sir I am very impressed with you .and I am doing work in Bahrain. and before came to Bahrain I worked ambani hospital Mumbai andheri West and infinity mall malad West .but I have never find like that problem in chiller unit now I am upset for this..okay and u r doing good job thank you so much sir G
hi sir . i am already working of air conditon.but sir i want that u make a video on split type packagge ac . u r doing realy good job sir thank u.......
Namaste sir thanks for this video.sir water chiller controlling ke liye video banaiye please. Sir main jaha kaam karta hu waha pe petra ka chiller use ho rha hai 180 ton ka hai 2 compressor hai or 6 condenser fen hai to sir iske electrical or control ke liye video banaiye please.
Hello Sir, all your videos & explanation etc . awesome technically you are very strong, having deep knowledge. Thanks Sir it's great pleasure to observe you and yours videos Thanks once again Sunil Ghorpade , Mumbai
Hi Girish, do you have any video that explain function of heat exchanger and how does it work with Boiler and Chiller .. if so kindly share it so myself and other can get more information about it cheers
Sir ek query or hai Plz Plz clear kur dijiye sir yey approach temp kya hota hai condenser ya Evaporator ka isko kaisay measure kurtein hain Plz batein sir
Very nice but sir ek query hai yey refrigerant condenser say hokay 43 degree say hokay sidha 4 degree mein kaisay pahuch jata hai Plz batein itna thunda kaisay hojata hai
aur sir,koi bhi refrigerator (freeze)mai defreezer side mai kitna digree centigrade ya Farenhite ka temperature ka cooling aayega toh best temperature mana jata hai aur freezer mai sir
Hlo sir I have an question, As per your explanation temperature is decrease in condenser that's ok but when will you see ph and Ts diagram of refrigeration system you will find temperature and pressure constant ( no change) at the condensation process. Why???, Plz explain I have quite confusion about this, plzz
Sir carrier ka chiller Hai jisme semi hermetic four compresser laga Hai jisko start karne par kabhi ek ghanta par ya kabhi five hour ke bad bhi low sucssion superheat ka code Batata Hai to iska Kiya Kiya problem ho sakta Hai sir please messagee me urgently I am in saudia
Respected sir, What are safety of chiller plant? Plz upload video if video already uploaded then share the link of video.... Regards.. Raju Sagar from Agra
sir,superheat ka matlab kisi bhi liquid ka boiling point tempereture se zyada temperature ka raita hai temprature magar sir expansion device se paar ho kar jane par toh ush liquid ka temperature or pressure kaam ho jata hai na sir pir us liquid me kaise superheat vapoure reheta hai sir
ac main expansion device ke baad refrigerant ka boiling point 4 to 5 degree Celsius ho jata hai. room ka temperature 24 to 25 degree Celsius hota hai. room ka temperature refrigerant ke temperature se jada hota hai issliye room ki garmi se evaporator ka refrigerant ka temperature boiling point yaane 4 to 5 degree celsius se jada ho jata hai aur ussi ko super heating kehte hai.
Agar evaporator main refrigerant superheat na ho tho heat exchanger vo kaam karta hai. Heat exchanger basically refrigeration system ka net refrigeration effect badhane ka kaam karta hai. Refrigerator ka NRE 50% ya uss se bhi kam hota hai Suction liquid heat exchanger Uss NRE ko improve karne ka kaam karta hai
सर मै एक फ्रिज A.C. मकैनिक हूँ और मैं आपसे ये पूछना चाहता हूँ कि जब हम A.C. के लिऐ मार्केट से गैस लेने जाते हैं तो ऊस सिलैडर मैं लिकविड गैस के साथ खाली परैसर भी आ जाता है तो हम जब गैस डालते हैं तो ऊस समय सिलैडर को ऊलटा कर देते हैं और धिरे धिरे गैस को फिल करते है तो ईस कनडिशन में सिलैडर को लटका करना कया सही है
SIR... me avi (delhi metro rail corporation) dmrc ka preparation kar raha hu jisme mera trade mra.c (refrigeration and air-conditioning)he jisme dmrc me exam me 75/120 questions refrigeration se hota he ..... mujhe sir aap bataye ki me kis tarah se exam ki preparing karu plz sir aap meri help kar dijiye..... plz reply
Mr. Arvind app exams ke liye Refrigeration and Air conditioning Assignment test by G.S. Sethi Asian Publication purchase kar sakte hai uss ki price kuch 170 Rs ke karib hai uss main kafi sare objective aur subjective question answer hai jo aap ki exams ke liye bahut helpful honge. Agar kuch bhi doubt hai tho aap comment box main puch sakte ho. All the best for your exams.
aur sir,aircondition room ma greel temperature kitna hona chahiye sir,hum log bhi kaam karte hai sir ac ka sir grill temperature 12 se 15 hona chahiye na kita hona chaiye sir exactly sir
Yes Air conditioner ka Grill temperature 12 se 15 degree Celsius hona chahiye. Grill Temperature ko supply air temperature bhi khehate hai. Room temperature ya return air temperature 24 degree celsius hona chahiye.
