l TXV फॉल्ट फाइंडिंग - १ l TXV Fault Finding -1 l

Поделиться
HTML-код
  • Опубликовано: 2 фев 2025

Комментарии • 95

  • @vijaygautam2997
    @vijaygautam2997 5 лет назад

    you are my best teachar sir

  • @ganeshkamble6892
    @ganeshkamble6892 4 года назад +1

    Nice video.
    Can you please tell which refrigerant gas is present in filler bulb.

  • @md.Inamulhaque3406
    @md.Inamulhaque3406 2 года назад

    Sir thank you so much for wonderful classes respect you sir

  • @muhammadtanvir703
    @muhammadtanvir703 5 лет назад +1

    Section pressure km hony sy Lp system ko off ni karway ga kya

    • @girishshinde
      @girishshinde  5 лет назад

      Katega agar suction pressure 35 psig se kam hota hai tho

  • @travelindvolgs8548
    @travelindvolgs8548 5 лет назад +1

    Sir. How compressor recive total gas state. May be some liquid also enter this will effect comprossor. Which device we use. Tht allow only gases state in comprossor.

    • @girishshinde
      @girishshinde  5 лет назад

      We use accumulator to prevent liquid flood back to compressor

  • @muhammadtanvir703
    @muhammadtanvir703 5 лет назад

    Video bhot achi thi but ik question mind me a raha he jb section pressure km hoga to kya compressor heatup ni hoga..?

  • @ShadabkhanKhan-yo1lj
    @ShadabkhanKhan-yo1lj 7 месяцев назад

    Bt sir vrf. Me jo pcb use hoti hai uspe ek video bnay pllzzz.... Kon si pcb kaise kam krti hai.... Ye filler bulb jaise loos ho gya to pcb pe kya reaction hota hai pllzzzz sir. Thank you 😊

  • @batistafrose6009
    @batistafrose6009 5 лет назад

    Very nice video sir ji.

  • @willscarerefrigerationhous9794
    @willscarerefrigerationhous9794 4 года назад

    Good information sir thank you

  • @chaudharyghulamdastgir3284
    @chaudharyghulamdastgir3284 5 лет назад

    Bohat badiya sir thanks alot

  • @angreentachairconditioning4687
    @angreentachairconditioning4687 5 лет назад

    nyc vedeo Sir

  • @saddamtahashildar6235
    @saddamtahashildar6235 4 года назад

    Expensen valve minimum persantagee kitna hona chahiye or 100 open huwa tho kya froblem

  • @tknislamicnetwork4244
    @tknislamicnetwork4244 5 лет назад

    Good knowledge

  • @techworld-wr3vu
    @techworld-wr3vu 5 лет назад

    Sir please flight mai kese Air conditioning working karta hai uske related video banaiye

  • @sumitdey7324
    @sumitdey7324 5 лет назад

    #Sawal sir P.H.E ke upar video bano plz or usme ye bhi batao ke ye kese kharab hoti hai ye kese pta kare

  • @rahamatshaikh314
    @rahamatshaikh314 5 лет назад

    Hi sir
    Diaphragm ke andar gas ka kitna psi hota h

  • @sumitdey7324
    @sumitdey7324 5 лет назад

    #SAWAL sir me panel a.c ka work karta hu usme watts me likha hota hai rittal ki machine me usko ton me kese pta kare or iske faults erros samjha to plz achhe se

  • @danishal9326
    @danishal9326 4 года назад

    Sir Hum Kolkata se hu app ka live Class ketna baje hota hai our month ketna hai

  • @rohitsingh-no5jp
    @rohitsingh-no5jp 5 лет назад

    Thanks you for your video.
    Thanks so mach

  • @baate...2058
    @baate...2058 4 года назад

    Which gas is there inside filler bulb?

  • @mdirfanhaider9976
    @mdirfanhaider9976 5 лет назад +1

    Very niccc vedio sir I want to know how to lod and unlod in reciprocating compressor and screw..

  • @arvindadak3711
    @arvindadak3711 5 лет назад

    Sir ye super heat kya hota h

  • @anwarkhanazmi1074
    @anwarkhanazmi1074 5 лет назад +1

    Sir split ac hai compressor thodi der chalta hai phir band ho jata hai adha ghanta bad fir start hota hai fan chlta rahta hai kya fault ho sakta hai?

  • @mdnaim8535
    @mdnaim8535 4 года назад

    Sensor ke andar kon sa gas hota hai

  • @dineshhatti633
    @dineshhatti633 5 лет назад

    Sir expansion valve new hai phir bhe gas suction me nahi jaara hai kya foulti hai sir.plz help me

  • @ashwadkhan9818
    @ashwadkhan9818 4 года назад

    Sir aap Fara night our Calces v batayea sat ma

  • @IsrarCR7
    @IsrarCR7 5 лет назад

    Choking ke upar video banaiye sir

  • @sampatsahu9100
    @sampatsahu9100 3 года назад

    Thank you sir

  • @kishanhit1965
    @kishanhit1965 4 года назад

    Sir Aap playlist Update kr dijiye Topic wise

  • @shaikhshahzad7177
    @shaikhshahzad7177 5 лет назад

    Thanks a lot sir.. Keep it on

  • @dannialgd3220
    @dannialgd3220 5 лет назад

    Sir
    Panasonic invetor ac hai usme EE error show ho rha ky fault hai sir

    • @rajtechnicaltech8046
      @rajtechnicaltech8046 3 года назад

      E:EE indicates an error has occurred. 1. REMOTE CONTROLLER DISPLAY. 1) Stop the air conditioner operation. 2) Press the set temperature buttons simultaneously for 5 seconds or more to start the self-diagnosis.

