Lec 01 Basic Concepts Required for Machines I Electrical Machines I Genique education

Поделиться
HTML-код
  • Опубликовано: 8 ноя 2024

Комментарии • 272

  • @proudindian9807
    @proudindian9807 5 лет назад +36

    One of the Best lecture available on youtube for machine, another good lecture available is by Centre for Engineering Studies.
    Thanks Sir for such a great lecture

  • @shahzadhashmi1454
    @shahzadhashmi1454 4 года назад +11

    superb dear .... its perfect Refresher course...
    i am Electrical engineer 14 years in field, truely I wish if i had instructors like you it would have much easier studying engineering courses.

  • @luckytechnical4635
    @luckytechnical4635 5 лет назад +11

    Thanks a lot sir. Plz provide us machine videos lectures continuously..... Your team members are the real hero for poor students.. Keep it sir..

  • @ajitkumarsingh4661
    @ajitkumarsingh4661 4 года назад +1

    Namaskar Sir
    Aapka lecture sunne k bad lgta hai ki
    ak best teacher ki tlash puri ho gyee.

  • @kallolchatterjee7849
    @kallolchatterjee7849 5 лет назад +4

    1.In case of DC circuit there exists only one term power and in case of AC there are two terms (one is the Pavg and other containing the frequency component).The average value of the frequency containing term is 0.So, the useful power is only the constant average value.This average power exists for both AC and DC but in case of AC circuit this value is equal to the real power or active power and this value is equal to the power in DC network.
    2. We calculated the value of average power as cos(phase differnce). So if we donot take the conjugate in the current term real power will not match with the average value term. So to make the value equal of the real power and the average value we should take the conjugate sign..

  • @chaitanyakumar1270
    @chaitanyakumar1270 5 лет назад +10

    One of the best channel on RUclips...

  • @durgaprasadnaredla5832
    @durgaprasadnaredla5832 5 лет назад +15

    Avg power is dc powe bcz there is no time dependency, freq=0...
    Reactive powers is not useful power but it is useful to carry the power from generation to distribution side... required positive sign ..so reactive power need to be positive ..that's way taking positive...I have little bit confusion in complex power . .waiting for next lecture..

  • @syedammad7004
    @syedammad7004 4 года назад +6

    one of the best teacher i have never seen, thank you so much sir, always bless and lov from pakistan

  • @bluekobra9906
    @bluekobra9906 5 лет назад +9

    2SinA*sinB=cos(a-b) -cos(a+b)

  • @9873502528
    @9873502528 5 лет назад +3

    Pavg is DC power as it does not vary with time. but if we talking about instantaneous power then that will be AC power with frequency twice that of Supply.

  • @nikhilnambiar4978
    @nikhilnambiar4978 5 лет назад +4

    P avg is AC when there is phase difference between V and I. When both in same phase, then DC.

  • @nikhilsinha2185
    @nikhilsinha2185 4 года назад +1

    sir ,it is dc power because in ac power half is positive and half is negative .Hence overall power is zero.so given power must be dc in nature.

  • @ketansharma1603
    @ketansharma1603 5 лет назад +8

    Active power is dc power as it has no time varying component.
    The conjugate is taken to get proper sign of active and reactive power. Also if conjugate is not taken then it will be apparent power not complex power.

  • @abhishekkashyap4708
    @abhishekkashyap4708 5 лет назад +1

    Since avg power is not changing with time or phase it is dc power
    Whereas complex power has conjugate because it need to be satisfied with the derivation we performed if we don't take conjugate leading and lagging power doesn't come as it should so to make calculation easy we developed a power as complex which doesn't actually exist but satisfy all equation of power in ac circuits

  • @chatureshdaksh24
    @chatureshdaksh24 5 лет назад +1

    App.power gives= magnitude of total power , Complex power =magnitude with angle (real & reactive power). Avg power=DC power ,power frequency oscilate in time period this part give total power zero ,P avg=vrms irms cos(angle bw V&I )

  • @sharadshrivash323
    @sharadshrivash323 4 года назад +4

    Dc power because independent of time that means constant.

