POURING AND LAPPING OF COLUMN: SAAN PWEDENG MAGPUTOL NG BUHOS AT MAGDUGTONG NG REBARS SA POSTE?
HTML-код
- Опубликовано: 13 окт 2024
- MGA DAPAT TANDAAN SA PAGBUHOS NG CEMENTO AT DUGTUNGAN NG BAKAL SA POSTE. MGA KAILANGANG MALAMAN SA PAGGAWA NG POSTE.
This video is NOT sponsored. Some product links are affiliate links which means if you buy something we'll receive a small commission.
BUILDMATE: invol.co/cl5y7rd
Buildmate Online Depot
Welcome ka dito Ka-BUILDMATE! 👋
🚧Your One Stop Hardware Shop is always here
with the most complete home & living needs.
Be updated with our Special offers because every day
is Guaranteed LOWEST PRICE with us 🎉
✨DAILY VOUCHERS GIVEAWAY with just one click
in our ✅FEED Section & Chat button.
plus our Special 🚛 FREE SHIPPING deals
What are you waiting for?
Follow us and Get a Voucher now!
Home improvement design (Art Design PH): invol.co/cl5lx7p
Online Shopping Platform (LAZADA PH):invol.co/cl5lx98
Shop Online Specialized in hard to find items (Galleon PH): invol.co/cl5lxab
The Ultimate online shopping Experience (Ubuy PH): invol.co/cl5lxdb
+35sec. Ads completed keep watching and support especially Ads from Al Khafji Saudi Arabia
Sir, request po ng stairs naman sa sunod. Salamat po.
Sir, puwede po bang gawa kayo ng topic about sa 6meters ang layo ng poste. ano pong sukat ng column at beam at foundation depth para po sa apat o limang palapag na residential/apartment building.
Salamat po in advance
Thanks for the information Sir. watching from KSA🇸🇦🇵🇭
So nice of you sir, salamat sa pagtangkilik.
thanks bro. npaka galing mo teacher.
Ask ko lang po
Pakisuyo.gawa kayo ng video na
4floor
Size ng poste biga .tie beam at footing.at size po ng bakal.thanks po sa response
Masalimuut ang paliwanag,sna yum madaling intindihin
Splacing ng 16 mm poste grade 40 salamat po idol
Sir salamat sa video nyo marami ako natutunan, ask ko lang din paano nman ang dugtungan sa slab kung kailangan din mag putol ng buhos?
Andito po ako para may matutunan sa pagtatayo ng bahay para sa pangarap kong bahay
Thanks for watching
Nakaka tuwa engineer na natutulungan mo ang mga viewers na maintindihan ang mga dapat sundan sa pag construction. May tanong ako ginagawa ba dito sa pinas ang flat beam? Pwede ba mabigyan mo rin kami ng idea kung paano ang detalye, thank you...
Isang tagasubaybay po kmi sa vlogs mo idol, sa ginagawa po naming bahay, dito po ako kumukuha ng info
Salamat boss wala ako ke idea idea now lng ako natuto mabuhay kayo
Maraming salamat po engr, or architect Gabs Romano maraming po Ako naidagdag na kaalaman mula po sa mga video niyo isa po akong skills, salamat sa mga vlog niyo saludo po Ako sa Inyo, God bless po sa Inyo, Nuwel po ng Laguna,😊😊😊
Thank you for the support on my channel.
thank you from Isabela
Engineer linalagyan pa ba ng epoxy cold joint ng column or diresto buhos na lang din ng semento?
Sir sana sir madiscuss nio din po ung construction joint...
Include nio na rin yung adeantage and disadantage ng partial beam at monolithic pouring sa steel decking..
Sir, wala pa po gaanong topic pertaining sa construction joint.. Ung tipong hindi nabuhusan ung buong slab. Saan pwede tumigil sa pagbuhos ng slab ay tie beam?
