Brazing TXV External Equalizing Tube onto Evaporator Coil Suction Line! Replacement of TXV

Поделиться
HTML-код
  • Опубликовано: 8 фев 2025
  • This is how to un-braze and braze in a new TXV external equalizing tube into the Suction line without closing off the tube. I also explain how to install a 1/4" flare and nut onto the tube if you are not able to purchase the correct TXV with 1/4" flared tubing for that model evap connection.
    Tools Used In The Video
    Air Acetylene Torch setup - amzn.to/2aQalsb
    15% Silver Brazing Rods - amzn.to/2gVLyLc
    Uniweld Cap-N-Hook and #2 Tip Oxy Acetylene Torch Setup - amzn.to/2STp3Fe
    Uniweld Oxy Acetylene Torch Setup #1 &#2 Tip - amzn.to/3WZaPmN
    #2 Tip for Oxy Acetylene Torch - amzn.to/2SPDaeD
    Cap-N-Hook Tip for Oxy Acetylene Setup - amzn.to/2MbhpUk
    40cu B Tank to 10cu MC Tank Acetylene Tank Fitting - amzn.to/2GxZZPi
    Nitrogen Regulator - amzn.to/2bXdR5f
    Uniweld NitroVue Flow Regulator - amzn.to/2GnsaAo
    Uniweld Nitrogen Flow Meter - amzn.to/2brvoBg
    Bernzomatic Trigger Start Lighter Propane/Mapp Gas - amzn.to/2vit0cv
    Uniweld Soft Flame Sweating Torch Setup for Acetylene - amzn.to/2DyzRD8
    Flint Spark Ignitor - amzn.to/2L3P2u9
    Stay Brite #8 Silver Bearing Solder and Flux - amzn.to/2XIDJsY
    Aluminum Braze Rods - amzn.to/2IGNMuW
    ▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬
    Our Related Videos/Articles
    • HVAC Brazing In The Ev...
    • HVAC Brazing Basics Wi...
    • Brazing and Leak Testi...
    • Brazing Copper Tubing ...
    • Oxy Acetylene Brazing,...
    • Oxy Acetylene Brazing-...
    ▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬
    Our HVACR Educational Books, E-Books, Workbooks, Cards, Posters, and PowerPoints:
    All Our Educational Products on Our Site: www.acservicet...
    All Our Educational Products on Amazon: amzn.to/48pDd82
    Mini Split Book and E-Book on Our Site- www.acservicet...
    Mini Split Paperback on Amazon- amzn.to/3ytHJSs
    Mini Split Paperback on TruTech Tools- www.trutechtoo...
    Refrigerant Charging Book and E-Book: www.acservicet...
    Refrigerant Charging Paperback on Amazon: amzn.to/46xTeHf
    ▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬
    Our HVACR Online Resources!
    Our HVAC Calculators: www.acservicet...
    Our Newest Articles: www.acservicet...
    Try our HVAC/R Quizzes! www.acservicet...
    Our Other Resources: www.acservicet...
    ▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬
    Tools Used in Our Videos!
    Tool Links on Our Site: www.acservicet...
    Our Tool List on Amazon: www.amazon.com...
    Support the Channel by purchasing tools through TruTech Tools!
    Use this link www.trutechtoo...
    Save 8% at checkout using code "acservicetech"
    ▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬
    Follow Us On Our Social Media & Podcasting Channels!
    Patreon: / acservicetech
    Facebook: / acservicetech
    Instagram: / acservicetech
    X: / acservicetech
    LinkedIn: / ac-service-tech-llc
    Tiktok: / acservicetech
    Spotify: open.spotify.c...
    Apple Podcasts: podcasts.apple...
    ▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬
    ⚠️ Disclaimer:
    Information in this video is intended for educational purposes only. Any work related to the topics in this video should be performed by licensed technicians or by apprentices under the supervision of licensed technicians. AC Service Tech LLC is not responsible for any possible damages or injuries caused by the use or misuse of any information provided.
    ▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬
    #hvacr #hvacr #hvactrainingvideos #hvactraining #hvactraining101 #acservice #acservicetech #lineset #brazing #braze #copper #tubing #refrigerant #evaporatorcoil #coil #brazingmachine
    ▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬
    Shop through Amazon! Your Purchases through Amazon provide a means for channels such as mine to earn advertising fees from all purchases after clicking through. Prices are the same as normal.

