Heat Pump System FAILED In FREEZING Temps!!

Поделиться
HTML-код
  • Опубликовано: 27 сен 2024
  • - SUPPORT THE CHANNEL -
    www.patreon.co...
    - Check out @TruTech Tools, LTD -
    www.trutechtoo... (Use promo code “QUALITYHVAC” to save 8%)
    - HVAC TACTICAL -
    hvactactical.com/ (Use Promo Code "QUALITYHVAC" to save 10%)
    - FOLLOW ME -
    Instagram: @qualityhvacr
    - BUSINESS INQUIRES -
    qualityhvacrtn@gmail.com
    - TOOLS I USE -
    hilmor lineset cleaning kit:
    trutechtools.c...
    RLS Refrigerant Press Tool Kit:
    www.trutechtoo...
    Veto Pro Pac MB5B Tool Bag:
    trutechtools.c...
    Supco Jumper King:
    trutechtools.c...
    Fieldpiece Job Link HVACR Charge & Air Kit: www.trutechtoo...
    Fieldpiece VP87 Vacuum Pump:
    trutechtools.c...
    Fieldpiece MR45 Recovery Machine:
    trutechtools.c...
    Fieldpiece Hose Kit:
    trutechtools.c...
    Fieldpiece SR47 Refrigerant Scale:
    www.trutechtoo...
    Solderweld Brazing Kit:
    trutechtools.c...
    Fieldpiece SC480 Meter: www.trutechtoo...
    Fieldpiece SC680 Meter: www.trutechtoo...
    Fieldpiece SM380V Digital Manifold: www.trutechtoo...
    Supco Magnetic Umbrella: www.trutechtoo...
    Supco Coolpressor:
    trutechtools.c...
    Supco Jumper King:
    trutechtools.c...
    Fieldpiece DR82 Leak Detector:
    trutechtools.c...
    #qualityhvacr #hvac #service
  • КиноКино

Комментарии • 56

  • @joefrance6599
    @joefrance6599 8 месяцев назад +4

    Great info! I am in Minnesota, and we don't usually, in my area at least, don't see a lot of heat strips. Thanks, and keep up the great work!

  • @Redactedbud
    @Redactedbud 7 месяцев назад +1

    Your truck is always so well kept man. Nicely done. I hope to keep my stuff the sane when the time comes.

  • @dnell6854
    @dnell6854 8 месяцев назад +5

    Do a video on how to troubleshoot sequencers,Thanks guy

  • @cyclingfan2010
    @cyclingfan2010 8 месяцев назад +1

    I’d very much appreciate a “101” circuit video. Thanks!
    Todd

  • @ThomasWalker-m2y
    @ThomasWalker-m2y 8 месяцев назад +10

    There's really no need for heat sequences anymore use a contactor. Many manufacturers have got away from them and only use contactor now.

  • @OcRefrig
    @OcRefrig 8 месяцев назад +1

    Good vid. in a pinch u can use contactors & delay on make time delays.

  • @jharris4480
    @jharris4480 8 месяцев назад

    Thanks for making this video. I'm new to this trade and I'm writing down all these nuggets of info as I hear them. Appreciate it.

  • @ryryk6977
    @ryryk6977 7 месяцев назад +1

    I gotta show this to my Canadian government that think heat pumps are gunna last in -40 temps lol

  • @masonanderson4859
    @masonanderson4859 8 месяцев назад

    I love the consistent posting! Keep it up

  • @billcv80
    @billcv80 8 месяцев назад +4

    Mention/document the way the power is supplied to the fan on most heat kits to ensure it runs until heat strips are de-energized

    • @jerrykorman7770
      @jerrykorman7770 8 месяцев назад

      I like to program the stat to run 30 s after the heat kit / strips are deenergized when demand is satisfied. Maybe the kit will last longer as there isn’t residual heat when the blower stops

  • @bnasty267
    @bnasty267 8 месяцев назад +2

    Double throw on a relay/contactor just means that it has contacts for normally open (NO) _and_ normally closed (NC). Normally closed would be used so that the load being switched is OFF when the contactor has power (reverse the low voltage signal, basically.) This isn't really useful for heat strips where you want the 'call' to turn them on, so DT isn't a common configuration.

