Solar powered air conditioner WORKS without the SUN!

Поделиться
HTML-код
  • Опубликовано: 28 июн 2024
  • Solar powered air conditioner installation video
    • Cool Your Home for FRE...
    Signature Solar Website
    signaturesolar.com/?ref=kvNax...
    Use Code Taddy50 for $50.00 off your order over $500.00
    Eco-Worthy Website
    www.eco-worthy.com/
    Use Discount Code "Taddy30" for $30 off your order
    Solar Setup DIY Guide Video
    • Revolutionary Solar Se...
    Need an HVAC Lineset Cover, Check out this video.
    How to install hvac line set covers?
    • Transform Your Home wi...
    Go Check out Permacover Website
    permacover.com/
    Use Code Taddy5 for 5% off your order at www.permacover.com
    HVAC Tools
    Digital Torque Wrench
    amzn.to/3vJ3gJd
    Mighty Bracket Mini-Split Support Tool
    amzn.to/3W03Aho
    Join this channel to get access to perks:
    / @taddydigest
    Wanna learn more about hvac? Check out my hvac tips for technicians playlist.
    • HVAC Tips for Technicians
    Taddy Digest Website
    taddydigest.com/
    Click this link to get your website consultation.
    moderncontractorwebsites.com/...
    Modern Web Studios has Built, hosted and maintained my Website.
    modernwebstudios.com/
    Fill out the contact form at modern web studios
    modernwebstudios.com/contact/
    ‪@SignatureSolar‬ ‪@eg4electronics‬

Комментарии • 120

  • @MrJeffDemme
    @MrJeffDemme 16 дней назад +11

    Nice job. Two criticisms though from a 40 year veteran HVAC company owner. 1- You should not interrupt the white neutral wire in the disconnect. It is a two wire disconnect for 240 volts where both lines are "hot". A neutral wire should never be broken or switched. Simply connect the white wires with a wire nut and you will be code compliant. Only the black wire should get disconnected by the disconnect. 2- the coil of line set is bad news. Not only is it less efficient due to temp loss but when the coil is vertical like that it can become an oil trap and cost you a compressor. It is best to cut the line and reflare it to the correct length. This requires the use of a vacuum pump after connecting. DIYers typically do not have a vacuum pump. Just my two cents..

  • @cue881-yo7kz
    @cue881-yo7kz 25 дней назад +6

    Kudos to EG4 that their equipment shuts down when there is no sun and starts back up again when the sun comes up. My 3000 watt EG4 inverter does the same thing. No intervention required. For those of you who want to run this day and night in a house, run it off an EG4 inverter on AC. Their inverter handles up to 5000 watts of solar. Hook it up to the EG4 battery. The solar will run the mini split and any extra solar will charge the battery and you never have to touch anything. I wouldn't do it for this shed but I would set it up for a house. The inverter is about $700 and the battery is about $1200

  • @vincentstouter449
    @vincentstouter449 4 дня назад +1

    I thought the max AC draw was 16A, which would make a 20A circuit breaker appropriate to prevent overload on a 15A CB. Since the wire being used (12/3?) is already sized for a 20A CB, then a 15A CB is undersized for the conductor. It’s common for 15A & 20A CB (14/3 vs 12/3) to be mixed in inadequately inspected residential installations. 😎

  • @TheObserver567
    @TheObserver567 Месяц назад +4

    Love it. Need to get one for my garage!

  • @jerrytalley802
    @jerrytalley802 10 дней назад +1

    You do some of the best videos with explanations I have ever seen, very cool stuff

  • @MrRonaldck66
    @MrRonaldck66 Месяц назад +3

    Very well explained excellent job! Thank you for all the info. I’ll definitely get one!

    • @TaddyDigest
      @TaddyDigest  Месяц назад +1

      excellent brother, here is a discount
      Signature Solar Website
      signaturesolar.com/?ref=kvNaxADKBHncIq
      Use Code Taddy50 for $50.00 off your order over

  • @MrJeffDemme
    @MrJeffDemme 16 дней назад +1

    You need a DC amp meter. Klein makes a nice one for around $100 available at Home Depot. Then you could check how much power your unit is getting from the solar panels.

