Ilang Outlet Sa 30A Circuit Breaker
HTML-код
- Опубликовано: 15 дек 2019
- Sa video na ito ituturo ko sa inyo ang tamang computation pano malaman kung ilang outlet sa 30 amps na circuit breaker
Also visit my FB pages and group:
JB Online Shop
✓you can buy product such as Electrical devices mostly on industrial devices
/ jb-online-shop-8428213...
Jun Aux TV
✓all about Electrical installation and Electrical devices reviews and safety awareness on Electrical
/ jun-aux-tv-20510673918...
JB Handyman Services
✓If you’re looking for the right person to fix the problem you're facing in your home you can find it here, License Electrical Practitioner is available here, visit us
/ jb-handyman-services-4...
Electrician For Hire
✓group of Electrician looking for a job and giving and taking ideas in one another
/ 598549563632057
If you enjoy watching this video don't forget to subscribe, like and hit notification bell thank you!
Electrical wiring connection
Electrical wiring installation
Electrical devices tutorial
Power tools review
Hand tools review
New electrical devices
Thanks for Watching hope you enjoy. God bless
Nice master. Klarong klaro ang explanation. Sana. Mag upload kpa ng marami topic tungkol sa electrical. Marami ka natutulungan. Kudos sau. Master.
Galing idol thank u sa pag share Ng iyung kalaaman na binahagi bilang isang electrician.
Ser. Dag dag kaalaman.salamat for sharing ur knowledge
Going to watch your lectures everyday.
Date:
Ayos na ayos bossing,maraming salamat👍👍👍❤❤❤
So informative..thanks
Thanks for the info..☺️
San po b puedeng bumili ng mounting screw for circuit breaker d2 s Pinas?
Unang,una,,present,,Good job sir Jun,,
Yown....tnx sir...
Boss, ayos yun explaination mo pero ang napansin ko lang hindi kailangan 30amp na breaker ang gagamitin mo depende yan sa outlet na install mo bilangin mo outlet na install mo para yan ang reference mo kung ilan ampere breaker ggamitin mo separate jan ang motorized na appliances kagaya ng ACU or electric range. Nag dedepende kc yan din sa wattage na ma consume dun ka mag base sa PEC standard kc yan din ang point of reference ntin. Pasensya kana kung kailangan kong sabihin sayo na wag kang mag depende sa ampere sa kailangan na wattage ka magdepend base dun sa PEC standard bago mo compute. Pansin mo yun mga appliances may specification dun mo mkikta na kung ilan wattage ang capacity nya isa din yan sa reference ntin para sa computation ng loads. Kya nga gaya ng sabi mo may safety factor tyo tinatawag base sa PEC standard. Salamat sa pang unawa.
Sir may tnong ako. Meron pong existing 30amp CB sa panel board mmin intended pra sa .5hp na aircon. Ang tnong po is, kung pwde po ba kmuha din ng supply don sa 30amp CB pra sa isang 2gang outlet at isang lightbulb lng po??
sir pwede po ba gamitin 2.0mm2 na THHN 90 degree para sa 20/25 Amp breaker
sir ask ko pwede bang gamitin yun dc breaker sa haus .tnx
Sir ano po ba advisable single breaker n 30A or 2 Branch panel sa maliit n bahay n my 2 rooms at isang maliit n kitchen at living room.
Sir, pwd magtanong kung ano ang Common n breaker n ikabit s bahay n maraming appliances thanks.
good day sir. pwde bang mag connect ng 30amp. na breaker sa refrigerator at may t.v pwde bah..!!
Good day po master, salamat po,if masasagot.master tanong kulang po kung dapat pobang lang yang ng tag iisang cb .ang mga ref,.12pong piraso ang kakabit kupo,. salamat po
Sir new. Subs. Po ako.. Ask ko lng pwd ba isaksak jan ang inverter welding machine?
