CRANKED BAR - SAAN DAPAT ILAGAY ANG CRANKED BAR NA EXTRA BAR NG ISANG BIGA?
HTML-код
- Опубликовано: 24 ноя 2024
- PARAAN NG PAGLALAGAY NG CRANKED BAR OR EXTRA BAR SA BIGA, MGA DAPAT TANDAAN KUNG MAGLALAGAY NA NG CRANKED BAR. MAARING ICONSIDER SA PAGLALAGAY NG EXTRA BAR SA BEAM.
This video is NOT sponsored. Some product links are affiliate links which means if you buy something we'll receive a small commission.
BUILDMATE: invol.co/cl5y7rd
Buildmate Online Depot
Welcome ka dito Ka-BUILDMATE! 👋
🚧Your One Stop Hardware Shop is always here
with the most complete home & living needs.
Be updated with our Special offers because every day
is Guaranteed LOWEST PRICE with us 🎉
✨DAILY VOUCHERS GIVEAWAY with just one click
in our ✅FEED Section & Chat button.
plus our Special 🚛 FREE SHIPPING deals
What are you waiting for?
Follow us and Get a Voucher now!
Home improvement design (Art Design PH): invol.co/cl5lx7p
Online Shopping Platform (LAZADA PH):invol.co/cl5lx98
Shop Online Specialized in hard to find items (Galleon PH): invol.co/cl5lxab
The Ultimate online shopping Experience (Ubuy PH): invol.co/cl5lxdb
Napakagaling nyo sir subra po akung natulungan ng content nyo,,mabuhay po kayo
Sir, can you make a video about when do we need MONOLITHIC (tuloy ang buhos) and when it's okay apply COLD JOINT (putol ng buhos). Thank you!
This is something I would also like to know. Lots of people wonder about this.
Galing buti meron mga gantong content para matutu kaming nag diy at maintidihan ng naaangkop at hindi nang huhula salamat master baging subscriber nadin😊
Ang galing Ang linaw mo mag paliwanag sir,Ang Dami ko Po natutunan
Baka po pede paano nman po bumasa ng elevation finish floor thanks
Good day po, thanx a lot po Sir Gabs marami po Ako natutunan sa Inyo, taga Laguna din po ba Kyo, God bless po sa inyo
Akala ko di ko maiintindihan. Pero naintindihan ko sya. Galing magturo.
Good day po. Kapag nagkagay po ng perpendicular stopper (50mm) doon sa bottom bar; possible po ba un?
WELL EXPLAINED CHEER SIR GABS...KASI KASALUKOYAN AKONG NAGPAGAWA NGAYON NG 3-STOREY...MAGANDANG REFERENCE..YONG MGA EXPLANATION..NINYO..ANG LAKING TULONG SA MGA KAHIT GRADUATES NG MGA ENGINEERING PEOPLE..GOD BLESS..BE SAFE AND WISHING YOU ALL THE BEST....
Salamat po
Sir ask ko Lang po, yon bang FTB pareho rin ba ang MGA pwesto Ng MGA bakal sa beam na NASA itaas? Tnx po
Sir thank you po ..napakalaking tulong po nito sa kagaya ko po nawala tlagang alam sa construction.. GODBLESS po marami po kayong natutulungan..
Yung ganitong explanation ang kelangan ko. Thank You Sir ! Napakalaking tulong 😊
thanks for watching and have a great day
Sir, request nmn po about sa purong buhos ba walls sa Bahay😊
Daghang salamat sir,, nka subs na Po,,more vid pa dagdag kaalaman pra sa mga steel man,, 🙂🙂👌
Hello po. Ask ko lang paano kunin ang haba ng hook ng extra bar?
Very nice information.
Sir tanong lng po. Ano ba ang saktong sukat mula tie beam to mating ng poste?
Tanong ko lang po sir alin po b Ang mauunang lagyan Ng rebars s beam shorter span po b o longer span. Tnx in advance po
Sir may video ba kayo para sa beam reinforcement pag naglagay ng floating column ? Thanks po..
maraming salamat po dami ko natutunan sa mga presentation nyu po
Ty xir nag follow na ako para marami ako matutunan.
