Daikin erro U4, multsplit

Поделиться
HTML-код
  • Опубликовано: 20 окт 2024
  • Daikin multsplit com erro U4. Placa morta sem alimentação de stand-by. Placa e bobinas válvulas modulantes (expansão) em avaria.
    Placa com C.I ULN2003 em curto circuito devido bobina em curto.

Комментарии • 22

  • @leonardoviannamonteiro9430
    @leonardoviannamonteiro9430 5 лет назад +1

    Parabéns pelo vídeo meu amigo faz um vídeo de como testa essas válvulas de expansão eletrônica

    • @FriotecAVAC
      @FriotecAVAC  5 лет назад

      Bom dia tenho no canal um vídeo a explicar...

  • @marciorocha7152
    @marciorocha7152 5 лет назад +2

    Muito bom..👏👏👏

  • @parvejalam3380
    @parvejalam3380 4 года назад +1

    Hi sir. A Daikin inverter ac (jtkj model ) sometimes running is quite right. But sometimes machine is not on/off (indoor) do not understand that what to do now. Please quickly reply me....... Sir

    • @FriotecAVAC
      @FriotecAVAC  4 года назад +1

      Hi... Try to check the remote control and the infrared diode, possibly is the infrared receiver signal..

  • @alexandrade6888
    @alexandrade6888 5 лет назад +1

    meu amigo vrv 3 quebrando a tubulação do retorno do oleo tubulçao da descarga gas quente oque pode ser ?

    • @FriotecAVAC
      @FriotecAVAC  5 лет назад +1

      Ali atrás do compressor em alguns casos acontece de quebrar o capilar do separador de óleo.
      Provavelmente compressor em avaria ou apoios de borracha ruim... Faz uma vibração anormal e quebra as tubulações e cobre.

    • @alexandrade6888
      @alexandrade6888 5 лет назад

      @@FriotecAVAC compressor inverter vibrando mesmo vamos substituir ele

    • @alexandrade6888
      @alexandrade6888 5 лет назад

      @@FriotecAVAC pra mim fazer operação de emergencia no compressor inverter ,,vou ter que fazer no modulo que esta com avaria ou na mestre ???

  • @parvejalam3380
    @parvejalam3380 5 лет назад

    Hi.. Sir
    A Daikin non inverter ac than continue running but. Sometimes indoor automatic on/off (green light) .And timer light (yellow) glow. And whole unit shut off. Then working for remote. What problem ... Please reply.. Sir

    • @FriotecAVAC
      @FriotecAVAC  5 лет назад

      Which one... error code?
      Can you get it?
      All Daikin comes out the error code after a while working

    • @parvejalam3380
      @parvejalam3380 5 лет назад

      @@FriotecAVAC not error code show

  • @nirmalamadushanka3335
    @nirmalamadushanka3335 5 лет назад +1

    What happened mate usually u4 means communication error but here you show outdoor expansion devices whats the connection between u4 and expandion devices.

    • @FriotecAVAC
      @FriotecAVAC  5 лет назад +1

      U4 no communication.....but in this case coils's expansion valve in short circuit damaged the maim board...electronic component C.I ULN2003 ...when this component is in short circuit will put down the 15 voltage ,the stand by won't work and then we've got the U4

    • @nirmalamadushanka3335
      @nirmalamadushanka3335 5 лет назад +1

      @@FriotecAVAC ohhhh ok ok now understand did you only change the uln and expansion after that is it work fine

    • @FriotecAVAC
      @FriotecAVAC  5 лет назад +1

      Yes... But sometimes it's the fan motor in short circuit putting down the 15 vdc and than U4 comes out.

  • @87409
    @87409 5 лет назад +1

    Comprendo que su idioma sea Portuguez, el cual es muy bonito, pero ¿podría subtitularlo en Español? Si puede, el temas es de mi interés
    Saludos

  • @hebersilva3474
    @hebersilva3474 Год назад +1

    Boas pode passar o contacto se fizer favor

  • @87409
    @87409 5 лет назад +2

    Por favor en ESPAÑOL