  • @Pawan-g3v9m
    @Pawan-g3v9m 8 месяцев назад

    Nice explaination and helpful information

  • @chiranjitmandal8623
    @chiranjitmandal8623 5 лет назад +2

    Average power is ac when there has phase angle difference between v and i. Dc when same phase.
    Conjucate use to make v and i angle difference .if vi normal multiplying then we get angle addiction which is not required .

  • @vinaykanth-s
    @vinaykanth-s 5 лет назад +1

    Average Power is DC power.
    Conjugate used in Complex power is just a mathematical concept that will allow us to calculate correct values of P,Q & S.

  • @sahumoolchand3101
    @sahumoolchand3101 4 года назад +1

    Sir if it has real magnitude so it is definitely dc power because ac power avg value is always zero and as you told that it is also called active power, but if it is AC power so it must have active and reactive components but you mentioned only active and not reactive power that's mean it is dc power. THANK YOU

  • @aryananup5625
    @aryananup5625 5 лет назад +2

    Aapka teaching style bahut hi Accha hai. All concept aap clear kra diye..thank you sir ♥️♥️♥️

  • @PradeepKumar-vo9fp
    @PradeepKumar-vo9fp 5 лет назад +2

    Apparent power ---- magnitude
    Complex power--- magnitude and direction

  • @alexmustang8177
    @alexmustang8177 5 лет назад

    Our machine man.. 🙏 sir Bht kuch sikha h Aapse...............

  • @85_pankajkumar14
    @85_pankajkumar14 5 лет назад +2

    very nice videos sir ...salute u as a teacher...

  • @abhishekvyas241
    @abhishekvyas241 4 года назад +2

    Best starting of machine ❤️❤️ this is amazing sir ❤️

  • @arvindagrahari6833
    @arvindagrahari6833 5 лет назад +32

    instantaneous power wrong not plus + in b/w avg power and 2nd harmonic component
    instantaneous power= (avg power) - (2nd harmonic component)

    • @Amitkumar-qq8dq
      @Amitkumar-qq8dq 4 года назад

      👌👌👌☺️

    • @metacorb
      @metacorb 4 года назад

      ya true thats why i came to see comments.

  • @soumyabratabanerjee9996
    @soumyabratabanerjee9996 5 лет назад +6

    In case of inductive load the nature of the inductor is current will always lags behind the supply voltage in case of inductor so the phase angle in case of current is negative so it will I at an angle of - phase angle but it will absorb reactive power means reactive power is positive so to satisfy these we have to take the positive sign.In case of capacitive load the current will always lead the supply voltage so the phase angle in current is positive. But in case of reactive power it will deliver the reactive power so according to that it will negative so that we have to take the conjugate sign.

  • @AjeetKumar-op8dm
    @AjeetKumar-op8dm 4 года назад

    Jabardast sir ji

  • @enggstudymaterialeducation4093
    @enggstudymaterialeducation4093 5 лет назад

    1. average power as a constant power and in this power frequency is zero then as dc power (in dc frequency is zero)
    2. to write in standard format of p=vicosk where k=angle between v & i.

    • @twinkle6884
      @twinkle6884 4 года назад

      It's Ac average Power coz power factor ki value h ____
      Jo log ye reason bta rhe h ki Ac ki average value ko zero hota h so it's dc average power to Jaruri nhi ki Ac ka average power zero ho it's depend on powerfactor___😊😊😊
      Jub pure inductive and capacity rhta h tabhi Ac ki avergae value zero hoti h
      Daynemo type wattmeter instrument se hum log power jo measure krte h wo Ac ki average value hi to measure kr rhe h
      So aap log kaise bol skte ho ki har condition me average value Ac ki zero hoti h
      Mujhe jyda knowledge nhi h
      I'm a diploma student
      Sorry kuchh glt ho to
      And average power independent of frequency or angular velocity alys