  • @saddamkhan-fq3kp
    @saddamkhan-fq3kp 5 лет назад

    Dear sir, superheat kaise calculate kare ,make video

  • @SatendraKumar-we6oc
    @SatendraKumar-we6oc 4 года назад

    Volumetric efficiency of compressor कैसे निकालते है pl sir video vanao

  • @mdrashidparwez1557
    @mdrashidparwez1557 5 лет назад +2

    Sir plz short me reply mat dena
    Explain kar k bataiye plz.
    Sir aap se ye puchhna chahte hai mera iTI complete ho gya hai .iske baad mai kya karu. Soch raha hu hvac karne k liye lekin aap ne bataya tha apprentice karne k liye .hvac k baad apprentice kr sakte hai sir aap bataiye kya kare explain kar k bataiye taki samajh me aaye .plz

  • @yuvraj-gaming.
    @yuvraj-gaming. 5 лет назад +1

    Sir agar txv k uper barf jama ho rahi h to kya fault h

    • @jassirama6056
      @jassirama6056 5 лет назад

      Txv restricted or powerhead bad

    • @girishshinde
      @girishshinde  5 лет назад

      Low suction pressure ke karan ice jamti hai, Reason Filter drier choke, faulty TXV, leak in system etc

  • @shaukathayat1083
    @shaukathayat1083 5 лет назад

    Sir kesi din ducts awr iski designing pe b videos banaein!!
    Danewaad !

  • @sumitdey7324
    @sumitdey7324 4 года назад

    Sir mere saath aaj yehi problem ho rahi hai Kya karu back Jada dikha raha hai cooling nhi ho rahi hai

  • @mhworld3898
    @mhworld3898 5 лет назад

    Awesome explain sir thank you.

  • @shitkumar1015
    @shitkumar1015 5 лет назад

    Thanks

  • @amjadhusain8807
    @amjadhusain8807 5 лет назад

    Sir plz prectical me expention valve open kar ke bataye plz

  • @tariqsayyad2778
    @tariqsayyad2778 5 лет назад

    Sir o general vrf error code kaise samzhe

  • @amitpandey9804
    @amitpandey9804 5 лет назад +1

    I think in that case suction pressure will drop as it will be a case of liquid flooding.. how u concluded that SP will go up??? Superheat will be even negative .... Amps consumption will go up coz compressor will need extra power to compresse liquid refrigerant

  • @anjanshrestha7011
    @anjanshrestha7011 4 года назад +2

    How to adjust sir

  • @krishnakumarsingh2818
    @krishnakumarsingh2818 5 лет назад

    How effect to fit Big explanation valve fit in ac

  • @rishabmehta7906
    @rishabmehta7906 5 лет назад

    Dear sir, you are doing very well, I will watch your all vlogs and you described in breif and in a simple manner, sir if it is possible please share your knowledge regarding solar panel how they produce electricity ,thanks sir. Have a nice day!

  • @avinavanand2066
    @avinavanand2066 5 лет назад +1

    Sir I humbly requested to you sir
    HVAC safety device k uper ek video bana do sir please
    🙏🙏🙏🙏🙏🙏🙏🙏🙏🙏🙏🙏🙏🙏🙏🙏🙏🙏🙏🙏🙏🙏🙏🙏🙏🙏🙏🙏🙏🙏🙏🙏🙏🙏🙏🙏🙏🙏🙏🙏🙏🙏🙏🙏🙏🙏🙏🙏🙏🙏🙏🙏🙏🙏🙏🙏🙏🙏🙏🙏🙏🙏🙏🙏🙏🙏🙏🙏🙏🙏🙏🙏🙏🙏🙏🙏🙏🙏

  • @mhworld3898
    @mhworld3898 5 лет назад

    Sir compressor oil k bare may video banaiye please.

  • @sanjeet920
    @sanjeet920 5 лет назад

    Sir ji physically chillar plant pr jaker practically ek baar one by one bataye please🙏🙏

  • @salmanakhtar1534
    @salmanakhtar1534 5 лет назад

    Hello sir,
    Kindly upload video regarding 2 way and 3 way valve.

  • @slark330slark5
    @slark330slark5 5 лет назад

    Sir expenshion valve ki setting kaise Karen ye bataiye

  • @sohailb162
    @sohailb162 5 лет назад

    Sir homdaty kam karne ki video upload kerne

  • @arvindadak3711
    @arvindadak3711 5 лет назад

    Superheat, sub cooling, cooling tower range, cooling tower approach saturation temperature kya hota h uske bare me 1 video banao plz

  • @myvillegerepairs3037
    @myvillegerepairs3037 5 лет назад

    Sir I want do iti RAC plz guide me

  • @krishnakumarsingh2818
    @krishnakumarsingh2818 5 лет назад

    How to identify the correct exp valve

  • @hasmatansari6485
    @hasmatansari6485 5 лет назад

    # all compressor fault mak videos sir

  • @joshihimanshu7981
    @joshihimanshu7981 5 лет назад

    Vrv gas charging kai barai mai video bandai sar ji..aap nai koi bhi video nahi banaya sir ji

  • @aaronstone.6243
    @aaronstone.6243 5 лет назад

    Filler bulb contain gas ..that called volatile.

  • @ansarizzama7543
    @ansarizzama7543 5 лет назад

    kya aap sahi se sMjha sakte ho mya aap apna mobile nambur de sakte ho watshop wala

  • @ansarizzama7543
    @ansarizzama7543 5 лет назад

    sir mai naho samjha ho

  • @sunitasurse8824
    @sunitasurse8824 5 лет назад +1

    Ye kunta deploma hai

    • @girishshinde
      @girishshinde  5 лет назад

      Air conditioning and refrigeration

  • @hasmatansari6485
    @hasmatansari6485 5 лет назад

    # Error code fault