Ito ang the best bukod s nagsasalita si kuya habang pinpaliwag isa isa s mabagal n paraan pra mkasunod ka d tulad nu g iba ang layo ng video at un is nman nk fast forward mga tanga. Good job sir
Excellent presentations Bay Froi, average extension users don’t even think the voltage drop electricity coursing through the wire of extension chord, it’s always obey the Ohm’s Law, the Voltage equals current times resistance. The same as we runs a household wirings how many receptacles from the first run till the last runs. Now with inventions of EV cars some household members doesn’t know between the 15 amps and 20 amp wall outlet, the innocent mistakes leads to dangerous overheating (and melting) of receptacle. Where i am is the 15 Amp and 20 Amp receptacles can be mistakingly the same unless we have to educate some of the household members the difference. Extension chord are always labeled according to the size of the wire inside the chord. The #12 AWG, #14 AWG, or 16 AWG, and these are 110 to 120 Volts rated. The #10 AWG comes with different prongs and can not be plug to the outlet, which is the larger the number of wire, the thinner the wire is. On my own little shop i have so many different extension chord length and sizes, and always properly labeled for its purposes, season tech people like my best Bay Froi can tell by the size and amperage of the chord itself, the rest is just plug it in and the innocent mistakes happens. Reminder to to all extension users, don’t ever ever and never removed the grounding prong just because the outlet are two prong, we can use an adaptor without breaking the extra three ground prong. Another things is in every 100 feet of extension chord this causes a drop of voltage, to compensate for the voltage drop we have to know the device connected how many amp draw, or increase the gauge (thickness) of wire to prevent current drop. Buddy Froi can gives you example from #14 AWG to # 12, this stepping up will prevent current drop over the 100 feet run. Now even if you increase the chord sizes, another things to considered is too many electrical device are plugged into one receptacle, overloading can occur. Some outlet have one dedicated circuit like one receptacle of 15 Amp or 20 Amp, but this may takes so many extra space or knockout on your circuit breaker box, an extension circuit box is recommended. I don’t know nobo dy knows about the quality of each extension chord because our market today has been flooded with counterfeit electrical goods, even the USA some company got caught by the Federal Government selling made in the USA from China, how do we know, only time will tell. Ako Bay Froi naguba akong weed whacker unya mogamit ko ug electric weed whacker, may 100 feet ko nga chords, ako gigamit ug ang multiple resettable outlet kay medyo me init gyud ang wire, unya mi tripped and multiple outlet. Kong wala nako gamiti sa multiple outlet that could burn the extension chord wire, the breaker still in close positions kay ang amp draw dile dako kaayo taas nga mo tripped ang breaker, akong wire ma sunog. Now with some experienced on the fields as HVAC/R myself that helps me to do some protections from my getting wire so hot and burn. Ang pinaka taas bay Froi akong gamiton mga 75 ft (25 m) labina sa rooftop nga dile nimo makita ug masimhutan nga nag aso na ang chords kay open air. Karon among uban help sa trabaho ilang dugtong ang 100 feet chord to another 100 feet, that makes 200 feet. Mahitabo ni ingon niine kay each average user needs an educations, ug karon maayo ni imong presentation Bay Froi. Keep up the good works and more educational presentations. From Leyte.
Nagpagawa sakin un jowa ko na teacher, ganyan gnamit ko kasi sa school nya gnagamit and medyo clumsy xa. And matibay un material nyan. Also with child safety din.
Share ko lang po, maganda din po bumili ng extension sa deeco, may nakita ako isang heavy duty extension na gawa nila na naka no. 14 royal cord worth php700 to php900+ anim na din po saksakan
Importante yang ground connection. Sa ibang bansa, mandatory yan. Ewan ko ba kung bakit hindi gawing batas na ang mga bagong construction na bahay ay mandatory na yang may mga ground wire sa Pilipinas. Lalo pa na 220v dito.
Gnyan gmit q na outlet Sir ung pinaka heavy duty ng Omni, natesting q sa skul nmin nun sa portable welding machine nakisaksak ung mga gumagawa ng d nagpaalam buti hnd nasunog kaya alam q na matibay 😁
There is no such things as heavy duty, the thick and the thin, the long and the short wires always follow the Ohm’s Law. Doesn’t mean heavy duty wires you can connect more than the wires amperage capacity to 80%, the 20 % remaining amp is for for expansion when the the wire itself heats up due to equipments and lighting start up, the inrush current together with the proper size breaker. We have more equipment where i worked as HVAC/R, our 300 tons chiller VFD wirings had a exhaust fans and being cooled off by a chilled water. That’s how the wiring protected specially some enclosed spaces, yes the wire on this humongous chiller are properly designed as we called it “Heavy Duty”, the problem the name heavy duty is just a labeled without extra protections cooling this wirings melted due to the hot enclosed spaces and inrush current from the amperage draw from the equipment. Is it heavy duty like a commercial grade wire better than the commonly household wire are better, yes, on the house wiring if you have a small shop like my Fave Bay Buddy Froi, have to have a good size wiring and he knows that. Sa school nyo nakisaksak iba sa welding machine at buti nalang hindi nasunog, guess what features protect the wiring when overloading happened…the breaker. Could be the breaker tripped and open up that cut the power, the other things kong malaki-laki ang amperage sa breaker everything toasted. Now the person asked someone on the shop knows about the amperage of the breaker or the shop people knows itself, this is what we called an Innocent mistakes and causes property damages. Now we take take advantage of Buddy Froi very detail and professional presentations although some of the details wasn’t there but the most specs and info tells us what to do. So don’t get mistakes with the label Heavy Duty because the Ohm’s Law dictates the wirings protections. Daghang Salamat, from Leyte.
