Pump power (Topic 3 Module 1) calculation || Math for WWTP

Поделиться
HTML-код
  • Опубликовано: 18 ноя 2024

Комментарии • 22

  • @ghanchiidrish7934
    @ghanchiidrish7934 2 года назад

    very nice..

  • @sahidhossain1631
    @sahidhossain1631 Год назад

    ❤❤❤❤❤❤

  • @souravkumar2522
    @souravkumar2522 4 года назад

    Nice explanation mam ...plz upload more video

  • @krishnakumar-hj5fv
    @krishnakumar-hj5fv 5 лет назад +1

    Great video.... Please also clear NPSHR, & NPSHA concept in upcoming video... Please

    • @MeenuJainLalitpur
      @MeenuJainLalitpur  5 лет назад +1

      Sure these will be the part of the next module. And thanks for supporting my channel on patreon.com.

  • @rameshsankhat9334
    @rameshsankhat9334 4 года назад +3

    Efficiency eq. is
    n=(Q×H×G׶)/power(P)
    So
    Power=Q*H*G*¶
    How can possible?
    If the possible to every pump efficiency is 100%.

  • @gunasekhar7397
    @gunasekhar7397 4 года назад +1

    Madam, this head need to calculate with valves and friction factor for head loss.
    If size of pipe more like 250mm and 1000mtr length. Same formula can take

    • @MeenuJainLalitpur
      @MeenuJainLalitpur  4 года назад +1

      For complete head loss, you need to find dynamic + static head loss. You need to find the friction losses at each bend, valve , T , joints( sq V/2g with different C values) and in pipes (from Hazen William equation) also. But dynamic losses are very less in comparison to static losses, for tentative design general practice is to calculate static head and take 5 to 10% margin and design the plant.

    • @gunasekhar7397
      @gunasekhar7397 4 года назад

      Thank you madam.
      You can make one video with head loss problems.

  • @sahilchadha8912
    @sahilchadha8912 3 года назад

    Hello Madam, does the same formula is used to show power in performance curves by softwares like EPrism or SelectorPro?

  • @MDDANISH-gl3rg
    @MDDANISH-gl3rg 4 года назад

    Great mam... May you share book name for design study of water and wastewater plant design

  • @qurantheguidanceforjannah1233
    @qurantheguidanceforjannah1233 5 лет назад

    Thanks

  • @LIFETIMEGOAL77
    @LIFETIMEGOAL77 4 года назад

    Madam please do the chemical calculation videos for wastewater treatment plant

  • @lakshmannadasd4832
    @lakshmannadasd4832 3 года назад

    Sir my question is pump in group floor with 7kg discharge pressure, how much pressure in 30 meters height

  • @vijaysrivatsa3216
    @vijaysrivatsa3216 3 года назад

    How do you assume pump discharge , head and max rated pressure. If the details on the discharge of the pump are unavailable

  • @satyabratanayak1890
    @satyabratanayak1890 3 года назад

    g is not a force, it is gravitational acceleration

  • @ziky3329
    @ziky3329 4 года назад

    Thank you beautiful 😊

  • @vijayshankarpandey2063
    @vijayshankarpandey2063 2 года назад

    Water horse power 3.48 hp.
    Break horse power 5.35 hp

  • @LIFETIMEGOAL77
    @LIFETIMEGOAL77 4 года назад +1

    Please send me pdf link madam

  • @DharmendraPatel-gc4wi
    @DharmendraPatel-gc4wi 4 года назад

    34.1327hp mam