    How often is stud framing perfectly flat? Even with our KERDI-BOARD building panel, that is designed to be flat, level, plumb and square--severe warping behind these sheets can have an effect when fastening the panels to framing. Check out this video to see how to shim the studs before fastening KERDI-BOARD if you run into extreme warping on your job!
    For further information on our products please visit our website:
    www.schluter.com
    Subscribe to our channel: / schlutersystems1
    Facebook: / schlutersystems
  • ХоббиХобби

Комментарии • 94

  • @NMranchhand
    @NMranchhand 6 лет назад +8

    Schluter gets fundamental marketing like no company in America does today: First spend your time making sure people can see you demonstrate enthusiastically how to correctly use your wonderful product product on the most-used, free video distribution network in the world. You would think it obvious wouldn’t you?
    I’m a beginner and I’m going to use Schluter because I KNOW I’m installing it correctly. I came to you initially through the widely-watched videoed of an NTCA tiler of vast experience named Sal DiBlasi who is high on Schluter products and frequently demonstrates their correct installation. And, man, is he ever a stickler for correct installation, even explaining the process of hydration as the reason for the detailed choice between modified and unmodified thinset for your flooring product. I suggest you would profit from an association with him and that he is a high quality NTCA Pro that would make you proud of it.
    Disclaimer: I don’t know Sal personally or anyone associated with him; only as a follower of his channel and as one whose questions he has graciously answered on RUclips.
    Thanks for your great videos.

    • @schlutersystems1
      @schlutersystems1  5 лет назад

      Thank you so much NMrachhand! Subscribe to our channel if you haven't already as we're constantly releasing new videos on new products to help make installation easier!

    • @ikust007
      @ikust007 4 года назад

      I agree with both you

  • @scottfgray
    @scottfgray 5 лет назад +14

    Thank you, so much for your great videos. Your products have a great reputation. I as a DIY'er truly appreciate the great instructional material you have in your channel. I know the pros learning to use your products have to, as well.

    • @schlutersystems1
      @schlutersystems1  5 лет назад

      So glad you enjoy them Scott Gray! Subscribe to our channel and get all the updates on when we release videos!

  • @T.E.P.
    @T.E.P. 3 года назад

    great job guys!

  • @460sw3
    @460sw3 6 лет назад +4

    Nice! I just completed the schluter innovation work shop part 1....and will definitely be using this method a lot, 100 plus year old houses that I remodel bathroom and showers in are NEVER straight, plumb, or square. This will save me a ton of time!

    • @schlutersystems1
      @schlutersystems1  5 лет назад

      Glad to hear you enjoyed the workshop 460 S&W! Check out our Part 2 when you can! We look forward to seeing you there.

  • @crittersintheyard3993
    @crittersintheyard3993 2 года назад

    so helpful, ty!

  • @ikust007
    @ikust007 4 года назад +2

    Splendide . I am doing this next weeks. Can I use that technic also for humidity-gypse (bathroom gypse)? Thank you very much

    • @schlutersystems1
      @schlutersystems1  4 года назад +1

      Hi!
      Thank you for watching! Our expertise is Kerdi-Board. So unfortunately we do not have any testing or details for you on wet shimming of gypsum board.

    • @ikust007
      @ikust007 4 года назад

      Schluter-Systems North America fait enough . I do all my bath/shower with Schlutter . But there is a section that I do with normal gypse .

  • @mariomedrano5210
    @mariomedrano5210 5 лет назад +6

    Thanks for the video. How long do we let the mortar in the 2x4 dry so I can screw on my wedge screws?

    • @schlutersystems1
      @schlutersystems1  5 лет назад +4

      Hi Mario! Thanks for the question. So, it's usually best to wait 3-4 hours or longer for the thin-set to firm up, depending on installation conditions.

    • @ikust007
      @ikust007 4 года назад +3

      Thank you for asking the question indeed

  • @kurtbilinski1723
    @kurtbilinski1723 Год назад +1

    It's much more fun when it's an outside wall, with lots of fluffy fiberglass insulation wanting to get mixed with the thinset. Also, the insulation can push the wall board away, so, like they sort of did here, you have to drive the screws in *just enough* to keep it square/flat/plumb until it hardens, then drive them home.