Share ko lang po, para madistinguish po yung line and neutral sa flatcord, yung neutral po ay may mga ridges yung side then yung hot wire po plain lang po yung side, napanood ko lang po sa vlog ng mga foreign electricians
@@poyim256 to avoid confusion have your multimeter ready, things happens sometimes the person and we called it a backyard electricians that doesn’t know between the hot and neutral. With the multimeter you can tell the right polarity, sure light bulbs lit but some appliances have to be in right polarity will be damaged, some multimeter comes with NCV, None Contact Voltage.
Idol pwede po ba magtanong kung may video po kyong extension cord para po sa inverter welding machine 300amps or pwede na din po iting gamitin? Salamat po.
sir halimbawa gagawa aq na ang gagamitin ung outlet mismo bahay na dalawang 2gang outlet pwede bang ung pangalawang 2gang outlet ay nka tap sa mismong wire na flatcord #12 or 14? para hnd sya octopus connection? kumbaga parang wiring sa bahay kapag dalawang 2gang ang gagamitin gnun style. pwede ba yun sir? yung mgtap sa flat cord wire?
Sir safe ho ba gamitin tung omni heavy duty outlet na naka intact lang na nakasaksak sa may outlet ginagawa ku ho kasing extension lang ng tv at cignal intact lang ho sa outlet hindi kuna tinatang gal hindi ho ba umiinit yung light indicator nito pdx wire ho ang gamit ko at heavy duty plug salamat po God blessed
Sir , good job po , pwede po ba ganyan heavy duty extension cord , gagawa ako ganyan heavy duty extension cord , about 20 to 25 meters ang haba , hindi ba sya mag-iinit kung sakale , thanks ,
Hello po sir ..new subscriber nyo po ako ..tanong ko lang po ,pwede po ba isaksak ang refrigerator po na 220v dyan at saksakan din po ng heater?at magcharge ng phone ..sana po masagot ..thank you and Godbless po
Thank u idol Kasi nakita ko sa online daw maganda Pala protection balak ko lagyan sa akin idol, pero nag tanong ako Muna sayo kung okey ba thank u idol god bless....
Salamat po buti nalang di pa ako nakabili ng heavy duty plug at extension outlet. Pansin ko kasi mas user friendly yung ganitong setup lalo na di mahirap maglagay ng wire sa loob ng extension wire at plug at sigurado na hindi ito madali matangal dahil screw type na at yung feature na pag kakapitan ng wire na may goma is super ayos talaga sigurado na hindi mag lo loose yung wire sa loob @@Buddyfroi23
hello po sir... may binili ako portable IGBT inverter welding machine na 300amps., gamit lang sa bahay pang project.. anu pong size ng wire extension dapat Kung gagamitin? salamat po sir and god bless...
@@Buddyfroi23 that’s what we called a very professional answer from certified and qualified electricians like Buddy Froi, in case of doubts dealing with electricity called a professional.
Sabihin nalang po natin naka full wave at ilan naman pag sa spot lang. Pasensya na po dami kung tanong HAHA dumating na kasi yung inverter welding machine ko nasa safety first research ako ngayon hehe @@Buddyfroi23
@@Buddyfroi23 Sadly yung nabili kung inverter welding machine na yamato ang brand ay hindi gumagana working naman yung unit pero hindi maka penetrate in short walang arc sa bakal pag e dikit yung welding rod. Malaki pa naman nagastos ko sa heavy duty extension wire almost 700+ tapos yung result ay nakaka lungkot..
