  • @omprakashyadav2055
    @omprakashyadav2055 3 года назад

    आप हमलोगो के लिए इतना मेहनत कर के विडियो बनाते हैं इसके लिए आपको बहुत बहुत धन्यवाद 🙏🏼
    सर अगर मैं आनलाईन चिलर टेक्नीशियन का कोर्स करना चाहता हूं । क्या मैं कर सकता हूं। आपके पास किसी संस्थान के बारे में जानकारी है तो बताए बहुत मेहरबानी होगी 🙏🏼

    • @c4chiller9984
      @c4chiller9984  3 года назад +2

      apko jo bhi knowledge chahiye ..chiller se relative ... ham apke liye jarur full try karke vidio bnayenge bilkul aasan language me .....bas ham yahi chahte hai ki har senior apne junior ki help karta Rahe... thank you 🙏🌡️❄️

    • @omprakashyadav2055
      @omprakashyadav2055 3 года назад

      उत्तम बिचार महाशय 🙏🏼

  • @faizankhan-bo7sl
    @faizankhan-bo7sl 3 года назад +1

    Impressive video bro ..keep it up

  • @manumaurya3362
    @manumaurya3362 2 года назад +1

    Gulf contry me iska job hai kya , kyuki me bokaro steel plant me av tarining pr hu

  • @MrShivraje
    @MrShivraje Год назад

    8 kg supply pressure hain to retrun kitna hain? mere plant main supply pressure 5 kg hain (4 floor but 140 AHU's connected) and return only 2 kg? is it ok? chilled water ka supply aur return temp 6.2 aur 10.3 hain , ye difference increase karu kya?

  • @hengineeringmind9871
    @hengineeringmind9871 2 года назад

    Sir jaise 1 Chiller chalana hai to 2 condenser pump 2 primary pump 2 Secondary pump chalega to koi problem nahina hoga

  • @mdsbayezid2024
    @mdsbayezid2024 Год назад

    thanks bay🥰🥰

  • @manojkumarmoharana9380
    @manojkumarmoharana9380 2 года назад

    Thanks sir

  • @RizwanAli-fu3xe
    @RizwanAli-fu3xe Год назад

    Chilled water line and hot water line ka pressure kitna hona chahiye maximum & minimum jab hamara chiller running condition mai ho

    • @c4chiller9984
      @c4chiller9984  Год назад

      minimum 2.9 kg maixmum.. depend on building hight

  • @kailashka824
    @kailashka824 Год назад

    chiller ka suction /discharge pressure kitna hota hai agar isme R134 gas ho, and chiller ke kis jagah par gauge lagake check kar sakte hai ek video banaye.

    • @c4chiller9984
      @c4chiller9984  Год назад

      suction pressure 30 to 40 psi
      discharge pressure 90 to 150 psi
      chiller me suction valve and discharge valve laga hota hai jaha se ham mallom karte hai

  • @sarfarozansari4330
    @sarfarozansari4330 8 месяцев назад

    Ye to aap primary pump ki baat kr rahe hai na.ex- 10th se water niche aa raha hai to ek he pressure rahega hr k floor me..? Ye confusion hai Thora clear kre
    Aur secondary pump to water ko uper le kr ja raha hai to hr floor me pressure different rahega na..?
    To Kitne ka difference rahega per floor..?

    • @c4chiller9984
      @c4chiller9984  8 месяцев назад

      agar secondry pump neeche laga hai yani ki ground floor pe aor apko water 10th floor tak leke Jana hai ..👉to apko apne primery pump ka pressure 5 k.g. tak set karna hoga dost....tab jaake top floor pe apko 1 kg ke oopar pressure mil sakta hai ...
      qki koi bhi liquid ho wo har 10 meter pe 1 kg kam ho jata hai ...

    • @sarfarozansari4330
      @sarfarozansari4330 8 месяцев назад

      @@c4chiller9984 primary or secondary pump..?

    • @sarfarozansari4330
      @sarfarozansari4330 8 месяцев назад

      Dono pump me yhi hoga...?

    • @c4chiller9984
      @c4chiller9984  8 месяцев назад

      secondary must

    • @sarfarozansari4330
      @sarfarozansari4330 8 месяцев назад

      Phr primary pump ka..?

