    Our
    reception area has high ceilings of 5/6m we need to turn on the high
    ceiling mode as high fan speed alone is not enough to get warm air down
    to floor level.
    The controller suggests that high ceiling mode is Mode number 13 (23)
    followed by first code 0 then we have second code numbers of 01 (normal
    2.7m) or 03 (extra high >3.0).
    On our other floors setting option 03 actually reduces the fan output
    and you can hear the fan and airflow is less, setting it to 01 where you
    would expect it to be the least actually makes the fan speed up the
    fastest. Also on this controller there is an option for static pressure
    which is not available on the ducted units on the other floors so our
    reception ducted unit is clearly a diff unit.
    The issue is on the reception unit we cannot hear the fan anyway due to
    the height of the ceiling and the noise level from the busy street so we
    need to know the correct settings as they do not seem to correspond to
    what its saying in the field settings. Even the engineers when they come
    out are confused by this and say that code 03 is high ceiling mode even
    though this slows the fan down even slower. As the FM for this site I
    am having to resolve this myself now due to the call out costs.
    Anyone any idea on what is the correct settings? The system is about 6
    years old now and is a big VRV system with some areas having localised
    controllers - the reception area included. The rest are controlled from
    itouch controllers in the riser cupboards.

  • @babaolowo35
    @babaolowo35 Год назад

    THANK you

  • @babaolowo35
    @babaolowo35 Год назад

    THANKS

  • @fridgydownunder6734
    @fridgydownunder6734 4 года назад

    Daikin SG, can you please help me to get a Daikin mobile tool device?

  • @thucmrt
    @thucmrt 5 лет назад

    Can this able appli for fxmq50 pve?

    • @DaikinSG
      @DaikinSG  5 лет назад

      Hi, not possible as the setting is different.

  • @franciscojaviergarciaruiz5295
    @franciscojaviergarciaruiz5295 3 года назад

    Tengo una alarma en el test con una llave y no me deja que activa el arranque del compresor

  • @KHICHI_BANNA
    @KHICHI_BANNA 6 лет назад

    Hello can you help me in hacking the ac controller ...it does not on ... only a red light keeps blinking ...pls

    • @Drop_Gearz
      @Drop_Gearz 5 лет назад

      red light blinking seem unit have alarm, if not mistaken