    The FULL Video How to size Ductwork
    • How to Size Ductwork?
    The full video is about 30 minutes long packed full of answers to all your questions on sizing ductwork.
    MIDWEST Aviation Snip - Right Cut Upright Tin Cutting Shears
    amzn.to/3y9kjSv
    Straight Cut Aviation Snips
    amzn.to/3RoNAiT
    Testo Digital Pocket Vane Anemometer
    amzn.to/3KtMcda
    Ductulator
    amzn.to/3AunFjf

Комментарии • 67

  • @pipi7731
    @pipi7731 Месяц назад +1

    I use an attachment to the drill that cuts metal. About 8 to 10 bucks when I bought it. Two, I use rivets. Simply drill a small hole, add the rivet then pop it. I would round the holes where that filter goes in too. Those rivets make it a lot more sturdy and are very inexpensive. The rivter was about 15 bucks.

  • @ethanberdejacortez4845
    @ethanberdejacortez4845 10 месяцев назад +2

    fresh out of school and still have a lot of questions, but slowly everything is clicking into place, Thank you Tad!

  • @JC-sc9rx
    @JC-sc9rx 9 месяцев назад +2

    undersized return can affect refrigerant pressure. Another thing I learned. Really cool. No pun intended..

    • @TaddyDigest
      @TaddyDigest  9 месяцев назад

      Very cool brother you're right

  • @Christ62395
    @Christ62395 3 месяца назад +1

    Is this Chattanooga?! That’s where I’m from and I’m in my first year of HVAC love your videos, they help a lot!

    • @TaddyDigest
      @TaddyDigest  3 месяца назад

      I'm in tennessee about four hours of Chattanooga

  • @darianmoore
    @darianmoore 5 месяцев назад +1

    I have a problem in heating mode where the flame is rolling out due to no having enough airflow

  • @shilobloch3828
    @shilobloch3828 10 месяцев назад +3

    What should you do in case of a gas water heater next to the furnace? Can you split the existing return ductwork and tie it to the other side of the furnace? Will it increase airflow?

    • @micantinaradiola1enmusicap286
      @micantinaradiola1enmusicap286 7 месяцев назад

      I also have a hot water heater next to my furnace, like in one of the questions before. Can I split the existing duct return and tie it to the other side of the furnace. Will this work? Will air flow increase?

  • @jaysheat631
    @jaysheat631 Год назад +1

    definitely recommend turbo sheers ...save so much time

    • @TaddyDigest
      @TaddyDigest  Год назад +1

      I have a pair they are amazing
      Attach right to my drill

    • @jaysheat631
      @jaysheat631 Год назад +2

      @@TaddyDigest there a must have for this industry

  • @cumberlandcountydemacratic7951
    @cumberlandcountydemacratic7951 3 месяца назад +1

    16 INCH ROUND IS GOOD FOR 1400 CFM, I HAVE THE SAME SENERIO. I REALIZE MORE RETURN IS BETTER BUT, DO YOU COUNT THE SQUARE INCH OF THE RETURN VENTS OF THE DUCT SIZE OR BOTH. EXAMPLE, ALL MY RETURN VENT ARE CLEARLY MORE THAN REQUIRED FOR 1400, BUT, MY RETURN DUCT JUST BEFORE MY 14OO CFM RETURN PLENUM IS A LITTLE

  • @raultorres9231
    @raultorres9231 12 дней назад +1

    Wouldn't this cause suction pressure and head pressure to rise since your adding all that heat from the garage into the system?

    • @TaddyDigest
      @TaddyDigest  11 дней назад

      Well, they are insulating the garage and turning it into a room, so it's going to be conditioned

  • @mustangmike6421
    @mustangmike6421 4 месяца назад +1

    Use a muti tool with carbon blade works good keep the blade at an angle.

  • @jaysheat631
    @jaysheat631 Год назад +9

    imo this was a bad idea...ur taking to much return air from that basement area and not the living area...u should have tied the return into the living space some how..u can never have to much return but u want it from the space ur conditioning

  • @elijahdarby3998
    @elijahdarby3998 Год назад +1

    For a 3.5 ton unit shouldn't you have the unit operating at 400 cfm per ton on the furnace control board?

  • @Almtyhalfbreed
    @Almtyhalfbreed 9 месяцев назад +1

    Can the system ice up with too much return? I've seen two returns on a 2.5 ton 16 and 14 flex on it.

    • @TaddyDigest
      @TaddyDigest  9 месяцев назад

      Not enough return will cause it to freeze up

  • @nickgantaifis4327
    @nickgantaifis4327 4 месяца назад +1

    Where can I purchase the angles used for the air filter rack installation?

    • @TaddyDigest
      @TaddyDigest  4 месяца назад +1

      distributor/supply house or online

  • @Ryan-RM
    @Ryan-RM 2 месяца назад +2

    Is it ok to install a return in a garage? Isn’t there a chance for it to pull in carbon monoxide? Or is that considered a basement with a walkout garage looking door? Thank you Tad

    • @TaddyDigest
      @TaddyDigest  2 месяца назад

      it's never ok to install a return in a garage
      unless the house it being remodeled and the garage will be a room instead

  • @mr.boniato6402
    @mr.boniato6402 6 месяцев назад +1

    If my furnace has a 5 inch, Merv 11 filter, do I need to add air filter on 20"x24x1" return vent?