    • @neoasura
      @neoasura Год назад +1

      Your fiberglass insulation should be covered with plastic and stapled before applying any backerboard if you are doing a shower or bathroom

    • @romeobravo78
      @romeobravo78 Год назад +2

      @@neoasura The Kerdi board is waterproof. No plastic needed

    • @ericraymond1274
      @ericraymond1274 11 месяцев назад

      Do you wait til the thinset is fully hardened before screwing in all the way? Like basically wait til the next day?

  • @JorgeGomez-tl2mn
    @JorgeGomez-tl2mn 2 года назад +2

    Great video! I have a couple of questions: a) how do you level the backer board when the tub is not level? b) measuring the shims to level/plumb the wall; do you cut the shims from 2x4's and just cut shims for the large gaps?

    • @schlutersystems1
      @schlutersystems1  2 года назад +1

      Hi Jorge, Our Customer Service team would be best suited to discuss your project in a bit more detail. You can reach the team right here: 800-472-4588 (US) or 800-667-8746 (Canada). Thanks!

  • @feng3625
    @feng3625 4 года назад

    I am ready to use this Kerdi-board, but there are a few options for the thickness. which one I should select for my walk-in shower room?

    • @schlutersystems1
      @schlutersystems1  4 года назад +1

      Hi, great question! Check out this video for choosing the right thickness for your project. It should give you an overall understanding of which thickness and products to choose.
      ruclips.net/video/dc9kOTwpWJw/видео.html

  • @webdeveloper4742
    @webdeveloper4742 5 лет назад +1

    I have floor joists that are out of level. I wish to tile the floor. How do I level the joists and also what waterproof schluder system do I use for floor. Thanks David Also what size screws to use for wall as in your videos.

    • @schlutersystems1
      @schlutersystems1  5 лет назад +1

      Hi Absolute Plumbing & Heating. 1. Joists are typically crowned, therefore not level. If leveling is still needed, approval by a building official/engineer is needed to cut/modify. Please remember that all leveling must occur below our products, typically on substrate with use of patch self leveling underlayment (SLU). Follow manufacturer's requirements and recommendations for SLU installation. Please contact a design professional or structural engineer for further assistance.
      B. The DITRA uncoupling membrane with KERDI-BAND over the seams is generally recommended for waterproofing of floors. For further details, please see the appropriate detail in the Schluter DITRA Installation Handbook C. The screws we use are #6 size and 1.5", 2" or 3" long. The selected screws must be of sufficient length to reach a depth of at least 3/4" (20 mm) in wood studs and at least 3/8" (10 mm) in metal studs. Hope this helps!

    • @erikaslt
      @erikaslt 2 года назад

      Sister new wood. Or use self level.

  • @ajmueller5871
    @ajmueller5871 2 года назад +1

    Hi! About to install my first Kerdi shower/bath. What kind of thin set /Morter do we use for wet shimming? I know that we need unmodified for the front of the kerdi board.

    • @Pete5910
      @Pete5910 2 года назад +2

      Use Schluter All Set for everything. It’s a modified thinset mortar that’s approved for all Schluter applications

    • @schlutersystems1
      @schlutersystems1  2 года назад +3

      Hi AJ! Thanks for your question. Any Schluter thin-set can be used for wet shimming.

  • @chevyhighrider
    @chevyhighrider 2 года назад

    With this method though, how do you ensure your back wall is 90deg to your side walls? It’s also kind of difficult to shoot for a particular measurement between the two side walls such as 60”, the length of a typical Schluter Shower Tray. Thanks.

    • @schlutersystems1
      @schlutersystems1  2 года назад +1

      Hi there, bit hard to discuss and describe on socials, but we could set you up with your local Schluter rep if you'd like to discuss the details. If so, please send through your city and zip/postal code, and we'll send through the contact info for your rep. Thanks!

  • @kerryfrost5501
    @kerryfrost5501 5 лет назад +3

    At 3:50 you can see the board flex and reflex as you press the level against it

    • @Tilethoughts
      @Tilethoughts 5 лет назад +4

      I wet set all the time..gotta keep an eye on it and set a few screws before thinset sets up.