  • @PRIMANIAGAHVAC
    @PRIMANIAGAHVAC 7 месяцев назад +1

    Nice bro. Heat conditioning

  • @FPHA697
    @FPHA697 8 месяцев назад +1

    That’s an old heil horseshoe unit 10 seer. Great video brother.

  • @chrisnavarro4144
    @chrisnavarro4144 3 месяца назад

    Can you show us or make a video on how to wire a heat pump with heat strip?

  • @shellz5437
    @shellz5437 8 месяцев назад

    I wish you would go more in detail of what do you do step by step why do you do it and what are you checking and same with the install vids please do a step by step install i really want to learn please and thank you im obsessed with your vids

    • @shellz5437
      @shellz5437 7 месяцев назад

      @QuaIityHVACR. Omg honestly i didnt think you would respond i was looking at your tool bag 2023 version and i will love to have it filled with all your tools i looked it up and its almost 1.5k im saving up to get it and i just started in the hvac field did 2 yrs of hs and love everything about it and love your content so much love what you do and what you stand for shout out to you man for being the goat hvac tech on yt

  • @zesty2023
    @zesty2023 8 месяцев назад

    Interesting looking package unit.

  • @sermore77
    @sermore77 8 месяцев назад

    Great explaining sequencers

  • @eagletek1
    @eagletek1 8 месяцев назад

    Great job

  • @richwuttunee4734
    @richwuttunee4734 8 месяцев назад

    Yes do more controls 👍👍👍

  • @woodystokes1543
    @woodystokes1543 8 месяцев назад

    Toooo cold 🥶 brrrrr

  • @thesilentonevictor
    @thesilentonevictor 8 месяцев назад

    Good job Zack

  • @zekenzy6486
    @zekenzy6486 8 месяцев назад

    Great Video. Thank you for sharing.

  • @JacksonAndrews-gn8bk
    @JacksonAndrews-gn8bk 8 месяцев назад

    Those old dogs last a long time. Supply and return are on opposite sides from normal.

  • @JohnDoe-nt3rm
    @JohnDoe-nt3rm 8 месяцев назад

    Great video!

  • @brushben22
    @brushben22 8 месяцев назад

    These videos make me love California

  • @subbusubrahmanyam2472
    @subbusubrahmanyam2472 8 месяцев назад

    Super Sir Very Talated

  • @user-ot3zk5me5l
    @user-ot3zk5me5l 8 месяцев назад

    What temperature are heat pump good until in your experience?

    • @Balticblue93
      @Balticblue93 8 месяцев назад +2

      This is very difficult to answer. I am an HVAC dealer and technician. Older heat pumps are generally good to 32 degrees and then the furnace will take over. Depending on how deep your pockets are and how big your home is, you can basically get systems that technically can reach -22 degrees, but big bucks to get those. If you have natural gas, you get a decent Heat pump that can go to around 5 degrees or even -5 and have a furnace take over or heat strips. I am not a fan heat strips and they are not really used in Colorado. Nearly all my customers get a dual-fuel setup, if they have solar that helps offset some of the electrical usage, but it warmer and less expensive to run a natural gas furnace. We don't do package units unless you consider an RTU a package unit. It is all about how well your home is insulated, your windows, size of home and how warm you would like your home. But again, I only sell dual-fuel setups here in Colorado. We have to derate them for altitude but variable speed systems are our primary systems that are sized correctly with a proper load calculation for heat and cooling, not just your basic Manual J.

  • @IndusTrack
    @IndusTrack 8 месяцев назад

    Great!

  • @wazwrong5539
    @wazwrong5539 8 месяцев назад

    they obviously don't get maintenance lol

  • @malcolmwhite821
    @malcolmwhite821 8 месяцев назад

    Well us California folks have never been in that weather. Lol

  • @AustinMichael
    @AustinMichael 8 месяцев назад

    That old filthy thing looks like it needs replaced.