  • @anthonycoffee7683
    @anthonycoffee7683 Месяц назад +4

    You should always run the solar panels to a battery and charge the batteries when the loads aren’t being used. That builds up power throughout the day and uses it as long as the batteries have charge.

    • @MiamiUFO
      @MiamiUFO 27 дней назад +1

      The idea is to have a minimal system, batteries and inverter are extra points of failure, inefficiency and cost. This is not a total off grid solution.

    • @jerrytalley802
      @jerrytalley802 9 дней назад +1

      Don’t you have an inverter to run the AC side when the sun goes down? If so, assuming you have solar and batteries for that setup already? Cool concept though. Imagine that thing in tropical places like Hawaii where the sky is clear, and clear view of the sky. In summer, you would have solar powered AC until 8:30pm or later. Great concept, thanks

    • @TaddyDigest
      @TaddyDigest  9 дней назад

      @jerrytalley802 yes

  • @PlumCrazyRob
    @PlumCrazyRob Месяц назад +5

    Hi Tad, enjoyed your video again as you explore and learn about the features on these. Someone said on last vid you dont have Wifi available (yet?) at the shed?? There are lots of additional features in the Wifi app, shows power blend stats and usage, you can schedule on/off times and so on. Thx! Great job on $50 discount code as well.

  • @dammitbobby283
    @dammitbobby283 Месяц назад +21

    Those DIY mini splits need to come with a short length of tube and then they can sell extensions that are charged. Almost every video on RUclips has 10 feet of wasted tube coiled up outside which makes the system less efficient than it has to be.

    • @PlumCrazyRob
      @PlumCrazyRob Месяц назад +1

      No kidding. 16 feet is too long for first floor and too short for 2nd floor.

    • @Chris-gy1hf
      @Chris-gy1hf Месяц назад +4

      They do, but at the same time they can't keep 25 different length linesets. It doesn't make it less efficient, it's just a plain ugly eye sore. That's what I have against the precharged linesets, plus the connections are more prone to leak. Another thing, all units also have a min/max linesets length that they reguire.

    • @dammitbobby283
      @dammitbobby283 Месяц назад +3

      @@Chris-gy1hf No, it's less efficient because the entire coil length remains cold for AC, and the insulation doesn't fully cover the coil. Insulation is never 100% efficient either. An unnecessarily long coil length decreases system efficiency.

    • @thomascrabtree
      @thomascrabtree Месяц назад +1

      You're supposed to have a plumber or AC guy install it who will have his own copper tube slicer and blowtorch to weld the end joint on. Takes 10 seconds but you need two really specific and expensive tools that aren't worth it if you're setting up your own system.

    • @dammitbobby283
      @dammitbobby283 Месяц назад +2

      @@thomascrabtree no

  • @brandonnorris927
    @brandonnorris927 2 месяца назад +4

    Great videos really like the updates ..

    • @TaddyDigest
      @TaddyDigest  2 месяца назад +3

      Excellent. I will keep them coming. Thank you so much for watching

  • @danpresson
    @danpresson Месяц назад +3

    Awesome video

  • @andyvitz
    @andyvitz 2 месяца назад +6

    Just curious why you don't have solar on the 2 directions.North and South like you know, you need just a question.And then why did you just add some batteries to run thanothing during the night

  • @WiSeNhEiMeR-1369
    @WiSeNhEiMeR-1369 26 дней назад +1

    thanks
    COOP
    ...

  • @HVACMAVERICK
    @HVACMAVERICK Месяц назад +2

    @Taddydigest Love your videos! Thank you.
    Can you please explain to me the reason for the excess lineset coiled behind the unit?

    • @TaddyDigest
      @TaddyDigest  Месяц назад +2

      there are quick connects and this is a diy install so the line sets are made to connect and not made to be cut and shortened

  • @Fred_Durst1
    @Fred_Durst1 15 дней назад +1

    thanks Jimmi Simpson!

  • @detroitjohn4724
    @detroitjohn4724 2 месяца назад +3

    what kind of spray foam in shed ? closed or open cell ? how thick ?

