MS05c. [Siemens S120 #2] SINAMICS S120 Configuration and Commissioning via Startdrive TIA Portal

Поделиться
HTML-код
  • Опубликовано: 14 окт 2024
  • #STARTER #Startdrive #S120
    Before: [S120 #1]. S120+STARTER • MS05b. [Siemens S120 #...
    Next: [S120 #3]. One Button Tuning SINAMICS S120. • MS05d. [Siemens S120 #...
    Siemens Control Playlist: • Siemens Controls
    Motion Control Playlist: • Motion Control
    TIA Portal drive integration with SINAMICS Startdrive
    new.siemens.co...
    SINAMICS Startdrive V17 Download
    support.indust...
    Application example Entry ID: 109743270 Configuring a SINAMICS S120 with StartDrive
    support.indust...
    Which hardware and functions of SINAMICS G130, G150, S120, S150 and SINAMICS MV are supported by SINAMICS Startdrive V15, V15.1, V16 and V17 ID: 109761180
    support.indust...
    ----------------
    MS05a. [Siemens S120 #0]SIMAMICS S120 Motion Control Series Open Speech (S7-1500 + S120)
    • MS05a. [Siemens S120 #...
    MS05b. [Siemens S120 #1] SINAMICS S120 Configuration and Commissioning via STARTER
    • MS05b. [Siemens S120 #...
    MS05c. [Siemens S120 #2] SINAMICS S120 Configuration and Commissioning via StartDrive TIA Portal • MS05c. [Siemens S120 #...
    MS05d. [Siemens S120 #3] One Button Tuning S120 via STARTER and TIA Portal Startdrive
    • MS05d. [Siemens S120 #...
    MS05e. [Siemens S120 #4a] Setup PROFINET Connection Between S7-1500 PLC and S120 Servo Drive
    • MS05e. [Siemens S120 #...
    MS05f. [Siemens S120 #4b] Setup Motion Technology Object (TO) to Control S120 Servo Drive
    • MS05f. [Siemens S120 #...
    MS05g. [Siemens S120 #5] SINAMICS STO Safety Torque and SS1 Safe Stop vis Safety PLC
    • MS05g. [Siemens S120 #...
    MS05h. [Siemens S120 #6] How to Tune the TO Positioning Closed Loop Gain Kv in TIA Portal
    • MS05h. [Siemens S120 #...
    MS05i. [Siemens S120 #7] Use Motion Control Function Blocks to Control S120 Servo Drive
    • MS05i. [Siemens S120 #...
    MS05j. [Siemens S120 #8] S120 Servo Drive - Changing Velocity On the Fly
    • MS05j. [Siemens S120 #...
    MS05k. [Siemens S120 #9] SINAMICS S120 Torque Limitation, Torque Reduction
    • MS05k. [Siemens S120 #...
    MS05l. [Siemens S120 #10] SINAMICS S120 Velocity GearIn
    • MS05l. [Siemens S120 #...

Комментарии • 38

  • @alejandrojulian804
    @alejandrojulian804 Год назад

    So good your tutorial series, i have a question, how i know what kind of memory cp works with the CU 320-2 PN, please help me :)

  • @gelearn2362
    @gelearn2362 2 года назад +1

    Thank you very much for the lesson

  • @damianhl5448
    @damianhl5448 2 года назад +1

    Very nice video. I have one question. The CU320-2 PN can only be used with S7-1500 CPU if i want commission in stardrive (i'm using stardrive v17)?
    If i want connect to a s7-400 i need to commission the sinamics in starter?

    • @vorapobautomation9760
      @vorapobautomation9760 2 года назад

      How can do it in TIA ?

    • @electricalautomation
      @electricalautomation  2 года назад

      If you are using S7-400, you can not use the 'TO'. You can use the position loop in the CU320, then the S7-400 just send position command.

    • @vorapobautomation9760
      @vorapobautomation9760 2 года назад

      Is the CU320 can use in startdrive with S7-400 ?

    • @alejandrojulian804
      @alejandrojulian804 Год назад

      It can works with the S7 1200 PLC too@@electricalautomation

  • @ariancontrol2430
    @ariancontrol2430 Год назад

    hello
    thank you for useful video!
    i have a sinamic cu320 version 2.6.2 with CBE profinet card and i want to have it in TIA portal but there is not such model in TIA hardware catalogue!!
    is it possible to add this model in tia portal ? if yes how?