Hello po sir sana mapansin po ninyo. Nais ko po sana mag padagdag ng palapag sa bahay namin. 22sqm lng po sya. Tanong q po. Ung bakal po ng poste ay putol sa 3rd floor nakalitaw lang sa sahig ay 1inch pwede parin po b ito madugtungan? Para poste pa 4rth floor anu po ang gagawin? Weldingan po b sya? Salamat po
Salamat po enjeneer dagdag kaalaman po sa akin bilang construction worker
More videos sir dami kung natutunan
one of my new favorite channel for sure
Maraming salamat po.
Salamat sir gabs. Dininig mo ang tanung ko. Continuenlang po sa pag share ng iyong kaalaman.
Salamat din sir sa pagtangkilik. have a nice day
Ang linaw Ng pagkakapaliwanag sir,isa rin po akong manggagawa Ng bahay dagdag kaalaman po ito saakin, maraming salamat po ingat palagi godbless
Maraming salamat po sainyong mga tutorial malaking tulong sa aming mga magpapagawa ng bahay. Mabuhay po kayo at godbless..
Salamat engr
Hi boss ang dami ko nang natotonan sa yo tyvm engr.ur my idol godbless sana ipagpatuloy mo ito
Sir gawa ka nman video 3-storey residential house about sizes ng columns beams & footings.. sizes of deformed bars etc. thanks in advance po
will include po sa list sir
Nèed ko ren sir.
Thanks..
God Bless..!
ayos very informative as a structural engineers, as a kasador wala ka bang mga patakaran sa arrangements ng mga stirrup joints between slabs or slab and gilid ng structure. Kritical sa arrangement ng SLABS, edge slabs sa gilid ng mga stairs, most commonly errors as very experienced KASADOR, may shortcut drawing ka how to figure out base sa structural engrs.etc diy and kasador
Sir gab puid bang bang sa ilalim ng biga mismo ang putol ng buhos?maraming salamat po
pwede nyo din po ba idiscuss ang difference ng precast house (camella ,lumina, or bria) vs traditional CHB,beam and post made house.
Ask po footing to footing tie beam ok lang ba na putol Ang pag buhos Ng cemento
Pwede ba silsilin ang semento ng poste pra dugtunfan for 2nd floor
😊
Keep watching and support especially 80sec. Ads from Al Khafji Saudi Arabia.
Sir baka puwede po maka hingi sukat para sa bakod na may gate na 3meter ang lapad. Matibay din poba ang 30x20cm mas matibay poba kapag square ⬛ column? Plano kolang po hatiin ang 600cm. Bali 200cm lang Mula flooring ang taas... Padamay narin si Yung sukat po ng stirrups? On napoba Yung 80cm pang paa?
nice explanation and very clear. thank you for your video.
salamat po
Ok thanks
Sir Gabs,pwede bang buhusan mag ftb at slab ng monolithic, the slab is somewhat designed as pressure slab.gusto ni contractor di nya buhusan ng bup ang ftb at yung matitira dun nya ulit bubuhusan kasaby ang suspended slab.may epekto po ba yan.the same design mix ang gagamitin.which is construction wise ay tama.paki comment po Thanks
Thank you po sa pagbahagi Ng inyong kaalaman Sir new subscriber here😀😀
Salamat din po sa panonood
Kung ang column ay subjected to seismic dapat sa gitna ang lap splice mo to develop plastic hinging at mid ht . Kung Meron kang shear wall ibang case naman yon
Ano po bang magandang laki ng poste sa two story with roof deck, ilan pong sixteen mm ang pwedeng ilagay dun? Ano po bang laki ng parilya ,ano po ang pwedeng gawing sterap ng poste,,okay lng po na ba 8pcs na sixteen para sa 30 by 30 pero ang fisinish niya pong buhos is 35 by 35.
tnx a lot, sir! very informative..
Thanks for the info. Sana ay talakayin nyo po ang steel Deck na nauuso ngaun at ano ang mga advantage at disadvantage nito.salamat
Hello po, meron npo aq video sa steeldeck. ung tipid sa bakal, tipid sa porma may kisame pa. andun po ung specofications, details, profile at ung direction of laying .