  • @SgtJoeSmith
    @SgtJoeSmith 2 месяца назад +2

    I looked into this after stumbling on your other video yesterday. I was looking into creating a set up like this last summer for my shop before knowing those hybrid units existed to run direct from solar. I got a shop out back with 50 amps from 3 circuits going to it. 15a for lights, 20a for office outlets and office window ac. 20a for shop outlets which air compressor, car lift, hoist, fan and fridge are on but those are only powered occasionally except fan and fridge and 1 at a time. So I thought a mini split run on solar be perfect cause when i needed it would be like 11 am to 6m when panels generating most power. and it wouldnt over load my limited circuits.
    now my question is: the roof faces east and west but is a fairly gentle slope. Would the included panels be enough if all are on the west side? Or should i get an extra panel or 2 for the east side to help with late morning power to keep it on 100% solar?
    I guess you can use it as a heater too cause its basically a heat pump. running it in the winter on AC wouldnt be a big deal cause not using tools and stuff as much and would just want to keep the building above 40 at least when not using it to keep stuff from freezing.
    I was going to go with the 24k kit. the part that would be heated and cooled is something like 600sqft but 15 ft ceiling at peak and in the south i figured the extra cooling power would help cause we will be opening a 10 ft wide sliding door often to pull stuff in to work on.

    • @TaddyDigest
      @TaddyDigest  Месяц назад +1

      The panels would not be enough just on that side. I would definitely get some extra panels. That way, they can face the West as the sun goes further to the West. That way, you can have the solar power powering the air conditioner for most of the entire day

    • @TaddyDigest
      @TaddyDigest  Месяц назад +1

      Signature Solar Website
      signaturesolar.com/?ref=kvNaxADKBHncIq
      Use Code Taddy50 for $50.00 off your order over $500.00

    • @SgtJoeSmith
      @SgtJoeSmith Месяц назад

      @@TaddyDigest thanks. How heavy are the panels? The shop (built prior to me) has rough cut 2x4 probably douglas fir for the rafters 24' OC and spanning 14 feet at around a 4/12 pitch. I was already in the process of reinforcing it by adding 2x8s 16" OC. you can span 14 feet with 2x8s 16 OC for floor joists. But thats the max. Do you think the 10 new 2x8s with the 8 old 2x4s would be enough to hold the weight of the panels? Or should I go with 2x10s for that section? its a metal roof btw. with plywood under metal. Building is 40 or 50 years old but been renovated some over the years.

  • @timcat1004
    @timcat1004 Месяц назад +2

    Brutal

  • @Quentyn73
    @Quentyn73 2 месяца назад +3

    That's a pretty revolutionary system. Do you expect it to explode into a widely used system any time soon?

    • @SgtJoeSmith
      @SgtJoeSmith 2 месяца назад +3

      im getting 1

    • @jasonrico8558
      @jasonrico8558 Месяц назад +2

      I have 2 here in AZ where it makes the most sense to use the sun that is causing the heat to cool your house. It is great in the winter here too. To knock the chill off in the garage

  • @mndough1
    @mndough1 Месяц назад +3

    Question for you. Does the unit automatically restart after a loss of solar input, when running on dc only?
    Thank you sir. Fine work.

    • @TaddyDigest
      @TaddyDigest  Месяц назад +1

      yes sir

    • @chrs1212
      @chrs1212 Месяц назад

      @TaddyDigest That was my question too, because in the video it seemed as though you had to restart the system?

  • @larryclaus5625
    @larryclaus5625 Месяц назад +1

    Hey Tad, you should let me come over and check it out!!! Pretty frickin cool!!

  • @tommavrakos
    @tommavrakos Месяц назад +1

    Build a nicer looking shed.great video

  • @transmotion23
    @transmotion23 Месяц назад +1

    Can you explain what the inverter is for? During your installation video, it looked like you plugged the solar panels right to the condenser, without any extra inverter needed. In this video, you have one mounted to the wall, and it seemed like it’s part of the circuit somehow. I can see it’s what’s producing your 120v, some I’m guessing it’s a battery backup system, separate from the solar panel for the split, ya?

