I am watching your videoes from very starting bhaiya, i also want to become a electrical engineer from my childhood, i also make same videoes like you.
AK sawal hai sir g k AK motor agr star design hai mtlb 415 Y ye likha hua hai name plate per to usko delta main Kyo nai chala skty uska load 500 persemt ya is sy b zayada Kyo beth jata hai r overload trip na hny ki Kya wja hai?? R Sath he ys b btay k 415 delta wali motor star main chal jati hai ya wo b lazmi phr delta main he chalani ho gi??
Sir Star delta saterter mai to pahele star mai Motor Run hota hai ? Q star mai run hota hai pahele pahele to motor run hone ke liyai jya da current jorut hota hai
Sir g...kisi bhi moter ko fitt Hui jagh pe hi welding karna theek hai ya nahi...jese ki iron coupling losse ho..or hm uspe welding se taanka lgana theek h k na .... winding pe to koi fark nahi padta
Agar aapke paas phase to phase supply 220 v hai to vah motor delta mai or phase to phase 400 v hai to star mai chalaya jata hai kahne ka matlab ye hai ki her condition mai प्रत्येक coil mai 220 v milna chahiye hamaare India mai line voltagr 400 rahta hai to star mai chalegi or foriegan mai line voltage 220 v rahne per delta mai chalaate hai
Bhai koi bhi motor ka rpm winding pole or frequency ke uper depend rahta hai na ki star ya delta conection ke uper agar motor ke dataplate mai jis tarah se conection bataaya gaya hai usi conection mai chalana chahiye star conection ko delta mai ya delta conection ko star mai chalaane per motor ke output mai farak aata hai or input current mai bhi farak aata hai jisse motor jaldi kharaab ho jaate hai star delta starter se chalne vaala motor bhi delta conection hi rahta hai lekin starting current ko kam rakhane ke liye kuch second ke liye star mai chalta hai uske baad vah motor load mai permanent delta conection mai hi chalti rahti hai jab tak ki starter ko band na kiya jaaye
10 hp motor hai or 22 inch ka aata chaki Tu mein is ko belt mein convert karna chah rha hu motor ki rpm speed 1450 hai Mein 10/11 A per chalta hu .yani star mein Belt k sath bhi star mein chala skta hu Plz reply💓
Connection ke liye jab 6 tar bacte hai tab unme se ek chod ek tar ko milaya jata hai ise hi star connection khete hai hai bhai isliye ye aapas me shot krne pr bhi shot circuit nhi hota hai
Thanks for sharing this.
Love from Bangladesh. ❤️
ruclips.net/user/shortsz2LQvhvJe0U?feature=share
ruclips.net/video/Em0k1kWvc0k/видео.htmlsi=y-NgFPzslqCGIHtX
Very good bhai dil jit liya tumne 🙏🙏🙏🙏
ruclips.net/video/Em0k1kWvc0k/видео.htmlsi=y-NgFPzslqCGIHtX
Very good advice sir mai bahut kaam sikha❤ hu aap ka videos se ❤️❤️❤️❤️🙏🙏🙏🙏🙏❤️❤️
ruclips.net/video/Em0k1kWvc0k/видео.htmlsi=y-NgFPzslqCGIHtX
YOUR INFORMATION IS VERY USEFUL
Bhot acchi jankari diya sir aapne
Sir u r great ❤️ mujhe bohot fayida hua hai apki videos se thanks sir hatts off
ruclips.net/user/shortsz2LQvhvJe0U?feature=share
ruclips.net/user/shortsAdW8fEQrVJE?si=wsmiprjoVdaHjqCf
جزاكَ اللّٰه خيرً
ruclips.net/video/Em0k1kWvc0k/видео.htmlsi=y-NgFPzslqCGIHtX
I am watching your videoes from very starting bhaiya, i also want to become a electrical engineer from my childhood, i also make same videoes like you.
सच में सर बहुत अच्छे तरीके से समझाते हैं
May You Become a Successful Engineer and Take a Job as Engineer in Public Sector.
Bhai mat soch banne ki pachtayega
@@abhishekmaurya2k halo
ruclips.net/user/shortsAdW8fEQrVJE?si=wsmiprjoVdaHjqCf
Very nice👍👍
Love from Andhra Pradesh state, Vijayawada ✅
Bht achhi explanation.Thanks Sir. Plz carry on delivering valueable technical knowledge.
