How To Test & Repair Electric Motors (Pool & Sprinkler)

Поделиться
HTML-код
  • Опубликовано: 16 ноя 2024

Комментарии • 93

  • @richardtarpley
    @richardtarpley Год назад +2

    This may be a old video, but it was sure helpful to me! Great job! Straight to the point not 30 minutes of blubber and 5 minutes worth of instructions! Again Great job.😀

    • @electronicsNmore
      @electronicsNmore  Год назад

      Glad to hear Richard! Be sure to check out my wide range of videos and share. Thank you

    • @Pootan_nani
      @Pootan_nani Год назад

      Agreed this is very helpful!

  • @patrickpatton7123
    @patrickpatton7123 4 года назад +5

    I must say you did an excellent job explaining motor function. Thank You for using a portion of your life to benefit others whom you dont know. Great communication skills.

    • @electronicsNmore
      @electronicsNmore  4 года назад

      Thanks Pat! Please share my channel with others, and look over my extensive video playlists below for many other videos of interest to you.
      ruclips.net/user/electronicsnmoreplaylists

  • @electricmotorrepair2605
    @electricmotorrepair2605 4 года назад +1

    This is one of the few youtube videos I have viewed where the person has a true and good understanding of both electrical theory and mechanical aspects of these pumps. You explained well. My only issue is recommending that people should try spinning the shaft to see if motor works as sometimes the windings can go hard down to earth and protective devices are just not there or do not operate. If this is the case and you don't test insulation resistance first, then trying to spin the shaft while energized may just be the last thing they ever do.
    Apart from that, I enjoyed the video and well done.

    • @electronicsNmore
      @electronicsNmore  4 года назад

      Good point. Glad you liked the video, and thanks for the nice comment!

  • @FunnymanJones-zs1yq
    @FunnymanJones-zs1yq 5 месяцев назад +1

    Thank you!!! Not exactly exactly my pump but out of hundreds of videos in my search result you are actually helpful 😭 so much easily understood info!! Thank you ! 🙏 Subscribed!!

    • @electronicsNmore
      @electronicsNmore  5 месяцев назад

      Glad the video helped you! Be sure to check out my extensive video playlist for many other videos of interest to you and share my channel with others. Thank you

  • @billymessimer9854
    @billymessimer9854 6 лет назад +5

    Got to hand it to you , you do a great job explaining the details of this motor. Really appreciate the class it helped me with my above ground pool motor. Thanks again I wish everyone did videos like this. Respectfully, Billy

    • @electronicsNmore
      @electronicsNmore  6 лет назад

      Glad you enjoyed the video! I have a lot of excellent videos on my channel that cover many different subjects, so be sure to check out my extensive video playlists for other videos of interest to you, rate thumbs up, and share my channel with others. Thank You

  • @Penny-f5l
    @Penny-f5l 4 месяца назад +1

    Best teacher ever

  • @tectalabyss
    @tectalabyss 11 лет назад +1

    Thank you for another very useful video. Almost all the motors I worked with were 3 phase 480 volts. Looking forward to your next video.

    • @electronicsNmore
      @electronicsNmore  11 лет назад +1

      Your welcome. I don't think you need a start capacitor for a 3 phase induction motor. The 3 phases create a rotating magnetic field.

    • @tectalabyss
      @tectalabyss 11 лет назад

      electronicsNmore
      You are correct. No run capacitor needed. Really the starter for the 3 phase motor is the most complicated Part, Though once one understand"s it, it's not that bad. Cap banks are used to keep the power factor down.It's a money saver for Big manufacturing plant's. I would like a 100 dollar bill for all the motors I wired over the years. : ) Thank you for the reply

  • @paulpittman362
    @paulpittman362 4 месяца назад

    Thanks for this video! Very informative and helpful. I am having an issue where the motor will start but then shuts off after about 30 seconds and hums. I have replaced the capacitor, terminal board and V switch and still same result. From watching the video, I am now wondering if the problem is a bad run winding or possibly the centrifugal switch? Any ideas or suggestions???

  • @nozynoz
    @nozynoz 11 лет назад +1

    Great video, cheers for the information, basics of the coils and testing.

  • @izzycamaro
    @izzycamaro Год назад +1

    Great job, awesome video thanks a lot. Subscribed.