Anong fb mo sir tatanong Sana ako kung anong kaibahan ng suspenden slab at both ways pareho Lang ba ang latag ng slab nun sir
Interesting n educational
Salamat naliwanaga na po ako
Thanks for watching
Ganda NG paliwanag sir
Boss sa cross beam po,na slabing po ay pwede ba yung L/4?
Hello all..ongoing pagawa nmin ng maliit na 5x4 pa chek po anu mali at anu idagdag..
Sir compulsary po ba ang cranked bar o depende nalang sa haba ng beam?
Goodevening sir. Paano po kaya kung maliit na masyado yng space para maglagay pa ng extra bar. Pde po ba ilagay sa bandang gitna yng extra bar para mkapasok po yng concrete mix.
Good evening sir 5 meters distance from each culomn anong size ng tie beam at ilan 16 mm po ang gagamitin wala po culomn between 5 metes culomn? Salamat po in advance?
Thank you po uli ser.. palagi po ako nanonood ng video nyo.. paulit ulit ser.. nagpapagawa po kc ako hanggang 4 floor.. Thank you po…
Happy DIY po
Idol baka puedo talakayin ang tungkol sa pag reduce ng size ng column sa second floor
Thank you.malinaw Ang explanation nio.
God bless us all
Salamat po
Thank you engr, for learnings
You are welcome and thanks for watching
Sir paano ba icompute yung 0.30L1 or L2 sa top bar at 0.15L1 sa bottom bar sa structural beam?
Tnx po Engr.Gab I really learn a lot from your titorials.God bless po
Salamat poh...
Dag dag kaalaman🙏🙏👷
Thanks po sa patuloy na support sa channel.
Very informative especially for a beginner. Free Learning on RUclips. Thanks for sharing
Salamat po
Thank you so much. Mas clear po kayo mag explain at madali kong nakukuha at natutunan. Pinasimple mo ang mga bagay na complicated i explain ng iba. Kahit di nag aral ng engineering ay nasusundan po kayo. New subscriber here.
Salamat and have a great day
Sir..paano din po kong 5m ang distance ng poste po..
Maraming salamat po
Welcome po
Salamat sir super informative ng content nyo :)
Gud pm sir, my video ka ba regarding sa reinforcement ng slab na may nakapatong na wall? Usually sa mga 2nd floor na may mga T&B..need ba talaga na may beam na maghold sa walls? Tnx po
Kung purpose ay para partition pwede na stiffener. Nakakatipid din kc kung nasa ibabaw ng wall ang may beam requirements.
Nice one engr.. solid follower po ako sa vids mo... Ask ko lang kung pwede ba ang 1:3:4 concrete mix ratio sa beam? Tnx
Sir anu po length nung bended na bar, ung sa dulo po??
Sir pag bonggalo house lang po ba pwde Wala Ng crankbar yong beam?
Explain nmn ng pagkuha ng width of beam and beam depth?
Nasa design po, pero may thumb rule din na based sa mga existing designs. Thanks for watching
Sobrang dami kong natututunan sainyo sir. Napaka galing mag explain. Thank you so much sir!
Have a nice day and thanks for watching
Maraming salamat sa kaalaman sir.
salamat sir sa pagtangkilik
Thank you sir napaka clear Ng lecture mo
Mag aral prin po
Salamat po
Naaalala ko tuloy ung foreman na nakasama ko. Nung NG rescue ako sa lucena Hnd nya alam ung L4. pag dating ko Doon sa site nakita ko ung mga extra bar naka dikit sa mga continues bar. Kaya Ang nangyare binaklas lahat NG extra bar. ganyan na ganyan ung ginawa ko nung pinalitan ko NG mga bagong extra bar ung mga biga.
Salamat eng.
Distance po kadalasan Ng lateral ties Ng beam Kasi iba iba Ang nakikita ko sir
Sir anong mas maganda contues crank bar ba?
