Polarity Test of 3 Phase Induction Motor | Correct Identification of Motor Terminal ( Part-1)

Поделиться
HTML-код
  • Опубликовано: 16 окт 2024
  • Polarity test of 3Phase Induction motor is very essential if their is interchange of terminal polarity. There is various methods for polarity test, but in part1, we try to explore a method of polarity test using voltage test method.
    Also watch Part2 of thos video for Polarity test using series test method.
    The topic is related to:
    Polarity test results
    3 phase polarity test
    Motor terminal identification
    how identify motor 6 lead u1,u2 v1 v2 w1 w2
    3 phase motor polarity test
    How to connect three-phase AC motors
    Like and subscribe for more informative video.
    इस तरह के नये और informative विडियो के लिए like और subscribe कर दो|
    Email me at: electricaldesifunda@gmail.com
    #electricaldesifunda
    @Electrical Desi Funda

Комментарии • 15

  • @cfgman1
    @cfgman1 3 месяца назад +1

    Excellent video sir...this is is a very confusing and misunderstood concept which has been explained very clearly in this video. I dont think any other video has addressed the issue both mathematically and practically. Another video using the DC method would be really appreciated. Well done !

  • @rajkumarlavangare1462
    @rajkumarlavangare1462 Год назад +2

    First time I noticed on you tube correct identification is done by polarity test .
    excellent share

  • @ritikraushan7392
    @ritikraushan7392 5 месяцев назад +1

    Can it affect if motor start rotating due to 230 volt supplied in single phase ,and how to avoid high current drawn by motor due to single phase supply , as resistance of motor is very low in milli ohm .

    • @hemantverma5625
      @hemantverma5625 2 месяца назад

      Auto tfr se voltage kam kar ke test kijiye

  • @rajeshjana1006
    @rajeshjana1006 Год назад +1

    Very good sir

  • @amankumarsingh2200
    @amankumarsingh2200 Год назад +1

    Awesome explanation..... Just loved it😍.....I wish you grow more and more and spread the light of knowledge all aroud the world.... Once again thank you so much.... I can't explain how much I needed the phasor diagram explanation of this test.... 🙏🙏🙏🙏

    • @electricaldesifunda
      @electricaldesifunda  Год назад +2

      Thank you for your lovely comment to motivate us. Keep watching for more technical video and can suggest any topics related to electrical.
      My official email id is: electricaldesifunda@gmail.com

    • @amankumarsingh2200
      @amankumarsingh2200 Год назад

      @@electricaldesifunda Sure🤩 !

  • @fakhrialmayahai6111
    @fakhrialmayahai6111 Год назад

    Regarding with the phasor diagram for your sketch, i had litle confusion on your sketch left side V should be not more than V1 Because the sum of vector is oppesite.
    And the right side on the your sketch V should be more than V1 Because the vector are adding.
    Your method testing should be matching with the transformer polarity check.
    Thanks

  • @khalidmorales3031
    @khalidmorales3031 Год назад

    Kindly make a data or schematic diagram for 30 slot asynchronous stator, 3 phase 50 hz. 440/220 vac, in parallel wye terminal connection. Pitch of the slots. Approximately 12 kva. Brush type 2 pair. T.Y.

  • @shafimehar4506
    @shafimehar4506 Год назад

    Sir 3 set coil identify karneyki baad, koibi coilku 1, koibi coilku 2, koibi coilku 3 maan saktheykya?

  • @seefalislamabfita839
    @seefalislamabfita839 Год назад

    Yes

  • @prasantbioflocsystemdesipo1124

    Megger me kaise test karenge bataiye please

    • @electricaldesifunda
      @electricaldesifunda  Год назад +1

      Megger is used to measure insulation condition of Motor and it is nothing to do with motor polarity test. If you want any technical help then email me at electricaldesifunda@gmail.com