  • @olenaerhardt7725
    @olenaerhardt7725 4 года назад +1

    Is it important that the gaps are on those studs where we don't place Kerdi screws? Or only those where the screws are located should be leveled. Also could you tell what happens if there are some gaps? Will the tile fall or it will be just visual effect of not very leveled tiling? Thank you for the great film.

    • @schlutersystems1
      @schlutersystems1  4 года назад

      Hmmm... I think this is a good question for our Product Support team...
      US: 800-472-4588
      CA: 800-667-8746

    • @schlutersystems1
      @schlutersystems1  4 года назад +1

      Hmmm... I think this is a good question for our Product Support team...
      US: 800-472-4588
      CA: 800-667-8746

  • @tomsherwood327
    @tomsherwood327 2 года назад

    Will a non Schluter brand thin set mortar used to wet shim void the warranty? I know from the other comments it doesn’t matter if it is modified or unmodified. Thanks!

    • @schlutersystems1
      @schlutersystems1  2 года назад

      Hi Tom, a non-Schluter thin-set will not void the warranty, no. As long as our Handbook guidelines are followed, you should be all set. Thanks!

  • @Hector0478
    @Hector0478 5 лет назад

    What rated thin set do you use for the wet shim on studs? ANSI 118.1 or 118.11

    • @schlutersystems1
      @schlutersystems1  5 лет назад +4

      Hi Hector! The type of thin-set mortar used does not matter in this application since we are shimming to install KERDI-BOARD and not to achieve a bond. :)

  • @pulper11
    @pulper11 2 года назад

    Do you need to add the set to all studs or just the studs that are bowed inward? Ie if one or two studs are bowed inward and the rest are in plane and plumb, would it work just adding the thin set to the out of plane studs?

    • @schlutersystems1
      @schlutersystems1  2 года назад

      Hi there, In our video, we did all of the studs to give the best opportunity for success. If the other studs are in plane and plumb then, yes, you can just add thin-set to the out of plane studs. Hope this helps!

    • @pulper11
      @pulper11 2 года назад

      @@schlutersystems1 thank you

  • @Beech1900pilot
    @Beech1900pilot 4 года назад +1

    What kind of thinset? Modified? Unmodified? Is Schluter All Set good for this application? I think that is what is available at my local supplier.

    • @schlutersystems1
      @schlutersystems1  4 года назад +2

      Hi there, the type of thin-set mortar used does not matter in this case. The thin-set mortar is not used to bond the KERDI-BOARD to the studs, but as a shim. The KERDI-BOARD is secured to the studs using the screws. Hope this helps!

  • @cindycleland7026
    @cindycleland7026 7 месяцев назад

    I think mortar doesn't stick to vertical wood for very long. Won't it just fall later?

    • @schlutersystems1
      @schlutersystems1  7 месяцев назад

      Hi Cindy! Once the KERDI-BOARD is screwed in place, the thin-set will be secure and won't go anywhere. Hope that helps!

  • @capnjan9835
    @capnjan9835 3 года назад

    I was not looking forward to firring out the studs that, over the years, have deformed. They are perfectly strong, just somewhat cupped in places. This method will make it perfect.

  • @romeobravo78
    @romeobravo78 Год назад

    Can someone tell me the ratio of water to Allset to use for shimming. Tried and failed miserably yesterday - thinset way too runny and I don't want to waste more experimenting. Also, mix by hand?

    • @schlutersystems1
      @schlutersystems1  Год назад

      Hello! The thin-set needs to be "fairly stiff". Here is a video showing you what that looks like: ruclips.net/video/nebHq8N2i0Y/видео.html
      Hope that helps!

  • @stratojack1
    @stratojack1 3 года назад

    What kind of thin set are you using?

    • @schlutersystems1
      @schlutersystems1  3 года назад +1

      Hi Jack, the type of thin-set mortar used does not matter in this application since we are shimming to install KERDI-BOARD and not to achieve a bond. Hope this helps!