  • @theckpian1844
    @theckpian1844 Год назад

    Bhai primary pump ka in aur out kisme jata hai aur secondary pump ka in or out kisme jata hai?

    • @c4chiller9984
      @c4chiller9984  Год назад +1

      dost .. primery pump ahu ke outlet se water leke chiller ke inlet me deta hai ...👉 aor secondry pump chiller ke outlet se water leke ahu ke inlet me deta .......👍

  • @JIGYASUMAURYA
    @JIGYASUMAURYA 6 месяцев назад

    Chilld water line ka pressure kyu badhta hai ??

    • @c4chiller9984
      @c4chiller9984  6 месяцев назад

      Kitna badh raha hai aor kab badh raha hai chiller off karne ke Baad ya running me ?

  • @golu61350
    @golu61350 Год назад

    Sir mana ki hamara chiller tarric par laga hai to line pressure kitna hoga

  • @Kingss786
    @Kingss786 2 года назад

    Head pressure kitna hona chaheyi R 22 ka 450 TR and 80 TR head pressure kitna hota hai

  • @srinivas9391
    @srinivas9391 2 года назад

    Sir please explain about decoupler bypass line secondary and primary why it is use 🙏

    • @c4chiller9984
      @c4chiller9984  2 года назад

      okji try karte hai .. apke topic pe 👍

  • @asadkarim2032
    @asadkarim2032 3 года назад

    🙏👍🙏🙏🙏🙏🙏👍👍

  • @mohdadilkhan5228
    @mohdadilkhan5228 Год назад

    bhai VGD or PRV me kiya fhark hota hai aur kaise kaam karta hai ?

    • @c4chiller9984
      @c4chiller9984  Год назад

      PRV ( pre rotation van )
      iska work ye hota hai ki ...chiller ke load ke hisab se gas ke flow ko compressor me inlet karwana ..agar chiller pe load 100 % hai to prv 90% to 100% open honi chaiye aor agar chiller pe load 50 % hai to prv 5% se 10% tak hi open rahegi ...
      VGD ( variable geometry drive )
      ye bhi ek tarah se prv ki tarah hi kaam karta hai ... according to load but 👉 thoda sa difference hai jaise ki ye tab kaam karta hai jab apka chiller shut down ho ya phir surge karta ho ....us time pe VGD close hone lagega aor jo abnormal sound ayega to us sound ko vgd kam karta hai ...aor gas ko revers compressor me aane se rokta hai .....thank you

  • @anupgupta7854
    @anupgupta7854 11 месяцев назад

    Sir kitne hight p 1 kg drop hota hai pressure

    • @c4chiller9984
      @c4chiller9984  11 месяцев назад

      every 10 meter pe 1 kg pressure drop hota hai

  • @mdarman8564
    @mdarman8564 3 года назад

    Nice video sir

    • @c4chiller9984
      @c4chiller9984  3 года назад +1

      bahoot sukriya ji apka 🙏💐

    • @mdarman8564
      @mdarman8564 3 года назад

      Aapka bhi bahot bahot shukriya sir humlog k liye video banane k liye

    • @c4chiller9984
      @c4chiller9984  3 года назад +1

      chiller plant ki troubleshooting kaise hoti hai ..aaj vidio upload ho rahi hai ...aap time nikal ke dekh lijiyega ...sukriya 🙏

    • @mdarman8564
      @mdarman8564 3 года назад

      @@c4chiller9984 ok sir

  • @kadharbasha1091
    @kadharbasha1091 2 года назад

    Bhaijan 800 TR centrifugal chiller kitna KW hota hae bolona.?

    • @c4chiller9984
      @c4chiller9984  2 года назад +1

      2813 kilowatt cooling capacity 800 tr chiller ki hogi 👍

    • @kadharbasha1091
      @kadharbasha1091 2 года назад

      @@c4chiller9984 Bhai ab india or pakistan he. India tho konsa state ?

