REVERSE DIAL INDICATING ALIGNMENT | CROSS DIAL FORMULA METHOD ENGLISH Rotating and Static Equipments
HTML-код
- Опубликовано: 1 ноя 2020
- TOPICS EXPLAINED:
REVERSE DIAL INDICATING ALIGNMENT FORMULA AND GRAPHICAL METHOD COMPLETE PROCEDURE AND DEMONSTRATION WITH EXAMPLE READINGS, PRE-ALIGNMENT PROCEDURES, BAR SAG, SOFT FOOT, CROSS DIAL POSITION FORMULA METHOD, VERTICAL MOVEMENT, HORIZONTAL MOVEMENT, ALIGNMENT CALCULATION, ALIGNMENT CORRECTIONS.
Join this channel to get access to perks:
/ @rasetech
REQUIRED TOOLS:
DIAL CLAMP FIXTURES, DIAL INDICATORS, STEEL RULER, MEASURING TAPE, TRY SQUARE, FEELER GAUGE, MAGNETIC STAND WITH DIAL INDICATORS, VERNIER CALIPER, OUTSIDE MICROMETER, INSIDE MICROMETER, SPIRIT LEVEL, MIRROR, PRE-CUT SHIMS, SPANNERS, AND TORQUE WRENCHES.
SUBSCRIBE FOR MORE ROTATING AND STATIC EQUIPMENT VIDEOS.
/ @rasetech
RIM AND FACE ALIGNMENT FORMULA METHOD | ENGLISH
• RIM AND FACE ALIGNMENT...
HOW TO FIX SOFT FOOT ON SHAFT ALIGNMENT | ENGLISH
• HOW TO FIX SOFT FOOT O...
BASIC OF ANTIFRICTION BEARING | ENGLISH
• BASIC OF ANTIFRICTION ...
CENTRIFUGAL COMPRESSOR DRY GAS SEAL SUPPLY SYSTEM | ENGLISH
• CENTRIFUGAL COMPRESSOR...
MECHANICAL SEAL ASSEMBLING PROCEDURE | ENGLISH
• MECHANICAL SEAL ASSEMB...
STUFFING BOX SQUARENESS | BORE CONCENTRICITY | ENGLISH
• STUFFING BOX SQUARENES...
STUFFING BOX ASSEMBLY | CENTRIFUGAL PUMP | ENGLISH
• STUFFING BOX ASSEMBLY ...
CENTRIFUGAL PUMP OVERHAULING PROCEDURE | ENGLISH
• CENTRIFUGAL PUMP OVERH...
HOW TO FIX SHAFT ALIGNMENT SOFT FOOT
• HOW TO FIX SHAFT ALIGN...
BAR SAG | ALIGNMENT
• BAR SAG | ROD SAG | S...
RIM AND FACE ALIGNMENT FORMULA METHOD
• RIM AND FACE ALIGNMENT...
RIM AND DOUBLE FACE DIAL ALIGNMENT FORMULA METHOD
• RIM AND DOUBLE FACE DI...
BELT DRIVE PULLEY ALIGNMENT STRAIGHT EDGE METHOD
• BELT DRIVE PULLEY ALIG...
RIM AND FACE DIAL ALIGNMENT TOOLKIT FOR META FLEX COUPLING
• RIM AND FACE DIAL ALIG...
CENTRIFUGAL COMPRESSOR DRY GAS SEAL SUPPLY SYSTEM
• CENTRIFUGAL COMPRESSOR...
RECIPROCATING COMPRESSOR PISTON OVERHAULING PROCEDURE
• RECIPROCATING COMPRESS...
CENTRIFUGAL MULTISTAGE PUMP ROTOR IMPELLER ARRANGEMENT
• CENTRIFUGAL MULTISTAGE...
HEATLESS DESICCANT AIR DRYER AND OPERATING TIME SEQUENCES
• HEATLESS DESICCANT AIR...
STUFFING BOX SQUARENESS|BORE CONCENTRICITY|SHAFT RUN OUT
• STUFFING BOX SQUARENES...
HOW TO SELECT SPANNER SIZE FOR BOLTS AND NUTS | INCHES TO MM | MM TO INCHES
• HOW TO SELECT SPANNER ...
DUPLEX BEARING ARRANGEMENT IN SINGLE ROW ANGULAR CONTACT BALL BEARING
• DUPLEX BEARING ARRANGE...
#reversedialindicatingalignmentmethod
#rotatingandstaticequipments
#graphicalandformulamethod
#rotating
nicely explained!! Simply Superb
Thanks a lot for the answer
Exllent explain .Good job brother.