sir balak ko is diba meron nako nakalagay na outlet sa bandang likod then nakasaksak na lahat don ung mga pc, speaker, monitor, ilaw. Then ung wire non is dadaan sya sa switch na yan then sa line 1 and line 3 ko ilalagay then mag tatap ako ulit ng wire na may socket na sya then ilalagay sa line 1 and 3 then para pag naka switch off walang pumapasok na kuryente patungo sa outlet na nakasaksak. Yung outlet is royu na may 3 socket. Then wire ko size is 16. Ang di ko alam kung ilang amp kailangan ko na switch para mas okay kung 10a or 15a or 30a
Sir, advisable po ba na gumawa ng extension cord na madaming outlet para Isang linya lng Ang saksakan para sa aming sound system para Hindi madaming extension wire ang gamitin. Parang bawat 3meter my outlet
Sa heavy equipment na gamit Lods, 2gang extension outlet ang advisable...sa 4gang extension outlet mabuti lang yan sa mababang wattage na gamit...although naka design naman ang outlet sa 15amp ang rated...ty
Sir, may tanong po ako, hanggang ilang meters yung paggawa ng extension bago magkaroong ng wattage drop? Balak ko po kasi gumawa ng 10 to 15 meters na extension gamit ang 12awg na flat cord, for construction purposes lang po
@@Buddyfroi23 thank you sir, binigyan din ako ng stool wire sa DIY Hardware, ayaw ko naman gumamit ng royal cord dahil lumalaban..Kaya 10 meters na lang gagawin kong extension outlet
Buddyfroi San Po ba applicable gamitin Ang # 16 na flat cord wire kasi dito Po saamin na pansin kopo kasi #16 Ang Gina gawang extension wire pwedi poba Yun?? Sana mapansin pang dagdag kolang sa kaalaman ko
Good day! Wala po bang magiging problema kahit 20A ang ginamit na plug? At ang extension outlet is 15A lang? Hindi po ba mas maganda if parehas 15A ang gamitin na plug sa 15A na extension outlet? Sana po masagot
Good day idol Tanong ko lng Po may welding machine Po ako 300 amps ilang amps Po sa main breaker.may naka install na Po 2 breaker na 15amps at 3 na breaker na 20amps tapos yong main breaker ko Po 80amps. ngayon magdagdag ako Ng breaker para sa welding machine idol baguhin ko pa ba Ang main breaker at ilang ampere Po para sa welding machine.. Salamat idol
Pag parehong naka coated insulation ang dalawang wire talagang naka line to line pag isang wire lang ang may coated sa kabila wala at naka aluminum wire yon ang line to neutral...
Ito ang the best bukod s nagsasalita si kuya habang pinpaliwag isa isa s mabagal n paraan pra mkasunod ka d tulad nu g iba ang layo ng video at un is nman nk fast forward mga tanga. Good job sir
Thank you Lodz...God bless
Ayos...salamat sa idea. Sana makahanap din ako spool wire na walang laman
Maraming empty na spool sa hard ware Lodz...humingi nalang kayo doon dahil itatapon rin nila yon...hehe
Thanks sir Buddyfroi napaka linis NG turo mo. And thanks din sa natutunan ko na safety sure gagawin ko yan.
You're very welcome Lods...god bless!
galing mo.idol..thank you sa patuloy mong pagbbigay diskarteng electrician
God bless Lods!
Magandang explanation idol marami kaming natutuman sa channel mo thank u god bless 🙏🙏 idol..
You're very welcome Lods! 👍
Malaking tulong sir... Salamat ng marami sa idea... Gumana na ang aking extension wire...
God bless Lodz 😀
Ganda Naman Ng extension mo lods,thanks alot sa sharing,Minsan pa shout out from.Antipolo City,Riza.southern l Luzon
Sure...cg Lods sa next video....ty
Salamat lods mga tinuturo niyo god bless po
You're very welcome Lodz..
Another knowledge napod idol Froi, God bless...
Welcome Lods!
Inorder ko na lahat ngayon sa Lazada..gagayahin ko yan heavy duty extension chord
Welcome Lods...God bless
Excellent presentations Bay Froi, average extension users don’t even think the voltage drop electricity coursing through the wire of extension chord, it’s always obey the Ohm’s Law, the Voltage equals current times resistance. The same as we runs a household wirings how many receptacles from the first run till the last runs. Now with inventions of EV cars some household members doesn’t know between the 15 amps and 20 amp wall outlet, the innocent mistakes leads to dangerous overheating (and melting) of receptacle. Where i am is the 15 Amp and 20 Amp receptacles can be mistakingly the same unless we have to educate some of the household members the difference. Extension chord are always labeled according to the size of the wire inside the chord. The #12 AWG, #14 AWG, or 16 AWG, and these are 110 to 120 Volts rated. The #10 AWG comes with different prongs and can not be plug to the outlet, which is the larger the number of wire, the thinner the wire is. On my own little shop i have so many different extension chord length and sizes, and always properly labeled for its purposes, season tech people like my best Bay Froi can tell by the size and amperage of the chord itself, the rest is just plug it in and the innocent mistakes happens. Reminder to to all extension users, don’t ever ever and never removed the grounding prong just because the outlet are two prong, we can use an adaptor without breaking the extra three ground prong. Another things is in every 100 feet of extension chord this causes a drop of voltage, to compensate for the voltage drop we have to know the device connected how many amp draw, or increase the gauge (thickness) of wire to prevent current drop. Buddy Froi can gives you example from #14 AWG to # 12, this stepping up will prevent current drop over the 100 feet run. Now even if you increase the chord sizes, another things to considered is too many electrical device are plugged into one receptacle, overloading can occur. Some outlet have one dedicated circuit like one receptacle of 15 Amp or 20 Amp, but this may takes so many extra space or knockout on your circuit breaker box, an extension circuit box is recommended. I don’t know nobo dy knows about the quality of each extension chord because our market today has been flooded with counterfeit electrical goods, even the USA some company got caught by the Federal Government selling made in the USA from China, how do we know, only time will tell. Ako Bay Froi naguba akong weed whacker unya mogamit ko ug electric weed whacker, may 100 feet ko nga chords, ako gigamit ug ang multiple resettable outlet kay medyo me init gyud ang wire, unya mi tripped and multiple outlet. Kong wala nako gamiti sa multiple outlet that could burn the extension chord wire, the breaker still in close positions kay ang amp draw dile dako kaayo taas nga mo tripped ang breaker, akong wire ma sunog. Now with some experienced on the fields as HVAC/R myself that helps me to do some protections from my getting wire so hot and burn. Ang pinaka taas bay Froi akong gamiton mga 75 ft (25 m) labina sa rooftop nga dile nimo makita ug masimhutan nga nag aso na ang chords kay open air. Karon among uban help sa trabaho ilang dugtong ang 100 feet chord to another 100 feet, that makes 200 feet. Mahitabo ni ingon niine kay each average user needs an educations, ug karon maayo ni imong presentation Bay Froi. Keep up the good works and more educational presentations. From Leyte.
