Rare fault - fast flash fault code on Worcester Bosch 30si gc 4731185

Поделиться
HTML-код
  • Опубликовано: 10 сен 2024
  • This was a rare fault, turn up to the Worcester Bosch 30si while it’s in a volatile lockout state, normally it’s the fan, so conducted some tests and found it’s not the fan. Watch the video and let me know if it helped you

Комментарии • 7

  • @ep3thatsall485
    @ep3thatsall485 Год назад

    This job keeps you on your toes! Always something to knock your spirit. Keep em coming 👍

  • @andrewscourfield7530
    @andrewscourfield7530 Год назад

    Good video thanks not always easy what people think

  • @partsarenapro8232
    @partsarenapro8232 2 года назад

    Great work, glad the manuals are proving useful! ❤‍🔥

  • @frankiepc8119
    @frankiepc8119 2 года назад +1

    Strange how the boiler fired when you changed the high limit stat , did you check the resistance of the old ntc it should have read 15 to 24 kohms at approx 20 deg c . Normally if the DHw ntc has gone open circuit the boiler will fire but remain in modulation because it thinks the boiler has reached its set point above 41 degs c it doesn’t cause volatile lock out . I’m suspecting you have a intermittent fan pcb fault and this may come back if your original DHw sensor readings are as above . Interesting to hear from if you do get the dreaded recall . Regards Frankie

  • @qhero4503
    @qhero4503 2 года назад +1

    Another good video,thank you mate

  • @Westy90_
    @Westy90_ 2 года назад

    👍