Regards
ruclips.net/user/shortsz2LQvhvJe0U?feature=share
Good advice sir 🙏
Sir iam big fan of electrical dost please reply me sir❤️
Good sir aise hi
ruclips.net/video/Em0k1kWvc0k/видео.htmlsi=y-NgFPzslqCGIHtX
Very good. Thanks 🙏🙏🙏🙏
ruclips.net/video/Em0k1kWvc0k/видео.htmlsi=y-NgFPzslqCGIHtX
Nyc video sir 👌
Great job bro... I always keep waiting ur video
very well explained 👌👌👍
ruclips.net/user/shortsAdW8fEQrVJE?si=wsmiprjoVdaHjqCf
Thank You Sir 🙏🙏🙏🙏
ruclips.net/video/Em0k1kWvc0k/видео.htmlsi=y-NgFPzslqCGIHtX
Sir,useful information.
ruclips.net/video/Em0k1kWvc0k/видео.htmlsi=y-NgFPzslqCGIHtX
Very informative video
Nice extremely informative videos
ruclips.net/video/Em0k1kWvc0k/видео.htmlsi=y-NgFPzslqCGIHtX
Good teaching
ruclips.net/video/Em0k1kWvc0k/видео.htmlsi=y-NgFPzslqCGIHtX
👍👍👍👍
You are Soo great sir
too good ❤❤
Great information ❤
ruclips.net/video/Em0k1kWvc0k/видео.htmlsi=y-NgFPzslqCGIHtX
Nice 👍
ruclips.net/video/Em0k1kWvc0k/видео.htmlsi=y-NgFPzslqCGIHtX
Aapka aawaj bahut hi madhur hai sir
Very nice video, Thanks
ruclips.net/video/Em0k1kWvc0k/видео.htmlsi=y-NgFPzslqCGIHtX
Love from odisha
Good
Very very nice Sir ji🙏
ruclips.net/video/Em0k1kWvc0k/видео.htmlsi=y-NgFPzslqCGIHtX
very nice sir
Sir please make one video on Alternator & transformer protection
sir AC me alectron farwd or revrs flow krty hain to wo flow kis time hoty hain wo to ak hi jgah khre rahen gy?
Hi
So sweet Sir.
Very useful video 👍🏻
Nice videos thanks
ruclips.net/video/Em0k1kWvc0k/видео.htmlsi=y-NgFPzslqCGIHtX
ruclips.net/video/Em0k1kWvc0k/видео.htmlsi=y-NgFPzslqCGIHtX
Nice Video
Very nice 👍
ruclips.net/video/Em0k1kWvc0k/видео.htmlsi=y-NgFPzslqCGIHtX
Nice brother...!!!
Good brother
एमपियर निकालने के लिए सिमपल सा ट्रिक है -kw×1.7=Full Lod Current
जैसे - 15×1.7=25.5 Amp
Good 👍
Sir transform ka star and delta connection ka upar ek vedio plz banoo plz sir plz sir 🙏
SIR breaker upar ki traf q on hota hy?
Àpko apne video mai practical experiment ve karke dekhyee mechanical student ko aur electric student ko bhut accha se samaj mai jyagaga
Good sir
Sir please make video about equivalent circuit and phasor diagram of 3 phase induction motor
ruclips.net/user/shortsz2LQvhvJe0U?feature=share
ruclips.net/user/shortsAdW8fEQrVJE?si=wsmiprjoVdaHjqCf
बहुत-बहुत dhanyvad
Awesome video
AK sawal hai sir g k AK motor agr star design hai mtlb 415 Y ye likha hua hai name plate per to usko delta main Kyo nai chala skty uska load 500 persemt ya is sy b zayada Kyo beth jata hai r overload trip na hny ki Kya wja hai??
R Sath he ys b btay k 415 delta wali motor star main chal jati hai ya wo b lazmi phr delta main he chalani ho gi??
Motor ko star men drive karna benifit hai ya Delta men drive karna
Hamara, India mein 17.7 lack electrician hai, 😮😮
Sir,star-delta starter main kiska current high rahega,star or delta ka?
Star ka jiyada ayega
Delta
Delta
Delta
ruclips.net/user/shortsAdW8fEQrVJE?si=wsmiprjoVdaHjqCf
Sir Star delta saterter mai to pahele star mai Motor Run hota hai ? Q star mai run hota hai pahele pahele to motor run hone ke liyai jya da current jorut hota hai
Great
Drive par. Bhi video banao bhai.
Sir please SFU par pless video bnaye 🙏
Thanks batane ke liye bhai
Aur agr star connection pe hai aur current increase ho jaye to kya motor m koi prblm ho skti hai
Bhaiya HMD ( delta sensor) ke bare me and working ke bare videos banao na
Kitna kw ka motar pe star and delta connection kar sakte hai
Sir g...kisi bhi moter ko fitt Hui jagh pe hi welding karna theek hai ya nahi...jese ki iron coupling losse ho..or hm uspe welding se taanka lgana theek h k na .... winding pe to koi fark nahi padta
Full welding nahi kar sakte normal taka mar sakte hai only
Delta motar ko genretor par chla skte h kya?
