Napaka informative sir may nakuha akong ideas first time kung hawak na ganitong boiler.madamo gid nga salamat.pero sir question rotary cup atomizer trouble ano dpat kumg gawin salamat
sir salamat sa info ngayon ko lang nakita yang mechanical sequenser ng fire cycle, electronic gamit ko, sa air fuel control westinghouse general purpose controller gamit ko dati, pwede i- program yung air-fuel ratio kailangan lang may oxygen sensor para ma correct ng computer ang air-fuel ratio pag mausok lalo na pag bunkker ang main fuel.
sir add ko lang mas maganda yung bagong electronic fire control gawa ng fire eye or honeywell, pwede ikabit,yung hi pressure and low feed water interlock, para tumigil yung boiler in case of excesses
good day chief sir ask kolang po kung pwede pobang ma i topic about ballasting of sea water ballast/De ballast thank you po sir and god bless sa tanan nga family mo
sir magandang pre ignition fuel ay butane or propane pwede na gasul, also pag malakas ang air supply posibeng mamatay ang pre ignition flame,i calibrate yung air fuel ratio.
Sir Akala ko abnormal na Hindi mag auto stop ang saacke. Normal pala yun? Sana po ma topic naman ang actual na Pag adjust nyo fuel and air ratio. Thanks more videos pa po .
sa ignition at main fuel kaya dalawa, nagsasara sa both fuel solenoid ang signal na galing sa fire cycle controller, sa electronic fire eye or honeywell flame controller, si wilson ito, dating electrical/instrument technician sa subic naval base ng us navy sa olongapo , philippines
Sir good day. Patulong nman po problma kmi sa saacke boiler pag minanual mo nagpafire sya. Pro pag nsa automode na nd na po. After lng ng maintenance nmin. Tpoz nag aalarma ung comb. Air pressure low. Pinalitan na ng snsor pro ganun parin. Maraming salamat sir.
nakaka inspire sir 4years na ako na stop sa pagbabarko as a motorman 2018 salamat at nagvlog ka at natututo talaga ako..
Ang galing mo chief...ty sa vlog mo sir...
Napaka informative sir may nakuha akong ideas first time kung hawak na ganitong boiler.madamo gid nga salamat.pero sir question rotary cup atomizer trouble ano dpat kumg gawin salamat
ayun oh galing mag explain ng idol ko ang bloudown naman idol next tapic stay safe godbless
Thank you sa learnings na shine share niyo sir.
Goodmorning sir.. Sana madami pa kayong actual video na ilalabas lalo na sa mga operation and troubleshooting at maintenance. Mabuhay ka sir.
New subscriber po sir.. salamat additional knowledge..madaling maintindihan Yung paliwanag nyo po..more ideas to share and more power.god bless
Mukhang masaya kasama to si sir sa barko new subscriber here please continue uploading informative video more power
salamat sa bagong knowledge sir
sir very helpful po and very knowledgeable po yung vlog nyu sir chief mabuhay ka sir
sir salamat sa info ngayon ko lang nakita yang mechanical sequenser ng fire cycle, electronic gamit ko, sa air fuel control westinghouse general purpose controller gamit ko dati, pwede i- program yung air-fuel ratio kailangan lang may oxygen sensor para ma correct ng computer ang air-fuel ratio pag mausok lalo na pag bunkker ang main fuel.
Galing sir mag explain. More videos and troubleshooting sir.
Thank you so much chief. Another learning
Tnx for d vdeo sir !npaka direct to d point wala nang pa sikot2 pa at di boring panoorin. Sana Tuloy2 nu lng po pag uupload in d future👍🤜🤛
welcome megs..
thanks
salamat sa share mo sir napaka galing mo magexplain. Da best.
Nice video very knowledgeable.god bless..
More videos chief.dami kami natutunan
Slamt sir.ayos talaga mag explain.
sir add ko lang mas maganda yung bagong electronic fire control gawa ng fire eye or honeywell, pwede ikabit,yung hi pressure and low feed water interlock, para tumigil yung boiler in case of excesses
Thank you sir, additional knowledge
thanks sir
.very informative😇
New Subs po ako Chief, more more video ❤️ marami akong matututunan sa inyo. Soon to be maka akto din.. Godbless
welcome
Can u please put Eng subtitles for this one Chief?
Ayus sir maraming salamat
Thank you sir
Good
good day chief sir ask kolang po kung pwede pobang ma i topic about ballasting of sea water ballast/De ballast thank you po sir and god bless sa tanan nga family mo
Sir baka pwede kayo nag vlog about sa air compressor principle
sir magandang pre ignition fuel ay butane or propane pwede na gasul, also pag malakas ang air supply posibeng mamatay ang pre ignition flame,i calibrate yung air fuel ratio.
Sir Akala ko abnormal na Hindi mag auto stop ang saacke. Normal pala yun? Sana po ma topic naman ang actual na Pag adjust nyo fuel and air ratio. Thanks more videos pa po .
Sir anu purpose ng hydraustatic test at accumulation test ginagawa poba yun before or after the operation? Or during troubleshoot lang po?
astig ka sir mas gets kita kaysa sa prof ko
Good day ser. New subs po ako 👍 . May tanong sana ako ser kung bakit Dalawa yung solenoid valve sa main burner nang Aux. Boiler?
Thanks. 😊
sa ignition at main fuel kaya dalawa, nagsasara sa both fuel solenoid ang signal na galing sa fire cycle controller, sa electronic fire eye or honeywell flame controller, si wilson ito, dating electrical/instrument technician sa subic naval base ng us navy sa olongapo , philippines
Sir good day. Patulong nman po problma kmi sa saacke boiler pag minanual mo nagpafire sya. Pro pag nsa automode na nd na po. After lng ng maintenance nmin. Tpoz nag aalarma ung comb. Air pressure low. Pinalitan na ng snsor pro ganun parin. Maraming salamat sir.
Linisan nu ang tubes bro
Sa amin sir ayaw mag auto comb. Di mag bukas Yung main solenoid
Speak English 😊
Speak English 🙏