Sir puede bang mag install ng combinition line to line at saka line to neuatral tapos mag install ng 110v sa outlet
Sir tanong ko po ilang amperes po ng main breaker ang puedeng ilagay sa 5 na 20 amperes branches breaker? salamat po
Good day boss ask ko lang ung isang outlet with 2 gang each socket ilan appliance pede I connect .usually ginagawa.ntin isang outlet connect ntin extension wire with 6 socket then connect tv.home theater subwoofer and DVD player ?? Ok lang ba yun .or mas safe isang outlet connect ko automatic voltage regulator then connect extension wire with 6 socket jan ko connect ung tv home theater subwoofer etch.
Sir pwd bng gumamit ng 12 size n wire sa metro patungo sa panel box ung kc ang gamit q .
Nice po sir mi natutunan naman po ako..tnx sa tutorial po.. sir ask ko lng mi nakapag sabi po kasi sakin yung mi bagong rules na daw po yung mga electrical company na bawal na daw po mag instal kahit sa bahay lng yung mga nc2 at vocational sa electrical pag walang lisensya. dpat daw rme. tutuo po ba yun sir? kakalungkot naman.
Pwd sir kailangan lang supervise kayo ng may license kaso hindi nasusunod yan sir..
Good morning ser pwede dw po ba pagsabyin ang wire na no.12 at 10 sa 30amps breaker
Sir new sub here. Ask ko lang po based sa video niyo po. Gamit po sa bahay namin is 30 Amp - 12awg for 13 C.O. Ayos lang po ba ito sir? Thank you!
Sir anu dapat po gamitin 20A o 30A na CB may 1hp aircon at 4 convenience outlet tnx po..
hi sir baguhan lang po ako sa electrical system design. tanong ko lang po how come na pwede tayo magplug ng 400 W na appliance like rice cooker kung ang max per outlet natin ay 180VA lang po
Bro ask lang Yung nabili Kong RCCB 40 amps 50 Hz puede ba syang magamit ?
Sir pwede po ba 30amp ang main CB, tapos kabitan ko ng 30 amp ulit para sa 2 outlet ng power tools, at 20 amp para sa 4 na ilaw at 3 convenience outlet?
Sir sa 20 amps breaker na may 8 gangs pwede po vha i direct ang aircon na 0.5 HP sa Gang oh gagawa pa ng single breaker para sa aircon?
sir sakto po ba yang 30amp sa apat na two gang outlet tapos 3 ilaw( 2 bulb light isang fluorescent light) isang 3 gang switch. mga appliances po ay 2 computer isang 1.5hp na aircon isang maliit na ref tapos electric fan tapos tv.
Sir ask LNG po if pwd ikabit ang single MCB direkta sa pader?
boss gumamit ako ng single breaker 30 ampere kakayanin b Kung 8 outlet at 10 lights?asap po boss.
good evening boss..
ref and aircon technician po ako boss, minsan nag iinstall po ako ng inverter type ac nilalagyan ko po ung ng bukod cbreaker na 20amps, pero nka tap lang din po sa malapit na outlet po. d po ba un masama sir?
advice naman po sir kung ano gagawin kong install wiring kung mali po ung minsang ginagawa ko po sir..
or panu ko po un itatap sa panel po .. salamat po..
godbless
Thanks papz
sir,sa apat na brances a20A at dalawang 15A ano ang pweding main breaker na gagamitin.
Thanks very educational sir more videos to come
Maraming salamat po sir
Sir ask ko lng kapag ang load ay continues dito lng nirerequired ang safety factor or demand factor tama ho ba ako tnx sir
good day sir. if i have a 30A circuit breaker how many outlet can we apply
Boss Yong para SA outlet na breaker ang ginamit Namin at 30 amp pwidi ko ba saksakan ng ref Bali rated power input 140 watts rated current 1.0 A
Pwedi bang gawing homerun ung flatcord
Sir, 30amp po gamit ko na breaker pra sa c.o ko.. ok lng po ba ung size 12 na wire? May 2 aircon po aq tas 10 na c.o
Pwd ba gamiting sa Bahay Kubo ung 15A para sa outlet at ung wire #12
Tanung ko lng po , pwd ba ang 30 amp's sa 8 malaking frezer sa 3 co gamit na wire e 3.5
sir pwde ba ako gumamit ng 32amp.breaker taz #10 thhn wire para C.O? 14pcs C.O lahat two storey kc ang bahay balak ko isang breaker nlng sa lahat ng C.O.salamat
Sir pwede na.po ba 30ampers ang circuit breaker tapos dalawang 1.5 hp na aircon at isang 1.5 hp na water pump .tapos ang wire na gagamitin ko duplex number10 ang main at..at galing sa mga motor na wire ang gagamitin ko duplex number12 na wire un ang idugtong ko sa main na duplex number10
Kaya b 30ampers pag maglagay ng 3,outlet tas washing machine tv electricpan
Sir jun tanong ko lng po,itong bahay po namin ang gamit po namin ay ref,computer,tv at mga electric fan,ilang amper po ba ng breaker ang dapat kong gamitin?at anong wire gamitin?