    • @electronicsNmore
      @electronicsNmore  Год назад

      Glad you like the video! Be sure to check out my extremely wide range of videos and share my Channel with others. Thank you!

  • @frankortolano5886
    @frankortolano5886 Год назад +1

    Excellent video

    • @electronicsNmore
      @electronicsNmore  Год назад

      Glad you liked it Frank! Be sure to look over my extensive video playlists below for many other videos of interest to you, and most importantly take one minute to share a link to my channel with others. Thanks
      ruclips.net/user/electronicsnmoreplaylists

  • @felixmartinez654
    @felixmartinez654 6 лет назад

    Thanks a lot, from Venezuela. Letś start checking with the tester.

    • @electronicsNmore
      @electronicsNmore  6 лет назад

      You're welcome! Be sure to check out my video playlists and share.

  • @southboundtp2067
    @southboundtp2067 7 месяцев назад

    I don't know much about shallow well pumps but I have changed a couple pressure switches(30/50) on my old 1.5hp Gould's J10 until I decided to finally get a new one. I snapped a pic of pressure switch terminals and wiring since both pumps are practically the same. . . recently I noticed whenever pump cuts in it clicks a few times before running.
    Twice the pump stopped running(not breaker trip) but after I flip breaker to off then on again pump runs again.
    I notice my kitchen light slightly flicker whenever new pump cuts in. My old pump never said this. New Gould's J10+ has 120/240v switch, old Gould's J10 was 240v on 2 pole switch. I set new pump to 240v as well.
    I don't know what's going on?

  • @DontjeB
    @DontjeB 6 месяцев назад

    Thank you for taking the time to makes this video. Question: my Hayward .75hp pool pump starts & runs for about 10 seconds, then shuts off (does not trip the breaker). I changed the run capacitor, thinking it was the issue, but the problem persists. Since it does start, I must assume the start capacitor is good (maybe that's naive of me). The motor shaft spins freely. Any insight on what else I should examine?

    • @electronicsNmore
      @electronicsNmore  6 месяцев назад

      Is there a pressure switch installed

    • @DontjeB
      @DontjeB 6 месяцев назад

      @@electronicsNmore
      I do not believe so. The motor is a Century .75hp, part number 7-196335-24. Similar in design, but not an exact replica, to the motor you used in this video. It's about 8 years old, and has had lots of runtime. It might just be tired. I don't mind buying a new motor, but I like to troubleshoot and try to find the root source of issues like this.

  • @oscarmunoz6463
    @oscarmunoz6463 Год назад

    Tengo un motor identico al que muestras en el video pero no tengo los.digramas de conexion para 220v..
    Me puedes ayudar?...gracias

  • @geojor
    @geojor 7 лет назад

    concerning the 2 leads (hot and neutral), is the neutral tied to ground like a service panel in a house? and if so wouldn't there be continuity with the neutral wire and ground with the ohmmeter ? thanks for answer ...

  • @rinu3989
    @rinu3989 4 года назад +1

    Great video, nice and detailed!! I have a question. My pool pump (1.5hp with only a start capacitor, just like the one in this vid) recently started turning off for a few seconds then on again for a few seconds. It will continue to alternate between off and on every 10-30 seconds until I shut it off. I replaced the capacitor because it was the easiest thing to do first, but it didn't fix it. What are the 2 or 3 most likely things that could be wrong in your opinion? Thanks!

    • @electronicsNmore
      @electronicsNmore  4 года назад +1

      Sounds like a faulty motor overload protector, or a faulty winding in the motor.

    • @rinu3989
      @rinu3989 4 года назад

      @@electronicsNmore Thanks, I'll check those!

  • @tawfigsalih5719
    @tawfigsalih5719 7 лет назад

    I searching for this too much times. thnks

    • @electronicsNmore
      @electronicsNmore  7 лет назад

      You're welcome! Be sure to rate thumbs up and share.