Salamat sa comment Bai...it helps a lot of information...God blesss 🙏
Ano po difference ng #12. And #14 sa #8, mas mataas po ang number mas makapal po wire, gnun po ba, pano po ba un? Salamat po.
@@WhateverDailyVlog size lady, size of the wires. The smaller the numbers the bigger the wire is, and do the opposite.
Nagpagawa sakin un jowa ko na teacher, ganyan gnamit ko kasi sa school nya gnagamit and medyo clumsy xa. And matibay un material nyan. Also with child safety din.
Salamat sir buddyfroi sa mga tips.
You're always welcome Lods!
Thanks buddy froi s tutorial mo god bless.
You're very welcome Lods!
Nice nice sir buddyfroi watching gagawa din ako nyan pang heavyduty na extension wire😊
God bless Lodz...
Nice bagong info.👍👍👍
Godbless Lods!
Thanks for your video ❤
You're very welcome Lods...
Tamang tama Po kayo dalawang plug na nabili ko kaso na mapasok ang wire
nice tutorial..👍👍👍👍👍
Thank you Lodz!
Great explaining
Salamt Lods! God bless...
Onother good idea lodi agad agad ganyan na gagawin ko sa mga extension galing mo talaga idol tnks sa lahat ng na share mo.
God bless Lods!...cg sa next video....ty
Pa shoutout naman lodi sa next video nio Jojo Rabo from Mandaluyong City..
Sure cg Lods sa next video....ty
Salamat ser may ganyan po ako at hindi ko na install nung dikopa to napanood
God bless Lodz...
Claro lods tnx.
God bless Lodz....ty
Thank you idol
You're very welcome dol 😊
kahit ako mas gusto ko ung brand na omni...kesa sa iba ..ung extension cord ko na gamit ..omni xa . nsa 500+ ung bili ko ..hangang ngayon good pa ...
God bless Lods!
Salamat Sir
You're very welcome Lods!
May tip din po kung paano maging tama yung pag identity ng line at neutral sa flatcord
Kailangan nyong gumamit ng multi-tester Lods para may indicator kayo sa linya na yon ang para sa neutral....ty
I mean yung guhit po sa gilid ng flatcord, madali niyo din madisguish kung ano po yung line and neutral
Share ko lang po, maganda din po bumili ng extension sa deeco, may nakita ako isang heavy duty extension na gawa nila na naka no. 14 royal cord worth php700 to php900+ anim na din po saksakan
Thanks Lodi...
Welcome Lods! 😊
sir,pwede nio po ako igawaan ng video tutorial para po sa tamang plug ng charger ng cp po.tulad din po ba yan ng male plug na may ampers.salamat po.
Cg Lods subokan nyo d2 sa Link para madali nyong magaya...ty
ruclips.net/video/hOMM8MXPv0Y/видео.html
First ulet Sir 🤗😉
Well done Lods! 🙏
Nice nong buddy...pwede kaya yan sa welding machine ung inverter portable?
Pwedeng-pwede Lods!
Importante yang ground connection. Sa ibang bansa, mandatory yan. Ewan ko ba kung bakit hindi gawing batas na ang mga bagong construction na bahay ay mandatory na yang may mga ground wire sa Pilipinas. Lalo pa na 220v dito.
Good day buddy froi ..maganda sir yun plier mo ano brand yan sir at saan mo inorder. Keep safe sir buddy godbless
Cg Lods ilagay ko nalang ang Link d2 kung saan natin nabili....ty
invl.io/clij3h2
@@Buddyfroi23 salamat sir buddy.
