PV Combinerbox - step by step DIY tutorial

Поделиться
HTML-код
  • Опубликовано: 20 сен 2024

Комментарии • 37

  • @goofykl9
    @goofykl9 Месяц назад +1

    you helped me understand the combiner box wiring.👍

    • @easypowerwall
      @easypowerwall  28 дней назад

      Thanks for the nice comment, that's what my video are all about. KISS keep it stupid simple. No overkill.
      See you soon with more content.
      Franky - EASYPOWERWALL

  • @meilyn22
    @meilyn22 4 месяца назад +1

    You make great videos. Don't stop! With time, you will get a lot of subscribers.

    • @easypowerwall
      @easypowerwall  4 месяца назад

      Thanks for nice comment. Have more plans for videos in the near future.
      Have a nice day.
      Franky easypowerwall

  • @burnzy56469
    @burnzy56469 8 месяцев назад +1

    Thanks heaps one of the best easy to follow and understand pv combiner videos. I'm going to copy your build.

    • @easypowerwall
      @easypowerwall  8 месяцев назад +1

      These comments keep me going, thanks for the kind words. Have fun building your own, if you need info about parts, they're all in the comment section of the video..... Frank - EASYPOWERWALL.

  • @Drillmechanic
    @Drillmechanic 19 дней назад

    Aluminum is metal too not only the steel!

  • @WiSeNhEiMeR-1369
    @WiSeNhEiMeR-1369 22 дня назад

    = I admire your USE of "ferrules"
    COOP
    ...

  • @Sylvan_dB
    @Sylvan_dB 8 месяцев назад +2

    Connector gender is determined by the electric connection, not the plastic shell. So the plastic shell that looks male is the female connector because it's metal bits accept the mating metal bits.

    • @easypowerwall
      @easypowerwall  8 месяцев назад +1

      Thanks for pointing out the obvious...I overlooked this Sylvan. All sharing & caring for a better & greener world.
      Frank - EASYPOWERWALL

  • @jwsolarusa
    @jwsolarusa 8 месяцев назад +1

    Why Diodes?
    Your Solar Panels has inbuilt Diodes already

    • @easypowerwall
      @easypowerwall  8 месяцев назад

      Hey JWsolar, there's a difference between bypass diodes and blocking diodes. A solar panel has bypassdiodes, this prevents that a whole panel is OOS when there's shade on 1 panel. Blocking diodes prevent current flowing between strings. If a bypass diode dies, it can cause a fire....

  • @SebastianHeld
    @SebastianHeld 8 месяцев назад +1

    Let's say you put three modules in series which generate I_mp=13.17 A of current @STC. Your Diode will then drop 0.65 V @ 13.17 A => 8.56 W. You have four of them on a "heat-sink" (which is inside a closed box, with no air flow). That's 34 W of power over multiple hours in full sun shine. I don't think that's a good idea. You don't need these diodes. The maximum reverse current is 16 A (by your fuse). The panels are rated to handle approx 20 A (depends on the exact model). And ask yourself: when would such a large reverse current flow at all?

    • @easypowerwall
      @easypowerwall  8 месяцев назад

      Hi Sebastian, It's a 4S but will use 3S. Box is mounted against the wall facing north. Similar box for 4 string under solar panels works well, no issue. Will make follow up video in spring/summer with IR camera.

  • @Greenwashedhipppie
    @Greenwashedhipppie 11 дней назад

    Great video! Does the solar panel maximum fuse rating apply to the wiring past the combiner box? Let's say have 4 panels with 6 amp rating. And a 15 amp max Fuse rating. If I parallel them once before the combiner box it would be 12 amps then at the box it would be 24 Amps on the way to the charger. Can that flow backwards toward the panels?

    • @easypowerwall
      @easypowerwall  4 дня назад +1

      HEy,
      Because of the anti-flow-back diodes in the combiner box there's no flow backwards from combined power towards solar.
      Your numbers are correct. Check your charger, if possible go for a higher voltage input. Most MPPT accept 100V and convert to 12V.
      Good luck.
      Franky - EASYPOWERWALL

    • @Greenwashedhipppie
      @Greenwashedhipppie 4 дня назад

      @@easypowerwall Thanks. I have asked this question all over the internet.