Pwede po bang 3 c.o at 3 ilaw mag kksama sa 30a na breaker bukod naman daw sila ng wire ilaw ilaw lang co c.o lang ...isang breaker sa main tapos breaker para sa room ko..
Boss pwd po ba size 14 at 12 thhn para 30amps breaker?
Sir tanong ko lang ilang amp.puede ko gamitin sa main breaker papunta sa breaker ng switch at outlet.tnx po God bless
Sir, nka RCBO po Yung breaker ko, 32amp. Pwde po sa 3.5mm² #12 , at Kya po Kya nya Ang ref ska washing...
hello po, pag sa refrigerator po ba dapat may circuit breaker rin?
Pero ung thhn na 90'c na wire... Ok lng din na gamitin sa 20amp para sa aircon o kya sa mga outlet?
Sir yung ngang 3 phase installation ang next tutorial mo...salamat
Soon sir...
sir okay lang po ba na ang refrigerator at washing machine namin ay isang outlet lang pero may dedicated na circuit breaker at ilang amperes po kaya ang need?
Boss ilang amp, ang kaylangan kung meron ako repidjarator at tatlong outlet,
Idol tanong lang ulit ..yun breaker ko kasi ang nakalagay (sh 202 C20 -400v 6000 3) ang nakalagay sakanya na outlet for washing at ref daw.pwede paba ako magdagdag isa pang saksakan?na may kasama linya para sa ilaw?tyka isa pa tanong dati naka bulb ako sa sala pinalitan ko ng led pero naka dim kahit patay na sa switch hindi naman sira led kasi tinry ko isaksak lang okay naman sya pag nag switch off ako hindi naman glowing pag sa outlet sya naka direct ang ngyyre tuloy pinapatay ko sa breaker ilaw sa umaga halos araw araw para lang di naka glow yun led light okay lang ba yun araw araw off yun breaker 😅 salamat ng marami
kung mag dagdag ba para sa tv.ref.electrifan..ilang amp ang dapat jan?
Sir ung kuryente s kwrto pbgo bgo ang supply.mdlas kc mhina kuryente pg umaga.kht nka todo ung fan prng no.1 lng.kpg mdaling arw npaka lakas n ng fan nmin.
2:34 Doon sa Chart po ninyo na sizing wire and circuit breaker, yung 30A 5.5 po nakalagay don ngayon 3.5 na?
Pwede ba #10 na wire na thhn?
Sir pa explain naman po nung for further expansion? Bakit ganyan??
Boss ano ba ang rating ng mga outlet na ilagay mo dyan. Kasi sa PEC table 2.10.2.4 (B) kun 30A ang CB rating, ang outlet din ay 30A rating. Kilangan match ang rating. Kun regular outlet ilagay mo mababa ang rating nun tapos lagyan mo ng 5.5 mm2 .
Sir pano po kung wala ilaw or brown out, eh myron ako generator pano po mag install?
Boss pwede ba ang 25 amper circuit breaker sa ilaw?
good morning sir jun. sa 30amps pwede nba pag smahin ang c.o at lighting outlet? and with separate wire na sa c.o 12duplexwire at 14duplex sa lighting? Single circuitbreaker lng po ggamitin q.
sir ganto po ang purpose ng cb natin protection po sa wire kaya hindi tayo pwdng bumaba pa ng size ng wire sa 3.5mm yan lng po ang may allowable na ampacity na pasok sa 30a
ang #12 duplexwire sir is hanggang 20a lang po yan...
sir tungkol naman sa high in low ang koryente paano magawaan nang paraan para permis ang koryente
Bro nkakabili b ng analog multi tester at magkano po
Sir ilang cb po ba kailangan kapag mayron ref, frezzer,washing machine, flat screen na tv,rice cooker,electric fan.7 lights.salamat poh
Pwd na po 6 branches jan mam..