Комментарии • 40

  • @lyotoarellano
    @lyotoarellano Год назад +2

    Man this video is exactly what I was looking for. Its the only helpful video on yt on this. Thanks again for all the info and knowledge!!

  • @kennethdandurand3472
    @kennethdandurand3472 4 года назад +7

    If you noticed, the old tube was inserted about 1/4 inch. That is how to keep the capiallary sized tube from getting soldered shut. When you are done and it has cooled a bit, blow in the end to see if your breath goes in or not. Just sayin!

  • @acservicetechchannel
    @acservicetechchannel  7 лет назад +1

    Our Inverter Mini Split Resources:
    Mini Split Book on Our Website- www.acservicetech.com/mini-split-book
    Mini Split Paperback on Amazon- amzn.to/3ytHJSs
    Mini Split Paperback on TruTech Tools- www.trutechtools.com/BooksGuides?aff=8
    Mini Split E-Book on Google- play.google.com/store/books/details?id=HN-iEAAAQBAJ
    Mini Split E-Book on Apple- books.apple.com/us/book/id6445178399
    Our Single Speed and Two Speed Air Conditioning Resources:
    My Paperback and E-Book: www.acservicetech.com/the-book
    My Paperback: www.amazon.com/shop/acservicetech
    Read the book reviews on Amazon!
    Check out our new Articles at www.acservicetech.com/articles
    Support the Channel by purchasing tools through Tru Tech Tools!
    Use this link www.trutechtools.com/?Aff=8
    Save 8% at checkout using code "acservicetech"
    Tool List- www.amazon.com/shop/acservicetech
    Support- www.patreon.com/acservicetech
    For those that are looking for the tools used in the videos: (Linked Below)
    Here is a link to the air acetylene torch setup- amzn.to/2aQalsb
    Here is a link to the UEI DL389 Multimeter used in the videos- amzn.to/2av8s3q
    Here is the link to the Fieldpiece SDMN6 Dual Pressure Testing Manometer with Pump-amzn.to/2jyK5Ka
    Here is a link for the Supco Magnet Jumpers amzn.to/2gS4h6z
    Here is the link for the Irwin Wire Stripper/Cutter/Crimper amzn.to/2dGTj2V
    Other tool links can be found in the video description section.
    ACSERVICETECH is a participant in the Amazon Services LLC Associates Program, an affiliate advertising program designed to provide a means for sites to earn advertising fees by advertising and linking to Amazon.com.

  • @user-kp4yp6g9
    @user-kp4yp6g9 Год назад +1

    Nice work

  • @briansmyla8696
    @briansmyla8696 Год назад +1

    I know this video is old, but I'd like to point out that Sporlan's instructions for the location of the equalizing tube is downstream of the sensing bulb. The installation of this bulb was incorrect, as it was upstream of the bulb. Also, the bulb and tube should be installed on a horizontal run. The tube should be installed on the top of the horizontal run, and the bulb should be installed at the 3, 9, 4 or 7 o'clock positions on the horizontal run. Sporlan's instructions.

  • @stevestgeorge8393
    @stevestgeorge8393 2 года назад +1

    Equalising line after phial bulb. Compressor side.Always use 1/4” copper for equalising line as sometimes people use capillary and they can block up.

  • @jimbola77
    @jimbola77 8 лет назад +2

    very nice presentation!!!

  • @scottytomcat4267
    @scottytomcat4267 7 лет назад +1

    Absolutely great video good helpful tips,Keep them coming and thank you

  • @peterm4978
    @peterm4978 8 лет назад +2

    this guy was awesome very good!

  • @HealthInfo
    @HealthInfo 8 лет назад +2

    Very informative and useful.

  • @johnhawthorne7554
    @johnhawthorne7554 Год назад +1

    How about a video showing the best way to replace a heat pump reversing valve ?

  • @drummerdem50
    @drummerdem50 8 лет назад +2

    Thanks

  • @earthsign28
    @earthsign28 4 года назад +1

    What happens if you crimp or block the equalization tube? What will my pressures look like?