Excellent video
Great 👍👍👍👍
thank you so much
Thank you sir.
Excellent Bhai
Good explain 🤔
Thanks alot sir
Sir good msg❤❤❤❤❤ i like it very nice 👍 ji use full
Super
This is great sir, thanks very much.
You are most welcome sir...❤
Dear Friends,
Recently I have uploaded the Hindi version of this video on our channel. Kindly please check it out. Many thanks for your support.
ruclips.net/video/Fkz39DUdseU/видео.html
I believe there is a mistake for horizontal correction since just from your horizontal reading it is obvious that you need to move the motor from left to right to correct the horizontal misalignment, kindly check pls.
Dear Friends,
Recently I have uploaded the Tamil version of this video on our channel. Kindly please check it out. Many thanks for your support.
ruclips.net/video/PvDPVeTUPA4/видео.html
horizontal first and the next is the vertical much better.....
centering first before shiming
❤❤❤❤❤
Very nice practical explanation sir !
Can you please explain in case of axial play motors for correct understanding of DBSE and Magnetic center positioning of Motor Rotors in Reverse dial alignment procedure.
Dear sir,
Heavy motor only radial bearing occupied no thrust bearing. Because due to magnetic field rotor Rotating axial.mosstly manufacture gave rotor centre Position with marking...to correct dbse or dbff while rotor is centre Position.. initially u correct the dbse and dbff then u start the alignment boss
Sir is there any video for thermal growth offset alignment method? The manufacturer give offset reading value after that dial alignment will done.
Thank you for the answer. I have another question, if you were kind during the operation, are the motor screws tight or loosen. Thanks
During the operation all base bolts of motor should be tightened...
Thank you for this good explanation. I am from Algeria. Is it possible to rotate the shaft of the motor alone and then rotate the shaft of the pump alone while taking measurements? Thanks
No Its not possible as per this method...
Whats the bar sag value ?
Sir can we set the alignment
with single dial gauge by step by step
Why in this formula method the bar sag value and the 180 degree of sm mm value was not divided by 2. I saw graphical method on that video the value is divided by 2 plz explain sir.
It passible to use only one dial gauge?
Yes. But you cannot correct the misalignment thoroughly. Its like a bypassing.
How come -0.14 /2 equal to 0.07
sorry sir, Can you proof where the formular from please. I Cant proof that by myself. Thank you
Can you share the notes that you used in the video?
Dear Sir,
I kept these papers in my home now I am in abroad. So Now I cant able to send these soft copy to you... apologize for the same. even I want to search the related papers from my room. You can take notes from the video or you can take screen shot. Thank you for understanding ❤
@@rasetech thank you so much for your reply, yes i took screenshots and i am working on it, can you share your email i might need your help regarding shaft and coupling allignment.
Is there a book to refer mechanical maintenance?
I dont know about reference books for mechanical maintenance. Sorry bro
@@rasetech its ok. Good videos.
There are very good books by Heinz P. Bloch on maintenance, but those are expensive. You could check those on Amazon. Link: amzn.to/3A9mvs3
Pls discussion in telugu sir
Dear sir sorry I dont know telugu
Sir please tell us about the + and - TIR,ASLIKE SM=. -•14,MM=. +•42
Sir ,if I use single dial gauge how I doing this, and my coupling distance is two mili Pls help
How about the dial indicator position...? Are you looking for Radial or Axial...?
Sir I use Axial
@@donignasis8355 then you need to do by practical method only...
@@donignasis8355 take Axial TIR reading and correct the axial misalignment...
Ok sir I’ll try thanks
Sir pls discuss in hindi
Noted with thanks ❤
Tamil language
Dear Sir
Thanks for your comment. Tamil version already uploaded. Kindly check it out.
ruclips.net/video/PvDPVeTUPA4/видео.html
Wherer r u?
Yes sir,what can I do for you?
Sir, plz hindi me banaie
Sure sir... I will do it....
@@rasetech thank u sir to make video in hindi version related to alignment
@@kumarsanjit8833 you are most welcome...❤
Hello sir this is naidu my sir told me sm+mm I saw the your video sm-mm which one is correct please reply me
It will change according to the alignment method... please check the alignment method... cross dial or opposite side dial..?
@@rasetech no same as your video in your video what type opposite or cross
I explained both that is why i am asking....
@@rasetech sir what is the difference between cross and opposite
Sir can I do same as you please reply me