    • @TaddyDigest
      @TaddyDigest  6 месяцев назад

      not sure
      I do not know what size your ductwork or your unit is

    • @mr.boniato6402
      @mr.boniato6402 6 месяцев назад

      @@TaddyDigest they are about 18-20 inch in diameter

  • @jaysheat631
    @jaysheat631 Год назад +2

    id just put a filter base on the side...quick and done

  • @floyddavis263
    @floyddavis263 Год назад +1

    Just to let you know is Actually 500 CFM’s times two for that 20 x 25 because theres 2 CFM for every one square inch of filter space…so you really only need 200 hundred more cfm

    • @floyddavis263
      @floyddavis263 Год назад +1

      Maybe 3 tops👍

    • @TaddyDigest
      @TaddyDigest  Год назад

      That is absolutely correct

    • @floyddavis263
      @floyddavis263 Год назад

      Never mind you said 700 sq in, I didn’t catch that part 🙏🏽

  • @wildman4642
    @wildman4642 9 месяцев назад +2

    I've got a crazy question. What happens if a kid pulls the filter and sticks their hand in the running fan?

  • @EugeneGatlin
    @EugeneGatlin 4 месяца назад +1

    my furnace doesn't have a return, just open air then filter. do I need a return?

    • @TaddyDigest
      @TaddyDigest  4 месяца назад

      Having a return centrally located in the house will give you better comfort and efficiency for the equipment.

  • @thecurious6721
    @thecurious6721 Год назад +3

    Hey Teddy. No offense, but I cant believe my eyes that you posted it 😂. 1) Fire the guy, who put the screw towards the filter rack. He couldnt put the filter himself, how could the customer slide it in? 😉 2) Is it allowed in your state to put the return in the garage? (Risk of sucking car exhaust gases) 3) wont there be a negative pressure in the garage and positive pressure in the house?

    • @TaddyDigest
      @TaddyDigest  Год назад +1

      They don't park cars in it
      I love my James He is awesome
      Thanks for looking out for me
      There is one supply vent in there

    • @thecurious6721
      @thecurious6721 Год назад +1

      @@TaddyDigestthanks for the clarification 😁👍

    • @Balticblue93
      @Balticblue93 Год назад

      That would never pass any code or inspection, especially when they go to sell the house. Hot ass air from the garage being used for return air regardless, if there park in there. That is what a hack does and an inspector would have a heart attack. I told you I would be around more. This is the kind of crap I expect from a hack of a DIYer. I hope nobody ever follows your advice or they will be in some trouble some day. Garages have far more than just exhaust fumes. All returns must come from inside the conditioned space when the air handler is installed in a garage or building that isn't livable space. There is no way you are EPA 608 or NATE certified. I bet you don't even have business liability insurance. Garbage work and can't even follow simple code and rules.

    • @TaddyDigest
      @TaddyDigest  Год назад +1

      I'm glad you're around
      Keep reading those books buddy
      Sometimes you gotta do what you gotta do for the unit to work and for the customer to have heat and air.
      But I guess you wouldn't know am I right to assume?
      Let me know thanks for watching

    • @TaddyDigest
      @TaddyDigest  Год назад

      Absolutely you're welcome my friend and thank you for looking out for me again

  • @builditwell
    @builditwell День назад +1

    As a licensed general contractor, I totally object to this practice, and any competent building inspector flag this as an egregious code violation. A garage is NOT a good place for a cold air return. It will positive pressurize the house at a large energy penalty unless there is a jumper duct from the house to the garage or there is an appropriate amount of supply ductwork conditioning the space in the garage, which in this case would be far too much for the space. Either way, they are creating unhealthy indoor air. For fire separation and safety, GARAGES SHOULD BE TOTALLY SEPARATED AIRSPACES FROM HOUSES, ESPECIALLY IF THEY HAVE CARS PARKED IN THEM. Read up on the ICC rules for garage construction if you doubt this. Far too often, HVAC work is about fixing something horrible by doing something bad. I am a general contractor tired of the abysmal standards of HVAC industry. Just because the air handler blows harder with this quick fix does NOT make the overall system more efficient, and it is unhealthy to mix garage and indoor air. Sometimes, partial knowledge is worse than complete ignorance.

    • @TaddyDigest
      @TaddyDigest  15 часов назад

      I agree that's why in this video I explain that this is not being used as a garage anymore.
      Homeowner was remodeling and removing garage door and closing it in to make it a conditioned room.
      Thank You for sharing this knowledge

  • @EbanQHanna
    @EbanQHanna 10 месяцев назад +1

    Hot water heater??? 🙂

  • @joshlevy9462
    @joshlevy9462 Год назад +1

    Great idea in theory but your not supposed to put a return in garages because of automobile combustion gases could enter house which means s a extremely dangerous hazard. Where I am the would be a code violation but more importantly the potential hazard is more of a concern.

    • @TaddyDigest
      @TaddyDigest  Год назад +3

      You're right
      In this particular instance
      The customer is closing in the garage and using it as a room

    • @joshlevy9462
      @joshlevy9462 Год назад +2

      @@TaddyDigest I’ve watched enough of your video to know you do things correctly and to a high standard so I was pretty sure you weren’t doing anything unsafe but not all that watch know these things and it could be an issue if someone does that without being well informed.

  • @firebird14420
    @firebird14420 5 месяцев назад +2

    You still available for questions??

    • @TaddyDigest
      @TaddyDigest  5 месяцев назад +1

      Always

    • @firebird14420
      @firebird14420 5 месяцев назад +1

      @@TaddyDigest I know this would help supply and supply is my issue some but mostly return is my issue. Can I use this method to connect it to a drop down coming from the existing duct run?

    • @firebird14420
      @firebird14420 5 месяцев назад +1

      @@TaddyDigest I have a 6×20 return doing the whole house on a 3 ton 1200 CFM house return is horrible.

    • @firebird14420
      @firebird14420 5 месяцев назад +1

      @@TaddyDigest The whole return duct run is 28 ft with 5 return vents that go through floor joist/forced air..

    • @TaddyDigest
      @TaddyDigest  5 месяцев назад +1

      Yeah you should be able to use this method