Microtek sine wave inverter overload problem! lagatar overload weep🔊sond!24×7 1125va inverter repair
HTML-код
- Опубликовано: 29 май 2021
- LED TV repair model ke sath video link👇
• Standby Problem/No.Pow...
New smd inverter MOSFET drive problem video
link👇
• New digital SMD Microt...
luminous inverter full dead repair video link👇
• luminous inverter Shak...
Microtek SMD inverter kit kit problem video link 👇 • Microtek sinewave inve...
motor ka pressure kaise Tej Karen video link👇
• Video
luminous inverter dead problem repairing video link👇
• luminous inverter repa...
LED TV mein universal board kaise install Karen video👇
/ skoi bhiPZKagI2Wk8
induction cooktop E0 problem video link👇
• Enduction cooktop E0 e...
LED TV backlight problem video link👇
• Universal LED TV backl...
LED TV power problem video link👇
• LED TV power problem !...
#kanhaelectronicsgenius
#Microtekinverteroverloadproblem - Авто/Мото
Very Nice explain sir
Good video sir sab samajh me aa gaya k overload kahan se hota hai thank you
Apke samjne ka tarika bahot hi acha hae sar
You are the best teacher in teaching. Thanks Bhai 🙏🙏🙏
Thanks from Nepal 🇳🇵
Guru g please ek video digram ke saath bnao❤
Hum fault create karne ke liye idhar nahi aaye hain😂😂🤣😂🤣😂
Very nice video boht kuch सिखा diya
Good video sir Very usefull video
Very good explanation sir thanks 👍
Good tiching karte hai 👍👌👍👍👌👌👍👍👌👌👌
Super video sir puri usefull video sir h thanks
U welcome
Superb video bhai🎉🙏.
good video.
Namastey sir microtek inverter dg900 overload problem hai thk Krna hai sir
Microtek SS1060 sinewave Overload
Problem ka solve video chahiye SIR
Bhaya Hamara inverter ka machine jo hai wo bar bar current jab Rahta hai bich bich me wo overload show Kar raha hai ,but hum usko direct Kar dete hai but 30 min bad jab phir se jab connect karte hai tab phir se thik ho jata hai phir se agle din dikhata hai kya kare bataye.please say me
Nice video sir 👌
Good videos most welcome 😊
Tq
Super video sir
Very good video sir
Good video sir
Miccrotek 1400 xp model 12v par bhi video banaye on karte hi shop ki MCB down kar deta h jabki mov relay change kar di
Aap str change kijiy
Great
Good❤
Sir microtek pure sine wave kewal ek fan aur doo led bulbs chala raha hai agar dosra fan on karte hai too overload karta hai plz reply
Ha bhai mere sath bhi aisa hi ho ra Microtek ss1065 hai.
Sar humko inverter banana sikhana hai
Aap meri sare video dikhte jaye aap ek din jarur inverter bnana sikh jaoge
Low battery ke sath BP awaaz karna
👌👍👌👍👌
Sar assembly IC ko kaise nikaalte hain kaise lagate hain lagakar bataiye
लॉन्ग कार्ड इनवर्टर में 750 में सारी एल ई डी चालू हो जाना और जोर-जोर से हैमिंग मारना इसका कारण सर जी बतानाआपने जो डायग्राम बताया है उस डायग्राम से सब इनवर्टर सुधर सकते हैं या फकत माइक्रो ट्रैकिंग इसके बारे में भी कुछ बोल देना
Vgaurd Jadoo 700va sab led jal Rahi hai ek ek karke running me output nikal Raha h bt 100watt dalte hi band ho jata h
👍👍👍🙏💯
Hello bhaiya mujhe na inverter repairing sikhna hai uske liye kya kya component rakhna jaruri hai bata sakte hai kya
(24×7Microtek inverter) mens changeover Nahin ho raha hai aur UPS se on bhi nahin ho raha hai output Nahin ho raha hai. on karne ke bad 2 second ke liye output ho raha hai FIR band ho jana. kaun sa parts Kharab Hai Kaun Sa perts check Karen please bataiye sir.
Powor cabal me curunt aa rha hai bhai ... Riley problem hai ky Riley konsi lagi h isme
Sar sine wave inverter plate me agar fhalt aa jai to pura plate change karna padega sine wave of square wave bare me bataye
Sir microtek 24×7 950hb pcb ko 1120hb men kaise conver kare.please
Hb950 me Low Batt Aa Raha hai Men Transfarmer Havi Magnet Bana Raha KYA HO SAKTA SIRJI BATANE KI KRAPA KARE
Sar Mere inverter mein EB 900 hai battery Mein Lagane se mance light jal rahi hai aur power Nahin de raha hai Sar please samasya ka Samadhan jaldi Karen
Microtek 24*7me overload hai driver ic shi lm 358 shi hai
Sarji microtek 24*7 inverter connect hote hi light bar bar fachulate hoti h
Sir please 🙏 sport LUXE model me battery low proglam kaha se solve hoga new model microtek ka luxe model me
14 no pin par to 0v chahiya backu mode pa, magar sheet par to 4.5 v likha hai
Mera inverter Mai be same problem ho Raha hai bhai .prycal ka 165 ka naya battery hai .ab kya Karu Mai o batao
Kk sir naye video ka notification nahi bhej dete hai
Luck fantastic
Sir mere pass microteck 1125 24×7 inverter h, uske peechhe jo single wire wali pin lagate hi overload batane lgta h , iska kya karn ho sakta h , please solution bataye
Driver ic lagane se overload ho ra he or drive na lagane se ok he
Sar microtek 1400 vA ka kit hai sab kuch thik hai lekin use per load dene per Lo battery ka indication a raha hai please help me
Hamare pass bhi jo inverter hai usame to battery 🔋 low ka problem aa rha hai.