my dear sir motor plate pe lika hai ki 220 delta me aur 380 star me to kiya hum 380 me delta chala sakte hai small motor hsi
मत चलावो,फ्यूज उड जाते है,और वैसे जरूरी ही नही है,स्टार मे ही चलाना 380 पर
Agar aapke paas phase to phase supply 220 v hai to vah motor delta mai or phase to phase 400 v hai to star mai chalaya jata hai kahne ka matlab ye hai ki her condition mai प्रत्येक coil mai 220 v milna chahiye hamaare India mai line voltagr 400 rahta hai to star mai chalegi or foriegan mai line voltage 220 v rahne per delta mai chalaate hai
Sir ap clear kriye ...KW me hai ya HP me
Ye kafi lamba process hai pata karne ka star ye delta me calane ka koi aisa tareeka batiye jis ye keye begair ho jaye
जो भाई बहन इस विडियो को देख रहे है भगवान उनके माता पिता को लंबी उम्र दे 🙏
#techniciangopalji
Star men full raning motor ho jaye to motor ka rpm 1440 hi rahega ya delta ke mukable thoda rpm kam rahega
Bhai koi bhi motor ka rpm winding pole or frequency ke uper depend rahta hai na ki star ya delta conection ke uper agar motor ke dataplate mai jis tarah se conection bataaya gaya hai usi conection mai chalana chahiye star conection ko delta mai ya delta conection ko star mai chalaane per motor ke output mai farak aata hai or input current mai bhi farak aata hai jisse motor jaldi kharaab ho jaate hai star delta starter se chalne vaala motor bhi delta conection hi rahta hai lekin starting current ko kam rakhane ke liye kuch second ke liye star mai chalta hai uske baad vah motor load mai permanent delta conection mai hi chalti rahti hai jab tak ki starter ko band na kiya jaaye
I need the control wiring diagram of star delta starter with water level controller.
ruclips.net/user/shortsz2LQvhvJe0U?feature=share
Hello sir which connection takes more current plzz reply soon
Delta
@@electricaltechnicianingulf5299 1 question sir can i ask
10 hp motor hai or 22 inch ka aata chaki
Tu mein is ko belt mein convert karna chah rha hu motor ki rpm speed 1450 hai
Mein 10/11 A per chalta hu .yani star mein
Belt k sath bhi star mein chala skta hu
Plz reply💓
Sir maine kal ek question Kiya tha 11kv 33kv 3 phase wire me single phase me kitna voltage hota hai please bataiye
How make coil sequence on terminal please explain
Best
9 lead motor ki puri jankari jankari chahiye sir
Sir mera ek question hai star delta starter me contacted ka kaise define kare ki mtlb size main, star, delta contacted ka rating
Aapko motor ka input current nikaalne aana chahiye saath mai line current or phase current bhi nikalna padta hai
Bahut achcha hai video
Video nahi aa rahi hai aaj Kal kyun
Sarter dono me star delta hi lagana hoga kya
Sir, kisi Star delta motor ko DOL pe chalane se motor ki speed ya efficiency par koi farak padega??
Starting current bad jayega (full load current ka panch se chah guna) sath mai torque bhi bad jata hai
श्रीमान जी,जब हम तीनों कॉयल को एक तरफ से शॉर्ट कर देते हैं और दूसरी तरफ से RYB देते हैं तो शॉर्ट सर्किट क्यों नहीं होता हैं KINDLY क्लियर
भाई मुझे भी यही जानना है
Nutral ban jata hai
Bhai star or Delta mei line value or phase value ka bhi concept hota hai jiske hisaab se motor design hoti hai
Due to winding rasistance
Connection ke liye jab 6 tar bacte hai tab unme se ek chod ek tar ko milaya jata hai ise hi star connection khete hai hai bhai isliye ye aapas me shot krne pr bhi shot circuit nhi hota hai
sir strar connection me harek coil ko kitna volatage milage aur delta connection me kitna milega
Star मे 220 हर काॅईल को,एक फेज और काॅमन पाॅईंट याने की न्यूट्रल से,डेल्टा मे 425 दो अलग फेज सै,हर काॅईल गृप को
Sir 3 phase motor me star connection krenge to Jo neutral Crete hoga use kaha Connect krenege
Bhai aapko star conection karke uvw mai ryb supply dena hai or kuch nahi karna hai
Agar motor me star delta connection coil to coil same colour code ke sath ho to koi issue aayega
Red ke same red na karke coil to coil karenge to
❤❤❤
Sir genreter conection per video banao
Sir mujhe two speed motor diagram batana plz....
how can we run a three phas motor on single phase 220v
Electro magnet ganret hota jissy moter ghoomne lagti to vah short nahi rhti hai
Agar moter may current dene par ghooomegi nahi to short hogi try it
10Hp ki monoblock moter h or load 17to 20 leti h to star me jode ya phir delta me voltage 380to 415 aati h
Thinks
Water pump ha delta main 1.5 amp la rah usy star main concet Karon ya delta main he Shi ha
How to know whether our power is in ups or row in socket
10 hp motor run time a amp? And delta time amp?
It's to good
Agar supply face koi sa bhi kahi bhi lagade to kya hoga
Eot crain ko do jagahse kayse oprate kare