Dew to Sea level refrigerant is higher than lower or lower than higher? Related this question like the super heat. I don't know This questions the right answer I asking you.give answer please somebody was asked me this question in the interview.
hello sir Gopal mera ke problem hay 1 ice cande machine hay uska -9 ara hay ham ko -20 hona hay compression no kcj 450lal hay gas 404 hay solutions please
Sir maine RUclips par aap ke jaisa kisi ko nahi dekha .cool mind ke sath basic to advanced tak batate hain
Sir hamne aapka Sara video kodekha bahut hi mahtwpurn jankari Mila Hain.
Girish sir your explaination method is very good. This video solve the problem of superheating in my system.
Its my pleasure
thanks sir . ma abhi hvac ka student hu or sir mujhe aap ki video se bahut help milti hai
sir I am very impressed with you .and I am doing work in Bahrain. and before came to Bahrain I worked ambani hospital Mumbai andheri West and infinity mall malad West .but I have never find like that problem in chiller unit now I am upset for this..okay
and u r doing good job
thank you so much sir G
Welcome Sir
apka btane ka triqa bahot Achcha h
Thanks
Amaizing sir... how such a given the example for understand super heating.. really i hats off you sir.
Sir apka expiation bahot acha rehta Sir☺☺
बहुत बढ़िया सर जी
Thanks
very good Explain Thanks sir ji
Most welcome
Girish shinde sir very nice video. please or b achi achi informative videos upload kia karein. Thanks Sir
Welcome
hi sir . i am already working of air conditon.but sir i want that u make a video on split type packagge ac . u r doing realy good job sir thank u.......
Thank u very much boss. U clearly explained ...about super heat ..
welcome
Namaste sir thanks for this video.sir water chiller controlling ke liye video banaiye please. Sir main jaha kaam karta hu waha pe petra ka chiller use ho rha hai 180 ton ka hai 2 compressor hai or 6 condenser fen hai to sir iske electrical or control ke liye video banaiye please.
mashAllah sir ap ke videos dekkar bhat express milta hai ap pls ( P S C ) waiting ke upload karye pls
ok Sir
Nice present
Thanks
Sir aap ki channel I like v much
Nice explanation 👍
Hello Sir,
all your videos & explanation etc . awesome
technically you are very strong, having deep knowledge.
Thanks Sir
it's great pleasure to observe you and yours videos
Thanks once again
Sunil Ghorpade , Mumbai
I am also lurning ac repairing your videos was very help full for me waiting for next video
Cleared my doubt. Thanks a ton..!!
Nice and plz make a video same like superheat (subcooling)
Hi Girish, do you have any video that explain function of heat exchanger and how does it work with Boiler and Chiller .. if so kindly share it so myself and other can get more information about it cheers
Sir thank you for knowledge.
Sir... iske bare me thoda aur btaiye n....jaise sir yadi ye khrab ho jaye to kya problem create krega etc.
Sirji chiller comp.running me pumping ku chod deta hai or kya karan hai pls, reply de.
Very nice sir ❤❤❤
Thanks and welcome
Sir ek query or hai Plz Plz clear kur dijiye sir yey approach temp kya hota hai condenser ya Evaporator ka isko kaisay measure kurtein hain Plz batein sir
Split ac me minimum kithne meeter copper pipe lagana chaye?
Agar 3 meeter se. Kam pipe lagathe Tu kya problem athe
Sir aagar suction super heat ka temp negative ho gya toh kya hoga ? pls ans 🙏
Possible but vo vapour form mainn hona chahiye
very good your teaching video thank you so much sir ji
Welcome Sir
Very nice but sir ek query hai yey refrigerant condenser say hokay 43 degree say hokay sidha 4 degree mein kaisay pahuch jata hai Plz batein itna thunda kaisay hojata hai
Pressure kam hone se temperature kam hota hai
Sir two 2 stroke our single actin ya double acting kya hota hai is per video banaiye na sir
Ok
Bluestar screw type chiller suction superheat kitna hona jaruri hai
How much Ideal superheat is in system? As well as Give Details in SI Unit
Sr is there necessary to take suction line tempreature from sensening bulb of expansion vale
Suction superheat aur discharge superheat kya he....plz video banao
sir approach aur delta T ka bhi video banaiye please
Compresor me gas charge karte vakt bottle ko ulta karna padta he or tab gas liquid form me jati he tab compressor ke oil ke sath gas mix nahi hota?