Paano po details s hanging biga 6.5 mtrs,kudrado
Very imformative sir.subscriber po ninyo ako. Ano po ang standard size ng biga ng 3 G+ na building. Thnk you
Need npo ng structural analysis, pero based on my previous projects mostly 20mm diameter ang nagamit qng main bars
Salamat po sir, tanong lang po sir,ilan po ba ang kailangan na bar sa beam na may size na w-10" h-16" L-4m(10"x16"x4m) . Ok lng ba ang 4 na main bar,2 web bar at 1 crank bar sa L/4 at sa midspan sir?
Gud mrning sir,pwede kaya sa side ng beam ilalagay ang crank bar kung 3 main bar sa top at botom bar. Salamat hope for your reply sir.
Good day ser happy new year po pwede po ba pa advice kung pano mag bakal ng beem ang haba ay 7.5 meters walang poste sa gitna po ano po pati required na size ng beem at bakal thanks po
Need po ng STAAD ( Structural analysis and design)
Salamat boss. Sa dagadag kaalaman. Ko
Salamat din po sa suporta sa channel
Paano po ba ikumpute yung L /4, L/5,o L/6 po sir thanks po
ano ba ang L/4 po spicific lang po sir
Hi sir, new follower nyo po ako... May tanong po sana ko.. may pinagawa akong AFrame house na size 5.5x5m at meron syang 9 na poste...distance nya from post to post 2.5m...napansin ko lang po bakit wala po syang extra bar na nilagay sa beam? Sana po masagot nyo po... Salamat po, godbless
Dahil maikli lang po ang unsupported length
Yes malaking tulong po sir
thanks for watching , have a nice day
ser mag cocoment po ko anu daw po b yung cut bars oh oh pero iisa lng nman tawag sa extrabar...
Hello, ung cranked bars ang bent ng bakal sa L/4 , ung extra bar/ cut bar un ang bakal na di dumiretso at un ang binali sa L/4
Sir paanu poba malalaman kung ganu kalaki na boga ang dapat sa dalawang gradong bahay? Na 4m ang distansya ng colum
Kung di po typical ang bahay need ng STAAD
Thanks for sharing Bro Gab.. Dami kung natutunam
Salamat brother, God Bless you and keep safe.
Sir tanong lang po,
Bakit walamg nagwewelding sa rebars at culumn?
Hindi po kc weldable ang ibang rebars
Ano ba ang sukat L4 sir
Very informative technically
Thanks for watching
sir gsto qlang po malaman qng ano mas mahaba main bar or Extra bar tnks po sa sagot
Pag mainbar tuloy tuloy po
Sir gab. Meron po kc binibigay na babakuran. Ask ko po kung ilang 10mm ar 9mm ang gagamitin sa 6,000 sqrmtr. Salamat po
may video upload po aq ng bakod. Thanks for watching
pano mag design ng anguilar steel trusses na may 30-M span for gym, tnks po
Pa STAAD po, medyo malalaki po steel section. Thanks for watching
@@GabsRomano ano nga po b STAAD, tnks po
Sir pwde ba L/3 top L/8 sa Bottom?
sir pwedi ba mag crank bar pag ang beam para sa bungalow na may roof top 4m by 3.
5m
Okay po
Tanong ko lng po.bakit po kailangan pa na tinatawag na bangka baka sa began.salamat po
Para maipwesto ng maayus ang bakal kung saan maximize ang tensile strength nya
sit kailangan paba ng xtra bar o crackbar kung ang agwat ng poste 3 meters lang
Kahit wala po
Pwede ba sir di na mag lagay ng extra bar? If yes po sa anung scenario po?
Sir ask ko lang kung pwede rin itawid sa column ung crank bar and paano kya kung meron tatamaan na bar sa gitna?
Ok lang po, basta imaintain ang clear distance ng rebars.
Salamat sa reply sir follow up qstn lang pwede rin ba putulin ang buhos ng tie beam at saan distance po pwede mag putol?
Sir paano malagiyan ng tie bar o tie beam sa ground kung ang bagong itayong na bahay ay nakatayo na ang mga poste? Nakalimutan lagiyang tie beam sa ground kasi plano noon ay hindi na lakagiyan ng concrete beam at concrete floor sa taas.