  • @rituparnapoddar2211
    @rituparnapoddar2211 4 года назад

    You are the best teacher sir

  • @vaikh8450
    @vaikh8450 5 лет назад +8

    Expression of Instantaneous power is wrong "-" will come in place of "+" . Thanks sir

  • @hanumatprasadtiwari906
    @hanumatprasadtiwari906 5 лет назад

    DC power means the power delivered by dc source and the AC power means the power delivered by ACsource.
    Since the AC power contains two values i.e time dependent and time independent.
    To find the overall effect of Instataneous power over a period of time, we find the average value of instataneous power & only the time independent factor comes into play as the time dependent factor vaue is zero.
    So the power is rms value of the AC power

  • @eagleeye7098
    @eagleeye7098 4 года назад

    Avg is sumthing dat we calculate for time varying quantities. Avg of any dc quantity is the quantity itself, so avg for any dc quantity is just meaningless. So Pavg, or P rms is calculated for ac quantities, though these come out to be fixed numbers.
    The reason why we take conjugate is just to get the idea of nature of loads, ( leading, lagging, or UPF), or in broader sense, the nature of reactive power. i.e: by comparing the phase angles of current and voltage waveforms, otherwise if both the angles wud have been conventionally +ve, it wudn't have been possible.

  • @PrinceKumar-hw1rm
    @PrinceKumar-hw1rm 5 лет назад +13

    1. Active power is the average power means it doesn't vary w.r.t time so it is a dc power
    2. As inductor always absorb +Q reactive power but current through it is lagging so if we directly multiply vrms and Irms(having negative sign)then Q will be negative which is not true.
    So it means to find Q in inductor I angle should be positive
    But in nature it is lagging
    So we take conjugate of that lagging current and it becomes +ve.
    This is my explanation to the question asked
    Please correct if I said anything wrong.

    • @GeniqueEducationTeam
      @GeniqueEducationTeam  5 лет назад +4

      Think one more time about average power.

    • @sofyb.varghese5953
      @sofyb.varghese5953 5 лет назад +12

      @@GeniqueEducationTeam DC power doesnt have a concept of phase in it. So that is why Pavg here is AC power. I am just guessing. I am not able to connect further. Please correct me.

    • @GeniqueEducationTeam
      @GeniqueEducationTeam  5 лет назад +11

      @@sofyb.varghese5953 correct

    • @85_pankajkumar14
      @85_pankajkumar14 5 лет назад

      @@GeniqueEducationTeam sir we use * to get max. power factor i.e, towards unity... iam guessing...

  • @sumitpancham4199
    @sumitpancham4199 3 года назад

    Sir in leading and laging concept between two quantities.
    when we take a quantity as reference and rotataes it in anti clockwise direction this quantity (reference) leads by some angel
    But when in same conditions we just choose clock wise direction the same quantity (reference) lags by some other angle
    Are both things right or there are some misconception
    Plaese tell me
    I will be thankful to you 🙏👏

  • @Harsh321cd
    @Harsh321cd 3 года назад +1

    Average power is DC power because it has not any time varying term or frequency.

  • @sredutech8051
    @sredutech8051 5 лет назад +4

    The purpose of conjugate is to assign the sign for reactive power

    • @deeznuts-pf2lv
      @deeznuts-pf2lv 3 года назад +1

      No, conjugate is used to get the difference of phase angles of voltage and current when they are multiplied together to get power. If you directly multiplied them without taking conjugate then their phase angles would add up which would be wrong.

  • @vinayellaboina4056
    @vinayellaboina4056 5 лет назад

    Ac power only.because we don't take avg power in DC.ac power is instantaneously changes.so,to make calculations easy ,we go for avg in ac system

  • @dbengineers5605
    @dbengineers5605 3 года назад

    You are Great sir 🙏. Thank you

  • @naina2557
    @naina2557 4 года назад

    Average power is dc power as it is time independent..
    The conjugate exists because of the fact that current lags voltage by 90degree...

