Chiller pipe connection details with all Valves and fittings | HVAC System

Поделиться
HTML-код
  • Опубликовано: 17 янв 2025

Комментарии • 76

  • @asifdamlavi6418
    @asifdamlavi6418 Год назад

    Really, way of your teaching and guiding is totally super

  • @faizanakhtar9086
    @faizanakhtar9086 Год назад +1

    very nice explanation sir

  • @shobhitkumar-mk2cb
    @shobhitkumar-mk2cb 14 дней назад

    Thank you so much brother 🙏

  • @ZubairKhan-xn5mn
    @ZubairKhan-xn5mn 4 года назад +1

    Very good video bhai agli video bhi banana

  • @tasdeeqahmad6012
    @tasdeeqahmad6012 10 месяцев назад +1

    Nice sir

  • @khokansardar
    @khokansardar 6 месяцев назад +1

    Awesome video sir...
    Sir koi DX chiller plant ka video hai kya???

    • @HVACWorld
      @HVACWorld  6 месяцев назад +1

      DX chiller ka video upload kr dunga

  • @abdulraqeeb6514
    @abdulraqeeb6514 Год назад

    Very informative , thanks

  • @parinda4023
    @parinda4023 4 года назад

    Very good vedeo sir👌🏼👌🏼

  • @VikasSingh-sq8pk
    @VikasSingh-sq8pk 4 года назад

    Best contant sir

  • @razvivlogs96
    @razvivlogs96 4 месяца назад +1

    Condenser water line mein higher heat load hoti hai kyunki ismein sensible aur latent heat, dono ko remove karna hota hai. Heat rejection ke liye condenser water line mein high flow rate required hoti hai, taaki heat ko effectively reject kiya ja sake jisse pipe ka Dia 400 hai.

    • @HVACWorld
      @HVACWorld  4 месяца назад

      Evaporator konsi heat reject karta hai??

    • @razvivlogs96
      @razvivlogs96 4 месяца назад

      @@HVACWorld sensible heat

  • @mdansaralam2287
    @mdansaralam2287 4 года назад

    Your video helpful sir

  • @tausifamel3862
    @tausifamel3862 2 года назад +1

    Flow switch to supply me laga hai chillar or condenser ka ????apne return side kaha pls explain

    • @HVACWorld
      @HVACWorld  2 года назад

      Return me hi lagega....

  • @chandanpatel876
    @chandanpatel876 4 года назад +1

    Stainer bhi lga hota h sir

  • @shalluahmad6971
    @shalluahmad6971 4 месяца назад

    Ji practical kr k video dikhaiye

  • @mdarman8564
    @mdarman8564 3 года назад +1

    Sir ispe ek video banaiye practical

  • @shashikantrajak7101
    @shashikantrajak7101 3 года назад +1

    I think strainer also use in evaporator return line?

  • @razvivlogs96
    @razvivlogs96 4 месяца назад +1

    Sir aapane abhi bataya ki balancing valve return line mein lagaya jata ha jaisa ki chilled water return line mein aapane dikhaya.
    Lekin aapane balancing valve condenser water inlet line mein kyun batay..
    Kya yah aise hi rahata hai ya mistake ho gaya hai ?
    Please batao sir

    • @HVACWorld
      @HVACWorld  4 месяца назад

      Cooling Tower k inlet pe lagega. Ye Maine btaya h

    • @razvivlogs96
      @razvivlogs96 4 месяца назад

      @@HVACWorld ok sir
      But mai jahan pe kam karta tha wahan pe sirf butterfly valve laga tha aur motorised actuator valve laga but BMS ki commissioning nahin hui thi jisse vah operation mein nahin tha.

  • @mdzishantahir8368
    @mdzishantahir8368 4 года назад +1

    Very helpful video..
    Sir chiller inlet pe drain valve ka use hoga ya nhi ...
    Pls reply

  • @atif-aftab1atif330
    @atif-aftab1atif330 3 года назад +1

    Sir please tell me inlet line main strainer nhi aaaega????????

    • @HVACWorld
      @HVACWorld  3 года назад

      Strainer hota h....line me Pot strainer laga hua h or pump pe v strainer hota h

    • @atif-aftab1atif330
      @atif-aftab1atif330 3 года назад +1

      @@HVACWorld sir apne diagram mm strainer ka nd NRV ka koyi zikar nhi kiya chiller ke... Islye mm confused kr gya... Please tell ke strainer nd NRV bhi aaega verna mera pura chiller concpet hi bigar jaega... Samajhne ka.

    • @HVACWorld
      @HVACWorld  3 года назад +1

      Chiller pe strainer ya NRV nhi hota h. Strainer or NRV dono primary pump or secondary pump pe hota h..sath hi sath primary pump se phle jo building se pani return aa rha h usme pot strainer laga hota h bada sa.

    • @atif-aftab1atif330
      @atif-aftab1atif330 3 года назад +1

      @@HVACWorld jazakallah khair sir apka bahut bahut shukriya

    • @atif-aftab1atif330
      @atif-aftab1atif330 3 года назад +1

      I'm following all your vedios for betterment of my HVAC knowledge fo so long ALHAMDULILLAH ,that's what only confusion I had which clearled mashallah may god grace with great future nd in the event of covid-19 may god grace you with good health. Aameen .