  • @dorishochbrueckner6389
    @dorishochbrueckner6389 Год назад

    What is the water to thinset ratio you used to wet shim? All you mentioned is "fairly stiff thinset".

    • @schlutersystems1
      @schlutersystems1  Год назад +2

      It sort of depends on how much you want to build up. You want it to be stiff enough to not just fall off, but not so stiff that it isn't workable. You could try the ratio mentioned on the bag for installing tile (not membrane) but adjust it to be just a little stiffer and see if that works. You are looking for a peanut butter type consistency. Depending on conditions, it may take a couple of tries to get it right. Hope this helps!

    • @dorishochbrueckner6389
      @dorishochbrueckner6389 Год назад +1

      Thank you. We used the low end of the tile setting amount and it worked great. We are setting the drain, pan, and bench this weekend. Appreciate all your educational videos.

    • @schlutersystems1
      @schlutersystems1  Год назад

      Awesome--thanks for your support! 🍊

  • @animateddepression
    @animateddepression 2 года назад

    Wish I’d known about this trick months ago.

  • @itninja9503
    @itninja9503 4 года назад +1

    Is this process applicable to walls with Metal Studs?

    • @schlutersystems1
      @schlutersystems1  4 года назад +1

      Hi there! Metal studs should not need shimming like wood studs because they are made to be uniform in size and shape. However, if there is variation in the metal stud that needs to be addressed, we would not recommend wet-shimming. We would suggest contacting the stud manufacturer for their input.

    • @itninja9503
      @itninja9503 4 года назад

      @@schlutersystems1 problem is the shoddy original construction. This is for a refit

    • @schlutersystems1
      @schlutersystems1  4 года назад

      You can give us a call to see how we can help! 800-472-4588

  • @12dollacigarette
    @12dollacigarette 5 лет назад +2

    Will the thinset rot the stud over time?

  • @angelahamilton4784
    @angelahamilton4784 3 года назад

    How can I install a niche over wet shim walls?

    • @schlutersystems1
      @schlutersystems1  3 года назад

      Hi Angela, please contact our Product Support team to discuss.
      US: 800-472-4588
      CA: 800-667-8746

  • @helchinzo
    @helchinzo Год назад

    Hmmm. I would fix the framing as much as possible first. What would happen to criticall finish dimensions ESPECIALLY tolerances for fixture trims. This seems like a convenient but very random way of solving a framing issue. Especially if the rogue stud were protruding into the space. Id also recommend insulation in those wall cavities. Ouch, that could get a bit messy once you start sticking those mud shims to the studs. Use a laser and fix your wall

    • @schlutersystems1
      @schlutersystems1  Год назад

      Hi there! Thanks for the comments. Insulation in certain instances is for sure a good idea. Any time you can fix the framing, that's a good way to go as well. In this case, the other side of the wall had drywall installed already, so wet shimming was the better option. Using KERDI-BOARD to wet shim is just another option that may be more convenient in some situations and is fairly quick to do and gives that nice flat wall you need for your trims and such. Hope this is helpful!

  • @ejcsds
    @ejcsds 3 года назад

    Whats the minimum that you would not address with wet shimming?

    • @schlutersystems1
      @schlutersystems1  3 года назад

      Hi there, any time the studs are off this method can prove helpful. 😊

  • @quintriggins6557
    @quintriggins6557 5 лет назад

    Modified or unmodified to wet shim?

    • @schlutersystems1
      @schlutersystems1  5 лет назад +2

      Hi there, the type of thin-set mortar used does not matter in this case. The thin-set mortar is not used to bond the KERDI-BOARD to the studs, but as a shim. The KERDI-BOARD is secured to the studs using the screws. Hope this helps!

    • @quintriggins6557
      @quintriggins6557 5 лет назад

      @@schlutersystems1 Thanks. That makes sense.

  • @grntchstrmdws
    @grntchstrmdws 2 года назад

    You did not specify the kind of thinset used, modified or unmodified. My concern is that the wood will suck water out of unmodified
    thinset. Perhaps it is of no consequence in this application. I just want to get it right.