  • @raviyadav8743
    @raviyadav8743 4 года назад +1

    Can we close the external equalizer point..What will happen

  • @iakovgubanov
    @iakovgubanov 3 года назад +1

    Hello Craig. Thank you for the video. I have a question. Can I cut the external equalizer, And braze the capillary port off? I've bought the TXV and planning to install it on my 4-ton system. r22. But I check the evap coils and there is no port to put the equalizer. One man told me that if I don't have a port on the evap coils for the external equalizer I can cut and braze it off. Is that correct? How it will affect the TXV. He did that on his house and it works fine. Maybe better to buy TXV without an external equalizer. Thank You.

  • @La2venida
    @La2venida Год назад +1

    How far Should capellary go into the pipe

    • @acservicetechchannel
      @acservicetechchannel  Год назад +1

      1/8" to maybe 1/4" just so you dont have the braze get pulled up into the hole in the end of the tube by trying to braze it in, thanks!

  • @icebeary4886
    @icebeary4886 5 лет назад +1

    Do the distance between sensor bulb and equilizer line; and location on the suction line (which one should be close to evaporator) matter? thank you

    • @acservicetechchannel
      @acservicetechchannel  5 лет назад +1

      Techs tend to make a big deal of this but I have seen quite a few manufacturers with preinstalled txv's have the order of the bulb and external equalization line flip flopped with no problem. usually the equalizer tube is downstream of the bulb, thanks!

  • @HumanRightsRevolutin
    @HumanRightsRevolutin 5 лет назад +1

    TYVVVM

  • @apr9286
    @apr9286 6 лет назад +1

    Can you cut the equalizer tube and use a coupling and insert the new tubing then braze it?

    • @acservicetechchannel
      @acservicetechchannel  6 лет назад +1

      Absolutely, I have done it before but you get one shot at it to get in and out quick in order to not clog the cap tube, thanks

    • @troymason4799
      @troymason4799 4 года назад +1

      i like the flare idea. i had a really hard time brazing in the E tube recently because it was inside the cabinet near the pan and i was burning the pan. maybe i should have slid the coil out

  • @timrob0420
    @timrob0420 5 лет назад +1

    What if all symptoms look like TXV, high superheat, high subcooling, low suction... yet when you put TXV bulb in warm water Superheat does drop?

    • @acservicetechchannel
      @acservicetechchannel  5 лет назад +3

      That means that the bulb has a partial charge only. It doesn't have enough to open the valve enough during normal operation so confirmation it is a bad txv, thanks!

  • @obet191
    @obet191 7 лет назад +1

    can you install a 3 ton carrier coil on a 3 ton payne or is there some sizing that has to be done

    • @acservicetechchannel
      @acservicetechchannel  7 лет назад +1

      Certainly but you need to make sure the metering device is for 3 ton and that the building's heat load will be handled by 3 tons of ac, thanks!

  • @popsmccartney435
    @popsmccartney435 8 лет назад +1

    What size tip are you using ?

    • @acservicetechchannel
      @acservicetechchannel  8 лет назад +1

      That was an A6 or A8. The tip needs to be big enough to heat the large pipe as well but keep the heat back from melting the external equalization tube. Thanks Pops McCartney!

  • @rocker8692
    @rocker8692 7 лет назад +1

    I think they use copper cause it conducts the heat too

    • @acservicetechchannel
      @acservicetechchannel  7 лет назад +1

      Yes that is possible. Some manufacturers will supply stainless but most are copper, thanks!

  • @michlgilbertclements6178
    @michlgilbertclements6178 6 лет назад +1

    What if you plug the external equalizer

    • @acservicetechchannel
      @acservicetechchannel  6 лет назад +1

      Exactly! You won't know until you run the system. That is why I tell students and techs to practice this procedure with just a piece of tubing that is open that they can test afterward before trying this in the field, thanks

  • @SteveO.69
    @SteveO.69 5 лет назад +2

    Why where you not using nitrogen while brazing that?

    • @acservicetechchannel
      @acservicetechchannel  5 лет назад +4

      This was just an in the shop testing coil I used for teaching, thanks!