Why Motor Starting Current is high| High Current in Motor | Hindi

Поделиться
HTML-код
  • Опубликовано: 14 окт 2024
  • Queries solved:
    1. Why motor Starting current is high.
    2. Why motor takes high current.
    3. High current in induction motor.
    4. What is slip in motor.
    5. Induction motor working.
    6. What is Synchronous speed.
    7. What is rotor speed.
    8. Motor high current kyu leti hai.
    Hello Friends, in this video we discussed about why motor Starting current is high in the simplest way possible.
    About Channel:
    In this Channel we cover the topics like Machines, Power System and General Electrical in the simplest way possible.
    #HighCurrent
    #Motor
    Kindly subscribe.
    Thank you.

Комментарии • 156

  • @suryakantyadav128
    @suryakantyadav128 4 года назад +2

    Bhot hi umda samjhaya hai ,sir aapne , aapka video deekhne ke baad har din kuch nya ,aor technical seekhne ko milta hai,

  • @SanaAkbar-ed8dj
    @SanaAkbar-ed8dj Год назад +1

    Sir your concepts are very much amazing. One of the best channel for interview preparation. Thank you very much sir

  • @azizgee5874
    @azizgee5874 6 месяцев назад

    Hye sir!
    You have such a good knowledge in electrical system and well technique to explain everything.
    I'm from Pakistan sir.
    I want to ask a question about motor, the question is how can we identify a motor having 3 wires outside that motor is single phase or 3 phase even no capacitor is connected to it?
    Please explain...

  • @shaileshsharma4175
    @shaileshsharma4175 11 месяцев назад

    Sir, I want to ask a question, that a single phase induction motor, which is 370watt, what is the resistance of running coil and starting coil,

  • @saileshchudasamasc
    @saileshchudasamasc Год назад +1

    I am looking to install a solar system to run my 2hp pump. How do i determine the right solar capacity that would be able to take the initial high current?

  • @pranavsinhparmar2301
    @pranavsinhparmar2301 2 года назад

    Hello sir,
    Mujse interview me puchha gaya tha ki motor ka inductance kese check karte he or kitna hona chahiye or iske badhne or kam hone se kya hota he ,to please agar ap isme meri koi help kar sakte ho to jarur iske bare me video banaiyega ya muje guide kijiye.

  • @dipakgurjar4660
    @dipakgurjar4660 4 года назад +1

    Great explained! Perfectly solve the my problems.

  • @sanjayreddy3583
    @sanjayreddy3583 4 года назад +8

    Wonderful explanation sir.

  • @A.Krishna2095
    @A.Krishna2095 2 года назад

    Sir jii Abb DC Draiv 880 me encoder bypass krse keya hoga. Or kese bypass krte hai?

  • @bharatgupta6172
    @bharatgupta6172 2 года назад

    Bhai kya inverter se 0.5 hp ki motors chal sakta hu kya ???

  • @arunkumarpotnoori8565
    @arunkumarpotnoori8565 3 года назад

    Sir very nice explination i have doubt if I use soft starter for reducution starting current? Plz explain soft starter characteristics

  • @vinayakbhatjire8537
    @vinayakbhatjire8537 3 года назад

    Sir current ,vtg,power factor ka torque se kya relation Hai..imeam directly proportional or inversely..ye bataye plz

  • @priyaranjanmallick8362
    @priyaranjanmallick8362 3 года назад +1

    Sir , I think as Motor Windings being inductors basically , when switched on to a sinusoidal supply , there happens the inrush of current only due to the transient response ; in fact currently through an inductor can not be changed instantly na .
    Please review my comment .

  • @mhb.school
    @mhb.school 3 года назад

    sir ek 3 hp single phase induction moter sarting apms kitna lega

  • @pankajchavan8489
    @pankajchavan8489 Год назад

    Is it correct Initially Motor Act as a Short Ckt?

  • @DieselGeneratortraining
    @DieselGeneratortraining 4 года назад +1

    Sir tech channel grow karnay k leye khuch tips dain

    • @electricalwithabhishekjoshi
      @electricalwithabhishekjoshi  4 года назад

      I think consistency and persistence is most important. Aapka content achcha ho and aap regular raho to result bilkul ayega.

  • @akhil3551
    @akhil3551 4 года назад +2

    Sir 1 doubt starting current ki reason slip se depend he ya rotor jaldi se rotate hone se he please reply

  • @ashoksahoo7968
    @ashoksahoo7968 4 года назад +1

    Sir motor pe jab load hota he ustime jitna starting current leta he No load condition me utna hi starting current lega ya use jada current lega....

