Replace Solenoid Valve JYZ-5 in Philips Steam Iron GC9630
HTML-код
- Опубликовано: 7 сен 2024
- Pam air berada dalam keadaan yang baik. Apabila suis pelepasan stim ditekan, tiada stim dilepaskan. Kemungkinan suis atau solenoid valve bermasalah. Video merangkumi proses menguji solenoid valve menggunakan multimeter. Terima kasih kerana menonton.
The water pump is good. Pressing the steam release button after the beeping buzzer, but no steam released and no clicking sound from the unit. Well, probably it is the switch fault or control pressure valve (solenoid valve) fault. Video including all steps to test solenoid valve using a multimeter. Thank you for watching.
Salam dari Cheras KL. Bagus video ni dan mudah paham. Teratur....Tahniah. dapat ilmu percuma hari ni. Saya pikir pump rosak maka beli pump. Tapi ada lain yg rosak. Nak cuba tukar solenoid valve pulak. Tq
Respect..tukar solenoid tanpa bukak sensor boiler
Trima ksih dgn ilmu yg sngat membantu.
Sama sama
Terima kasih, nanti nk cuba
I believe replacing only solenoid part (without the whole valve) would also do the trick and save a lot of time 😉
Yes but i can’t find that internal parts online.
@@petrusgoel What I meant was to disassemble new part and replace only solenoid.
@@Tenktoryowh sorry you mean just replace the coil. Yes no problem. But since i have complete new parts that come with new valve…i choose to replace the whole set.
@@petrusgoel Sure. I get it. That is just a small remark from my side. Actually I used your tutorial (thanks!) yesterday to fix my device and thought about simplifying repair when it was already finished 😅 So it is just a humble suggestion for the people who will have to do the same fix.
Terbaik
Excelente explicação, obrigada
Thank you😊
Iron steam saya jadi tak boleh off. Butang powernya boleh On, tapi tak boleh off. Jadi saya terpaksa tutup di plug utama. Saya bimbang iron steam rosak. Utk makluman saya telah cuba tukar pam sendiri. Seterika berfungsi dengan baik tapi butang off pula tak berfungsi.
Cuba check connector yang bersambung ke suis pada PCB ...takut sambungan tidak rapat semasa pasang semula
@@petrusgoel saya dah cuba rapatkan kabel dan akhirnya suis power kembali berfungsi dengan baik dengan hanya sekali tekan. Terima kasih banyak2 Tuan di atas segala tunjuk ajar.
@@MsArmy00 well done!!! Terima kasih singgah youtube saya 👍🙏
@@petrusgoel Semoga Tuan terus dapat buat video yang bermanfaat dan terus maju jaya.
Tq tuan. Mcm mana kita nak tahu sama ada Water pump atau solenoid valve yg kena tukar ? Apa symptomp yg kita boleh lihat?
Nak check pam rosak ka tidak:
Ketika sejuk…Kosongkan/buang air dari tangki boiler. Lepas tu isi tangki air (tangki biru) dengan air dan ON kan stereka. Semasa ON dan pam berbunyi…perhatikan sama ada paras air dalam tangki biru berkurang. Kalau berkurang, maksudnya pam berfungsi dengan baik. Kalau tidak berkurang, pam rosak. Air tidak dipam masuk dalam tangki boiler…
Kalau solenoid valve rosak, bila tidak tekan suis stim…stim dah keluar. Atau ketika tekan suis stim, tiada stim keluar walaupun ketika itu ada bunyi click. Pastikan ada air dalam boiler la ketika check solenoid bagus atau tidak.
Harap membantu
Hi! I've got almost the same iron (GB9620) after changing the water pump blue (power) and green (eco) lights are blinking. Do you have any solutions or ideas how to troubleschoot that problem?
Hi, sorry late reply. How is it? Is the problem solve already?
Terima kasih tuan… Cuma saya terpikir, kenapa kita tidak bukak saya yg sebelah tu ( kedudukan tengah2 boiler ) senang mau pasang solenoid valve tu.. tak perlu bukak dan pasang kembali…
oh yang minit 11:50 yakah? sebab bolt set thermocouple tu ketat....risau akan rosak thread nanti.
oooooo yang tgh2 sambung dgn wayar putih tu thermocouple ke?.. baik sifu… kalau mcm tu tak ada cara lain memang kena bukak dulu unit baru valve tu… terima kasih..
