SINAMICS G120C DRIVE COMMUNICATION WITH SIEMENS S7-1200 CPU

Поделиться
HTML-код
  • Опубликовано: 15 дек 2024
  • HOW TO COMMUNICATE SINAMICS G120C WITH SIEMENS CPU S7-1200 OVER PROFINET?

Комментарии • 21

  • @zackk_54544
    @zackk_54544  Год назад

    Kindly share your feedbacks and suggestions

  • @luongcuong1582
    @luongcuong1582 3 месяца назад +1

    I want to ask you what version of tia portal have the "drives" section when we "Add new device" section? I used tia portal V16 but don't have Drives section when I add new device.

    • @zackk_54544
      @zackk_54544  3 месяца назад

      @@luongcuong1582 Hello Friend,
      To add any new device in your TIA program you have to install the GSd file for the devices. Then only it will reflect in TIA hardware catalog.
      Have you added GSD file for your drivea in TIA?

    • @luongcuong1582
      @luongcuong1582 3 месяца назад +1

      @@zackk_54544thanks for your response. My question is not related to gsd file, so I have find information in google and know that I have to install Start Driver Software to use same function as your video.

    • @zackk_54544
      @zackk_54544  3 месяца назад

      @@luongcuong1582 That's good friend you know about the starter installation. In case if you dont have starter installed you can perform the application by installing the GSD as well.

  • @amazighman9935
    @amazighman9935 6 месяцев назад +1

    Hi, I think that the DPRD and DPWR are only to be used in a PROFIBUS communication right ??

    • @zackk_54544
      @zackk_54544  6 месяцев назад +1

      Hello, these blocks are to be used for both profibus / profinet communication.

    • @amazighman9935
      @amazighman9935 6 месяцев назад

      @@zackk_54544 okay, thanks

    • @zackk_54544
      @zackk_54544  6 месяцев назад

      For more queries connect on Instagram
      All the best

  • @skysrivat
    @skysrivat 7 месяцев назад +1

    I have 1 query here. Why are we creating UDT with 8-15 bits of Cw first then with 0-7 bits of Cw? Is there any reason for it ? I feel some data gets transferred in byte format ?

    • @zackk_54544
      @zackk_54544  7 месяцев назад +1

      Siemens blocks has predefined bit structure for control/ status words. We have to follow stuructre to read /write the data if we using those blocks.
      For more queries connect on Instagram.

    • @skysrivat
      @skysrivat 7 месяцев назад +1

      @@zackk_54544 :I went through the manual and found that the format is as mentioned by you 🙂 Thank you.

  • @fazimalik5214
    @fazimalik5214 8 месяцев назад +1

    Quite informative video

    • @zackk_54544
      @zackk_54544  8 месяцев назад +1

      Thank you for sharing feedback Mr. Malik. Do share your ideas as well, on which you want informative videos.

    • @fazimalik5214
      @fazimalik5214 8 месяцев назад +1

      @@zackk_54544 well i would like to request you to make a video on a motion control as well.

    • @zackk_54544
      @zackk_54544  8 месяцев назад

      @@fazimalik5214 Noted, will share the video on topic soon for sure.

    • @zackk_54544
      @zackk_54544  8 месяцев назад

      @@fazimalik5214 You can also share more specific details regarding your application if you want. Also join the instagram handle as well.

  • @zackk_54544
    @zackk_54544  Год назад

    Is your mind running like a Horse? Don't worry
    Read the Chapter-23
    Master your Emotions.
    amzn.to/48JRn4m

  • @lafatraandrianina1849
    @lafatraandrianina1849 8 месяцев назад +1

    I'm new to the world of plc and I have a few questions in reference to the video which by the way is very good. why do we use the DPRD_DAT and DPWD_DAT blocks instead of the SINASPEED block, what is the difference? and are all these variables in the plc data types all really necessary to put? THANK YOUU🤍

    • @zackk_54544
      @zackk_54544  8 месяцев назад +1

      Hello Friend, I have not used that SINASPEED block, but as per the block description mentioned in help section I guess we can use it instead of using DPRD_DAT & DPWR_DAT blocks. Main difference is only standard Telegram 1 can be used with SINASPEED. Also, No need to mention all variables in data types but make sure you use the right bit to turn on as per the bit addresses. You can check the help section of the SINASPEED block. Variables are necessary to be defined in the data types If you use DPRD_DAT, DPWRDAT.

    • @zackk_54544
      @zackk_54544  8 месяцев назад +1

      If your application does not required much functions go for the SINASPEED and share your feedback.
      For more queries you can join the Instagram handle.
      Thank you