  • @TAHIRHUSSAINMEPINDUSTRY
    @TAHIRHUSSAINMEPINDUSTRY 4 года назад +2

    Excellent voice & explanation, one question, how much pressure drop across chiller evaporator & how much pressure drop across condenser which we will read by pressure gauge. And when we will alert ?

    • @HVACWorld
      @HVACWorld  4 года назад

      Thanks for compliment.....once again thanks for raising many questions....I would love to answer your questions in my live session....may tomorrow or day after tomorrow I will be on live

    • @TAHIRHUSSAINMEPINDUSTRY
      @TAHIRHUSSAINMEPINDUSTRY 4 года назад +1

      @@HVACWorld how I will know u r live?

    • @HVACWorld
      @HVACWorld  4 года назад

      You will get notification once I will live

    • @TAHIRHUSSAINMEPINDUSTRY
      @TAHIRHUSSAINMEPINDUSTRY 4 года назад

      @@HVACWorld ok thanks

    • @sagarsuryavanshi2393
      @sagarsuryavanshi2393 3 года назад

      @@HVACWorld send link of rply to dis query...

  • @khurshadkhan9918
    @khurshadkhan9918 3 года назад +1

    Bhai chillat me supply return ho gya kya hoga

  • @jiszeeshanhashmi6377
    @jiszeeshanhashmi6377 3 года назад +1

    Automatic clear clean systems ????

  • @aakilkhan4799
    @aakilkhan4799 3 года назад +1

    Sir.muje achu.me konse.vall.hote hai

  • @zahidkalim8649
    @zahidkalim8649 3 года назад +1

    Strainer kahan laga hota hai inlet mein ya outlet mein ?

  • @mohammadshakil5935
    @mohammadshakil5935 4 года назад

    Sir... Ahu me chill water line down me hi q connect karte Hai..... Pls reply

  • @usmankhalid1806
    @usmankhalid1806 3 года назад +1

    Respected Sir please make the video on 3 way motorized valve in AHU valve assembley along with a control wiring. please itsa request i will anxiously

    • @HVACWorld
      @HVACWorld  3 года назад

      Ok

    • @usmankhalid1806
      @usmankhalid1806 3 года назад +1

      @@HVACWorld bundle of thanks actually i am the old subsriber of your channel. Stay blessed

  • @narendrakangralkar4109
    @narendrakangralkar4109 Год назад +1

    i thing arrow direction showing wrong side to between cooling tower to condenser side plz check

  • @Vinod-t9p
    @Vinod-t9p Год назад +1

    Condenser water dia -400mm and -chilled water pipe dia -300 mm kyo hai sir, pls tell me about it.

    • @HVACWorld
      @HVACWorld  Год назад +1

      Condenser line has more water flow (GPM) than Chilled water flow ( GPM)

  • @madhabjha9761
    @madhabjha9761 4 года назад +1

    Condeser ki gpm require ment chilled water ki requirement se jada hoti h...chilled water 2.4gpm/TR & 3 gpm/TR for condenser water.

  • @OmprakashKumar-ot1ib
    @OmprakashKumar-ot1ib Год назад

    Kaise pata chalega ki kis pipeline me kitna GPM pani jayega

  • @OmprakashKumar-ot1ib
    @OmprakashKumar-ot1ib Год назад

    Line me water flow jyada aur kam kaise karenge

  • @Ahadansari-h1o
    @Ahadansari-h1o 3 года назад

    Pls upload chiller actual connection video sir

  • @khurshidalam9689
    @khurshidalam9689 4 года назад +1

    Automatic tube cleaning system ka video chahiye

    • @HVACWorld
      @HVACWorld  4 года назад

      ruclips.net/video/NVuSqluaLqc/видео.html
      Automatic tube cleaning system

  • @kashifiqbalzafar
    @kashifiqbalzafar 4 года назад

    hello sir
    kindly upload video on automatic tube cleaning system in detail.

  • @sbhosale2101
    @sbhosale2101 3 года назад

    Sir, at 2.03 mins. you said its chilled water supply arrow, i think its chilled water retrun line.

  • @gramathara4907
    @gramathara4907 4 года назад

    Non return valve?

  • @saikatghosh3611
    @saikatghosh3611 2 года назад

    How to measure chiller In out valve size

  • @naveengupta5766
    @naveengupta5766 3 года назад +1

    Sir es main NRV bhi hota hai

  • @mnajibullah
    @mnajibullah 4 года назад +1

    Show me love

  • @anuragshukla627
    @anuragshukla627 4 года назад

    Hvac course kaha se kre

  • @mnajibullah
    @mnajibullah 4 года назад

    I'm the first one here

  • @ashokkumarsahani394
    @ashokkumarsahani394 Год назад +1

    16 ka12 ka pipe hai

  • @SanjayKumar-xq9dw
    @SanjayKumar-xq9dw 4 года назад

    stainer ?

    • @HVACWorld
      @HVACWorld  4 года назад

      Chiller k inlet pe strainer nahi hota hai...wo pump pe hota hai

  • @sanjeevtiwari3912
    @sanjeevtiwari3912 4 года назад

    Sir how to calculate GPM

  • @abdulgaffar9590
    @abdulgaffar9590 2 года назад +1

    Where is strainer

  • @sbhosale2101
    @sbhosale2101 3 года назад

    No bypass for 2 way control valve and wrong position of butterfly valve

  • @ramnivasverma8021
    @ramnivasverma8021 4 года назад

    Videos dikhai sir