  • @duggusworld3337
    @duggusworld3337 5 лет назад

    U r best teacher ever

  • @deepakdk8190
    @deepakdk8190 2 года назад

    If we don't take the conjucate of "I" when we calculate the loads of inductor and capacitor
    Inductor delivers reactive power and capacitor absorbs reactive power and that's impossible or wrong.

  • @jhankarchoudhary
    @jhankarchoudhary 4 года назад

    best lecture on basics of phasors

  • @simplyengineer7938
    @simplyengineer7938 5 лет назад +17

    P avg = P dc [dc power]
    because... average power of AC is zero it has both positive and negative amplitude of same magnitude. so (+V) + (-V) = 0

    • @Technicalpandit1261
      @Technicalpandit1261 5 лет назад +1

      Wow sir i love you 😘😘😘😍😍😍

    • @twinkle6884
      @twinkle6884 4 года назад +2

      It's Ac average Power coz power factor ki value h ____
      Jaruri nhi ki Ac ka average power zero ho it's depend on powerfactor___😊😊😊
      Jub pure inductive and capacity rhta h tabhi Ac ki avergae value zero hoti h
      Daynemo type wattmeter instrument se hum log power jo measure krte h wo Ac ki average value hi to measure kr rhe h
      So aap log kaise bol skte ho ki har condition me average value Ac ki zero hoti h
      Mujhe jyda knowledge nhi h
      I'm a diploma student
      Sorry kuchh glt ho to

    • @lekhrajjangid8580
      @lekhrajjangid8580 3 года назад

      @@twinkle6884 correct as i know,
      Dc. P=VI
      AC P= VI Cos¤
      Phasor difference is aplicable in AC circuit, For DC circuits, power factor is always 1 so there can not be a phase angle between current and voltage except zero

  • @competitioncurrentaffairsw2128
    @competitioncurrentaffairsw2128 5 лет назад

    Average power is AC power beacuse in formula of Pavg=Vrms*Irms*cosphi , here cosphi is the angle between voltage and current, in DC circuit both current and voltage are same so no cosphi is possible where in AC circuit voltage and current have some angle .

  • @shahzadhashmi1454
    @shahzadhashmi1454 4 года назад

    i think it will be DC power, since AC over a complete period nullify +ve half wave with -ve counter part. plz correct me if i am wrong . thnx in advance

  • @priya03_94
    @priya03_94 Год назад

    Sir if it's a DC ckt, then why there is cosine term in average power equation? Wen there is no frequency at all

  • @shivprasadnaik5632
    @shivprasadnaik5632 5 лет назад

    As , there is no time varying qantity so it is dc power but if we consider the sinosodal function cos then it must ac power

  • @suvrojitmitraRailFan2893
    @suvrojitmitraRailFan2893 5 лет назад +4

    Sir you are really great..all concepts are just on my fingerprints.....plz upload some videos regarding induction motor and synchronous Motor

  • @mohdaqib784
    @mohdaqib784 5 лет назад +3

    Average power is i think ac power bcoz if we go to dc circuit rms value is analogous to dc value

  • @tatabirala8419
    @tatabirala8419 5 лет назад

    Average power is dc power as it is independent of time or average is a word which used for dc case

  • @kaliprasadgouda3848
    @kaliprasadgouda3848 3 года назад

    Best Best Best.............

  • @MohammadAsif-zp8px
    @MohammadAsif-zp8px 5 лет назад

    @genique and there is no power factor in d.c. i.e. DC (power,)=vi always but in ac power flow by VI in r.m.s. *P.F. .....so in order to make it close to VI r.m.s. we needed P.F. correction.........my opinion ..... correct me if I am wrong...