Hello sir pin no 14 par 6v drive ban rhi hai LM 358 CHANGE KAR CHUKA HUN 832021 BHI CHANGE KAR CHUKA HUN MICRO IC BHI CHANGE KAR CHUKA HUN PHIR BHI PROBLEM OVERLOAD KI NHI JA RHI HAI
अपने पास 33pcb है कइ कम्पनी के
कितना सर्विस चार्ज लोगे सर जी?
Ac on krnese or invatar on kbhi invtar ac
Sar 3.6 48v maikrotek kuch samay chalne ke baad overloed batata hai
DG900 PLAK bord me lagate hai over lod problem sr solution please
Sir pls urgent hi 24/7 me mains ke baad output chali jati hi kya kre
Good video what is the number of ic
Microtek 715e2 plus me ac main lead me output mil raha hai jis se jis mains me lagane par overload show kar raha hai
Ampyar mitar ase us kiya jata hai inwatar par plz sir samajh oo
Micromax solar invartar ki microic ke data sit chahiye ki kis pin par kya volt hoga yah bar bar battery charjing problam rahta hai kaise cheq kare
Reset puse switch k piche me p f jal gya ha uska number btaye
83202 ke jagah pe 4082 lga sakt hai sir
Microtek 24x7 overload problem 358 sa problem solutions plz
sir mere pass terupowr 1150va Dps modle h on hote h overload m chal jata ?
माइक्रोटेक इनवर्टर सानवे 1660 सोलर बिजली सप्लाई तेज दी मोना
सानवी इनवर्टर सोलर माइक्रोटेक 1660 में बिजली टिप टिप
Microtek inverter Jyada load dene per battery lo likha hai problem kya hai
Microtek 875 mein lighting available light Nahin jalta hai inverter
सर जी 7545 के जगाह पर 3205या p90 ya p80 MOSFET लगाये kya
Ha
Thanks
Battery par tar lagte overload dekta ha sar
Sir mara amaron inverter 825va ka 200watt sa jiada load nahi la Raha hai
सर मेरा लुमिनियस 675 va चाजि्ग सही है लेकिन ओवर लोड दिखा रहा है और आउटपुट भी नही दे रहा है
Drive volt check kijiy
Apka inverter repair whatsapp group Hai toh invite link share Karo. Mera v-guard ka inverter overload Bata raha Hai.
Sukam falcon i smd kit ki micro ic pin details per video banaiye sir
Ok kosish karunga
2350 24v ovl
24×7me battery low ke video banaye
Mere paas 24×7 1125 inverter hai.normal load par thik kaam karta hai par 400 /500 Watt load deta hun to over load me chala jata hai.kya ho sakta hai.
Same problem. Any solution?
Levfast ups 12 volt ober load charging problam
Sir dg 900 out put nahi deta hain mains par ok but battery se output nahi deta
Nice bhai but fault create nahi clear hota hai
Microtek 3.5 KV inverter has tick tick sound when put on back up
Riley konc hai isme wo bta do bhai
Kya 12v adapter se inverter pcb check kar sakte hai...???
Sir Mara ko inverter wala group ma join kr do
Microtek 24 * 7 Shine wave on karte hi low battery ka problem
Luminous eco watt on karte hi overload blink karta hai
Sir cheng are cheng nahi kar raha24×7he
how to by pass overload sensor new smd EB700va smd microtech .
Dear sir 48 volt 3.6 kva invter start ho ke over load ho jata he please sujes me
Microtek me charging problem ka video banaye sir
Ok
Sir,,iska transformer copper coil hain ya aluminum ka?
Aluminium rahata hai
Sir mic mic 900 dg sw all pcb working ok but buzzer continuous beep..All transistor ok ..kya fault ho sakta hai?
Sir same inverter mein 260v aarha hai
Kiripa solution batye
To kya problem h
@@KanhaElectronicsGenius
220v out put anaa chahiye
Hello sir online training available hai kya
Abhi nahi h jab hoga to inform kar dunga
@@KanhaElectronicsGenius ok
Sir isme karcha itna h
Microtek inverter overload problem kese thik hogi
Sir ic pin details video mein saaf nazar nahi arahi h pin details send kijiye
Bhai mere pass bhi yahi inverter hai 950va usme har 3 4 seconds me battery low battery low ka fault aa raha hai please help me
UPS on hai lekin AC supply nahin
i have 1100va inverter. can i run my fridge ? it i s only 200watts. why not?