  • @nitulboro7392
    @nitulboro7392 2 года назад +2

    You are giving concentration at the soil setteling but look at your column stirups how it will be given laping

    • @Acelifyking
      @Acelifyking 9 месяцев назад +1

      Thought of same too
      It’s too small

  • @snehal50samarpit
    @snehal50samarpit 2 года назад

    Agar foundation pit me water pond bana kar usme crusher dust daala jaye to automatic compaction hoga?

  • @SUBHAYAN1986
    @SUBHAYAN1986 4 года назад +3

    I have backfilled with soil and then plinthfilled for about 2.5 feet with oily sand which is one kind of industrial waste. Now it is not absorbing any water and remains as it is even after 4 days of watering. What should I do now?

    • @SimpleConstructionzz
      @SimpleConstructionzz  4 года назад

      oily sand means?

    • @SUBHAYAN1986
      @SUBHAYAN1986 4 года назад

      Means the sand absorbed something oily like mobile and becomes black in colour and smelling like kerosene!

    • @SimpleConstructionzz
      @SimpleConstructionzz  4 года назад

      @@SUBHAYAN1986 name of the structure pls

    • @SUBHAYAN1986
      @SUBHAYAN1986 4 года назад +1

      It's a 3 storied residential building.

  • @surajwaghmode7286
    @surajwaghmode7286 4 года назад +2

    Nice Work

  • @nabinrawat2991
    @nabinrawat2991 4 года назад +1

    Underground water tank is being built inside ground floor room of already built old house by digging its floor again. The worker dug almost near to the edges of room. Now after builiding tank while backfilling when water is being put for compaction of every 1 feet the stones and soils below plinth beam are falling due to small area and the water what shoulf be done in this case? Is it ok to compact and back fill by using less water?

  • @shubham_3699
    @shubham_3699 3 года назад +1

    01. Khet ki mitti / 02. River ki mitti / 03. Stone crasher ki mitti ???? inme se bhraan ke liye kya shai rahta hai ????

  • @RaoHimanshu01
    @RaoHimanshu01 Год назад

    Beam p machine ka load de rhe ho … ye shi h?

  • @vijayakumaranaranghat
    @vijayakumaranaranghat 2 года назад

    Will the use of this machine damage the foundation walls since it will run over the foundation,?

  • @n.unnikrishnannair8885
    @n.unnikrishnannair8885 Год назад +1

    Wrong method. Filling should be done in layer by layer without moving Hitachi over basement.

  • @milan731993
    @milan731993 3 года назад +1

    This is sooo wrong....
    When the water dries up , the soil 100% goes down .. now you have to waight for natural satteling of soil ...

    • @SimpleConstructionzz
      @SimpleConstructionzz  3 года назад

      thats not a problem
      after drying pcc and concreting should be done.100% goes down.

  • @bhavishramdharry120
    @bhavishramdharry120 6 лет назад +1

    why is he watering the soil?

    • @SimpleConstructionzz
      @SimpleConstructionzz  5 лет назад +1

      For proper mixing and compaction

    • @hemanttutor6910
      @hemanttutor6910 5 лет назад +1

      @@SimpleConstructionzz i have filled my foundation with building waste. Watered it during morning and evening. When rains came it settled nicely. Didn't need such complicated ideas

    • @SimpleConstructionzz
      @SimpleConstructionzz  3 года назад

      @Hemant Hitech building waste is not good for filling.red soil and clay soil is good for filling.right way of consolidation is mixing water by soil with a height of 20cm

    • @sreejiths8641
      @sreejiths8641 2 года назад +1

      @@hemanttutor6910 This is the proper and correct method to be used.While filling the earth it needs to be either vibrated/watered for proper compaction. Also if we are using this method there will not be any chance of gaps or holes. In future the chance to damage floor concrete is also less.

    • @SimpleConstructionzz
      @SimpleConstructionzz  2 года назад

      exactly

  • @russmus8708
    @russmus8708 5 лет назад +2

    haha … its overdone

    • @SimpleConstructionzz
      @SimpleConstructionzz  3 года назад

      No,this makes proper consolidation and compaction inside foundation

  • @badnewss99
    @badnewss99 5 лет назад

    Wtf is this no skills