Gnyan gmit q na outlet Sir ung pinaka heavy duty ng Omni, natesting q sa skul nmin nun sa portable welding machine nakisaksak ung mga gumagawa ng d nagpaalam buti hnd nasunog kaya alam q na matibay 😁
God bless Lods 😂
There is no such things as heavy duty, the thick and the thin, the long and the short wires always follow the Ohm’s Law. Doesn’t mean heavy duty wires you can connect more than the wires amperage capacity to 80%, the 20 % remaining amp is for for expansion when the the wire itself heats up due to equipments and lighting start up, the inrush current together with the proper size breaker. We have more equipment where i worked as HVAC/R, our 300 tons chiller VFD wirings had a exhaust fans and being cooled off by a chilled water. That’s how the wiring protected specially some enclosed spaces, yes the wire on this humongous chiller are properly designed as we called it “Heavy Duty”, the problem the name heavy duty is just a labeled without extra protections cooling this wirings melted due to the hot enclosed spaces and inrush current from the amperage draw from the equipment. Is it heavy duty like a commercial grade wire better than the commonly household wire are better, yes, on the house wiring if you have a small shop like my Fave Bay Buddy Froi, have to have a good size wiring and he knows that. Sa school nyo nakisaksak iba sa welding machine at buti nalang hindi nasunog, guess what features protect the wiring when overloading happened…the breaker. Could be the breaker tripped and open up that cut the power, the other things kong malaki-laki ang amperage sa breaker everything toasted. Now the person asked someone on the shop knows about the amperage of the breaker or the shop people knows itself, this is what we called an Innocent mistakes and causes property damages. Now we take take advantage of Buddy Froi very detail and professional presentations although some of the details wasn’t there but the most specs and info tells us what to do. So don’t get mistakes with the label Heavy Duty because the Ohm’s Law dictates the wirings protections. Daghang Salamat, from Leyte.
salamat buddy froi sunod napod vlog nimo lods
Welcome Lods! God bless....
Pwede po ang 14guage wire sa 1hp vespa aircompressor
Mas safe Lodz kung naka #12awg ang guage wire...
Nice
Welcome Lods!
Wow,maybago na pala na extension heavy duty talaga.Sending full support from mhemee vlog,Pasuporta po,Salamat 😊
Welcome Lods...
Sir pwde ba sa 300amp na welding machine ang 16 royal cord
Naku! hindi pwede Lods, dapat naka #10awg pataas lalo na kung hindi naka inverter ang welding machine....ty
Pwd n po b size 14 n wire s mga portable at maliit n welding machine sir? Personal use lng poung portble weldng mchine po
Mas safe Lodz kung naka #12awg ang flat cord para hindi madaling uminit...ty
Share ko lang po, para madistinguish po yung line and neutral sa flatcord, yung neutral po ay may mga ridges yung side then yung hot wire po plain lang po yung side, napanood ko lang po sa vlog ng mga foreign electricians
Ang foreign talaga naka line to Neutral compare sa atin na naka line to line....ty
@@poyim256 to avoid confusion have your multimeter ready, things happens sometimes the person and we called it a backyard electricians that doesn’t know between the hot and neutral. With the multimeter you can tell the right polarity, sure light bulbs lit but some appliances have to be in right polarity will be damaged, some multimeter comes with NCV, None Contact Voltage.
Eagle rubber plug Malaki Rin butas non
Pwede rin Lodz...
Sana Lods ginamitan mo ng ferule yung wire. :)
Wala akong available Lods...hehe....ty
ser, nice video po,, saan nu po nbili at anung brand ng tester nu?
Cg Lods paki clik sa Link d2 kung saan natin nabili....ty
invl.io/cliq86v
Idol pwede po ba magtanong kung may video po kyong extension cord para po sa inverter welding machine 300amps or pwede na din po iting gamitin? Salamat po.
Wala pa Lodz...pero kung inverter ang gamit mo pwede lang...pero kung hindi...di yan pwede Lodz sa welding machine....ty
Thank you very much po Idol BuddyFroi23
Hi sir nice video, tanong ko lang po ang household outlet po ba ay line to line? Thanks po
Depende po yan Lodz sa provider nyo dyan...pero dyan sa video naka line to line....ty
@@Buddyfroi23 hello sir metro manila po ko nakatira Meralco provider ano po yun? Line to line?
sir halimbawa gagawa aq na ang gagamitin ung outlet mismo bahay na dalawang 2gang outlet pwede bang ung pangalawang 2gang outlet ay nka tap sa mismong wire na flatcord #12 or 14? para hnd sya octopus connection? kumbaga parang wiring sa bahay kapag dalawang 2gang ang gagamitin gnun style. pwede ba yun sir? yung mgtap sa flat cord wire?
Pwede lang Lodz...Pero mas safe kung naka Pig tale kay sa naka throw in throw ang outlet...
Sir,pwede kaya to sa mga welding machine na may na may capacity na 260a?
Pwede yan Lods kung naka inverter ang welding machine...ty
Yes po ,inverter.Salamat po sir sa sagot!
Lods pano naman po pag royal cord ang ga2mitin...
Pareho lang Lods naka circle lang ang wire hindi naka flat....ty
Sir safe ho ba gamitin tung omni heavy duty outlet na naka intact lang na nakasaksak sa may outlet ginagawa ku ho kasing extension lang ng tv at cignal intact lang ho sa outlet hindi kuna tinatang gal hindi ho ba umiinit yung light indicator nito pdx wire ho ang gamit ko at heavy duty plug salamat po God blessed
Ok lang yan Lodz...ty
Sir , good job po , pwede po ba ganyan heavy duty extension cord , gagawa ako ganyan heavy duty extension cord , about 20 to 25 meters ang haba , hindi ba sya mag-iinit kung sakale , thanks ,
Medyo uminit yan ng kunti Lodz basta hindi ka maglapas sa limit na 2.5kw...although may voltage drop na yan sa layo ng 25mtrs...ty
Hello po sir ..new subscriber nyo po ako ..tanong ko lang po ,pwede po ba isaksak ang refrigerator po na 220v dyan at saksakan din po ng heater?at magcharge ng phone ..sana po masagot ..thank you and Godbless po
Pwede lang Lodz...
