Concrete Quality Control Test at Site - Slump Test

Поделиться
HTML-код
  • Опубликовано: 19 окт 2024
  • The slump test is a means of assessing the consistency of fresh concrete. It is used, indirectly, as a means of checking that the correct amount of water has been added to the mix. The test is carried out in accordance with BS EN 12350-2, Testing fresh concrete.

Комментарии • 108

  • @qualityengineersguide
    @qualityengineersguide 4 года назад +6

    What is the designed slump? Otherwise, the slump is too high and is rejected. To resolve a high slump is to give another time to roll the drum again for 5 mins and then check the slump again. I can see a lot of manpower here to do a slump test. It should be 1 concrete technician to do the slump test and 1 helper to manage the transport of fresh concrete to the cube making area.

    • @AmeerAzwan
      @AmeerAzwan 3 года назад +1

      Yeahh u right bro!!

  • @justintilley6
    @justintilley6 5 лет назад +12

    This would not fly if an inspector was watching 😂😂

    • @gsingh1411
      @gsingh1411 3 года назад

      he was wildin ... def aint gon fly

    • @michaelb3581
      @michaelb3581 Год назад

      That was my first thought.

  • @donaldpump3338
    @donaldpump3338 2 года назад +2

    Why all the comments about the slump collapsed. Well yeah it does that, you guys only pour 0 slump don't get it?

  • @christophertunusau3023
    @christophertunusau3023 11 месяцев назад

    Slump test is basically for Concrete mix workability.
    -not too dry.
    -not too watery
    But just right to move and mix thoroughly and easily workable.

  • @hlahlakhonziwe2240
    @hlahlakhonziwe2240 2 года назад +1

    Am interested to know what causes it to collapse, as in other cases we obtain true slump or shear slump.

  • @Californian423
    @Californian423 7 месяцев назад +1

    This slump test is not valid per ASTM 143 , this technician is not competent as they did not add concrete in 3 equal layers by volume the third layer was only one scoop where as first and second layers were 2 scoops full of concrete

  • @Safar.369
    @Safar.369 6 лет назад +5

    it depends on the application of the concreter mix it can vary from 4 cm difference up to 18 cm

    • @HumongousGuy
      @HumongousGuy 10 месяцев назад

      speak american, but actually is my slump between 4 and 18cm? heres an example (_)_):::::::::::::::::::::::::::::::D~~~~~~

  • @thorjack1900
    @thorjack1900 5 лет назад +2

    Very good concrete quality 🙂

  • @zillionz
    @zillionz 4 года назад +2

    Where are your gloves - concrete is extremely hazardous in contact with skin... obviously no safety officer present on that site!

  • @kurma.2021.wangen
    @kurma.2021.wangen Год назад

    Jadi inget waktu d Lab 1997, semangat 👍👍

  • @africaswildlife7869
    @africaswildlife7869 4 года назад +10

    You measuring a collapse slump? 🤣🤣🤣🤣

    • @donaldpump3338
      @donaldpump3338 2 года назад

      Are slumps collapse. we generally want a 7.5 slump when pouring polebases or anything fdot.

  • @dconstruction7099
    @dconstruction7099 4 года назад +1

    Best work my friend

  • @onlinetourguides1962
    @onlinetourguides1962 7 лет назад +2

    Sir how much defference required for the good slum ??

    • @F3st0
      @F3st0 6 лет назад +1

      arsalan mujtaba at a slump of 10-100 you have a +-15mm tolerance. @ 100-200mm slump you have 40. 300mm is the height of the slump cone there for a spread test would be done in place

    • @mikeconroe3328
      @mikeconroe3328 3 года назад +1

      Depends on what purpose and level of concrete different type of concrete usage

    • @samuraijack2189
      @samuraijack2189 2 года назад

      150-+30 bro

  • @taihtasu
    @taihtasu 6 лет назад +4

    Failed?