Sir pwed malaman kung anong exact measurement ng foundation ng bahay kung ito ay two story house pero itatayo sa isang slope area .
thanks sa information sir, irequest ko po sana madiscuss nyu dugtungan tulad ng beam kung saan walang nakaprotrude na rebar, anu ang mga suggestions at pwede gawin. thanks in advance
sure po, isama q po sa list ng gagawin qng video, salamat po sa pagtangkilik. have a nice day
Lods tnx
Sir gab? oki lang po ba na di puno ang buhos ng viga? kasi di pa nman kami cgurado kung kailan kmi mgapapa.second floor
Thank u, timing ito need ko ito ngayon.
sundan nio lang po ung plano para di po kayo maligaw.
tanong ko po sir, papapaano naman yung patungkol sa biga or beam, saan po pwedeng magputol at magdugtong ng buhos ng tie beam or croos beam?
Hello Sir, thank you for sharing knowledge. Much better appreciated, Kung uulitin mo Yung Content na ito incorporating the realistic construction, ie: location of splice Kasama ang depth of Girders
Thanks po sir gabs dami q n natutunan sau ngaun Alam q Kung magkano Ang magastos Kung pagawa q bahay nmin
salamat din po sa pagtangkilik
Gudpm ho. Saan ho ba ang reference ng L/4? Sa ibaba po ba ng biga o sa ilalim ng biga? Salamat po
Sir anu ibig sabin ng RB beam
sir more power po, thank you sa information n sinishare nyo. request po sana ako ng 2storey with roof deck if pwede po.
soon po, thanks po sa supporta
Hello sir! Thank you for sharing us your knowledge. Sir please pasagot po. Paano kung hindi nasunod yung tamang hinto ng buhos. Sa mismong papatungan ng beam na kasi hininto yung buhos doon sa bahay na pinapagawa ko. Ano po kaya pwede gawin doon? Please answer sir. Thank you and God bless!
Need po mawala ung cold joint, pag magbubuhos po pakalinisin ung termination joint saka mag grout cement. Thanks for watching
hi sir.. pwd po ba kayo gomawa ng video ilan po standard sukat po ng stirrup and hoop pra po sa beam at poste.. mapa 1st floor po or 2nd floor. at ano standard mga bakal dapat po gamiten pra po dito.. salamat po advance
ok po pero meanwhile please watch my other videos, baka makatulong po. thanks for watching
Gaano ka lalim ang poste at gaano kalagi ang puting sa area na may 25 square meter in 3 story
Sir tanong ko lang po pagkatapos mag buhos ng beam at slab sa first floor alam ko po sa vlog niyo yong curing process kaya lng kailan po pwede magsimula magtrabaho sa mga column para ituloy yong structural ng second floor kahit hindi po tatanggalin yong mga support ng pg buhos. Salamat
hello po, 7 days pwede na as long as wag muna babawasan ang shoring. thanks for watching
Engr. Ano ba ang purposed ng eccentric footing? Maraming salamat po sir.
sir pwde mag tanong .. mahalaga sana tong i tatanong ko sana makasagot kapo
paano nmn po kapag may tambak muna ang lupa? gaano ang preparation ng reinforcement?
Sir good day... Ang epoxy grouting in beam and column connection okay ba sa footing ang dugtungan para sa mag second floor
ok po sir
Sir ask ko lng.professor PO b kau?kci mlinaw PO pliwanag nyo
new subcriber po sir gabs,thanks po sa pagtuturo
salamat po uli sir,"GOD"bless po sayo and to your family
clear height po ng column ang pinag-uusapan diyan. 3.2m - depth of beam pa ito.
finish floor to finish floor ata un sir
Clear height from FFL to bottom face of the slab not the beam.