Idol tanong lang Po kasi Ang SPD daw maganda ba daw protection para sa kidlat after solar panel daw Kasama Ng circuit breaker Ng SCC. T.y
Opo Lods! 100%
Thank u idol Kasi nakita ko sa online daw maganda Pala protection balak ko lagyan sa akin idol, pero nag tanong ako Muna sayo kung okey ba thank u idol god bless....
Pwede na po ba ito sa inverter welding machine? Gayahin ko nalang hehe
Pwede lang Lods..
Salamat po buti nalang di pa ako nakabili ng heavy duty plug at extension outlet. Pansin ko kasi mas user friendly yung ganitong setup lalo na di mahirap maglagay ng wire sa loob ng extension wire at plug at sigurado na hindi ito madali matangal dahil screw type na at yung feature na pag kakapitan ng wire na may goma is super ayos talaga sigurado na hindi mag lo loose yung wire sa loob @@Buddyfroi23
Sir kaya ba Yan ng 4gang sabay2x apat na sewing hi-speed machine,,salamat sa sagot poh,,,
Hindi na safe Lodz kung sabay-sabay sa 4gang dapat sa 2gang lang para safe...
Sir pwede b sa aircon yan 1/2 HP lang 2.4 Running Amps. sa nameplate.?
Pwedeng-pwede Lodz...
@@Buddyfroi23 hello sir pwede ba yan sa aircon na 1hp non inverter?
Pwede din po kaya yan sa welding machine na 200 ampere?
Pwede Lods kung naka inverter ang gamit nyo....ty
idol pwd b jan i flug ang power amplifier ....
Pwedeng-pwede Lods!
idol buddyfroi. tanung kolang po kung ilang amper sircuit braker. ang pweding ikabit sa electric motor na 5hp. salamat po god bless🙏🏻
30amp na Breaker Lods!....ty
@@Buddyfroi23 thank u idol
sir pano mag branch breaker sa line to ground.
Cg Lods paki clik sa Link d2....ty
ruclips.net/video/IVvhPBExIH8/видео.html
Ano po tawag sa pang roll ng wire sabihin ko kasi sa hardware para may extra sila na e tatapon na. salamat po
Spoll Lods hehe....ty
sir anung gamit mong tester?
Bside A1 Lodz...cg para makita paki clik d2.....invl.io/cliq86v
pwde ba yan gamitin sa inverter welding machine bos?
Pwede lang Lodz...
hello po sir... may binili ako portable IGBT inverter welding machine na 300amps., gamit lang sa bahay pang project.. anu pong size ng wire extension dapat Kung gagamitin? salamat po sir and god bless...
Pwede na dyan Lodz ang #12awg flat cord....ty
Idol Buddyfroi ask ko lng po.. ano pong wire at ano pong size ng wire ginagamit sa street lights.?
Naka #10awg Lods...stranded wire thhn....ty
@@Buddyfroi23idol pwede rin bang gamitin ung duplex wire/service drop Kasi medyo may kahaban Kasi ung Street light na gagawin...
San nyu po nabili un plier nyu na may striper.??
Cg Lods paki clik sa Link d2 kung saan natin nabili....ty
invl.io/clij3h2
Pwede po kaya yan sir sa 0.5hp na aircon
Pwede lang Lodz...
Ask po lodi, if size 14 or 16 pwede po ba para sa heavy duty na extension outlet?
Yong #14awg Lods pwede pa yon...pero yong #16awg hindi na safe para sa heavy duty na outlet...ty
@@Buddyfroi23 thank you lods.
Sir pwede po ba gamitin yan pra sa tv,electric fun at pag charge ng cp po.
Pwedeng-pwede Lods....ty
Boss pwede po ba yung 2.0 mm^2 sa wire? Pang charge lang ng ebike
Pwede lang Lodz...
Pwede po ba ang #16 na wire sa mga power tools gaya ng impact drill at grinder?
Pag ganyan mas safe kung naka #12 ang flat cord...
Maganda ang video. Buddyfroi, di ba 20amp ung male plug pero yung Outlet 15amp, di ba yan magkaka-problema dahil hindi sila magka-parehas?
Hindi yan magka problema Lodz...doon ka mag basi sa pinakamaliit na rated ampere...ty
@@Buddyfroi23 that’s what we called a very professional answer from certified and qualified electricians like Buddy Froi, in case of doubts dealing with electricity called a professional.
Sir buddy froi pagilagay ko sa 80amp current ang inverter welding machine mga ilang wattage kaya yun?
Depende yan Lods kung naka full wave or spot lang...mas maganda kung meron kang clamp meter para makita mo yong actual current sa input....ty
Sabihin nalang po natin naka full wave at ilan naman pag sa spot lang. Pasensya na po dami kung tanong HAHA dumating na kasi yung inverter welding machine ko nasa safety first research ako ngayon hehe @@Buddyfroi23
@@Buddyfroi23 Sadly yung nabili kung inverter welding machine na yamato ang brand ay hindi gumagana working naman yung unit pero hindi maka penetrate in short walang arc sa bakal pag e dikit yung welding rod. Malaki pa naman nagastos ko sa heavy duty extension wire almost 700+ tapos yung result ay nakaka lungkot..
