rhi hongi, agar samne cooling aa rhi hai aur room cool nhi ho rha to ac mein koi gadbadi nhi hai
Refrigerant Sealed can mein lena safe rehta hai..........Local Cylinder me
in gas contaminated ho sakti hai ya duplicate bhi.......Refrigerant qty ka label har A/c mein hota hai ...Qty measure karke hi dalni chahiya .....and A/c Amps bhi definitely check karn chahiye ...Technician are not so qualified........Keep In mind.
Nice suggestions 👍👍
22 number gas is widely used and is available in big cylinders.
Will it be free of cost if ac is under warranty
Not sure ek janne wale se warranty me bhi paise le liye the, aap confirm Kar lijiye
very nice
Nd which state is he from
Don't know just got servicing, gas refilling done for window AC however seems my room is not cooling enough though the only cooling I am getting while standing infront of AC..feels like my AC has now become cooler..😄 frustrating 😒..any suggestion would be greatly appreciated..
Gas leak Shi se fix nhi Kiya Hoga jis wajah se gas low hoti ja rhi hogi, leak fix Kar ke Shi quantity gas padegi to ye problem nhi aayegi
@@TapanGupta Thnx..brother really appreciate it....very helpful info for me..I will get it fixed asap..
@@_prashantkumar9928 you are welcome, check Karne ke liye Kuch din aur wait kariye, bilkul cooling khatam ya Kam ho jayegi
@@TapanGupta sure brother...Thnx alot
Agar fan mein bhi pressure nahin tab bhi hawaa ka throw poor hota hai
How much they charged you ????? Company wale the ki local mechanic ?????
Private shop aur charges 1500-2000 lete hai iska
Sir mera acha company ka technician " Clamp meter" Par last year gas check karwa rhe tha.. . Jo ki ac ke power cord par attach kiya usne.... Aab mujhe malum nahi ki kya woh bhi sahi tarika hai aur hai toh uss meter par kitni reading honi chahiye agar woh clamp meter se pata chalta hai... Plz bataye Mujhe urgently dobara se bulana hai srrvice ke liye... Agar gas proper hai toh kya woh sahi meter use kar rhe hai aur reading kitni ho... 1.5 T - 5star ... Cooling capacity 5060W
Clamp meter se current Ampere me check Kiya jata hai ki compressor load par aur Bina load par ampere reading kya rehti hai, aap meter ke chakkar me na pade ye dekhen ki apka AC cooling Kar rha hai ya nhi
@@TapanGupta oh iska matlab 60-75 psi jo apne video mein dikhaya woh CLAMP METER se nahi pata chalta..!!!
Abhi 2nd season ki service due hai, AC company se aana hai technician ne, lockdown ki wajah se time lag raha hai... Actually waise toh mein coils par icing check khudh grill open karke check kar leta hu, kyunki 3rd floor par kabhi kabhi aisa lagta hai jaise cooling kam hai isliye socha ki pata chal jaye ki proper gas hai ya kam..!!
60-75 psi pressure meter hota hai
Aur cooling se hi apko gas Ka idea lagega
@@TapanGupta ok sir.. Thanks very good video & informations shared 👍
Very nice dear
Welcome
sir i have question
every year my ac need refilling gas ?
If the leakage is fixed properly then your ac will not refilling for at least 10 years
@@TapanGupta oh thank you sir.
best wishes for next video
What he doesn't tell us leakage isn't always somclear
.it can be in very minute ways which no one wishes or knows to.look into.he only says oil oil all the time
If yu saw oil the. That area if you remember nd around has leakage if you don't remember ..like I have seen any oil..then how does one find
Hi.bro
My ac compressor is working but its not getting proper cooling ..can you plz help me..
Front coils me ice aa rhi hai jab compressor start hota hai Uske thik baad?
@@TapanGupta no ice
@@TapanGupta miniteeakage point ta bhi hotey hongein Kyun last service ke Baad teen chaar Mahiney mein hi jawaab dheerey dheerey khatm hui.skilled technician air chor naa ho tab Kahan jaayein
Sombdy recommended clean with caustic soda nd another chemical dissolved in water (abt 20 ml)..now another sombdy says caustic leakage create Karti hai..hcnluminum pipes dissolve with diissolved caustic soda..but cooling certainly gone
Good
Badiya
Sir my AC fan is moving very slow in. Air filter panel and it is not cooling well please solve my problem .
