How individual compound is identified in GCMS

Поделиться
HTML-код
  • Опубликовано: 19 окт 2024

Комментарии • 42

  • @elhermeneutico
    @elhermeneutico Месяц назад +1

    My supervisor had me manually identify the peaks and calculate their respective areas one by one. Is there any difference between this method and the one you are describing here? I'm using the same version of the Agilent Data Analysis software.

  • @iqbali8944
    @iqbali8944 7 месяцев назад +3

    Can we identify compound on the basis of retention time ?

    • @shirwansany8706
      @shirwansany8706  7 месяцев назад

      With GC/MS, you can identify a compound with (2) Mass spectra of the compound and (2) retention time.

    • @AzharKhan-ww3dl
      @AzharKhan-ww3dl Месяц назад

      Can you make the video on the GC chrromo calculation

  • @scientiainquisitor5391
    @scientiainquisitor5391 Год назад +3

    Hi there are multiple compounds detected per peak So which one will be the compound corresponding to the peak. Are all the compounds are said to be present in the single peak (whichever is detected).

    • @rahanjdas5572
      @rahanjdas5572 5 месяцев назад

      hello did you get the ans for this question???? i am also confused

    • @rajendraregmi5407
      @rajendraregmi5407 5 месяцев назад

      I have the same question as well.

    • @scientiainquisitor5391
      @scientiainquisitor5391 4 месяца назад +1

      @@rahanjdas5572 nope

    • @rahanjdas5572
      @rahanjdas5572 4 месяца назад

      @@scientiainquisitor5391 thanks for letting me know

    • @YoHaAnN666
      @YoHaAnN666 2 месяца назад

      You'll never be able to be 100% sure. Here, the mass fragmentation pattern (and retention time I guess) is (are) compared to the library to find the best matches. You can see a value to the right of the proposed molecules (in the column called "qual" for "quality") which is a percentage score. The closer it is to 100, the better the match between the data acquired and the library. Also, here are displayed only the 3 best results from the library but there are more for sure. In that case, the quality score is high enough to be fairly certain of the identity of the molecule, but sometimes, when the sample is more complex (and when you have co-elution of several compounds), the library struggles to find good matches and it can be useful to consider more possible matches.

  • @MahnoorUsman-je7te
    @MahnoorUsman-je7te 4 месяца назад

    I have a question that how can we get this gc ms library???? and which software are you using??? Thank you in advance.

  • @shivaaleyasin6256
    @shivaaleyasin6256 2 года назад +1

    thank you in advance for your explanation. I don't have experience working GC-MS .after watching in the video I have a question . output of GC-Ms is chromatogram that shows abundance versus M/Z that molecular weight is calculated . how to calculate concentration of compound?

    • @shirwansany8706
      @shirwansany8706  2 года назад +2

      Hello Shiva, thank you for the question. I have uploaded a video on determining the concentration of compounds via the GCMS here: ruclips.net/video/TGqoPLkOnA4/видео.html
      Hope it answers your question. Thank you for watching this video.

  • @nazishakhtar2
    @nazishakhtar2 Год назад

    Wslam sir! I have to compare compounds in plants of 4 different groups, is GCMS can interpret the different concentrations of the same compound in different groups of plant

    • @shirwansany8706
      @shirwansany8706  Год назад

      Salam, GCMS can identify the volatile compounds in the plant. Here is the strategy:
      1. Analyze the plant extracts via GCMS. Determine the detected compounds, qualitatively.
      2. Based on the detected compounds, purchase the compound standards.
      3. Analyze the standards via GCMS and set up a calibration curve for each standard.
      4. Analyze the plant extracts. Then quantify each compound using the calibration curve.