@@ritznoblejas3617 Baka walang ground yong bakal Lods kaya hindi naka penetrate check nyo muna....ty
@@Buddyfroi23 Nag research naman po ako lahat ng pwede dapat gawin sa pag gamit ng welding machine. Sadly defective po talaga...
Lods, paano po yung extension wire pag sa Welding Machine na 400amps?
Naka direct na talaga ang wire doon Lodz sa welding machine sa circuit Breaker...
Good day po sir. Tanong lang po pwede po ba pagdugtungin ang #10 to #6 ang wire? Salamat po..
Pwede lang Lods...pero yong #10 ang masusunod ibig sabihin hanggang 30amp Breaker lang ang pwedeng gamitin....ty
Pwede po ba sa induction cooker. Aabot kasi sa 3500 watts ang high power niya
Hindi na kaya Lodz iinit na yong wire...mabuti dyan eh direct muna sa Breaker...
Pwede po b yan gamitin wall outlet gamit ang #14 solid wire o #14 THNN Electrical wire sana po mapansin malaking tulong po sa akin ang pag reply ninyo
Mas safe Lodz kung naka #12 ang wire pag dating sa outlet...Optional yang #14 kung para lang sa electric fan at charger....ty
Thanks po
Ay sir gamitin ko lang po sana yan sa ceramic cooker na 3500 watts
@@ErminildaMerlan Naku Lodz! patay sunog ang #14awg dyan...Dapat naka #10awg ang size sa wire kung naka 3.5kw ang cooker....ty
Ay maraming thank you po
Ser un po ba ng spd dc o ac po ang gagamitin ko para hindi po maka ground tnx po
Kung para sa solar yong Dc...pero kung para sa Ac yong Ac din....ty
Salamat po ser
Sir yung royal cord po na heavy duty #18/2 kaya po ba ang ref salamat
Kung maliit lang ang Ref...
sir balak ko is diba meron nako nakalagay na outlet sa bandang likod then nakasaksak na lahat don ung mga pc, speaker, monitor, ilaw. Then ung wire non is dadaan sya sa switch na yan then sa line 1 and line 3 ko ilalagay then mag tatap ako ulit ng wire na may socket na sya then ilalagay sa line 1 and 3 then para pag naka switch off walang pumapasok na kuryente patungo sa outlet na nakasaksak.
Yung outlet is royu na may 3 socket. Then wire ko size is 16. Ang di ko alam kung ilang amp kailangan ko na switch para mas okay kung 10a or 15a or 30a
Yong 15amp rated na switch gamitin mo Lods!
@@Buddyfroi23 meron kapong available email or message para mapakita kopo ung example ng layout?
Sir, advisable po ba na gumawa ng extension cord na madaming outlet para Isang linya lng Ang saksakan para sa aming sound system para Hindi madaming extension wire ang gamitin. Parang bawat 3meter my outlet
Sa heavy equipment na gamit Lods, 2gang extension outlet ang advisable...sa 4gang extension outlet mabuti lang yan sa mababang wattage na gamit...although naka design naman ang outlet sa 15amp ang rated...ty
Mas mainam na gumamit ka ng safety breaker kahit 20amps to 30amps
Sir, may tanong po ako, hanggang ilang meters yung paggawa ng extension bago magkaroong ng wattage drop? Balak ko po kasi gumawa ng 10 to 15 meters na extension gamit ang 12awg na flat cord, for construction purposes lang po
May voltage drop na Lodz kung aabot kana sa 15meters by 3%...
@@Buddyfroi23 thank you sir, binigyan din ako ng stool wire sa DIY Hardware, ayaw ko naman gumamit ng royal cord dahil lumalaban..Kaya 10 meters na lang gagawin kong extension outlet
@@Buddyfroi23 pero kaya pa din ba ng welding machine yung paggawa ng gate at yung gutter sa roofing?
Lodi saan nio nabili ang pliers nio na may pang splice maganda gamitin kc ang ganyan kompleto na tsaka magkano pala ang bili nio? Tnks..
Cg Lods paki clik sa Link d2 kung saan natin nabili....ty
invol.co/clij22j
Buddyfroi San Po ba applicable gamitin Ang # 16 na flat cord wire kasi dito Po saamin na pansin kopo kasi #16 Ang Gina gawang extension wire pwedi poba Yun?? Sana mapansin pang dagdag kolang sa kaalaman ko
Mabuti lang Lodz ang #16 kung pang charge sa cellphone, electric fan at ilaw...Pero kung electric drill or Grider mas safe kung naka #14 or #12....
@@Buddyfroi23 ok salamat sa sagot mo buddy froi 👍👍
Sir sa pagpili ng wire mas maganda po ba ang gauge na mas mataas? Para heavy duty sya ? Newbie
Opo Lodz mas maganda kung may kalakihan ang wire...
