Danfoss Drive Programming || Start/ Stop || Speed up & Speed Down

Поделиться
HTML-код
  • Опубликовано: 3 янв 2025

Комментарии •

  • @kamlesharmo2039
    @kamlesharmo2039 Год назад +2

    Alarm reset kaise karte hai uska video banaiye sir

    • @TechnicalManas1
      @TechnicalManas1  Год назад

      Aap alarm reset nehi kar sakte ho.... Agar kuch alarm show ho raha hai, wo dekh k apko action Lena padega. Alarm hai trip ka previous stage . Iska matlab aap ko awareness deta hai ki yeh fault a sakta hai.

  • @pratyushkumarbej5997
    @pratyushkumarbej5997 2 года назад +1

    Great sir ❤️

  • @baikunthalenka2776
    @baikunthalenka2776 Год назад

    Please upload more video in danfoss drive

  • @INSTRUMENT_GYAN
    @INSTRUMENT_GYAN Месяц назад

    Sir field me RPM indicator me RPM show karna ho to kon sa parameter setting karna hoga

  • @coffeecomplex9571
    @coffeecomplex9571 Год назад +1

    Hey brother i learned alot from your videos never in life worked on any vfd but i learned alot from you
    I changed ramo up and ramp down but i am getting W7 and W8 warnings 😢

    • @TechnicalManas1
      @TechnicalManas1  Год назад

      Thank u for your valuable comment.
      W7 - is Over voltage
      W8- is under voltage.
      I think the value of Ramp Down which u set is too short . Plz increase the ramp down and ramp up time and warning will be gone.

    • @coffeecomplex9571
      @coffeecomplex9571 Год назад

      @@TechnicalManas1 Thankyou bro, the Alarm is gone but the warning is still there 😭

  • @surajkanwar3611
    @surajkanwar3611 Год назад +1

    Please full video banaiy sir

  • @prlove3845
    @prlove3845 2 года назад +1

    VFD me kon kon se fault aata he us pe bhi video bnao

  • @starlinkservice-bj1lw
    @starlinkservice-bj1lw Год назад +1

    Sir. Can you please make a video of the complete setup of Danfoss drive vlt?

    • @TechnicalManas1
      @TechnicalManas1  Год назад

      There have 3 videoes..... there have also a video on Digital Input & out put configuration.

    • @baikunthalenka2776
      @baikunthalenka2776 Год назад

      ​@@TechnicalManas1 send mora give link

  • @RajnikantKapdi-hi2uz
    @RajnikantKapdi-hi2uz Год назад +1

    Push button se chalu nay ho raha he konsa parameter dalna he plz bataye

  • @sajid4upn
    @sajid4upn 2 года назад +1

    Sir thank you for your informative video pls keep posting it encourages us I have Danfoss VLT FC102 250kw iam facing issue in DC Over Voltage A7 error I have increased the Ramp Down time but still the problem exist could you pls share your experience I will be thankful to you

    • @TechnicalManas1
      @TechnicalManas1  2 года назад +1

      You have to check following things
      1. Input voltage should not greater than 415 v
      2. If not solve you can use DBR( Dynamic Breaking Resistor)
      3. Set the acceleration and deacceleration time 20 sec.
      Can you tell me the application of your motor drive?

    • @sajid4upn
      @sajid4upn 2 года назад

      @@TechnicalManas1 Thank you for your prompt response below things I have done
      Increased the Ramp Up time from 8sec/12sec
      Increased the Ramp Down time from 8sec/30sec
      Increased parameter 4-16 Trip Delay at Inverter Fault
      Activated function in parameter 2-10 Brake Function
      Brake Resistor unable to install due to no option available in Hardware Board
      Application : Mycom Compressor 250kw

    • @sajid4upn
      @sajid4upn 2 года назад

      Input Voltage is 360/380volts

    • @baikunthalenka2776
      @baikunthalenka2776 Год назад +1

      Thanks for share your knowledge

    • @pradipdhapare2027
      @pradipdhapare2027 Год назад

      😊😊😊😊😊9

  • @sreekanth3710
    @sreekanth3710 22 дня назад

    How can manual setting parameter

    • @sreekanth3710
      @sreekanth3710 22 дня назад

      Manual mode running parameter setting

  • @sujaypatil6090
    @sujaypatil6090 Год назад +1

    Sir, when i remotely Stop the motor,the HMI shows stopand the current and speed slows down but due to its not getting stop in time the motor trip and alarm shows illegal motor current.

    • @TechnicalManas1
      @TechnicalManas1  Год назад

      First check the deacceleration time. If it higher .... Please set it 10 to 15 sec

  • @vickeysingh6725
    @vickeysingh6725 2 года назад

    Danfoss micro vlt drive me al13 alarm ko kaise troubleshoot karenge

  • @mohsinjunakiya7547
    @mohsinjunakiya7547 Год назад +1

    W49 speed error ati he kya problem ho sakta he

    • @TechnicalManas1
      @TechnicalManas1  Год назад

      Aap ka Drive ki application kaya hai ?

    • @mohsinjunakiya7547
      @mohsinjunakiya7547 Год назад

      @@TechnicalManas1 jab normal condition hoti he tab frequancy batata he drive

    • @mohsinjunakiya7547
      @mohsinjunakiya7547 Год назад

      @@TechnicalManas1 jab 3 ganta motor ko bandh rakha uske bad chalu kiya to chalu ho gaya .

  • @ganeshmahato4467
    @ganeshmahato4467 2 года назад +1

    How to reset after trip

  • @prlove3845
    @prlove3845 2 года назад +2

    Iska drawing ka pdf or isko kese padhte he is pr bhi video bnao

  • @navinkumarrajput1763
    @navinkumarrajput1763 Год назад +1

    Ye setup pura nahe huya he esko pura karao

    • @TechnicalManas1
      @TechnicalManas1  Год назад

      Agar kuch baki reh gaya toh plz suggest kijiye 🙏

  • @k.keshavareddy1433
    @k.keshavareddy1433 2 года назад +1

    Alarm problem solution by

    • @TechnicalManas1
      @TechnicalManas1  2 года назад

      You have to check the particular problem. Which alarm it shows.

  • @ahtishamamjad6170
    @ahtishamamjad6170 2 года назад +1

    Yaar aap apna wattssapp number day sktay ho kya

    • @TechnicalManas1
      @TechnicalManas1  2 года назад

      Aap yaha pe boliye... Main ak wapp group create karunga then aap sabhi ko link de dunga

    • @ahtishamamjad6170
      @ahtishamamjad6170 2 года назад

      @@TechnicalManas1 bhai danfoss 5000 operator k saath jo motor hai wo start nhi ho rhi

    • @ahtishamamjad6170
      @ahtishamamjad6170 2 года назад

      Or saath main likh kr aarha hai k earth fault

    • @baikunthalenka2776
      @baikunthalenka2776 Год назад +1

      ​@@TechnicalManas1 group create kiye kya

    • @TechnicalManas1
      @TechnicalManas1  Год назад

      Group Create nehi Kiya. Aap instgram mai call kar sakte hain. If any doubt.