Boss kaya ba nang 20a ang aircon at ref?
kung dalawang ilaw tapos isang saksakan po..30amp ba ang gagamitin?
Sir ask ko lng po kung tama set up ng circuit breaker ko.
Main 60A
Outlet 30A #12 with additional extention cord.
Heater 30A #10
Switch 30A #14
Aircon 1.5 hp 30A #10
Thanks po. Stay safe. GOD Bless 🙏
sir pag 30 amps breaker ang ginamit sa 3.5 thhn wire para sa mga outlet. Pag nag short circuit sunog lahat ang mga outlet hindi.pa mag ti-trip ang breaker. pero ung wire hindi masusunog maliban sa jumper ng outlet.
Sir good evening po. Bago lang po ako sa channel mo. May tatanong lang po ako kung ok po ba yung #12 wire tapos main is 30amp may 9 na ilaw at may 6C.O at may ref ok po ba na i plug yung reff sa co? Single CB lang po siya
kaya yan sir kahit 20a lang para mas safe po
Sa 30amp Po ba kaya ba ang 1 ref for cold drinks at 2 na cheller for frozen food. Isang breaker lang Po gagamitin ko 30amp? Thanks
Ang aircon ko po ay .5hp...yung computation ng breaker ko is 11A ocpd..tama ba po?
Boss ilang freezer appliances Ang Kaya nang 30 amp?
Brad paano ba malaman natin na nag karuon Ng voltage drop @ anung tools Ang gamitin para sa check ? Kung nag karuon Ng voltage drop.
Sir ask ko lng if di ba natin macompromise ang safety natin dyan considering na Ang maximum capacity ng outlet natin is 20A?yang sa video photo mo sir ay 3 prong outlet, can I ask the ampacity ng outlet mo kasi parang di mo ata nasali ang capacity ng outlet na usually gamit natin... Thank u po.
Pano po sir kung may 10 pcs two gang switch pwede pa ba mag dagdag ng 8 ilaw na tig 20 watts ?? Salamat po kung masagot man itong tanonng ko ..
Ang importante sir hindi ka lalampas ng 12amps computed load sa 15 amps na cb sir
Boss pwede ba isang 40 amp na circuit breaker para sa lahat ng outlets, ex 6 na 3 gang bale 18 outlets pwede ba yun o kelangan talaga hatiin sa dalawang tag 20 amp circuit...TIA
Individual mo na Lang master para hinde mahirapan mag trip breaker mo pag my short circuit
Ilang c.o sa 30 ampheres , 20 amperes May 3 gang, kasi kong 2 gang lang ma gamit ang 2 maaring overload kong 3 gang di overload kasi open, sana na itindihan mo ang aking tanong salamat
so its not safe a 30amps circuit breaker for refrigerator (inverter, 6 cu ft), washing machine, rice cooker and flat iron tanong lang po can i utilize one appliances at a time, like washing machine naka switch off ang rice, cooker, flat iron at ref?
FYR lang po Sir. According to NEC, ibig sabihin po ng 180VA per outlet does'nt mean per single outlet only. Ibig sabihin po sa NEC ay 180VA per yoke mapa simplex man duplex o triplex receptacle. And magbabago lang sya kung multiple device consisting of 4 or more receptacles per yoke equivalent to 90VA per receptacle na sya. 😊
yan din ang alam ko sir dati na per yoke(metal/plastic holder ng outlet) ang bilang hindi per outlet but mas safer kung gagamitin natin is per outlet may nakausap din akong engr. same we both agreed
@@junauxtv I was just telling the real value of dupex, triplex, and single receptacle outlet which is 180VA. :) , if yan po yung pagkakaalam mo dati, yan pa din po un ngayon. :)
Kaya hindi yan ang sinunod ko sir kasi may nabasa ako sa PEC, hanapin ko lng sir... nakalimutan ko lang paano pagkasabi doon...