@@Buddyfroi23 salamat po Sir
Mas heavy duty ba pag #10/2 ang gagamitin? Para sa power tools
Opo Lodz....kaya lang walang ng #10 sa flat cord hanggang #12 lang sa PDX meron hehe....ty
@@Buddyfroi23 kaya po jaya ng 12 ang table saw at ano kaya maximum watts na kaya ng heavy duty extension na gawa niyo?
@@Buddyfroi23 yung table saw po 2500 watts, kakayanin kaya nitong heavy duty extension cord?
@@michaelbejosano8570 Medyo iinit ang outlet dyan Lodz...
@@michaelbejosano8570 Kung #12awg na flat cord kaya dyan...
sir paano maglagay ng protection sa extension outlet para hnd masunog at anung device ilalagay at paano po?
Lagyan nyo nalang Lodz ng circuit Breaker o kaya fuse type...cg gawan natin ng video....ty
@@Buddyfroi23 gagawa po kasi ko dis week sir. wla ko masyadong makita na upload sa youtube na tutorial eh
@@Buddyfroi23 yung kusa sana ma cut ang line pag makakasunog na yung init
Boss..ask ko lng..patay sindi kuryente s amin..ask ko if ok ba gumamit ng Panther power delay para sa ref at AC? Totoo ba nkakatulong un?
Opo Lodz para hindi madaling masira ang mga appliances...
Sir pwede nb yan pra gawin extension pra sa welding machine 300amp db masusunog yan ...sna masagot ni ser nka subscrbe aq sau😊
Pwede Lods...kung naka inverter yong welding machine...Pero kung hindi yong maliliit lang na welding machine ang pwede po dyan....ty
@@Buddyfroi23 sir ung 300 amp nga po pwede ba yun sir
@@chays8725 Pwede Lods basta naka inverter ang welding machine....ty
@@Buddyfroi23 slmat din po ..sir isa png tanung po ..kaya pb palakasin ung ordinary na dril ..kya pb plakasin un ..ngfollow kc aq sa yt nyo
@@chays8725 Pwede nyong gamitin yan Lods...pero wag nyong sabayx2 gamitin...ty
Pwede kaya to sa oven sir? Or microwave oven??
Pwede lang Lodz basta hindi lalagpas sa 2.7kw ang Oven...
Good day! Wala po bang magiging problema kahit 20A ang ginamit na plug? At ang extension outlet is 15A lang? Hindi po ba mas maganda if parehas 15A ang gamitin na plug sa 15A na extension outlet? Sana po masagot
Walang problem Lodz...mas advantage lang mataas ang male plug para hindi madaling uminit...
@@Buddyfroi23 salamat po sir!
Nakabili na ko nito gagamitin ko sana extension for sound equipment. Pwede po ba 10 amp na male plug or need kahit Yung Omni na 15 amp plug?
@@michaeldesiderio8563 Dapat yong omni 15amp ang gamitin mo Lodz para safe..
ok lang po ba gumamit ng 10 amp na male plug, 10 amp na surface outlet at 14 gauge wire kapag gagawan ng extension??
Pwede lang Lodz...
Kapag 16 gauge wire po? Kaya po ba nito ang powered mixer at amplifier speaker? Pero hindi po pagsasabayin. Isa isa lang ang saksak
@@jhonnelbaque2597 hindi na safe Lodz ang 16 gauge dapat naka 12 gauge...
Where can i buy that flat? cord
Cg sir paki clik sa Link d2...ty
invol.co/cljd3b0
Safe na po ba kahit anong isaksak jan na appliances or gamit po? Or dapat po hanggang 3750 watts lang po bale ung dapat ng total?
Opo Lodz...3750x80%=3000w ang pinaka safety gamitin hehe....ty
Safe po sya saksakan ng appliances basta hindi po lalagpas ng 3750 watts,
Kahit 65 watts pwede po
Good day idol Tanong ko lng Po may welding machine Po ako 300 amps ilang amps Po sa main breaker.may naka install na Po 2 breaker na 15amps at 3 na breaker na 20amps tapos yong main breaker ko Po 80amps. ngayon magdagdag ako Ng breaker para sa welding machine idol baguhin ko pa ba Ang main breaker at ilang ampere Po para sa welding machine.. Salamat idol
Pwede na yan Lods ang 80amp na Main Breaker..eh dagx2 mo nlang dyan ang 50amp na Breaker na para sa welding machine mo....ty
@@Buddyfroi23 salamat idol and good morning po
pano malaman kung line to line o line to neutral nilagay sa bahay
Pag parehong naka coated insulation ang dalawang wire talagang naka line to line pag isang wire lang ang may coated sa kabila wala at naka aluminum wire yon ang line to neutral...
Royal cord na 3/C dapat dyn
Opo Lods...mahal kasi ang royal hehe....ty
Sir ano po brand ng flat cord mo? Wiremax po kasi nabili ko sobrang kapal insulation ng flat cord ko kaya hirap ibalik yung fix plate
Pareho tayo Lods wiremax...😊
Thanks lods, baka mag royal cord na lang ako na 12/2. Hehe
@@poyim256 Ang mahal kasi Lods ng bawat meter sa royal cord compare sa flat cord...pero mas matibay gamitin ang royal cord hehe....ty
Yes po lods, php30 yung deperensya nila, pero same pa din sila ampere at usage na pwede gamitin