  • @bhanupratapprasad8777
    @bhanupratapprasad8777 4 года назад

    Dc power because cos is multiple of rms values and rms value is dc form of ac signal

  • @sindhinews8218
    @sindhinews8218 5 лет назад

    In complex power conjute of current is taken because it shows the inductive Nature of the load

  • @prabhatmishra5667
    @prabhatmishra5667 4 года назад

    1) It is DC power because DC is average value in a circuit
    2) We take conjugate because Power Travels in same phase as current, if we will not take conjugate then it will give wrong phasor of power wrt Voltage

  • @shubhankakelmani8729
    @shubhankakelmani8729 5 лет назад

    Average power is calculated for both DC and AC. In DC, it's just the constants of voltage and current as there is no sinusoidal. But in AC calculation of average power is slightly different because of fluctuations.

  • @Akashkumar-yc5ny
    @Akashkumar-yc5ny 5 лет назад

    Sir in the first question, this is the Ac power because, in DC not have phase shift .........

  • @PECEI-
    @PECEI- Год назад

    but x3(t) is sine wave. It should be converted to cosine @20:08

  • @souvikbera5845
    @souvikbera5845 5 лет назад

    average power can be dc power because Pavg=Vr*Ir cos(phi) and dc power=VI,in dc the angle between voltage and current is zero so dc power=VIcos0=VI ,similarly if angle between voltage and current becomes zero then we can write Pavg=VIcos0=VI=dc power.

  • @PEC_AnkitTiwari
    @PEC_AnkitTiwari 5 лет назад

    Avg. Power is a dc power.. Because average of a quantity tells about the dc nature of a quantity.

  • @arunpratapsingh5051
    @arunpratapsingh5051 5 лет назад +3

    Sir phasor ka ye concept phli bar pdha hmne ap se fir se humble request h k plz 50% discount provide kr dijiye us time pe sadi thi ghr me isliye afford nhi kar paye plz understand my problems sir

  • @jayateerthajeevanigi6581
    @jayateerthajeevanigi6581 5 лет назад

    Pavg depends on the phase angle...... If PF is zero then it is DC power.. If any phase angle exists there exists non unity PF which gives the active power

  • @gauravgupta270
    @gauravgupta270 5 лет назад

    Your teaching way is very good sir

  • @mohdaqib784
    @mohdaqib784 5 лет назад +1

    Complex power me I conjugate isiliye rahega kynki agar i conjugate nhi hua to cos(thet1+theta2) aaega jo active power se match nhi kar rha Sir please correct if i am wrong

  • @jayakrishna3921
    @jayakrishna3921 5 лет назад

    Sir, Avg power is ac power because we are considering power factor i.e. we are considering phase so i feel avg power is ac.
    pls tell me whether i am correct or wrong

  • @satyasp751
    @satyasp751 3 года назад

    P avarage power is dc power because independent of time

  • @tushargairola4600
    @tushargairola4600 2 года назад

    Sir pavg. Power is dc because in ac avg. Is zero

  • @Hey_debo
    @Hey_debo 5 лет назад +2

    1 ans dc..
    Sir machine kitne dinome khetam hoga..
    2. Ans.. Kiuki power factor is the diference between the angle of current and volume..

  • @Akashkumar-yc5ny
    @Akashkumar-yc5ny 5 лет назад +1

    Respected sir, Complex power me hum conjugate is liye lete hai, because for satisfying the actual power,(it gives both magnitude with phase), but because apparant power not represented in phasor ( apprant power only give magnitude )......... tell me sir Right or wrong......

  • @soumyabratabanerjee9996
    @soumyabratabanerjee9996 5 лет назад

    Sir obviously its ac power because if its not an ac power then why we are representing the average power in forms on phasor format that means its an ac power because in active power expression it will represent vrms irms into cosine of angle between them.

  • @parthahluwalia6018
    @parthahluwalia6018 4 года назад

    Gr8 trick sir

  • @MohammadAsif-zp8px
    @MohammadAsif-zp8px 5 лет назад

    Active power is actually power ......since it is calculated by averaging of inst.ac power......r.m.s. value is dc power equivalents to DC power....