Liquid hamesha liquid line se charge karte hai
Thank you sir for your answer
became a fan of urs.....u r awsm sir
Welcome Sir
hi sir gas charge karne ka time valve se pura oil bar peekra hy kyu ayega gas
Nice 👍 video sir
Keep watching
sir ye calculation capillary tube per bhi aply hota h ya sirf txv pe..aur superheat and subcooling ki range kitni honi chahiye..
super heat 8 se 12 c
sir heat load calculation ka 3 video h ya fir or bhi h??
sir air conditional unit me gas ka psi bhi thik hota hai magar discharge line me ice f.. kew ho jaata hai is ke bare me bataia
aur sir,koi bhi refrigerator (freeze)mai defreezer side mai kitna digree centigrade ya Farenhite ka temperature ka cooling aayega toh best temperature mana jata hai aur freezer mai sir
Refrigerator ke freezer aur deep freezer main -18 degree celsius intna temperature hota hai
Very Nice explained Sir
Thanks
hi sir
pls part winding kiya h or ise kaisa check kiya jatah is k bare m kuch bataye
Hlo sir
I have an question, As per your explanation temperature is decrease in condenser that's ok but when will you see ph and Ts diagram of refrigeration system you will find temperature and pressure constant ( no change) at the condensation process.
Why???, Plz explain I have quite confusion about this, plzz
sir namaskar Satish. sir very good
Thanks Sir
Sir carrier ka chiller Hai jisme semi hermetic four compresser laga Hai jisko start karne par kabhi ek ghanta par ya kabhi five hour ke bad bhi low sucssion superheat ka code Batata Hai to iska Kiya Kiya problem ho sakta Hai sir please messagee me urgently I am in saudia
Respected sir,
What are safety of chiller plant?
Plz upload video if video already uploaded then share the link of video....
Regards..
Raju Sagar from Agra
I haven't upload above safety of chiller yet. But it is nice topic
Sir super heat kue nikalte hai please reply..
bahot khub sir ji
Thanks Sir
Sir apa R-32 gas ka barama bolo na,kyu ke spilt AC-may r-32gas mostly use hotaha..
Super heat high and low or oil level rise why reason plz tell me
dear sir,
mujhe cooling tower ka capacity kese nikhalet h ?
package Ac k compressor m heatar laga howa rha ta hai us k kya kam hai
Girish g super heat and subcooled calculate pe video bnaye r410a refrigent pe
Good morning Sir
Sir r22 r410 r407c r32 ka boiling point kya hoga bataye pls
sir expansion valve ke pahle subculed liquid Hai per expansion valve ke bad uska saturated liquid+ vapour kaise ho Gaya.
Super
sir,superheat ka matlab kisi bhi liquid ka boiling point tempereture se zyada temperature ka raita hai temprature magar sir expansion device se paar ho kar jane par toh ush liquid ka temperature or pressure kaam ho jata hai na sir pir us liquid me kaise superheat vapoure reheta hai sir
ac main expansion device ke baad refrigerant ka boiling point 4 to 5 degree Celsius ho jata hai. room ka temperature 24 to 25 degree Celsius hota hai. room ka temperature refrigerant ke temperature se jada hota hai issliye room ki garmi se evaporator ka refrigerant ka temperature boiling point yaane 4 to 5 degree celsius se jada ho jata hai aur ussi ko super heating kehte hai.
Sir g condenser or evaporator ki apas main calculation kaisey krtey hai
Sir R -600a ke double boiling point kyo hote hi. -31aur -11 degree centigreat please tell
ur videos are very impect full to all learners plz I am requesting to u make one video on HVAC duct work fabrication & design .