    • @TaddyDigest
      @TaddyDigest  Месяц назад

      Yes, it is battery backup for the mini split
      I actually did an update video I posted the link in the description and in the comments go check it out

  • @TheEastCoastSensation
    @TheEastCoastSensation Месяц назад +2

    Hello Tad. Great job on the video. Hope you can help me on this question. I want to purchase this AC/Heater unit for my new shed.
    I wanted to hook up a 30 amp box inside then plug into a 30 plug.
    Want to run washer and gas dryer. This AC, 2 TV’s, ceiling fan and strip led lights.
    I was looking for a solar hook up to help of set the coast of the electric bill in this shed. What do you recommend? Thank you

    • @TaddyDigest
      @TaddyDigest  Месяц назад

      At signature solar, they will help you with design
      You should call them and talk to him about what you want.
      Here is a discount you can use. Let Em know that I sent you.
      Signature Solar Website
      signaturesolar.com/?ref=kvNaxADKBHncIq
      Use Code Taddy50 for $50.00 off your order over $500.00

    • @TheEastCoastSensation
      @TheEastCoastSensation Месяц назад +1

      Thank you for responding. I will reach out to them.

  • @rexxer6456
    @rexxer6456 17 дней назад +1

    Question
    Do they have a model with a heat option?

    • @TaddyDigest
      @TaddyDigest  17 дней назад

      they heat as well
      they are heat pumps

  • @pushplay4me
    @pushplay4me 2 месяца назад +3

    When the sun goes down and the unit shuts off, does it retain all of its memory? Like Wi-Fi connection last temperature and mode for when the sun comes up the next day it just starts up and connects to Wi-Fi and starts running again. Or does it lose the whole set up and it have to be turned back on manually And reconnect to Wi-Fi.

    • @TaddyDigest
      @TaddyDigest  2 месяца назад +1

      It keeps going. It keeps its memory. It automatically switches over

    • @pushplay4me
      @pushplay4me 2 месяца назад

      @@TaddyDigest right when connected to AC switch is over automatically I’m asking on solar only does it retain all memory and reconnect and start in the morning? I should have been more clear with my question.

    • @PlumCrazyRob
      @PlumCrazyRob Месяц назад

      Starts when sun comes up on Solar only (It's super cool to watch it "wake up" lol) Sometimes, though with clouds and obstructions low on the horizon it will shut off with the LP-Low Power. For Solar only get a maximum number of panels and it really works best with AC connected still.

    • @jasonrico8558
      @jasonrico8558 Месяц назад +5

      Yes they retain their settings. And reconnect to wifi when they get enough pv. I have 2 of these and only run them on pv for the most benefit the one in my 2 car garage will freeze you out even when it up to 110° outside in AZ my other one in the house does good to 100° to cool my 1500 sqf space then my main AC kicks on to help

  • @TheUnlikelyPotato
    @TheUnlikelyPotato 14 дней назад +1

    Does your unit pull from AC and solar if the solar isn't enough or is it just one or the other?

    • @TaddyDigest
      @TaddyDigest  14 дней назад

      Yes, the unit pulls from a c when solar is not enough

  • @mikeyredfl3976
    @mikeyredfl3976 12 дней назад +1

    Isn't a 12K BTU unit way oversized for that shed?

    • @TaddyDigest
      @TaddyDigest  12 дней назад

      not necessarily
      Anything less than 250 square feet. You can not go over 12k.
      This unit will vary its capacity, but if it was any bigger than you would have major short cycling and bounce back effect

  • @sjbill1793
    @sjbill1793 26 дней назад +2

    So, when the unit is connected to both DC (solar panels) and AC power, does it automatically switch between the two power sources as needed to maintain power or do you have to switch it manually?

  • @glennnisidio2813
    @glennnisidio2813 2 месяца назад +1

    so you had 240 volts coming in from the panels, is there a charge controller anywhere, inline or in the unit ?

    • @TaddyDigest
      @TaddyDigest  Месяц назад

      another great question I will find out

    • @PlumCrazyRob
      @PlumCrazyRob Месяц назад

      Solar MPPT is built in, you can pop the top and see it over on one side. Also Google Deye Solar and you can read more

    • @frostyfroze7352
      @frostyfroze7352 Месяц назад +2

      There is a mppt built into the outdoor unit, it’s located on top left side, the fan keeps it cool

    • @glennnisidio2813
      @glennnisidio2813 Месяц назад

      Thanks man! going to be getting a couple!