    • @kadharbasha1091
      @kadharbasha1091 2 года назад

      Bhaijan 800TR centrifugal chiller mae, kitna kg gas rahega approximately bolona ?
      And running gas ka suction pressure, discharge pressure bolona? Kindly request

    • @kadharbasha1091
      @kadharbasha1091 2 года назад

      134a gas ka

  • @rajusagar9343
    @rajusagar9343 3 года назад

    Sir,
    If you have time for making one video related to VRV system then pls make once.
    Its humble request
    Regards

    • @c4chiller9984
      @c4chiller9984  3 года назад

      ji bilkul bana sakte the ...but hamare pass vrv ya vrf system nahi jiski vajah se ham apko practical nahi samjha sakte ..qki practical me jayda samjh me aata hai sabko ...agar aap kahe to ham therotical bata sakte hai ..🙏💐

    • @rajusagar9343
      @rajusagar9343 3 года назад

      @@c4chiller9984 ji bilkul bana dijiye.

    • @c4chiller9984
      @c4chiller9984  3 года назад

      @@rajusagar9343 ok ji ۔۔jaise hi time milega ham jarur bana denge 🙏💐

    • @alshaya8703
      @alshaya8703 Год назад

      Sir chiller ke inlet aur outlet me kitna pressure hota aur o kisme hota example psi

  • @IrfanKhan-un7qb
    @IrfanKhan-un7qb 2 года назад

    Sir ye kg ka range bar m bloen
    Or 2nd baat ki in watter press or out water press ka bolen

    • @c4chiller9984
      @c4chiller9984  2 года назад +1

      Ji 1 kg is equal lagbhag 1 bar ke barabar hi hota hai 1 kg = 0۔98 bar

  • @dilluofficial7
    @dilluofficial7 2 года назад

    Sir ek mujhe bta dijiye pls samajh nhi aa rhi h ki jaise 150 tr ka chiller h hamara to ahu kitne CFM ka hoga ye kaise pta chalega hame

    • @c4chiller9984
      @c4chiller9984  2 года назад

      Ji hamne apko isse pahle wale comments me bataya hai 👷aap check kar sakte hai ....
      Yani ki around same yani ki chiller se 5%decrease karke aap rakh sakte hai .

    • @c4chiller9984
      @c4chiller9984  2 года назад

      Ji aap instagram pe ho to aap aa jaiye ham aor bhi questions ho to apke pass ye id hai 👉 kgufran195

    • @dilluofficial7
      @dilluofficial7 2 года назад

      @@c4chiller9984 link send kijiye isse nhi aa rha

    • @chandpasha2491
      @chandpasha2491 11 месяцев назад

      1tr is equal to 400 CFM so u say 150 tr then 150× 400= 60000 CFM honga

  • @zahidkalim8649
    @zahidkalim8649 2 года назад

    Sir mujhe kuch confusion hai woh yeh ke inlet oultlet , suction discharge , return aur supply isko thoda explain kar den mein iss mein confuse ho jata hoon

    • @c4chiller9984
      @c4chiller9984  2 года назад +2

      Koi baat nahi۔۔۔ham batate hai 😊
      Inlet mean 👉 ahu ya cooling tower se aane wale water ko ham inlet kahte hai
      Outlet mean 👉 condenser ya chiller se jane wale water ko ham outlet kahte hai
      Suction 👉 jab evaporater se hamari gas compresser me jati hai to ham use suction kahte hai ۔۔
      Discharge 👉 jab gas compresser se condenser me jaati hai to ham use discharge kahte hai
      Supply 👉 chiller se jo water ahu ko jata hai use ham supply water kahte hai ۔
      Return 👉 aor ahu se water chiller me ata hai use return kahte hai ۔۔
      I hope aapko samjh me aa gaya hoga sukriya ji apka ،💐🙏

    • @zahidkalim8649
      @zahidkalim8649 2 года назад

      @@c4chiller9984
      Thanks sir
      You so sweet❤️

    • @mdnaushad759
      @mdnaushad759 2 года назад

      Sir Really You are great & god bless you forever

  • @Azaz-je5vk
    @Azaz-je5vk 3 года назад +1

    HVAC helper me job lagwa dijiye sir bahut meharbani hogi

    • @c4chiller9984
      @c4chiller9984  3 года назад

      👉9810133796 in nombers pe baat karlo .agar vacancy hogi to ho jayega ... all the best
      👉.9971474873
      .👉9999711138

    • @Azaz-je5vk
      @Azaz-je5vk 3 года назад

      Sir aap ka name

  • @Cricketemoment
    @Cricketemoment Год назад

    Sir chilled water supply and return pressure kitna bar hona chahiye ek standard ke hisaab se

