Field Density test By Sand Replacment Test with Calculation

Поделиться
HTML-код
  • Опубликовано: 28 дек 2024

Комментарии • 26

  • @harshalpatil3362
    @harshalpatil3362 Год назад +2

    Perfect Video for understanding who saw practically at field.🎉

  • @chetrammeena4677
    @chetrammeena4677 Год назад

    Very good 👍👍👍👍

  • @AVTECHSOLUTION
    @AVTECHSOLUTION 3 года назад +1

    Bahut khub

  • @anupamsharma3813
    @anupamsharma3813 8 месяцев назад

    Thank you 🙏🏻😊

  • @bijayakumarpanda556
    @bijayakumarpanda556 4 месяца назад

    When pouring the sand in hole , don't use tray under the pouring cylinder ( according is 2720 part 28)

  • @sunilpillala5100
    @sunilpillala5100 2 года назад +2

    hole depth 15 cm se jadha nahi lesaktha kya sir...

    • @HIGHWAYQAQC
      @HIGHWAYQAQC  2 года назад

      Then we need to use large cylinder

  • @sunilpillala5100
    @sunilpillala5100 2 года назад +1

    gsb layer depth 200 mm ...200mm depth nikalke testing karsaktha hai sir

  • @basitwani1873
    @basitwani1873 11 месяцев назад

    Aap bolte he ni hoo is code k acc procedure, kitna hole lena ha kya krna ga

  • @Azizkhanpk11
    @Azizkhanpk11 Год назад

    Sir sieve ka name kea hn ,
    Ap ne batana hn likn wazih ni bataya hn ,

  • @Dddmrnt
    @Dddmrnt Год назад

    Which kind of sand is used???? That's a special sand, isn't it??? Plz mention....

    • @user-ux3rj7uc5r
      @user-ux3rj7uc5r Год назад

      Sand passing through 1mm IS sieve and retaining on 600micron IS sieve

  • @taranjeetsingh3295
    @taranjeetsingh3295 2 года назад

    Aur agar compaction 100 percent se above aa raha he to kya smjhe. Pass ya fail

    • @gaurav0559
      @gaurav0559 2 года назад

      Fail phir aapko uska geadation check karna hai

    • @Azizkhanpk11
      @Azizkhanpk11 Год назад

      Cylinder ka measurement kea hn ?

  • @biswarupmaiti3773
    @biswarupmaiti3773 3 года назад

    Test procedure is wrong please follow the code is :-2720 part-2 clause 4.2.2 page no.11

    • @HIGHWAYQAQC
      @HIGHWAYQAQC  3 года назад

      There are also mention Rapid moister meter test procedure... Can you pls clear how is this wrong...

    • @biswarupmaiti3773
      @biswarupmaiti3773 3 года назад +1

      @@HIGHWAYQAQC The metal tray shall be removed before the pouring cylinder is placed in position over the excavated hole. Please see the Is Code:-2720 part 28 page no.11 clause 4.2.2,

    • @HIGHWAYQAQC
      @HIGHWAYQAQC  3 года назад +1

      Sir as I observe while we do pouring in hole... the circumference of hole may collapse due to weight of cylinder, practically it's happened.. So we put tray under it... It is a practical process sir... Not written anywhere..

    • @biswarupmaiti3773
      @biswarupmaiti3773 3 года назад +1

      @@HIGHWAYQAQC Care shall be taken in excavating the hole to see that the hole is not enlarged by levering the dibber against the side of the hole, as this will result in lower densities being recorded. The metal tray shall be removed before the pouring cylinder is placed in position over the excavated hole, to recorded the proper density of compacted soil or others. In practically if you don't remove the metal tray before pouring the cylinder then it's shows the higher density , not shows the actual density

    • @HIGHWAYQAQC
      @HIGHWAYQAQC  3 года назад

      Ok sir

  • @ijazarif245
    @ijazarif245 Год назад

    You are doing well work.i am new frien d here.u must be com e at my sweet home