  • @danpresson
    @danpresson Месяц назад +1

    Wondering if is there away to store power from solar power

    • @TaddyDigest
      @TaddyDigest  Месяц назад +1

      yes

    • @jasonrico8558
      @jasonrico8558 Месяц назад +1

      Yes they're called batteries. Lol but if you are asking for the excess power from the panels? It doesn't have a diverter or anything built in

  • @aihf3063
    @aihf3063 Месяц назад +1

    How do you know how many panels you need and the size of each panel

    • @TaddyDigest
      @TaddyDigest  Месяц назад +1

      Call signature solar. They have a design center that is free of charge. They will help you free of charge to design your solar system or your mini split
      Signature Solar Website
      signaturesolar.com/?ref=kvNaxADKBHncIq
      Use Code Taddy50 for $50.00 off your order

    • @aihf3063
      @aihf3063 Месяц назад

      This doesnt answer the Q brother

  • @LFTRnow
    @LFTRnow 2 месяца назад +1

    Thanks for answering my earlier question. It may not be obvious, but when you have it running off AC @10:10 and get 3.6A, it is likely drawing from both solar AND AC. I also found the manual for this, and it says on p3 that it can draw mostly DC power and the remainder as AC. You should have no need to ever manually switch power types as it will run from solar when (and however much) is available. Nice work!

    • @TaddyDigest
      @TaddyDigest  2 месяца назад

      Yes, absolutely. Correct, thank you so much. I'm glad that I was able to convey this in a way to where people can understand

    • @PlumCrazyRob
      @PlumCrazyRob Месяц назад

      Correct, and was just going to comment on this. You can tell both sources are available when you see the green solar panel and white plug on the indoor unit display. Color change to blue on plug display happens when you press the plug 🔌 icon on remote and limits AC as part of blend to 300W max (If there is NO Solar it still limits AC power to 300W max, what I do on my bedroom at night, and probably enough to also cool this shed at night)

    • @frostyfroze7352
      @frostyfroze7352 Месяц назад +1

      I have 2 of them and with the fan on low it’s at 2.5amps on ac only, 4amps on hot days on low, 970w watts is the highest I’ve seen it running on max.

  • @fukashima6586
    @fukashima6586 2 месяца назад +1

    What's with the coiled up lineset?

    • @TaddyDigest
      @TaddyDigest  2 месяца назад +1

      It had quick connectors on the end. And the line sets were already ready. To go, you don't have to vacuum

    • @fukashima6586
      @fukashima6586 2 месяца назад +1

      Won't those verticle loops in the suction line trap oil?

    • @jumpout4660
      @jumpout4660 Месяц назад

      I'm still waiting on someone to answer that question I'm also confused because you had 250 watts coming in but it was running off of ac power

  • @JonOffgrid
    @JonOffgrid Месяц назад +1

    👍 cool ir runs on120 volts to the 220 ones are a pane

  • @russellkamp8923
    @russellkamp8923 2 месяца назад +1

    So 71 is as cold as it gets?

    • @TaddyDigest
      @TaddyDigest  2 месяца назад +1

      No, it would get cooler but I didn't really let it run very long

  • @kevinroberts781
    @kevinroberts781 2 месяца назад +1

    Can you over panel the unit?

    • @TaddyDigest
      @TaddyDigest  2 месяца назад

      That's a great question I don't know

    • @PlumCrazyRob
      @PlumCrazyRob Месяц назад

      Up to the 380V DC and 12A Isc limits. (There's some debate on the Isc limit, but I'm not personally testing it and fizzling my units lol)

    • @PlumCrazyRob
      @PlumCrazyRob Месяц назад

      If you want to run Solar only, you do want to have as many panels as possible to run best. DO NOT CHEAP OUT ON PANELS FOR SOLAR ONLY!!! lol

    • @jumpout4660
      @jumpout4660 Месяц назад

      As per signature solar they told me if I'm running only panels to only put 3 panels or you will fry the unit but if you have a charge controller then it doesn't matter

  • @Just_An_Idea_For_Consideration
    @Just_An_Idea_For_Consideration 2 месяца назад +5

    QUESTION: If you do not have ANY A/C (ie. completely OFF GRID), what happens when the Sun goes down?
    Then what happens when the sun comes up?
    Will it automatically turn on to last settings, once sun comes up in morning, (without Any A/C)?
    Really important info, because if it works and restarts completely off grid, I will be buying several of these!