  • @dr.jackkhorram4129
    @dr.jackkhorram4129 5 лет назад

    Hello thank you for sharing,I need to ask you How can I secure the shaft so I can get the pump out ,I believe it turns counter clockwise? How can I lock the shaft so it won’t turn? Thanks 🙏

  • @ritchie9030
    @ritchie9030 2 года назад +1

    Fabulous vid

  • @johnkosheluk1041
    @johnkosheluk1041 7 лет назад +1

    good info thank you but is it worth it to go through all that trouble when I can get a new ao Smith motor fore 125.00 brand new great. info

    • @electronicsNmore
      @electronicsNmore  7 лет назад +2

      It's foolish to replace a motor that doesn't need to be replaced.

  • @alchemy1
    @alchemy1 4 года назад

    But you didn't test the red start wire to the other pole ( blue and white)?
    In this sears motor I have the reading you are getting with the black and yellow and red is in mega ohms. The white and blue and red I get the reading you are getting with your wires here.
    I want to hook up to 120V. Do I hook up the black wire to the purple? and supply power to white and yellow with the red to the capacitor and white as common?
    I basically also like to ask what is the reading between all wires for 120/240 V motor coil set up?
    Thank you very much.

    • @electronicsNmore
      @electronicsNmore  4 года назад

      There should be a diagram on the motor showing how to wire it.

  • @alainquesnel4937
    @alainquesnel4937 3 года назад +1

    Wow ! Thank you for your vidéo .
    Usefull informations 👍

    • @electronicsNmore
      @electronicsNmore  3 года назад

      Glad it was helpful! Be sure to rate thumbs up, consider subscribing if you like a wide range of helpful and informative videos, and look over my extensive video playlists below for many other videos of interest to you. Taking one minute to share a link to my channel with others on social networking sites would be greatly appreciated. Thank you!
      ruclips.net/user/electronicsnmoreplaylists

  • @Zeppelinlv2007
    @Zeppelinlv2007 10 лет назад

    Awesome channel. I have a spare 1.5hp 115/230v AC single speed pool pump and will use it for a future water project experiment running 24/7. Problem: it uses too much power for what I need (wastes electricity) and too fast (3500rpms). Is there a something I can add to the motor/circuit to make it draw less current (amps)?

  • @ashrafkarjiker6888
    @ashrafkarjiker6888 2 года назад +1

    I’m looking for videos on rewinding the motor

  • @c-joneslawntree3852
    @c-joneslawntree3852 9 лет назад

    Thanks for a GREAT video, question: IF the THERMAL OVERLOAD SWITCH you identify at 5:00m GOES BAD, will that cause the breaker to trip that feeds the power to the pump? I'm troubleshooting my shallow well above ground Goulds 115/230v irrigation pump (set & used at 115v). I replaced the capacitor already & triple checked timer, breaker & voltage (all is FINE). Or does this situation sound like we have a burned out start winding? NOTE: the motor shaft spins very nicely, no hang up at all. THANK YOU SIR!!!

    • @electronicsNmore
      @electronicsNmore  9 лет назад +2

      +C-Jones Lawn & Tree
      Hi there. The thermal switch will never cause the circuit breaker to trip. If you have full voltage at the motor terminals, then only a faulty capacitor or shorted winding would trip the circuit breaker. You can remove the start capacitor from the motor, tape off the terminals out of the way from moving parts, then power up the motor and CAREFULLY give the shaft a quick spin to see it the motor runs. If it does, then the start wining is shorted out,. You should have discovered that doing the resistance test on the start winding.
      Thanks. Be sure to rate thumbs up and share.

  • @soccercutie2251
    @soccercutie2251 7 лет назад +1

    What is the rating of your capacitor, please ? I have the same motor you are demonstrating and the problem is the capacitor nameplate is gone. I want to buy the correct capaccitor. Thanks

    • @electronicsNmore
      @electronicsNmore  7 лет назад

      You need to look up the motor online for the capacitor specs. Probably a 161-193mfd / 125V.

  • @Naseers1
    @Naseers1 7 лет назад

    Great Video! I have a US Motors 2 Speed motor(EB2977T). The color of the 5 wires is different from the color of the wires shown in your video. They are Red, Orange, violet, blue and white with black stripes. How do I translate these colors to the color of wires shown in your video? Thanks

    • @electronicsNmore
      @electronicsNmore  7 лет назад

      You need to refer to the wiring diagram on your motor. You can take resistance measurements between all the wires to get an idea which lead to the run winding, and which lead to the start winding. Thanks for watching!