Medyo mahirap po ihabol ung tie beam kc baka magcrack pag sobra vibration kaya ingat nalang po kung hahanap ng bakal at magchichip ng cement cover.
Sir ako nmn po column,, at tie beam wla po..pero merun po tie beam s roof lng po at sa gitna lng po may colum kabilaan ...balak k po kc maglagay ng 2ndfloor,
Salamat bro
Have a great day
Sir pwede po ba magkagay ng crank bar sa steel deck?
Pag two way slab may available na steel deck na perforated. May video npo aq dyan
Sir, ask ko lang magkano po kaya lahat magastos sa slab 32 sqm ang sukat.?
May video po aq nyan, per square meter kasama na decking,reinforcement,concreting,formworks and labor. Thanks for watching
Yung starting measurement po na L ay doon po ba sa kanto ng poste?
clear distance of column
Ask lang po, isang set lang po ba ng crank bar kada beam?
Depende po sa extra bars, thanks for watching
Hello po sir,need pa po ba e crank bar ang beam kahit may file ng hollow blocks sa ilalim or sa mga suspended beam lang ito dapat ilagay?salamat sa sagot
pareho lang po detail ng beam with the same condition , may chb man po o wala. thanks for watching mam
Sir ano tawag s puting n buong area bhay lalagyang eslab
Raft or matt foundation
Helow sir..tanong ko lng bakit yung iba nakikita ko sa gilid nila nilalagay ang extra bar?ano pinagkaiba sa explanation nyu dto sa video?slamat po
Kung kaya naman imaintain ang clear distance na 50mm sa rabars sa pinakaibaba thats good however kung di na kasya pwede na ilagay sa gilid ang iba provided na magbibigay ng allowance sa concrete clear cover para sa centroid ng mga rebars . Thanks for watching po
Sir pwede po ba hindi icut yn bar continues
Ang gamit ko po L/5 yung sa baba
Dapat I explain mo na kung bakit pinuputol un bakal, ano Ang purpose
inexplain niya naman
Hi Sir ask ko lang po. Pwede po ba hindi gumamit ng cranked bar kung marami naman po yong main bar. For example sir 4 meters yong beam tapos merong tig aapat na 16mm na bar sa up and bottom tapos meron ding tig dadalawa na 12mm sa gilid ng beam. Total main bars po ay 12. Okay lang poba yon? Sana masagutan niyo po. Salamat po.
Paniniwala ko kasi sir kung maraming bakal mas matibay.
May tama pong ratio ng bakal at cement sa section ng poste at biga, kailangan din maiwasan ang cogestion ng steet sa joint ng beam and column. Thanks for watching
Sir yung L/4 divide sa haba ng girder?at ang L/8 divide din sa haba ng girder?
Yes po
@@GabsRomano Salamat po Sir.God Bless Sa iyong vlog
Sir, kahit lang ba isang crank bar sa width ng beam ay 10"x16" sir
Sir applicable pa rin po ba ang Cranked Bar kapag Steel Deck ang gagamitin sa Flooring o Biga?Thanks...
sa steeldeck wala npo cranked bar, sa beam meron parin sir
@@GabsRomano, maraming salamat Sir..lagi akong naka abang sa mga Post o Blog nyo...medyo matagal tagal na rin akong Subscriber...
Sir anu po ang aking gagawin ang mid span 10 meters ang haba ng beam kasi ang balak wala ng column sa gitna at sa gilid 5 meters ang distance ng column pls
Bale 10 meters x 20 meters sa 3rd floor
Need npo ng Structural analysis and design para po cgurado.
Sir, please advise when to choose the rebar grades, g40, g60 or so forth....
mag grade 40 ka if 10mm dia. pababa gagamitin mo tas mag grade 60 ka sa 12mm dia. pataas
The best
Salamat po
Paano po bang sukat ng bend bar sir?
nsa video po sir
Thanks gab,
have a great day and thanks for watching
Cut bar at crank bar ba ay parehas
Sir pwd po bah actual pic ng arrangment nyan sir baka pwd nyo masingit sa presentation.. Thanks po.. From south cotabato