Halimbawa mataas ung tambak, hindi aabot sa 2nd floor ganun din po ba? Salamat
Thank you very much Gabs Romano sa iyong tutorial.
salamat po
ur welcome po
Referring to 9:40 up, ang ibig sabihin ba ng L/4 ay dapat tumigil ang buhos 80cm BEFORE the beam or 80cm AFTER the beam kung tama ang pagkaintindi ko po...less than that we will be entering maximum shear stress of the column which we do not want which I agree. Marami kasi akong nakikita dito sa YT na sa floor line ang umpisa ng buhos at sa lower beam line nagpuputol dahil iyon ang convenient at madaling gawain para sa sunod na formworks which I think is very wrong and dangerous pag sa earthquake. Please clarify po. Nice lecture po salamat ☺
L/4 is computed from the bottom face of the slab pababa. You must avoid the beams during 1st lift pouring of columns. During monolithic Pouring ng slab & beams, mauunang bubuhusan iyong remaining parts ng columns dahil mas mataas ang design strength ng columns
Good Afternoon po Sir Gab, tanong ko lang po kung pwede ako sa inyo mag pagawa ng Plano ng bahay ,, 2nd flr. semi commercial ung baba, residential n po ung 2nd flr. may sukat n 120 square meter
maraming Salamat po.
You can reach me through my messenger gabs romano.
Sir ok lng ba putol yung buhos sa slab?bale 6x6 yung bhay..6x3 lng yung binuhusan..yun lng kasi kaya ng budget..may mga abang nmn na bakal..ok lng ba magdugtong ng bakal sa gitna ng slab at beam
Magandang araw Sir Gab ang development length po ba sir ay kahit sa saang direction like pag ang rebar ay nasa lower portion ng FTB ang bend ng dev length at pataas or pwede rin pababa ang direction ng bend. Salamat po
Ung rebar sa ibabaw pababa cya, ung rebar sa ilalim pataas. From compression is upward, from tension is downward sa support.
good pm ser makakabili po ba ng steel deck khit kunti lng po. at san po owd makabili thank u po
pwede po ba mag bawas ng size ng bakal sa 2nd floor? ang ginamit sa ground ay 8-16mm. ano po pwedeng gamitin na sukat sa 2nd floor (roof deck)
Hi sir Gabs may nakita po ako na yung splicing eh dapat staggered ano po knaibahan nito kpg pantay pantay ang pagsplice ng vertical bars?
Sir Gabs, tanong lang po, bakit po tie wire ang ginagamit sa rsb at hindi welding? Salamat po and more power.
Subscribed more power po Sir Gabs. Ang dami ko po natutunan.
salamat din po and have a great day
very informative, ano po ang background or qualification nyo? new subscriber
Salamat po
Great topic sir!!! Thank you!
ur welcome po and thanks
Sir sana naipaliwanag niyo ho ang tungkol sa pagdugtong ng mga bakal sa poste na dapat di lahat ng bakal ay nasa isang location lang ang dugtungan dapat 50% lng ang bakal na nka spliced at 50% ay deretso.Kaya ang bakal dapat di lahat ay same length para di mapa isang location lang ang splicing.
absolutely po at least alternate
sir gabs magandang gabi po..tanong ko lang po kung if nabuhusan na yung slab tapos abang lang muna po yung bakal sa mga poste gano po ba ang minimum na haba na bakal na kailangan iabang pag tapos magbuhos ng slab..6 pcs na 12mm po ang bawat poste
Sir ppaano gumawa ng loft house ang size po 3x5
sir pwede pong mag request papano naman po ang dugtungan ng flooring at beam salamat po
kung sa dulo po ng beam lagyan bent ung rebar ng floor up 7" or 12db , kung continuous naman po ung rebar 50db or 500mm
hillo po 2nd flr slab na ang bahay ko mag add ako ng 3rd sampo na ang poste nya kailangan ba may additional ilan ang aditionalna poste.. ang sukat ng pondasyon 1mx1m w ang 1.5ft hight 12mm ang cabelya
Sir, ano po ang dapat gawin pag nkalimutan mglagay ng abang sa ppste. Kailangan ksi para sa pipe chase. Thanks!
