  • @jimnjele.bean-dayone3505
    @jimnjele.bean-dayone3505 10 месяцев назад +1

    I would have liked to see it in action. Thanks for showing how to make one

  • @renowden2010
    @renowden2010 2 года назад +6

    Correct me if I am wrong, but I think this is wired backwards. @14:00 You connect the HOT of the line cord to the switch then @23:45 you connect the lamp to the NEUTRAL of the outlet and @25:30 the HOT side of the outlet to the NEUTRAL of the line cord. Shouldn't the outlet be connected the opposite way around?

    • @fibberscloset498
      @fibberscloset498  2 года назад +2

      Good catch, West Penwith. It is backward.

    • @R.Akerman-oz1tf
      @R.Akerman-oz1tf 9 месяцев назад

      Electrically; no diff. You could have a 3-prong receptacle & a non-polarized "amplifier" Good luck being careful B/4 plugging it in.@@fibberscloset498

  • @SteveHacker
    @SteveHacker 3 месяца назад +1

    Why can’t the internal switch be kept? Isn’t it already in series with the outlet?

    • @fibberscloset498
      @fibberscloset498  3 месяца назад +1

      Good point. The switch is already in series with one side of the outlet.

  • @SDsailor7
    @SDsailor7 7 месяцев назад +1

    So do you need several incandecent light bulb according different wattages that you may have on several stereos or radios? anyone know?
    Also do you need to cut the tab/bus on the swith if it does not have an outlet attached?
    Or is it Ok to leave it like it came from the factory?
    Thank you

    • @fibberscloset498
      @fibberscloset498  7 месяцев назад

      As a guideline, you will want a bulb that is 1.5-2 times the wattage of the radio under test. For example, an AA5 radio might require around 30 watts, so you will want to use a 50-60 watt bulb. I'm not quite sure what you mean when you say, "if it does not have an outlet attached?" Do you mean the case where a switch and outlet are in the same factory housing?

  • @bones007able
    @bones007able 10 месяцев назад +1

    Then go out and find and stock obsolete light bulbs in various wattages