    • @mccarseat
      @mccarseat 2 года назад

      In other comments Schluter answered saying it doesn't matter what kind of thinset you use since it's only being used to shim, not for actual bonding to the board. So personally i used modified thinset for the reason you stated and it worked out great. When I called them to ask they also confirmed it did not matter what kind of thinset.
      Disclaimer: I'm not a professional, just a DIYer.

    • @schlutersystems1
      @schlutersystems1  2 года назад

      Hi there! It doesn't matter what kind of thin-set you use to wet shim because there is no concern about the bond here. Hope this helps!

  • @mrappe51
    @mrappe51 Год назад

    Why do they mention unmodified. I had to go buy unmodified when I already have another brand of modified thinset

    • @schlutersystems1
      @schlutersystems1  Год назад

      Hi there, Here's our position on the use of other manufacturers’ thin-set mortars:. We have no control over the formulation of other manufacturers’ products and therefore cannot guarantee consistent, positive results with their modified thin-set mortars when installing tile to Schluter® boards and membranes. Our customer support team is happy to discuss this further with you, if you like:
      US 800-472-4588
      CA 800-667-8746

  • @Beech1900pilot
    @Beech1900pilot 4 года назад

    Me again. Question: is there a limit to the kind of gap that can be shimmed using this method? I have a stud that appears to be quite a bit out of plumb. Maybe up to an inch over 8 feet.

    • @schlutersystems1
      @schlutersystems1  4 года назад +1

      Hey there, mind giving our support team a call to discuss your unique project? Always good for us to have an exact sense of your project in order to provide the correct advice. USA 888-472-4588 or Canada 800-667-8746. Thanks!

    • @olenaerhardt7725
      @olenaerhardt7725 4 года назад

      What I've learned from some films about Kerdi-Board the allowed limit for those gaps is about 1/8".

    • @Beech1900pilot
      @Beech1900pilot 4 года назад +4

      Just an update if anyone is interested. I ended up using a combination of actual wooden shims.plus wet shimming to get my wall plumb for tiling. Must have done something right cause the finished product looks great!

    • @kurtbilinski1723
      @kurtbilinski1723 Год назад

      I'd say maybe 1/4" or so. More than that it's more likely to crack when the screws are tightened down. Just my opinion though.

    • @AlwaysHopeful87
      @AlwaysHopeful87 4 месяца назад

      Thanks for the follow up. @@Beech1900pilot

  • @andyjohnston1646
    @andyjohnston1646 2 года назад

    Why not just use drywall shims? Quicker, cheaper, easier & no waiting for them to dry.....

    • @schlutersystems1
      @schlutersystems1  2 года назад +1

      Hi Andy!
      Thanks for your question. The nice thing about using thin-set is that it is more precise and does not leave any gaps throughout the length of the stud. You can also do it all at one shot. Drywall shims would be another acceptable option, especially if you need to use them to save time, but you must be careful not to leave any unsupported spaces and, in some instances, it could take longer to try and get each separate stud shimmed out individually.
      Hope this helps!

  • @douglassandstrom6314
    @douglassandstrom6314 7 месяцев назад

    Sucked right in

  • @ernst7704
    @ernst7704 3 года назад +3

    or you can use drywall shims and screw board on the same day

  • @stevezack6077
    @stevezack6077 7 месяцев назад

    Lets wait four days for mortar to dry instead of putting a board in there

  • @williammingey961
    @williammingey961 4 года назад +3

    Theres not enough of mud in contact w board itll chip away n cause movement later .why not use wood shims and nail no moisture no rot no wetness no mold n wont chip away

  • @corypatrick9916
    @corypatrick9916 4 года назад

    Andy seems like he used to strike out playing kickball. Probably rocked the math league though

  • @antonpishchik
    @antonpishchik 3 года назад +2

    Go to home depot
    Buy wall spacers sold for like 10 bucks
    Tape or tack them in the problem spots
    and fix this problem in 5 minutes
    Do not waste your time and money🤦‍♂️
    Your welcome

    • @cwb124
      @cwb124 3 года назад +2

      You really think the thinset they applied cost more than $10?

    • @neoasura
      @neoasura Год назад

      @@cwb124 No, but the batch they mixed up and left over that went to waste cost more I bet.