    • @electricalwithabhishekjoshi
      @electricalwithabhishekjoshi  4 года назад

      Ashok, load jitna jyada hoga current bhi utna jyada hoga. Jab motor pe load badhta hai to current bhi badhta hai..
      No load condition mein motor ka current full load ke comparision mein bohot kam hota hai.

    • @ashoksahoo7968
      @ashoksahoo7968 4 года назад +1

      @@electricalwithabhishekjoshi Thank you sir

    • @electricalwithabhishekjoshi
      @electricalwithabhishekjoshi  4 года назад

      Most welcome Ashok..

  • @Electrical3442
    @Electrical3442 Год назад

    sir core k hisab se wire no.and turns kise design hote hai

  • @kamaljitsingh9533
    @kamaljitsingh9533 3 года назад

    Sir motor jark load ki calculation kase karte hain

  • @1971nandini
    @1971nandini Год назад

    What is difference between mycom relay and spam 150c

  • @RohanKumar-ez5ig
    @RohanKumar-ez5ig Год назад

    thanks sir for sach a good information or knowledge giving to us

  • @sandhyakumari5063
    @sandhyakumari5063 Год назад

    Sir...moter me v aap log students ko bataya kijiye kon sa moter hai...ac ya dc moter hai and ac hai toh AC me kon sa moter hai and agar dc hai toh kon sa moter hai...kuy ki dono ka alag rule hota.. starting current high lene ka.

  • @engineeringmaniac9696
    @engineeringmaniac9696 2 года назад

    Good one. cleared my doubt that was there for a long time.

  • @hasnainch295
    @hasnainch295 2 месяца назад

    Lekin sir slip ki value ideally kiya honi chahiyee??

  • @shriramkumawat168
    @shriramkumawat168 2 года назад

    Sir 3phase motor ko vfd se star conection me kese chalaye

  • @sdf4446
    @sdf4446 4 года назад +1

    One request :: Please explain all parts of HT Electric Motors and their faults

  • @abhimanyusahu2516
    @abhimanyusahu2516 Месяц назад

    Good advice sir 🙏

  • @s.vlegendyt4159
    @s.vlegendyt4159 3 года назад

    Sir ek video SPAM 150C me banaiye

  • @random2059
    @random2059 2 года назад

    That's I love motor than engine 🥰😍 super pickup

  • @piyushshukla7110
    @piyushshukla7110 3 года назад

    Very useful video
    Good explanations

  • @harshalbarve9091
    @harshalbarve9091 3 года назад

    No topic is tricky if you are explaining it to us👌

  • @desaitarak2776
    @desaitarak2776 2 года назад

    Sir vgood n easy clip

  • @dkverma67
    @dkverma67 4 года назад +1

    There are peak starting current ( sub transient) of 14 times of rated current for 10 to 15 m second. For DOL starter.
    Starting current shall be 7.2 times of rated current for 5 to 30 second.

  • @zaheebali5913
    @zaheebali5913 3 года назад +1

    Slip, starting current k directly proportional kese hai??
    Theory??

  • @dashok4749
    @dashok4749 Год назад

    Why starting current is directly proportionate to slip sir??

  • @mianghulamsagheer3032
    @mianghulamsagheer3032 3 года назад +1

    Hi frinds.. Please make video on potiantial trnsfarmer (pt)

  • @guddurajbhar411
    @guddurajbhar411 2 года назад

    Thanks for sharing deep knowledge

  • @chintanmehta4695
    @chintanmehta4695 3 года назад

    Superb explanation sir. Thank you very much.

  • @RajeshRaj-rp5ht
    @RajeshRaj-rp5ht 2 года назад

    I love ur explanation

  • @Divyanshusingh06
    @Divyanshusingh06 2 года назад

    awesome way of explatination

  • @desaitarak2776
    @desaitarak2776 2 года назад

    Request to make video on iMCC PL BZ ITS NOW VERY IMPORTANT AND WE KNOW ITS WORKING INCLUDING WITH ITS INTEGRATION WITH DCS SYSTEM PL ....

  • @sdf4446
    @sdf4446 4 года назад +1

    Very good explanation
    Keep it up friend.

  • @imamshaik1596
    @imamshaik1596 3 года назад

    Elevator motor ager jhatka derahay to drive me kownsa parameter adjust karna padega.

  • @saurabhmingwal8735
    @saurabhmingwal8735 Год назад

    Very well explained 👏

  • @suryakantyadav128
    @suryakantyadav128 4 года назад +1

    Sir lockout relay ke connection me Bada concussion hai , Drawing lay kar, panel me check krne jaata hu ,but live rhta hai ,to thoda dar rhta hai tripping ka , production plant hai na,to please aap drawing bana kr ek baar explain kr djye ,kaisey wire out ,aor in hote hai ek reference drawing laykr (please sir)

    • @electricalwithabhishekjoshi
      @electricalwithabhishekjoshi  4 года назад

      Okay Suryakant, let me see how to explain Drawing in videos..