  • @pradeepwavhale5374
    @pradeepwavhale5374 6 лет назад +1

    Perfect video

  • @lowkeyzavaldor3592
    @lowkeyzavaldor3592 6 лет назад +10

    Why did it take 3 guys to do one simple slump test lmao

    • @RodneyO0.
      @RodneyO0. 4 года назад

      Because their measuring guy was not there yet had to go with only 3 least they took their time and did it excellent

  • @jamesheusner8113
    @jamesheusner8113 7 лет назад +3

    He tamed each layer 25 times just like a training video I watched but did not wait the two minutes before lifting. how does that affect the results?

    • @grahamhanbury9427
      @grahamhanbury9427 6 лет назад +3

      You dont wait 2 minutes, you hold the slump cone in place and pull come im a 5 second county. Then measure displaced center from the lip of the flippedf cone. They honestly butchered this test. Also id wager a plasticizer was involved in this batch of ready mix. Would have been useful information for those watching.

    • @F3st0
      @F3st0 6 лет назад +1

      Also the cone and plate are too wet. Only meant to be damp. So this test is inaccurate also.

    • @HumongousGuy
      @HumongousGuy 10 месяцев назад

      it doesnt

  • @signaltouch7413
    @signaltouch7413 3 года назад +1

    c143 is not valid for over 6" slump, The deputy can't stop a job just fill a report , in the real world of inspection there are many clowns and this is sad.

  • @riznarizna7989
    @riznarizna7989 Год назад

    What is grade

  • @abdulahad6766
    @abdulahad6766 7 лет назад +2

    ok thank you so what is the mean of w/c water per cement

    • @khangaletshivhase8034
      @khangaletshivhase8034 5 лет назад

      abdul Ahad this is the ratio between water and cement. The less the ratio is the stronger the cement is.

  • @goodman5016
    @goodman5016 6 лет назад

    What is the result? The concrete ready to pour formwork?

  • @harrickvharrick3957
    @harrickvharrick3957 3 года назад

    This does not indicate precisely what is in the mix, does it. It indicates most of all how much water is in it. With less water in it and certain specific types of sand you may get a real sturdy substance that don't flow much and there also are types of sand that will not want to keep stuck together much. I think is rather the colour that gives you indication of whether enough to of the other ingredients are present - more or less.

    • @kellybell9235
      @kellybell9235 2 года назад

      The slump test is precisely to determine how wet the concrete is. If too wet all the fine sand and concrete will separate from the aggregate making the concrete weak. Cylinders of concrete are also filled to be broken at 7 and 28 days to confirm the strength. The slump test is performed before pouring to reject concrete that is too wet .

  • @donaldpump3338
    @donaldpump3338 2 года назад

    Why do you need all that concrete in the wheel barrel. I'd tell the driver to slowly roll it to the front. Remember they work for you don't let them dump all that concrete. Especially for what 7 cylinders a slump weight and air test!

  • @keys2la
    @keys2la 7 лет назад +22

    Concrete mixture was Too Wet!

    • @WarunaThejana
      @WarunaThejana  7 лет назад +2

      Design Slump was 150-200 mm

    • @karthikkuppa1187
      @karthikkuppa1187 6 лет назад

      yeah why because the percentage of water was more...........

    • @rashidhabib5795
      @rashidhabib5795 6 лет назад +1

      May b this slump 180 mmm

    • @grahamhanbury9427
      @grahamhanbury9427 6 лет назад

      Id wager super was involved. If not most mix designers wont back up a slump like that. Fyi this was a butchered slump test on a good day. Not picking but if i saw this on a job site. I would be making phone calls to a site super.

    • @donaldpump3338
      @donaldpump3338 2 года назад

      Depends on what they are pouring. You wouldn't want a 4 inch slump on a dot wall panel noise barrier 610 ect. Bug holes everywhere lol.

  • @RJMDesigns
    @RJMDesigns 6 лет назад +4

    it looks like 8" slump +- 1

  • @abdulahad6766
    @abdulahad6766 7 лет назад +3

    what is the mean of slum test

    • @WarunaThejana
      @WarunaThejana  7 лет назад +4

      The slump test is a means of assessing the consistency of fresh concrete. It is used, indirectly, as a means of checking that the correct amount of water has been added to the mix.