  • @nielsbartholdy6204
    @nielsbartholdy6204 8 лет назад

    Hi Great movie i like to know what color weier goes together if i like to hook up to 110 volt
    I have a hayworth 1.5 HP pool pump but i do not have the terminal bloc only all the weiers same coler as your video
    Thanks Niels

    • @electronicsNmore
      @electronicsNmore  8 лет назад

      Look up your model# online. :-)

    • @nielsbartholdy6204
      @nielsbartholdy6204 8 лет назад

      Hi Again I have not found on line how to hook up by color of the weirs online it always say use A1 B2 and other terminal markings i only have all the weier ends coming out of the motor also the ower load and capacitor
      Thanks Niels

    • @electronicsNmore
      @electronicsNmore  8 лет назад

      Niels Bartholdy
      Without a wiring diagram, I wouldn't know. Every motor is different. You need to research your motor model online.

    • @bnhamilton
      @bnhamilton 7 лет назад

      If the motor is supposed to have a terminal block, you may be able to find one on Ebay

  • @ROMEYYOUROCK
    @ROMEYYOUROCK 5 лет назад

    I wonder if you could help me. I know just enough about this stuff not to be able to fix it. I believe I have a bad capacitor. Can I test it without removing it from the pump? Also, don't short it out before testing?

    • @electronicsNmore
      @electronicsNmore  5 лет назад

      If you don't have a capacitor discharge tool, then short the terminals before touching the capacitor. Of course the power is OFF before you touch anything.

    • @electricvision6792
      @electricvision6792 Год назад

      I want the diagram that you explain from it please

  • @atifali4703
    @atifali4703 11 лет назад

    Have you any video how to test capacitor? if you have then please tell me. i did not understand about DMM test of capacitor

    • @electronicsNmore
      @electronicsNmore  11 лет назад

      Refer to my microwave oven parts testing video in my video list. When you place the probes of the DMM (using a 1K ohm range or higher)on the terminals of a DISCHARGED capacitor, the resistance should start out lower, then climb very high.

  • @letsgocamping88
    @letsgocamping88 11 лет назад

    So what dictates the motor direction? I'm used to 3phase. Done very little single phase stuff.
    Good video!

    • @electronicsNmore
      @electronicsNmore  11 лет назад

      The start winding. If you reverse the start winding connection, it should spin the other direction.
      Thanks For Watching!

  • @Geodesix
    @Geodesix 10 лет назад

    I have almost the exact motor your referencing in this video, my question is, I plan on using this pump(motor is attached) as a turbine to generate electricity in a micro-hydro electric configuration. I am curious if I turn on the water flow and bring the motor up to speed, will it be generating electricity or would I need to field flash the coil to start the process...? I know with a PMA you wouldn't require the field flash, and if i'm understanding it correctly a three phase motor could be phase shifted with capacitors to negate the need for field flashing the motor, but with a single phase motor like the one in this vid do you think it would be required...?

    • @electronicsNmore
      @electronicsNmore  10 лет назад +1

      Please refer to this video:
      How To Use An AC Motor(Induction or synchronous) As A Generator
      The video explains how it is done. You need to spin the motor slightly faster than the rated RPM.
      Thanks for watching! Be sure to rate "thumbs up", and share.

  • @claudioreyes7070
    @claudioreyes7070 4 года назад +1

    Thanks very much excellent

    • @electronicsNmore
      @electronicsNmore  4 года назад

      You are very welcome! Be sure to look over my extensive video playlists below for many other videos of interest to you, and share links to my videos with many others on social networking sites. Thanks
      ruclips.net/user/electronicsnmoreplaylists

  • @rubbish2307
    @rubbish2307 3 года назад +1

    hi video author, do u mind to post the wiring diagram that i can learn better from u. thanks

  • @kitkirkyen2002
    @kitkirkyen2002 4 года назад

    Hello sir, I am your new subscriber and I was amazed for the detailed explanation. Thank you so much for sharing your skills. I cannot find the images link on the motor pictures that you have shown. Can please send me the exact links for the images. Thank you so much...

    • @electronicsNmore
      @electronicsNmore  4 года назад

      I'll replace the links shortly. Thanks for watching! Be sure to share the video, and rate thumbs up.