    • @TaddyDigest
      @TaddyDigest  2 месяца назад +2

      Excellent questions. Let me do a more detailed video

    • @Just_An_Idea_For_Consideration
      @Just_An_Idea_For_Consideration 2 месяца назад

      Much appreciated, Thanks!!!

    • @jumpout4660
      @jumpout4660 Месяц назад

      You need batteries to run at night if you are off grid

    • @Just_An_Idea_For_Consideration
      @Just_An_Idea_For_Consideration Месяц назад

      I don’t care if it runs at night.
      I want it to start back up, on it’s own, to the prior settings, once sun becomes available the next morning.
      thx

    • @jumpout4660
      @jumpout4660 Месяц назад

      You asked what happens when the sun goes down it shuts off and yes when the sun is out and has enough power it will come back on

  • @jimtedesco
    @jimtedesco Месяц назад +1

    You already have batteries for 115 volt operation which I assume you have solar to recharge the batteries, so why spend the extra money on a solar powered mini split? I would just power a regular mini split off of the batteries and inverter.

    • @TaddyDigest
      @TaddyDigest  Месяц назад +1

      This unit is just about the same price as a regular mini split. But it's already set up with the pv connectors. I would rather run my solar directly to the mini Split instead of running it to a battery And inverter

    • @jasonrico8558
      @jasonrico8558 Месяц назад

      I have a bluetti ac 500 with 3 batteries at about 7g and it would struggle to keep up with this. Compared to just buying $600 in solar panels? It's a no brainer. The problem with power stations is they don't except high voltage panels most can only do 150voc max input

    • @jumpout4660
      @jumpout4660 Месяц назад

      You only need 3 panels 370 watts each they cost $90 each

    • @vinster8884
      @vinster8884 Месяц назад +2

      Efficiency is the word you're looking for.

  • @fishycomics
    @fishycomics Месяц назад +1

    to bad its not 220vac 110vac are just weak for me

    • @RayonWhittaker
      @RayonWhittaker Месяц назад +1

      But they are also available in 220V

    • @PeterLawton
      @PeterLawton 5 дней назад

      71° is 71°, regardless of how it got there. Is there something else you meant to talk about?

  • @Mcsandwhich
    @Mcsandwhich Месяц назад +1

    That is way overkill for a lawnmower shed.

    • @TaddyDigest
      @TaddyDigest  Месяц назад +1

      😄 🤣 😂 I am the overkill king

  • @martinsteflik1329
    @martinsteflik1329 Месяц назад +3

    You are risking damaging your mini split with those Hyperion 395w solar panels. That solar mini split calls for a ISC of PV less than 12A and those panels are ISC rated at 13.7A.

    • @PlumCrazyRob
      @PlumCrazyRob Месяц назад +1

      Good point! They are bifacials, too so Isc 17.24A at 25% backside. I guess we will find out whether the "12A" limit really is a thing! (I don't think it is, but not risking my units to try it lol)

    • @jasonrico8558
      @jasonrico8558 Месяц назад +4

      Am I wrong to believe that amps are drawn? Not pushed? So basically it is just limiting it to a max of 12 A which lowers the watts?

    • @PlumCrazyRob
      @PlumCrazyRob Месяц назад

      ​@@jasonrico8558 No you're absolutely correct and I believe that's what will happen despite what the manufacturer published, which I think is a misunderstanding or mistranslation

  • @quickquote1568
    @quickquote1568 2 месяца назад +2

    Who cares.

    • @TaddyDigest
      @TaddyDigest  Месяц назад +5

      people that want to know
      ad if you don't
      then do not watch