    • @JohnSmith-ok9sn
      @JohnSmith-ok9sn 7 лет назад +9

      abdul Ahad
      It is a measure of the 'fluidity', or, how much water is in the mix - the more water, the more 'fluid', soupy, the mixture is.
      Slump is measured in inches - 1 inch slump, (very thick mixture), used for road curbs, for example, where the mixture is needed to sit in the form, without spreading to the sides too much. Footings, on the other hand, may require 4-5 inch slump, (to fill into every corner of the forms, as they pour it).
      The thicker is the concrete mix, the higher the top of the concrete 'cone' will be from the ground, (the closer to the top of the metal cone), so, if the difference between the TOPS of the two cones, (metal, and concrete mix), is 1 inch - you have a 1-inch slump, 2 inches - then, 2-inch slump, 3-4-5 inches - correspondingly.
      The guys in the video had something like 7-inch slump, (which is VERY 'soupy'!). Depending on the country, (latitude), you have to remember to adjust for the ambient heat, humidity, etc..., because, by the time you will have arrived from the plant to the job, you may lose up to 2-3 inches of slump, (the mix will get thicker), due to the heat, air humidity/dryness, etc...
      Those guys where in India, or Pakistan, where it is, naturally, way hotter than, say, in Chicago, IL, therefore, (if the job is far away from the plant), they had to put more water, at the plant, while loading the initial mix, to compensate for the high heat, and low humidity, (if it was in the inner parts of the country), but, to me, it looks like they overdid it, a little. But, hey, I don't know what kind of job they were doing, so, who am I to judge, right? 😃

    • @tetog70
      @tetog70 7 лет назад +1

      Waiki Boy thanks that was the information i needed jus started drivin a cement truck didnt understand what a slump was or why there was inches

    • @user-pd1wk5wq8z
      @user-pd1wk5wq8z 7 лет назад +1

      which slump is best for construction?less fluid or more fluid? and whats is grade 53, 54 etc?

    • @WarunaThejana
      @WarunaThejana  7 лет назад +2

      Optimum Slump value depends on our application.If we need high workability we need more water.That means high slump value. But we need to consider about the water cement ratio of concrete because it determine the strength of concrete."Grade" is the 28 day cube strength of concrete.

  • @Sauske2101
    @Sauske2101 2 года назад

    Soooooo did it pass? 😶‍🌫

    • @Californian423
      @Californian423 7 месяцев назад

      Slump test was not valid plus passing depends on specified slump

  • @jongaming4267
    @jongaming4267 3 года назад

    What tool is that

  • @civiltechnontech3147
    @civiltechnontech3147 7 лет назад +1

    very good

  • @xscafe
    @xscafe 6 лет назад +3

    Too much water, shear failure. No need to test for failed material. No Gloves! Poor mixing, once it is mixed in revolving truck, he should not mix it again.

    • @donaldpump3338
      @donaldpump3338 2 года назад

      It's required to mix in the wheel barrel per aci. I didn't see a thermometer though before slump.

  • @chinmayabehera7399
    @chinmayabehera7399 6 лет назад

    The lifting time of slump should be 5 to 10 sec.....If you are making the youtube video, you should follow the standard procedure.

    • @WarunaThejana
      @WarunaThejana  6 лет назад

      The test is carried out in accordance with BS EN 12350-2, Testing fresh concrete.

    • @TreePuncherGuy
      @TreePuncherGuy 5 лет назад +6

      CHINMAYA BEHERA it’s actually 5 +/- 2 seconds

    • @donaldpump3338
      @donaldpump3338 2 года назад

      5+-2 is correct 10 seconds nope fail!!!