  • @amitsinha0790559
    @amitsinha0790559 5 лет назад

    Awesome sir. Aap mast padate ho. Maaja aata he.

  • @Akashtt-oi7bp
    @Akashtt-oi7bp 4 года назад

    Good

  • @dilipkumar1393
    @dilipkumar1393 2 года назад

    Thankyou sir

  • @ujwal4529
    @ujwal4529 4 года назад +1

    What's the final ans is it D.C or A.C power?

  • @udaymehta8917
    @udaymehta8917 5 лет назад +3

    1, average power is dc power because there it is independent of time
    2, Without conjugate form of complex power like = P-jQ, means alternator deliver Active and Absorb Reactive power, which is not case in real

    • @chandel8823
      @chandel8823 5 лет назад

      If average power. Is ac then its aveagre or area under that sinudoidal ac will be not defined

  • @RAMESHKUMAR-02
    @RAMESHKUMAR-02 5 лет назад +1

    I think, average power may be called as both ac power or dc power

  • @9873502528
    @9873502528 5 лет назад

    and we use conjugate to make angle equal to Pavg angle.

  • @vydhik_devaraj
    @vydhik_devaraj 4 года назад

    Avg. power is DC power because it has no time varying component. And according to Fourier theory any periodic signal can be represented in sinusoidal form along with it's DC component. Here we can assume that the instantaneous power is represented in Fourier series with avg term as DC and another term as harmonic component.

    • @twinkle6884
      @twinkle6884 4 года назад +1

      It's Ac average Power coz power factor ki value h ____
      Jo log ye reason bta rhe h ki Ac ki average value ko zero hota h so it's dc average power to Jaruri nhi ki Ac ka average power zero ho it's depend on powerfactor___😊😊😊
      Jub pure inductive and capacity rhta h tabhi Ac ki avergae value zero hoti h
      Daynemo type wattmeter instrument se hum log power jo measure krte h wo Ac ki average value hi to measure kr rhe h
      So aap log kaise bol skte ho ki har condition me average value Ac ki zero hoti h
      Mujhe jyda knowledge nhi h
      I'm a diploma student
      Sorry kuchh glt ho to
      And average power independent of frequency or angular velocity alys

    • @vydhik_devaraj
      @vydhik_devaraj 4 года назад

      @@twinkle6884 Hi..... What I said was that the instantaneous power is a periodic signal and every periodic signal can be represented in terms of sinusoidal signal(Fourier series) and the Fourier series has constant component along with harmonics... For example if you take a square wave(periodic) which has positive and negative cycles, it can be represented in Fourier series... The Fourier series will have avg. component(time invariant part) along with sine and cosine terms...The loose term used for Avg. Value is DC value... That's why I said it is DC

    • @vydhik_devaraj
      @vydhik_devaraj 4 года назад +1

      @@twinkle6884 Yeah It's not correct to say it as DC... My mistake... It's just AC average power.

    • @twinkle6884
      @twinkle6884 4 года назад

      @@vydhik_devaraj it's okay
      Mi to bus opinion rkhi hu😊😊😊😊
      Jyda janti nhi hu abhi diploma student hu 2nd year

    • @vydhik_devaraj
      @vydhik_devaraj 4 года назад

      @@twinkle6884 accha... Theek hai... 👍😁

  • @udaykant3754
    @udaykant3754 5 лет назад

    P(avg) is always dc power because it is not combination of time varying component and also frequency is absent (f=0Hz)