  • @rajendraregmi5407
    @rajendraregmi5407 5 месяцев назад

    When you select some peak so many compounds were shown, how to conform the given peak is of respective compound

    • @shirwansany
      @shirwansany 5 месяцев назад

      There are a few ways to confirm.
      1. Confirm with the standard of the compounds. Run a standard of the compound, record and compare the mass spectra.
      2. Based on the mass spectra of the compound, confirm the mass of ion fragments

    • @rajendraregmi5407
      @rajendraregmi5407 5 месяцев назад

      @@shirwansany I mean when you click some peak many mass spectra is shown? I need to identify Z-7-dodecyl acetate ? how can i do that? Anyways thanks for your video.

  • @giuseppezedde4553
    @giuseppezedde4553 2 года назад

    Thanks so much for your explanation. I have a question for you. Is the mass spectrum sufficient to identify a compound or is it also necessary to have the IR, NMR and UV spectra?
    Thank you

    • @shirwansany8706
      @shirwansany8706  2 года назад +1

      Hi,
      It depends on the aim of the study as follows:
      1. Shall you need to identify a new compound, mass spectrum, IR and NMR are needed.
      2. Shall you need to confirm the presence of an already known compound, get the mass spectrum and verify it with the compound standard are recommended.
      Thank you for watching the video.

    • @giuseppezedde4553
      @giuseppezedde4553 2 года назад

      @@shirwansany8706 I thank you so much!

  • @samsoonmaharifa6687
    @samsoonmaharifa6687 3 года назад

    Walaikum mussalam sir
    The library is showing three hits
    What we have to consider, only the first hit alone or all the hits
    Because it shows different compound name
    If it is same we can take that without doubting, hit is showing three different compounds for a particular peak
    Please help me in this

    • @shirwansany8706
      @shirwansany8706  3 года назад

      Hi Samsoon. In my case, if the extract is crude, I don't consider the hits as the correct result. Then, I submit the sample to another detection method to identify the compound.
      If the extract is the pure one, we could possibly accept the first hit; however, please bear in mind, the FTIR only identifies the functional group, not the actual chemical compound.

  • @ismartiismarti-rj5gn
    @ismartiismarti-rj5gn 6 месяцев назад

    Thanks Dr Shirwan

  • @pentagc672
    @pentagc672 2 года назад

    which is this application name where we can buy this app, pls share this link.

    • @shirwansany8706
      @shirwansany8706  2 года назад +1

      Hello, this is Enhanced Data Analysis software from Agilent, which came together when we purchased the GCMS.

  • @shawonislam2724
    @shawonislam2724 Год назад +1

    Very helpful

  • @akiamini4006
    @akiamini4006 Год назад +1

    Very nice

  • @DurayStuffCrafts
    @DurayStuffCrafts 2 года назад

    How to calculate percentage by using giving data

    • @woba7166
      @woba7166 2 года назад +1

      You need to calibrate with known concentrations of compounds in question.

  • @TheMeemkim
    @TheMeemkim 3 года назад +2

    Thanks!

  • @syarifahyantiastryna104
    @syarifahyantiastryna104 Год назад +1

    Belajar lagi❤❤

  • @franklindebruin2074
    @franklindebruin2074 3 года назад

    Hi sir great video where can I get the software from I'm from south Africa thank you can you assist with software

    • @shirwansany8706
      @shirwansany8706  3 года назад

      Hello Franklin, I am using the Agilent OpenLab CDS Data Analysis software. It came with the HPLC instrument.

    • @pentagc672
      @pentagc672 2 года назад

      @@shirwansany8706 Agilent open lab software has using complex sir, i used above that software using friendly.

  • @technologywatch7619
    @technologywatch7619 Год назад

    Can show how to open sample data firtst/

  • @md.mahmudulhasan5905
    @md.mahmudulhasan5905 8 месяцев назад

    from Bangladesh

  • @shawonislam2724
    @shawonislam2724 Год назад

    Wow❤

  • @haaniaishaq4966
    @haaniaishaq4966 Год назад

    I need software plz share ur mail id

    • @shirwansany8706
      @shirwansany8706  Год назад

      Hello, this is Enhanced Data Analysis software from Agilent, which came together when we purchased the GCMS.

  • @shawonislam2724
    @shawonislam2724 Год назад

    Very helpful