    • @suryakantyadav128
      @suryakantyadav128 4 года назад

      @@electricalwithabhishekjoshi ye to difficult hai, sir per kaafi dino say atka hua hu is topic pe

  • @mobiksa2562
    @mobiksa2562 4 года назад +1

    3Phase motor me condenser lagata hai kya

  • @manpreetkumar1135
    @manpreetkumar1135 Год назад

    Thank you sir ji.

  • @Rajeevkumar-jz7xk
    @Rajeevkumar-jz7xk Год назад

    Sir how maney minimum slip

  • @manishbaria2164
    @manishbaria2164 Год назад

    Very nice sir 😊

  • @haldeeppatle9637
    @haldeeppatle9637 3 года назад

    Good explain

  • @Maharana_Rahul
    @Maharana_Rahul 3 года назад

    Sir RMF ki speed ko kese define krenge ya kese pta krenge??

  • @rakeshdubey538
    @rakeshdubey538 4 года назад +1

    Sir bahut acha...but apko vdo permanently n milta... jo chahi...khas kr motor ke total protection ke bare me

  • @hitendrasahu6649
    @hitendrasahu6649 4 года назад +1

    Sir breaker maintenance ke bare me video bnao VCB, ACB , SF6

  • @gajendrasingh581
    @gajendrasingh581 4 года назад +1

    Single phasing pe video bnaye Sir

  • @TipuSultan-kg6bl
    @TipuSultan-kg6bl 4 года назад

    Yes very good explanation 👍...

  • @RanjitP-qr1nc
    @RanjitP-qr1nc 4 года назад +1

    What happens if we select a oversized for a motor, suppose if I can select 15 or 20 HP both greater than my requirement of 11 hp. What happens if I select the 20 HP

    • @electricalwithabhishekjoshi
      @electricalwithabhishekjoshi  4 года назад +1

      Ranjit, if you take over rated motor then the it will run on less load bcoz of its oversize. This will result into low efficiency and higher losses. It will also result into high power consumption. The running cost of motor becomes high. That's why it is utmost important to select correct size of motor.

    • @electricalwithabhishekjoshi
      @electricalwithabhishekjoshi  4 года назад

      Also watch playlist for videos related to Drawing, Calculation, Motor, Transformer, Power Factor Correction and many more..

  • @CulturalyCurious
    @CulturalyCurious 4 года назад

    U are doing wonderful job in this COVID....

  • @haldeeppatle9637
    @haldeeppatle9637 3 года назад +2

    Great experience sir

  • @d.kkumar4186
    @d.kkumar4186 4 года назад

    Power house Battery bank 110 voltage ka daigram bna ke samjao

  • @aashu9317
    @aashu9317 4 года назад

    Superb informative video

  • @thesumitraj__
    @thesumitraj__ 2 года назад

    Best Explanation ❤️ thank you

  • @d.kkumar4186
    @d.kkumar4186 4 года назад +1

    Nice video sir

  • @manjujoshi6735
    @manjujoshi6735 4 года назад +1

    Excellent video

  • @ghufranahmad5516
    @ghufranahmad5516 3 года назад

    Wonderfully explained.

  • @siyaramrathore6722
    @siyaramrathore6722 4 года назад +1

    Sir, jab ek Motor ke stater aur rotor dono 1500 rpm par run kar raha hai to us time sleep ki value kya hoga

    • @electricalwithabhishekjoshi
      @electricalwithabhishekjoshi  4 года назад

      Siya Ram, agar rotor speed and Synchronous speed same ho jaye to aisi motor ko Synchronous motor bolte hai.
      Slip zero hota hai

    • @siyaramrathore6722
      @siyaramrathore6722 4 года назад +1

      Ok thank you Sir

    • @electricalwithabhishekjoshi
      @electricalwithabhishekjoshi  4 года назад

      Most welcome Siya Ram..

    • @reenamunda4229
      @reenamunda4229 3 года назад

      Siya Ram bhaiya,Stater rotate ny karta hai

    • @Dave_en
      @Dave_en 2 года назад

      1500 RPM me nhi ghumti, no load me 1480 tak ghumti hai. Load daalne par RPM kam hota jata hai aur torque badhta hai.

  • @AvikaBhajan
    @AvikaBhajan 3 года назад

    Motor ke slip ki value aur pf ka connection kya hai

  • @nigammohapatra959
    @nigammohapatra959 Год назад

    Fir us starting current me motor trip kun nehin hoti

  • @dkverma67
    @dkverma67 4 года назад +1

    Please cover
    No back Emf at time of starting
    Motor winding Z role at the time of starting

    • @electricalwithabhishekjoshi
      @electricalwithabhishekjoshi  4 года назад

      Yes it is true that high Starting current is due to no back EMF at the time of starting. Also impedance value is very low which results into high current..