  • @lyngracejamila6562
    @lyngracejamila6562 5 лет назад +3

    Wrong Method of Testing,.. 100% Failed

  • @khangaletshivhase8034
    @khangaletshivhase8034 5 лет назад

    Collapsed slump test the workability of this concrete is very bad

  • @hamzaaltaf398
    @hamzaaltaf398 3 года назад

    In UAE my work 6 years experience

  • @1313-l5x
    @1313-l5x 5 лет назад

    Cadê a luva????

  • @Sdwhatitdo
    @Sdwhatitdo 4 года назад +2

    I wouldn’t pass that

  • @vishnupvijay6990
    @vishnupvijay6990 6 лет назад +2

    paani jyada he ismein water cement ratio sabse jyada he

  • @jtspiky
    @jtspiky 2 года назад

    i just want to know why the fuck you need so much concrete in the wheel barrow if you're not going to use it all

  • @migertkello3032
    @migertkello3032 4 года назад

    Was a collapsed slump

    • @donaldpump3338
      @donaldpump3338 2 года назад

      Dude so if the slump didn't collapse you would have a 0 slump not everyone pours on vibraboards. How could a 0 slump even have workability if it were a wall panel. That pour would be an absolute disaster.

  • @HussamAldeen
    @HussamAldeen 5 лет назад

    Wrong concret . Test faild

  • @vivekpatere534
    @vivekpatere534 5 лет назад +2

    Concrete has been collapsed

  • @papalathuekungsarini
    @papalathuekungsarini Год назад

    😮😮 TO MODE WORK MAKE SURE

  • @marklopez1256
    @marklopez1256 4 года назад

    I do , slump , weight , air ,temp & cylinder molds in under 15 mins . Come on man lol 🤣

    • @Aphakiastudies
      @Aphakiastudies 3 года назад

      Dayyuuumm boiii, u must be ACI certified 😆

  • @engineerfaisal1045
    @engineerfaisal1045 4 года назад

    Collapsible slump

  • @palak6513
    @palak6513 4 года назад +1

    Test is fail 🙄🙄

  • @mohibkhan4593
    @mohibkhan4593 7 лет назад +2

    It too mach bada three man worker has not leave handa golvess

  • @kulithsk9714
    @kulithsk9714 5 лет назад

    no gloves no safety

  • @vijaybabu4119
    @vijaybabu4119 7 лет назад

    sannasi plate and goura pina water unadbuta sannasi

  • @sujonkumar6541
    @sujonkumar6541 Год назад

    😂 collaps slump

  • @adimasoom8
    @adimasoom8 6 лет назад

    shear slump 👆

  • @xmn1460
    @xmn1460 6 лет назад

    very bad.collapsible slump.

  • @lowkeyzavaldor3592
    @lowkeyzavaldor3592 6 лет назад

    S4 top end

  • @asgharalikhan3123
    @asgharalikhan3123 5 лет назад

    Not Acsftbal this concert

  • @bablubablu-tj3gj
    @bablubablu-tj3gj 4 года назад

    Sefty Kota

  • @yayaed8428
    @yayaed8428 4 года назад

    This well not past

  • @shiptj01
    @shiptj01 2 года назад

    Failed.

  • @TheMohadam
    @TheMohadam 2 года назад

    Failed

  • @firemedic947
    @firemedic947 2 года назад

    That's some crappy concrete...

  • @rung6650
    @rung6650 3 месяца назад

    Nogood

  • @evg.aneeshpanachamoodu7592
    @evg.aneeshpanachamoodu7592 5 лет назад

    Don't west

  • @arsallahmajedi9766
    @arsallahmajedi9766 Год назад

    Unprofessional testing

  • @ssajid40
    @ssajid40 7 лет назад

    gloves pena karo

  • @bubugg4210
    @bubugg4210 4 года назад

    yikes

  • @AmeerAzwan
    @AmeerAzwan 3 года назад

    Shit!! Fail slump

  • @googleuser3782
    @googleuser3782 11 месяцев назад

    lol are these people professionals?

  • @canontom874
    @canontom874 6 лет назад +1

    Failed