  • @TheSimba86
    @TheSimba86 8 месяцев назад +2

    put something on your face, all that red and pink screams "almost frostbite"

  • @williamgildea8348
    @williamgildea8348 8 месяцев назад +19

    I would love a video on sequencer operations. Don’t work on a lot of heat pumps in NJ. Also troubleshooting would be great

    • @mattbilodeau2433
      @mattbilodeau2433 8 месяцев назад +3

      Yessss I would also love a troubleshooting video on this

    • @That01guyT
      @That01guyT 8 месяцев назад +2

      AC service tech channel. Get the book too

    • @grandinosour
      @grandinosour 8 месяцев назад +8

      A heat sequencer is nothing more than a cheap time delay relay (contactor). Used to prevent all the heat elements from coming on at once to preventing an excessive voltage drop on the main line, affecting the blower motor attempting to start and maybe even blowing the pole transformer.
      They use thermo-discs that activate over time from a little heater (coil) mounted in the base. They will fail more often than a contactor.

    • @mattbilodeau2433
      @mattbilodeau2433 8 месяцев назад

      @@That01guyT which book I have his mini split book and refrigerant charging procedures book

    • @That01guyT
      @That01guyT 8 месяцев назад +1

      @@mattbilodeau2433 I thought both of them had chapters or operation on heat pumps. I read them a while ago but remember learning a lot from them. I could be thinking of a different book too

  • @myHVAClife
    @myHVAClife 8 месяцев назад +1

    Time to replace that old unit, and always cycle the electric heat down with your amp meter attached to make sure the blower does not cycle off until all the strips cycle off. Don't want any coils burning with no air flow, if it is wired wrong that will happen. A lot of old units use a back jumper off the sequencer to energize a blower speed in EM. HEAT mode if the tstat does not call for G in that mode.

  • @CREATIVE.OPTIMISM
    @CREATIVE.OPTIMISM 8 месяцев назад +2

    YES GO INTO CONTROLS ‼️

  • @rbfour5
    @rbfour5 8 месяцев назад +1

    I really enjoy your videos. Being a longtime HVAC guy myself having worked in wholesale distribution, contracting and for manufacturing it’s always refreshing to see REAL service and troubleshooting skills. The mini split manufacturer I work for definitely appreciates contractors such as yourself. Keep up the good work!

  • @chuckrafiki8649
    @chuckrafiki8649 7 месяцев назад +1

    Glad to see an HVAC repair done honestly! So many wouldve just told the guy he needs a new heat kit and billed a very high charge and maybe he wouldnt have even suspected .

  • @josephwhite373
    @josephwhite373 8 месяцев назад

    Replace sequencers with comtactor and relay 🤷‍♂️

  • @BartlettTFD
    @BartlettTFD 8 месяцев назад

    It’s actually a thermal relay as an opposed to a magnetic relay.

  • @MariosACandRefrigeration
    @MariosACandRefrigeration 8 месяцев назад

    And that is how you fill up a work truck,you say this will never happen to me again,and you throw one of each in it.thanks for helping this people out,it takes guts.

  • @richardthomas1743
    @richardthomas1743 8 месяцев назад

    HEY! Good morning Zach and thumbs UP!

  • @GB.512
    @GB.512 8 месяцев назад

    The heat suhqencer r bad 😂 jokes! Good video

  • @dnell6854
    @dnell6854 8 месяцев назад

    My weakness!Great video

  • @steveblake8766
    @steveblake8766 8 месяцев назад

    thumbs up

  • @robalexander7348
    @robalexander7348 8 месяцев назад

    Nice work Zac, it sure was a cold day over there for you, and nice service to your customer. here yesterday ( Sun ) it reached 33 c ( 91f) so i had my Daiken A/C on cooling 24c 👍 Au

  • @jroberts3428
    @jroberts3428 8 месяцев назад

    I dont even know what a heat sequencher is..