    • @twinkle6884
      @twinkle6884 4 года назад

      It's Ac average Power coz power factor ki value h ____
      Jaruri nhi ki Ac ka average power zero ho it's depend on powerfactor___😊😊😊
      Jub pure inductive and capacity rhta h tabhi Ac ki avergae value zero hoti h
      Daynemo type wattmeter instrument se hum log power jo measure krte h wo Ac ki average value hi to measure kr rhe h
      So aap log kaise bol skte ho ki har condition me average value Ac ki zero hoti h
      Mujhe jyda knowledge nhi h
      I'm a diploma student
      Sorry kuchh glt ho to
      And most important average power independent of frequency or angular velocity alys

  • @monuprapatiprajapati3155
    @monuprapatiprajapati3155 5 лет назад

    Good teaching

  • @Surajkumar-gp8ux
    @Surajkumar-gp8ux 5 лет назад +1

    P av is ac power as it include phase

  • @gokulrathod46
    @gokulrathod46 4 года назад

    average power is a dc power because in this lecture u said that in instantaneous power Vrms Irms Cos(@1-@2) is not a time variying so it is called average power. that's why Pavg is DC power due to in dc power there is no time variying fields..

    • @GeniqueEducationTeam
      @GeniqueEducationTeam  4 года назад

      Think again it's AC power not DC power. Think again and again you will get the point.

  • @nirmalmahto05
    @nirmalmahto05 5 лет назад

    Thanks sir u r awesome
    Sir please start online live classes from very basic level

  • @NISHANTYADAV-zc1eh
    @NISHANTYADAV-zc1eh 5 лет назад +1

    Sir it will be become ac power

  • @RajKumar-dx7ol
    @RajKumar-dx7ol 5 лет назад

    Canjugate is use mainly sign canvenstion

  • @vikramraj2124
    @vikramraj2124 5 лет назад

    sir i think AC power because in DC frequency is constant so no sine and cos term will come but here it is coming so i think it is ac power

  • @PROMOTE-HUMANITY
    @PROMOTE-HUMANITY 5 лет назад

    avg. power is a dc power because . dc power is constant with respect to time but ac power is change with respect to time

  • @brijeshpaswan7510
    @brijeshpaswan7510 4 года назад

    Average power is same like as DC power because we all know DC is time independent quantity and here cosfi ( power factor) is a time independent

  • @SaurabhSingh-vc6mn
    @SaurabhSingh-vc6mn 3 года назад

    AVG power is DC bcz time independent

  • @rinkuraj9971
    @rinkuraj9971 4 года назад

    Average power is also known as dc power as there is no time factor

  • @bhawanisingh3073
    @bhawanisingh3073 5 лет назад

    One of the good video.. Nice

  • @gugulothmohan870
    @gugulothmohan870 4 года назад

    Nice sir

  • @competitioncurrentaffairsw2128
    @competitioncurrentaffairsw2128 5 лет назад

    Superb lecture.

  • @NEHASINGH-yl3tm
    @NEHASINGH-yl3tm 5 лет назад

    Pavg is AC power..bocz in dc power there is not concept of phase...nd in complex power we take I conjugate bcoz. Inductor consumed reactive power nd in inductor current is lag behind voltage so...we take I conjugate...nd in case of capacitor it delivered reactive power..nd current lead by voltage in capacitor condition...so we take conjugate of I to show that negative...bcoz capacitor deliver reactive power .

    • @arvindkrshah4369
      @arvindkrshah4369 5 лет назад

      Pavg is a DC power.. I'm sure because Pavg of AC power is zero.. avg of sine and cosine function is zero.. I guess

  • @NISHANTYADAV-zc1eh
    @NISHANTYADAV-zc1eh 5 лет назад +1

    In complex power i don't know that why take a conjugate of current

  • @lokeshjangid163
    @lokeshjangid163 5 лет назад

    1. Avg power in AC is Zero or Is DC.
    2. Conjugate represent only for that Generates deliver power not abosrb.

    • @twinkle6884
      @twinkle6884 4 года назад

      In pure inductive and capacity circuit average power in zero

  • @dilipkumar1393
    @dilipkumar1393 5 лет назад +1

    Sir it depend on value of cosx