ok Sir
Sir.ji frij ka compressor heating Kyun kar rha hai
Post some videos on refrigerant charging or explain the method
Sir you are very great
R 32 or R 410 me bottle compulsory ulta karke gas dalna he tab suction line se liquid nahi jayega?... Uska kya answer he .. plz ans me sir
410a ko liquid line se charge karte hai
Very nice video ...👌
Thanks a lot
What is the approch temperature pls reply
Sir pressure tempreture ka char available kara dijiye na please sir
sir,kisi bhi aircondition system me kitna se kitna tak super heat or subcooling aayaga toh wo achha mana jata hai matlab cooling achha hota hai
Airconditioning main 10 degree Fahrenheit superheating hona chahiye aur 14 to 15 degree Fahrenheit subcooling hona chahiye
aur super heat or subcooling ko effect matlab superheat or subcooling meh kis bajha se aircondition me effect hota hai
sir,yeh question ka bhi ans sir
Nice Video SIR JI
Welcome Sir
sir jab evaporator main superheating ho jati hai to refrigerator main capillary aur suction line Ka heat exchanger kyon use kiya jata hai
Agar evaporator main refrigerant superheat na ho tho heat exchanger vo kaam karta hai. Heat exchanger basically refrigeration system ka net refrigeration effect badhane ka kaam karta hai. Refrigerator ka NRE 50% ya uss se bhi kam hota hai Suction liquid heat exchanger Uss NRE ko improve karne ka kaam karta hai
2tr rotay compressor 60 amps leke over load indication alaram bathara hy maine olp realy dalke bi check kiyatha sem problem. problem kya hy sir
compressor ka ohms check karo
sir what are the different approach to increase the effacy of evaporator.
If superheat is 10degree calcuius so delta T of chilled water is 10 degree Celsius?
Sir super haet Kitna Hona chahiye r22 ka
Screw air cooled chillers mein discharge line se kyun super heat calculate karte hain?. Discharge superheat
सर मै एक फ्रिज A.C. मकैनिक हूँ और मैं आपसे ये पूछना चाहता हूँ कि जब हम A.C. के लिऐ मार्केट से गैस लेने जाते हैं तो ऊस सिलैडर मैं लिकविड गैस के साथ खाली परैसर भी आ जाता है तो हम जब गैस डालते हैं तो ऊस समय सिलैडर को ऊलटा कर देते हैं और धिरे धिरे गैस को फिल करते है तो ईस कनडिशन में सिलैडर को लटका करना कया सही है
nice sir up loads more videos for Waring about vrf vrv
What is the cause of high suction superheat in the carrier chiller model no 30gtn150 please explain in hindi
sir,aircondition k curcuit k bare me bhi educational video banaye plz
Next Video ac wiring ka hai
Sir ap Evaporators ka superheat or saturated temp bataya magar ap condensor ka nhi bataya
Girish sir primary and secondary ke bare me batayie plz.
SIR... me avi (delhi metro rail corporation) dmrc ka preparation kar raha hu jisme mera trade mra.c (refrigeration and air-conditioning)he jisme dmrc me exam me 75/120 questions refrigeration se hota he ..... mujhe sir aap bataye ki me kis tarah se exam ki preparing karu
plz sir aap meri help kar dijiye..... plz reply
Mr. Arvind app exams ke liye Refrigeration and Air conditioning Assignment test by G.S. Sethi Asian Publication purchase kar sakte hai uss ki price kuch 170 Rs ke karib hai uss main kafi sare objective aur subjective question answer hai jo aap ki exams ke liye bahut helpful honge. Agar kuch bhi doubt hai tho aap comment box main puch sakte ho. All the best for your exams.
sir please upload ventillation hvac video
aur sir,aircondition room ma greel temperature kitna hona chahiye sir,hum log bhi kaam karte hai sir ac ka sir grill temperature 12 se 15 hona chahiye na kita hona chaiye sir exactly sir
Yes Air conditioner ka Grill temperature 12 se 15 degree Celsius hona chahiye. Grill Temperature ko supply air temperature bhi khehate hai. Room temperature ya return air temperature 24 degree celsius hona chahiye.
Hello sir carrier k package ac me duct me water sweating a rha hai kya kya problem a sakta hai sir plz answer me
Fresh air damper jada kol dita hoga ya kahi se fresh air Airconditioning room main aarahi he
Dew to Sea level refrigerant is higher than lower or lower than higher?
Related this question like the super heat. I don't know This questions the right answer I asking you.give answer please
somebody was asked me this question in the interview.
sir mujhe saturated liquid line kaise liya samjh nh aaya . pls expalin on real unit .i cannot understand
suction pressuer outdoor ke pass lena hota h
Sir causes of low pressure kya hai
Sir ac systeme gas can ulta karuke daluneka naheto can sida karuke daluneka
hello sir Gopal mera ke problem hay 1 ice cande machine hay uska -9 ara hay ham ko -20 hona hay compression no kcj 450lal hay gas 404 hay solutions please
Brine ki specific gravity check kar ke dekhi kay?
refrigeration system kethana superheat temp hona chahiyi
Sr. heat exchanger ke bare me v kuch jankari de
Ok
Ser hvac ka ton kaise chek kare aur cfm se kaise calculate kare