  • @deslomeslager
    @deslomeslager 11 лет назад

    If the motor is running, can you use the start winding as a generator? I think it should. No idea if it can be useful.

    • @electronicsNmore
      @electronicsNmore  11 лет назад

      This motor was used in an induction generator that I made years ago. I ended up switching to my inverter generator which is in my video list.
      When I made the induction generator, I used BOTH windings for power. The main winding supplied most of the power to a 120V receptacle(60V per leg since there was no center tap on the winding), and the start winding supplied around 350W or slightly higher power output at a voltage which was a little higher than the main winding.
      Once the motor is operating at full speed, you should be able to take power off of the start winding(red and black wires).

  • @shanewattenbarger4061
    @shanewattenbarger4061 6 лет назад +1

    great video

    • @electronicsNmore
      @electronicsNmore  6 лет назад

      Thanks Shane! Be sure to check out my extensive video playlists for other great videos of interest to you, rate thumbs up, and share my channel with all your friends.

  • @fathyibrahim9268
    @fathyibrahim9268 6 лет назад

    It's great video really I interested with it
    Plz I need the pics which in the video

    • @electronicsNmore
      @electronicsNmore  6 лет назад

      Do screenshots using full screen high resolution and print them. Thanks for watching!

  • @nickgomez.8715
    @nickgomez.8715 7 лет назад

    Great job.

  • @boopiedistura
    @boopiedistura 5 лет назад

    Hi there electronicsNmore new subscriber here. Our power supply is 220v. I bought a 1/3hp Gould Pump J03 Series from a scrapyard this morning. I opened it and it says 123mfd-140mfd 110-115v capacitor. I was not sure if it can run 220v or not. But I try to plug it to 220v abrultly and it turned. What will I do?
    Respectfully,
    Boolie Distura

    • @electronicsNmore
      @electronicsNmore  5 лет назад

      I have no idea if you have a dual voltage motor. That's an obsolete motor. 220V motors use 110V caps. Thanks for watching!

    • @apllDgrapllD
      @apllDgrapllD Год назад

      @@electronicsNmore if I’m reading only around 115v should i change my pump motor to 120 rather than 220?

  • @ennricklafrance7689
    @ennricklafrance7689 6 лет назад

    So I just got a pump with a plug .. how do I wire it to wires already coming out of my 230 box out side it can go 120 or 230 ? Help??

    • @electronicsNmore
      @electronicsNmore  6 лет назад

      Ennrick LaFrance If indoors, then cut off the plug and strip the wires. You need to buy a 1/2" Romex clamp to secure it to your pump timer box. 120/240 conversion info should be shown on the motor.

  • @edmasias2430
    @edmasias2430 10 лет назад

    can you direct me to site that provides picture wiring diagram..thank you in adv.

    • @electronicsNmore
      @electronicsNmore  10 лет назад

      Hi Ed,
      Sometimes there is a wiring diagram for 120v/240v conversion on the rear side of the power supply metal plate(cover) on the motor. For a specific wiring diagram(including the windings), you need to look up the manufacturers name/model.
      Thank You

  • @StrongRN
    @StrongRN 7 лет назад

    Can this motor run in reverse.

    • @electronicsNmore
      @electronicsNmore  7 лет назад

      Reversing the start winding wires in relation to the run windings, should make it spin backwards.

  • @johnMcCororey
    @johnMcCororey 4 месяца назад

    My yellow wire came loose from the winging

  • @frantz-cadetfils-aime8105
    @frantz-cadetfils-aime8105 11 месяцев назад

    Changer 230 en volt

  • @mohammadzain1959
    @mohammadzain1959 Год назад

    Please fell in hindi. A video make in hindi it's motir winding and repairing

  • @utuber671
    @utuber671 11 лет назад

    Thanks for all the great vid's I'm enjoying and learning and hope to find some beginner projects I can get started on
    Utuber671

  • @SgtTonybertram
    @SgtTonybertram 8 лет назад

    Hell get to the trouble shooting, what a terrible video on testing

    • @electronicsNmore
      @electronicsNmore  8 лет назад +6

      This video was excellent. You must have watched another video. Everything you need to know is in the video if you had any patience. Have a wonderful day. :-) Never complain about something you get for free.