  • @rizgarn.311
    @rizgarn.311 Месяц назад

    Nice Video mate.
    my inverter is only rated for 27 amp input from PV. if connect all 4 strings in parallel in the combiner box I will exceed the rated amp for the inverter is safe to do so?
    thanks

    • @easypowerwall
      @easypowerwall  Месяц назад

      I would not exceed the rated amperage for your inverter. You can use 2 panels and eventually install seperate MPPT charger.

  • @Thunderst0rn
    @Thunderst0rn 8 месяцев назад

    Thanks for sharing, interesting to see your approach. Very nice result. I was curious, howmuch power would the heat sink need to dissipate? Since the box is closed it cannot dissipate its heat really well I would assume.

    • @easypowerwall
      @easypowerwall  8 месяцев назад

      Hi....the diodes are made for 100A, withv10A they don't get warm. My other box under the solarpanels is closed all the time. It's winter now, will make some infrared images during spring/summer. In short Don't worry about the heatsink size.

    • @Thunderst0rn
      @Thunderst0rn 8 месяцев назад

      @@easypowerwall awesome, thanks

  • @BasarOzgurKahraman
    @BasarOzgurKahraman Месяц назад

    I have panels of the same model and specifications. Due to space limitations, I have to mount them in 3 different areas. I want to place the maximum number of panels in each area. In this case 3 different strings will generate electricity at 3 different output voltages. Can I connect these 3 strings to the mppt after making parallel connections in the combiner box? Or in such a necessity, with considering the minimum cost and maximum efficiency, what would be your solution?

    • @easypowerwall
      @easypowerwall  Месяц назад +1

      Hi, In this case I suggest to use 3 MMPT chargers. One charger for each direction. If panels with different azimuth will be connected to the same combinerbox, this will not work properly.
      Good luck.

  • @GNiers
    @GNiers 5 месяцев назад

    the link above to a DC circuitbreaker is not correct for Ali. It links to an AC circuitbreaker which is not suitable

    • @easypowerwall
      @easypowerwall  4 месяца назад

      Thanks for the remark, indeed, the seller changed it's model. Corrected the link with model I bought. Trust me, an AC breaker wouldn't work in a DC setup.
      Thanks again.
      Franky - EASYPOWERWALL

  • @robjuurlink490
    @robjuurlink490 8 месяцев назад

    Thanks for sharing this valuable insight! I'm about to start a new project featuring the Victron low voltage charge controller. Initially, I thought I could seamlessly connect them in parallel without fussing over fuses and breakers, but it turns out there might be a safer approach. So this post from you is just in time ;-) Can it really cause a fire in the panels? Or will it just damage the panels.
    Btw, the link to the fuse-holders does'n exist anymore "Sorry, the page you requested can not be found:(".

    • @easypowerwall
      @easypowerwall  8 месяцев назад +1

      Hey Rob, thanks for your comments. The shottky diode is an extra safety feature. If the bypass diode fails and that string is in the shade, a current can flow through these cells and cause trouble aka fire. I like to built my stuff to the highest standards so I don't have to worry when I'm away from home for 14 days.
      Good luck build your PV combiner box. I updated the link and added links to amazon as well.
      If you have questions, don't hesitate to contact me, I'm on FB too, EASYPOWERWALL.
      Frank, EASYPOWERWALL

  • @haseebahmed3262
    @haseebahmed3262 4 месяца назад

    Hey Great tutorial, could you please confirm the peak temp recorded on these DC diods and their Brand?

    • @easypowerwall
      @easypowerwall  4 месяца назад

      Will check temperature on sunny day. The model/brand/specsheet of the DC diodes is in the discription of the video.
      If you can't find it, contact me via my FB page "easypowerwall"
      Good luck.
      Franky

  • @danielo8566
    @danielo8566 2 месяца назад +1

    The earthing

    • @nickgkogkas7279
      @nickgkogkas7279 Месяц назад +1

      Earthing is missing. SPD will not work. I am believe that earthing will be setup later.

    • @easypowerwall
      @easypowerwall  Месяц назад

      In the meantime the earthing is done. When covers are closed will do another tour round the powershed.

  • @Νίκο-δ7τ
    @Νίκο-δ7τ Месяц назад +1

    73s