    • @electricalautomation
      @electricalautomation  Год назад

      I would recommend using Starter software and ' auto config' function, you can view from ruclips.net/video/9odur-A1_lI/видео.html

  • @محمدالسروري-ه4ه
    @محمدالسروري-ه4ه Год назад

    goooood

  • @shahzaib1994
    @shahzaib1994 Год назад

    Hello I am Using 1 CU with 2 Drive of Servo. I am using telegram 1 for Both Drive & Telegram 390 for CU. I am using profibus connection with s7300. With Programming Blocks sfc14 & sfc15. With DB. I have a Problem that only One Drive is Sending & receiving Data. Both CU & Drive 2 Show No Telegram in Interconnection setting. Could you please help me

    • @electricalautomation
      @electricalautomation  Год назад

      Have you set the telegram 1 at the drive side? Why you are using the telegram 1 (the speed control) for S120(a high end servo drive). Aslo your question is far away from this video topic, I would recommend contact Siemens support for your application, my feeling is that you are directing not quite direction for using your control devices.

    • @shahzaib1994
      @shahzaib1994 Год назад

      @@electricalautomationYes I am using Telegram 1 for both 2 Drive. But in My Program I call sfc14 & sfc15 3 Times. 1 for CU, 2 for 2nd Drive, 3 for 3rd Drive but it only read Sfc of Drive One CU & Drive 2 Register not Sending & receiving. is there any Method to Increase Profibus Cycle. I think it is Profibus Cycle Issue.

    • @electricalautomation
      @electricalautomation  Год назад

      @@shahzaib1994 This link should be helpful support.industry.siemens.com/cs/document/8894584/micromaster-4-(mm4)-sinamics-g120-(cu240s-d-dp-dp-f-pn-pn-f)-essentials-for-profibus-and-pkw-mechanism-?dti=0&lc=en-CA

  • @devendrachowdary2333
    @devendrachowdary2333 2 месяца назад

    I am not able to connect the plc S7-1212C with the drive S120 CU310-2 Pn

    • @electricalautomation
      @electricalautomation  2 месяца назад

      S7-1200 (v4.x) can not use 'TO' to control S120. You can use 'GSD' method and EPOS telegram 111 to control S120.

  • @veys9655
    @veys9655 11 месяцев назад

    how to prevent when we stop and start the cpu or cut off the power of control panel to loss home position ? I want that when I set home position once, then I wanna keep it always. it doesn't matter then whether I cut off the power or cpu stop. Can you please help ?

    • @electricalautomation
      @electricalautomation  11 месяцев назад

      Using multiple revolutions absolute encoder for your servo drive.

    • @veys9655
      @veys9655 11 месяцев назад

      @@electricalautomationBut I'm already using absolute encoder ? can't I do it with Control unit?. I mean CU320 in startdrive side ?

  • @derina.maleek9408
    @derina.maleek9408 2 года назад

    You nailed it

  • @bartw4245
    @bartw4245 2 года назад

    very, very helpful:) thx

  • @movies1774
    @movies1774 2 года назад

    Very good Sir

  • @bhagyodayasinghjadhav
    @bhagyodayasinghjadhav 2 года назад

    Very good...

  • @vorapobautomation9760
    @vorapobautomation9760 2 года назад

    Good Thank you

  • @aminfathy216
    @aminfathy216 2 года назад

    Thank you good one 👍.....>3

    • @electricalautomation
      @electricalautomation  2 года назад +1

      Thanks! I am very busy these days, the next video will be launched slightly delay, but will be.

  • @vatsalthaker2122
    @vatsalthaker2122 2 года назад

    Hello sir... please resume the series....

    • @electricalautomation
      @electricalautomation  2 года назад +1

      Thanks watching, yes, the Step3 will be launched tomorrow. I am very busy these days, sorry for releasing delay.

  • @dmitrijbozhok
    @dmitrijbozhok 2 года назад

    Good afternoon. Does anyone have a SINAMICS Startdrive V14 SP1 S120 under TiaPortal V14 SP1?

    • @electricalautomation
      @electricalautomation  2 года назад

      support.industry.siemens.com/cs/document/109746466/sinamics-startdrive-v14?dti=0&lc=en-WW
      support.industry.siemens.com/cs/document/68034568/sinamics-startdrive-v14-sp1?dti=0&lc=en-DE