He doesn't seem.to b an expert thi m he talks to the technician seekh ke.apna vedio banatey hain
HI! my window AC's fan is working at only high speed and not on low and medium? is it the motor? how much does a new motor costs for Voltas 1 ton window AC?
If motor is never repaired then it's PCB problem
@@TapanGupta Thanks!! The technician said the motor needs to be replaced or repaired. It has never been repaired till now. I’ll see what’s to be done. Thanks!
@@TapanGupta PCB?
Yes
Hitachi is probably with aluminium coiling
Sir mere window ac m gas refill karne se pahle uusme refill pipe open karke uuse on kiya jisse compresser ka oil bhar aagya then uusne gas fil kardiya abh wo cooling uutni nahi karta
Thoda oil bahar Aaya ya zada?? Cooling Kam Kar rha hai to usi technician ko bulaiye, gas ya to Kam daali hai, ya leak Shi se nhi check Kiya, leak fix karaiye
@@TapanGupta sir uus time oil jada hi laga tha like 250 ml
@@TapanGupta or sir gas refill kara diya h but oil bhar nikla h too koi problem too nahi h
@@surendarpratapjatol912 thoda oil nikal jaye to koi problem nahi lekin zada nahi nikalna chahiye kyonki compressor ek engine ki tarah hota hai jisme piston hota hai, jisko oil chahiye hota hai
Sir kitne rupees me dalti hai ye gas
1500 se 2500 jaisa aap bargain kar paye
Nice
Price
Sir my ac start but after 4min ac automatic off, and no cooling, what problems??
Compressor off or complete ac off
@@TapanGupta 4min bad ac off
Complete ac off, next electric switch off on, ac firse chalu, fir 3-4 min bad same......
Don't remember seeing oil anywhere.lsst time I washed my self with help of a driver..no trusted technician around.nitroogen nitrogen kehkar dimag kharaab kar detey hain
एयर प्रेशर डालकर जब यह लीकेज चेक करते हैं तो फिंस के बीच में जो पाइप होता है उसका लीकेज कैसे चेक किया जाता है
Us jagah normally leakage nhi hota, Jha leak hoga oil dikh Jayega, aur agar us jagah leak hua BHI to Foam spray se pata chal jayega
ac ka amper se bhi pata lag jata hai gas ka
Gas daalwane ka kharcha ??
1500 apko bargain kar ke fix karna padega
@@TapanGupta mere ac me mechanic n bola h ki 1500 ki gas pdegi no guarantee aur 2500 me with gurantee ..What should I do?😥😥
Hi। मेरा वोल्टास का 1.5 टन का विंडो ac है मैने सर्विस कराई तो cooling करना कम हो गया है। टेक्नीशियन बोलता है कि गैस कम है । मैने आपकी वीडियो देखी और ac का कंप्रेसर on करके देखा तो साइड वाली पाइप में बर्फ जमती है और 1 मिनट में खत्म भी हो जाती है। तो मेरा ac किस कारण से cooling नही कर रहा है। क्या वकईं मेरे ac में गैस कम है। प्लीज बातये मुझे क्या करना चाहिए।
Agar AC ke side wale pipe me turant ice aati hai aur pighal BHI rhi hai tab to aage ke Sare pipes 2-4 minute me chill ho rahe honge??
Aisi situation me cooling to honi chahiye, AC ke back side dekhiye , Garam hawa fek rha hai??
Sb kuchh to theek hai lekin Gas ki praise apko nhi btani thi😝😝
sir filter kyon change nahi kiya
Filter aur capillary har baar gas refill par change nhi hota, mera ac zada Purana nhi tha
Paise kitne lagge ye batao
Mere 1000 lage lekin technician aapse 2000-2500 charge karenge
@@TapanGupta ok as a technician hi puch rha tha apse
@@TapanGupta apke 1000 kyu lage bhai
Hame gus fil karaya hi fir v cool nahi ho raha hai
Jisse gas fill karaya usi ko bula kar dikhaiye, kai reason ho sakte hain, leak shi se nhi check Kiya hoga to gas nikal gai hogi
to dosto kesa lga apko 🤣last mai kya hogya apko jada khusi agi kam acha hogya to
Bhai meri ac ki gas baar baar nikal jaa rahi h
Sirf 1 din m hii
Kitna paisa lgta hai leaked sahu karne me
Technician 1500 se 2500 lete hai leak plus gas refilk
Kya Bhai apka number mil skta h
camera man theeek admi nhi h
Very nice