    • @c4chiller9984
      @c4chiller9984  Год назад

      2.9 baar

    • @Cricketemoment
      @Cricketemoment Год назад

      @@c4chiller9984 sir return or supply dono mai 2.9 bar hoga kya

    • @c4chiller9984
      @c4chiller9984  Год назад +1

      ye standard hai ...baki agar ahu ki hight jyada hai to ... pressure bhi jyada rahega .agar pump ground floor pe laga hai to ...inlet 3.5 baar
      and outlet 3.1 ho sakta hai ...ye chiller ka inlet aor out let hoga

    • @Cricketemoment
      @Cricketemoment Год назад

      @@c4chiller9984 thank you sir

  • @sureshkumar-fp8bl
    @sureshkumar-fp8bl 3 года назад

    Hallow brother How to calculate pump design highside and low side pressure.

  • @pkspihu1216
    @pkspihu1216 2 года назад

    Kc6 ka tr capacity ke bare me ak video bna dijie sir

  • @alshaya8703
    @alshaya8703 Год назад

    Sir 2.9 kg kg kya hai

    • @c4chiller9984
      @c4chiller9984  Год назад

      primery pump ka pressure hai 2.9 kg yani approx 41 psi

  • @hengineeringmind9871
    @hengineeringmind9871 2 года назад

    Sir ji Ek WhatsApp group banaiye jitna bhi aapko video dekhta hai Agar koi Questions Rah jaye to wah us WhatsApp group me discars kr sake or usko aasani se job mil sake Please sir Bahut mehrawani sir ji aapko please Reply sir ji

    • @c4chiller9984
      @c4chiller9984  2 года назад +1

      Ok ji ham jaldi try karte hai 👍

  • @sankarrama8430
    @sankarrama8430 3 года назад

    Sir hmko bhi hvac water could chiller per kaam kerna hai aur mai diploma holder and 3 year gulf experience hai central ac ka aur mera target hai badi ac ko banane ka mera help karo sir ji

    • @c4chiller9984
      @c4chiller9984  2 года назад

      Sorry for very late reply ... Kya apko job mil gai

    • @sankarrama8430
      @sankarrama8430 2 года назад

      Bhai usi company me job Kar Raha hu

    • @sankarrama8430
      @sankarrama8430 2 года назад

      Aap apna number do Bhai hum apse baat karenge

  • @musabansari691
    @musabansari691 2 года назад

    Aur kuchh deep mein Sher batao
    एचवीसी के बारे जो इंटरव्यू में पूछा जाता हूं

    • @c4chiller9984
      @c4chiller9984  2 года назад

      Ji aap link pe dekh sakte hai ..bahoot si informative and deep vidio hai

  • @khurshidalam9689
    @khurshidalam9689 2 года назад

    2.9 kg ki 2.9 bar?

  • @iktechnicalvideos2772
    @iktechnicalvideos2772 3 года назад

    Bhai water bailancing kaise karte hai is pe banao video plz ya apna number do

  • @rajkumarbourasi5133
    @rajkumarbourasi5133 3 года назад

    Sir please send cerriar chiller ke 750TR water

    • @c4chiller9984
      @c4chiller9984  3 года назад

      Water pressure apko chaiye ..ya chiller ki jaankari ???

  • @Azaz-je5vk
    @Azaz-je5vk 3 года назад

    Aap ka name

  • @Vineetrawat532
    @Vineetrawat532 7 месяцев назад

    Lulu mall hai

    • @c4chiller9984
      @c4chiller9984  7 месяцев назад +1

      nhi dost ...
      ye apne haryana me gurgaon ki site hai 👍

    • @Vineetrawat532
      @Vineetrawat532 7 месяцев назад

      Ase York k chillar LuLu mai bhi hai same site lag rhi thi

    • @c4chiller9984
      @c4chiller9984  7 месяцев назад +1

      kaha ka Lulu mall ?

    • @Vineetrawat532
      @Vineetrawat532 7 месяцев назад

      Lucknow

    • @c4chiller9984
      @c4chiller9984  7 месяцев назад

      ok ....dost 👍

  • @user-ze7vf3qy9l
    @user-ze7vf3qy9l Год назад

    How can i adjust prassor