    • @electricalwithabhishekjoshi
      @electricalwithabhishekjoshi  4 года назад

      Sir, I have not mentioned these two points so that people don't get confused.
      First we need to explain about back EMF in separate video.

  • @shibaprasaddakua3744
    @shibaprasaddakua3744 4 года назад +1

    Nice explain sir.

  • @Arindamdebnrh
    @Arindamdebnrh 9 месяцев назад

    Ek motor k andar itna kuch hota hai 😅.
    Aur me class 12th tk sochta tha electrical engineering kitna easy hai 🙂 current do , lorentz force aayaga aur motor chalega 🫠 definately iam not wrong that time ...

  • @riteshsindal7060
    @riteshsindal7060 3 года назад

    Thank u so much

  • @ashoksahoo7968
    @ashoksahoo7968 4 года назад +1

    Good Experience sir......

  • @abdulghaffar4425
    @abdulghaffar4425 3 года назад

    Motor ka Torque kasy kam kary with out vfd

  • @amarmane3115
    @amarmane3115 4 года назад

    hii
    sir I like your teaching

  • @00781umashankar
    @00781umashankar 4 года назад

    Thank you ,nice explanation.

  • @surajitdas1861
    @surajitdas1861 3 года назад

    Sir can I reduce the synchronous speed at the time of starting the motor?

    • @romitshirguppi3964
      @romitshirguppi3964 3 года назад

      Bhai rotor speed KO Kam Kia jasakta h na ki synchronous speed

    • @japhungsharbrahma2165
      @japhungsharbrahma2165 Год назад

      ​@@romitshirguppi3964 i think we can do it using VFD, as in VFD we controlable variable frequency (V/F=constant).
      With change of frequency, speed of rotating magnetic field in the stator changes accordingly.

  • @sanvikumari6619
    @sanvikumari6619 3 года назад

    Nice explained.

  • @TechnicalPahadiTP
    @TechnicalPahadiTP 4 года назад

    Thanks sir... Clean explained

  • @PrinceChaudhari
    @PrinceChaudhari 3 года назад

    Thanks

  • @salonikashyap6523
    @salonikashyap6523 Год назад

    Exciter ki frequency 150 Hz kyo hoti hai

  • @maroofalikhan6210
    @maroofalikhan6210 3 года назад

    Nice

  • @khivaspot3294
    @khivaspot3294 2 года назад

    Good sir

  • @rajendrasinghrathore5839
    @rajendrasinghrathore5839 4 года назад

    Very nice videos

  • @rahuldeo8160
    @rahuldeo8160 3 года назад

    why slip is directly proportional to current ?

  • @nikhilsreekumar5744
    @nikhilsreekumar5744 4 года назад +1

    For this purpose we use starters Star - Delta, DOL

  • @ashwinikumarpandey6021
    @ashwinikumarpandey6021 3 года назад

    Thanks sir

  • @nayankarmakarofficial6294
    @nayankarmakarofficial6294 Год назад

    Thnq

  • @subhranilmallick1991
    @subhranilmallick1991 3 года назад

    Very nice 👍

  • @ArifinSabuz
    @ArifinSabuz 2 года назад

    Thanks ❤️

  • @Electricalengineering-sx1yq
    @Electricalengineering-sx1yq 3 года назад +1

    Nice 👍👍👍

  • @arunjoshi2089
    @arunjoshi2089 4 года назад +1

    Good

  • @dilippatidarrau9150
    @dilippatidarrau9150 2 года назад

    डिजिटल एम्पीयर मीटर वर्ल्ड मीटर की सेटिंग कैसे करते हैं

  • @suryakantyadav128
    @suryakantyadav128 4 года назад

    No doubt sir

  • @aksingh763
    @aksingh763 3 года назад +1

    Motor ka starting torque high hota h ku

  • @s.k.electricalservicepoint4022
    @s.k.electricalservicepoint4022 4 года назад

    Sir slip me confusion hai kyuki motor ki slip to 3 se 5 % hoti hai jo ki 1 se zayda hogi

  • @VinayYadav-fg2ss
    @VinayYadav-fg2ss 3 года назад

    1hp ki motor 1500 w kyu le rahi h..?

  • @samvedna22
    @samvedna22 4 года назад

    Too gud video👍

  • @aman99singh
    @aman99singh 3 месяца назад

    ❤❤

  • @chandrasekar-pt5vb
    @chandrasekar-pt5vb 2 года назад

    🙏