Yan na nga Po matagal ko na iniisip. Cguro kung sa 180VA mo lang I compute Yun 3 or two gang wala naman kaso. Basta Tama Ang sukat ng wire at breaker. Kc Nung umatend Ako ng seminar. Sa 20A 13 PCs at sa 15A 10pcs na outlet Ang maximum kahit Ilan Gang, per pcs Ang basihan base sa itinuro sa Amin sa seminar. D nman sabay sabAy Gagamitin at iTrip safe nman Basta Tama Ang wire at breaker.
Pede b ung 30 amp s ref lng
Pano kung sampong outlet ng ref ang ilalagay? Gagawin sana testingan lang ok na ba yung 40 amps?
Maiba lng ako sir...kng 30amp ang circuit Breaker ko mga ilang watts ba kaya niyang supplayan ...mga amplifiers lng nmn gagamitan ko
Sir pano yung 2freezer 1 chiller at isang ref pwede ba sa isang 30 amp na breaker yun
May wattage po ba mam na nakalagay?
How about sa switch not included ba sa for 30A circuit breaker?
master ok lng ung l.o pd b 3.5 wire na gagamitin ko pati na din sa swich..at kung ok lng ba ung main ko 60amp at l.o 30 amp at c.o 30 amp....
Mas maganda sir if nasa standard tayo 15A lo 20A co
Jun Aux TV tapos ung main ko is 40.pero pd ko na po b gamitin ung 3.5 sa l.o at swich
Sir ang 180VA po na for each outlet is kahit 1gang, 2 gang sya or 3gang, 180va pa din po yung total va nya.
Sir pwede ba yan sa saksakan ng ref,, at heater
Pwd sir...wag lang masyadong malaking ref
Boss ask ko Lang pwede ba by pass,30amps main breaker
No.14 wire tas nandun na lahat ilaw at outlet
Sabi nila kung itotal mo Yung load Kya naman tsaka yun Lang Kya Ng budget pansamantagal, please reply thanks
Sabi nila sir...but may sinusunod kasi tayo na Philippine electrical code sir...kung mag #14 po kayo sir...15 amps lang ang gagamitin nyong breaker...hindi rin po sya pwdng kabitan ng outlet kasi ang standard size para sa outlet is 20amps #12 na wire...sir sa Electrical safety po lage unahin natin...unsafe po ung sinasabi nyo sir
@@junauxtv sir ask ko lang po
Yung water pump po every time na aandar, Yung ilaw kumukurap po
Anu po Kya Ang problema? thanks...
Sir tanong lang dapat ba naka hiwalay ang outlet ng ref sa bahay
Sir tanong ko lang,pag gumamit ng ref ,washing machine,or ac,kailang ba malaki rin yung wire?or okey na ang 3.5mm?at yung cb nya pwd 20amps lang?
As per PEC po motor loads is minimum 30A na CB, if 30A 5.5 sq. mm. Pero po sa pagkakaalam ko REF and washing machine pwede sa 20A na CB and ACU minimum 30A
Good day po sir so yung 60amp na main breaker pwde na sguro yung #8 basta thhn almost 60 amp naman yung thhh#8
Pwede nga 12
sir tanung ko lang yong main cb ko is 30A CB sa ilaw is15A at dalawang 20A para sa outlet ok lng kaya ang main 30A or 40A na?
kung hindi nmn kalakihan load mo sir pwd na yan...
Sir good morning . tanong ko lang kung pwede ko bang lagyan ng switch yung outlet ng ssaksakan ko ng 1HP n aircon ? pr hindi ko n a unplug yung aircon . sa switch ko n lang cya pptayin.
Breaker talaga master 15A Kasi hinde kaya Ng switch Ang Aircon magkaroon Yan Ng lost contact my possible masira Ang Aircon mo
sir tanong kng po panu po malalaman na ang wire na thhn ay 60° or 90°.? salamat sir
Nakasulat yan sir sa insulation ng wire...
Sir sa apartment po nmain sir 100amp ang main cb at 60amp ang isang cb
Kaya na po ba yun sa 8 kwarto ,
Limang 1.0 aircon