@@mohdfazlinmohtar9026 ya..itu thermocouple
Nat pum tu ketat sgt tn.
Tak blh buka ...
Macam mana yer?
Dah dapat buka ker?
Saya dah tukar solenoid valve tp masih tak keluar steam, apa cara boleh buat lagi. Air steam banyak di decal.
@@marnimarien pam hidup tak? Ada air masuk dalam boiler?
Pam hidup, air masuk. Decal ada air panas banyak setiap kali on. Tp wap xkeuar jgk @petrusgoel @@petrusgoel
@@marnimarien ok. Wap tak keluar….air ada tak masa tekan butang stim? Takut dia panas tapi tak cukup panas untuk produce steam. Satu lagi takut sumbat kat soleplate
tuan, solenoid valve tu saya measure dapat dalam 2.5 kilo ohm. ok tak dapat bacaan tersebut?
I have problem with my gc9630! The center protective relay drop when connect my steam generator. When I was opened the case I saw the spark on the solenoid valve. Could you please tell me if this part can do this? Also if try to replace the valve must replace and the other bronze part? Thank you for your time!
may I know which part is the 'center protective relay'? The valve is usually one set. May I know what is the problem? No steam? The solenoid valve not clicking?
@@petrusgoel the protective relay from house power switchboard! The steam iron does not start! I saw some cracks on this part (I follow your disassemble instructions).
@@stelios_sikiotis owh...OK. So probably the coil in that solenoid valve is short between Live and Neutral. That is normal since the valve works in 'hot' operations. Try replacing the solenoid valve set. maybe for a start, If you have ohm meters, check the resistance between the 2 L-N terminals on the coil. Zero or near Zero = faulty coil.
@@petrusgoel on my multimeter I don't get any Ω ohms metering , just get k ohms 1. Also not continuity on L N ground. I will to replace this part. Thank you!
@@stelios_sikiotis alright….good luck.
Hi! Since noone is answering me, would you happen to know what to check if steam is discharging without pressing the trigger button. If i press the button there will be more steam, but when i let it go, there will still be steam discharging from my iron.
Thank you!
Alright. I just check the valve. There are two posibility. 1. The spring inside the valve getting weak….lead to weak valve closing. 2. The rubber that close the valve prbably getting hard or faulty. These 2 condition can lead to ‘leak’ steam from the boiler to the iron even when the switch is off. My suggestion, replace the valve. You can see the spring on minutes 13.00.
@@petrusgoel Thanks for the quick reply!!! As a matter of fact, 5 minutes ago i dissasembled the valve, put it back, worked for about 30 seconds, then the leak started again. Will replace it with a new one.
Thanks again and all the best
L.
@@lukaskorjanc407 welcome…
Just to let you know it was the spring. I cut a piece of wire and put it in the hole under the spring, and now the spring has more power to close the valve.
Thanks again!!
L.
@@lukaskorjanc407 wow that's great!!!! save $$.
Poderia me passar a medida da mola que mostra nos 13 minutos? Ela é de ferro ou inox? Obrigada
Diameter =3 mm . Length =18.4 mm . Material stainless steel
Selamat pagi tuan. Saya punya model cg9660. Saya nampak wap air yg keluar tu kurang. Kadang2 tak nampak.
1. Water pump ok. Lepas kosongkan tank, tekan on ada air mengalir melalui lubang easy decal.
2. Buat flushing ada air keluar tapi di bahagian atas soleplate saja.
3. Bila tekan ada bunyi click mcm biasa.
4. Wayar host panas
Agak2 tuan masalah apa ya?
Mungkin air yang masuk dalam boiler tak banyak. Pam ada masalah….air tak banyak/cepat masuk tangki. Kalau bunyi pam lebih kuat daripada biasa, mungkin pam ada masalah…..ada bebola dalam unit injap pam yang rosak.