need po na i site visit and be careful po sa chipping of structural parts
Sir Gab, pwede maputol sa FTB, then next lift ay yung shaded part mo?
mas ok po kung sa tamang dugtungan . Thanks for watching
Mgkano po b tamang kontrata Ng 48sqm. floor area , 2 storey , 4 bedrooms . Sna po mtulungan nu ako salamat po. Maximo Ng taytay rizal
Hello po sir gabs.pwede po bang buhusan ng concrete cement na may kasamang rebar ang steel post..pra mas lalong matibay ang steepost???tia sa reply..
Di ba dapat and splice ng column reinforcement ay middle third of the column (L/3 and splice are staggered)? Middle third is zero moment di ba?
Sir Gabs pwede na ba an beam size ng column 20x35cm with 6pcs 16mm rebar for 2 storey with roofdeck? Ground floor area is 3.5x8m lang naman salamat
Sir, paano po ba malaman ang height ng column? From flooring to tuktok ng beam po ba, o yung clear space po between flooring at beam?thank you po
Usually may mga height na naka indicate na Finnish floor to floor Meron ding top of beam. Kinoconsider din ang ceiling height kc may gusto high ceiling at iba mababa kc tilid daw sa electric consumption pag nag Aircon, ung iba kinoconsider ang mga ilalagay sa ceiling tulad ng piping atbp.
Sir Gabs, dba pwedeng punuhin na lang buhos ng column para wala ng dugtungan at ipapatung na lang ung beam.. salamat po ulit sir.
Iniiwasan po na magka cold joint dun saka mataas ang stresses
Pwede po mag joint ng beam sa existing beam?
Hi Sir Gabs, Good afternoon po... Thank you so much sa pagtuturo po ninyo. I really appreciate it. Keep safe and God bless po...See you.
ser magandang araw itanong kung makakasama ba sa biga yung may krak nagahibla ng buhok hindi puba ito maka epekto sa stractural napang 3floor .salamat
Need po ng actual inspection especially kung sa structural ang concern.
Sir pwede ba unti untiin ang pagawa ng bahay poste muna pag may budget naman saka umpisahan uli.
Yes po marami pong nagpapagawa unti unti, sa umpisa po need ung pundasyon hanggang sa maiangat sa ground ung poste at chb, make sure po na malinis at maayos parin ung terminations pag itutuloy nio na. thanks for watching
Sir Gabs, sa vertical rebars sa wall ng concrete tank saan po ba minimum distance from the slab pdeng mag lap? Ang intention po is para mas madaling gawin at di na maglagay ng support sa pag sway ng mahabang vertical rebars. Thank you
Ok lang ba sir na ung beam eh naka patong mismo sa column o poste
Sir yong bend mo sa vertical bar sa footing hindi naisama yata dapat 3.2 + 1.5 + .30 = 5.0 m pls, correct me if I 'm wrong.
You are right, thank you po
Hi sir. Good morning.. any suggestion po kapag nag chipping sa column para malagyan ng footing tie beam. Ano po kayang pwede gawin if ever na nabuhusan na yung column at footing tie beam
Need po ng actual visit ng professional para makita conditions, wag po basta mag chipping baka mag crack lalo na kung malaki concrete cover.
Thanks for sharing your knowledge sir, more videos po..
Sir good day po. Maaari po ba na I-beam ang gamitin para sa 2nd floor kahit ang dudugtungang poste sa 1st floor ay RCC column? Ang nangyari po kasi ay 1st floor muna ang ginawa then itutuloy na lang ang paggawa ng 2nd floor some other time.
pwede po ma I-beam basta maayus po ung termination, mag aanchor bolt and base plate po sir
Ok langba sir sa may biga o tiebeam pinutol yung buhos ganun kasi nakita ko pag gawa 'g bahay ko