Hello boss..iron sy pump bunyi tapi air tak nak masuk dlm boiler ..tukar pump baru pn masih sama juga ..bila masuk kan air dlm boiler ikut lubang decal wap boleh keluar .apa masalahnya ya ?
Tukar pam complete set bersama hos yang masuk boiler? Kalau ya, cuba cabut hos yang masuk ke boiler. Cuba on semula dan tengok ada air keluar dari hos ka tidak….
Tuan, nak tanya, masalah iron sy ini, bila sterika baju, wap keluar tp kelauar skali dengan air. Baju basah. Apa ya tuan masalahnya? Terima kasih atas bantuan
1. Pam berfungsi dengan baik dan pam air dari tangki ke boiler? Kalau pam bermasalah isi boiler, stim cair boleh berlaku.
2. Adakah tuan tekan suis ketika iron sudah betul betul panas? Kalau iron belum cukup panas, stim akan cair bila kena permukaan stereka sebab stim lebih panas dari permukaan stereka. Tunggu sehingga stereka panas. Tekan butang stim beberapa kali supaya stim menolak air yang masih ada pada hos…air tu yang biasanya akan meleleh
Sy punya iron bila on suiz,lampu on off blinking je,apa masalah ye?
Blinking dan tiada apa apa bunyi? hanya blinking?
Tuan nak tanya, iron sy bile tekan on fius box tendang... Apa masalahnya.. model gc9622
RCCB ka? Yang ada butang tekan tu..
Btl tuan... Fius dekat plug x putus, tp dekat DB dia tendang
@@mohdalifmohamad9761 ada leakage to ground tu. Kena buka unit dan check. Ada banyak kemungkinan kenapa ini berlaku.
Tuan boleh kasi no whatsapp
@@mohdalifmohamad9761 saya dah padam no henphone saya. Dah ambil tak?
Salam tuan saya dah tukar PUM tapi wap keluar sedikit kenapa ya.
Pam hanya pam air dari tangki ke dalam boiler. Kalau wap ada keluar dari stereka, kemungkinan ada kebocoran dari solenoid valve. Ini jangkaan saya.. kerana kalau valve ada leak (tak tutup habis) mungkin akan ada leak. Cuba buka valve dan check mekanisma valve, takut ada bendasing yang sangkut kat valve.
tuan, mcmana ya iron saya bunyi steam tapi bila iron dia keluar air dan baju jadi basah, nak repair apa ya?
Ok. Saya pernah jumpa masalah ni sebab pam rosak. Air tak banyak masuk dalam boiler menyebabkan bila steam keluar…ia bertukar jadi air bila sampai stereka
@@petrusgoel terima kasih tuan. apa alat ganti yg patut saya beli.
@@nurdzifazuradziyauddin9135 sebelum tukar barang, cuba test tengok ada air dipamnmasuk dari tangkinke dalam boiler ka tidak ketika pam hidup. Keluarkan air dari boiler dulu.. biar kosong. Isi air dalam tangki. On dan lihat paras air….
Hello, I am from Iran, can I ask a question about Auto Phillips?
Yes sir. Is it Philips Steam Iron?
Yes
NL9206AD-4DDrachten
Steam comes out from under the main plate of the iron tank
And steam also comes out of the on switch
Tuan , sy sudah tukar valve tpi masih tk keluar apa mungkin masalahnya tuan
Ada bunyi 'click' pada valve bila suis kat stereka ditekan tak?
Tk ada tuan
@@irfanafiq3868 sebelum tukar takda bunyi? Selepas tukar takda bunyi juga? Cuba check voltan ke coil solenoid valve ketika suis ditekan …ada voltan ka tidak?
Tuan, macammana nak pastikan selenoid valve atau waterpump yang rosak?
Solenoid valve, akan clicking dalam unit apabila suis kat iron ditekan. Kalau takda clicking, itu tandanya solenoid valve problem. Waterpump pula akan pam air masuk ke dalam boiler apabila air kurang dalam boiler. Boleh dengar bunyi pam tu. Nak check pam, …. Masa sejuk, buka drain plug. Keluarkan semua air. Tutup balik, dan isi air dalam tangki. On semula unit, dan pam mesti hidup dan pam air masuk boiler. Boleh lihat paras air turun kalau pam bidup.